Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Dent ; 70: 46-50, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29275171

RESUMEN

OBJECTIVE: To investigate the longevity and reasons for failure of posterior cast Class II gold inlays and onlays among a group of Norwegian adults. The term inlay was used for both inlays and onlays. METHODS: A cohort of 138 patients regularly attending a general practice for check-up were examined in 2016. The patients had a total of 391 posterior gold inlays placed in the period 1970-2015. The inlays were categorized as successful, repaired or failed. Reasons for failure were classified as either "secondary caries", "fractures", "lost inlay" or "other". Participation was voluntary and no compensation was given. RESULTS: The mean age of the patients at placement was 50.8 years (SD: 12.7 yr). Most gold inlays were placed in molars (85.9%) and 14.1% in premolars; 49.4% of the inlays were in the maxilla and the 50.6% in the mandibula. Average length of follow-up was 11.6 years (range: 1-46 years, SD: 7.9); 82.9% were classified as successful, 10.7% as repaired and 6.4% as failed. Reasons for failure were secondary caries (41.3%), lost inlay (25.4%), fractures (23.8%) and other (9.5%). Mean annual failure rate (AFR) was 1.69% for repaired and failed inlays combined. However, if repaired inlays were considered as success, the AFR decreased to 0.57%. Multi-level Cox regression analyses identified low age of the patient and high number of restored surfaces as risk factors for failure. CONCLUSION: The present retrospective clinical study demonstrated an acceptable annual failure rate for Class II cast gold inlays.


Asunto(s)
Fracaso de la Restauración Dental , Aleaciones de Oro/química , Incrustaciones/efectos adversos , Incrustaciones/clasificación , Adulto , Diente Premolar , Caries Dental , Preparación de la Cavidad Dental/clasificación , Femenino , Estudios de Seguimiento , Oro , Humanos , Estimación de Kaplan-Meier , Longevidad , Masculino , Persona de Mediana Edad , Diente Molar , Análisis de Regresión , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
2.
J Adhes Dent ; 18(1): 59-67, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26814319

RESUMEN

PURPOSE: To clinically evaluate the performance of indirect composite resin restorations cemented with conventional and self-adhesive resin cements over a 12-month period. MATERIALS AND METHODS: Ten patients fulfilled all the inclusion criteria. Twenty-four composite resin restorations were performed using an indirect technique and cemented with a resin cement (RelyX ARC) or a self-adhesive resin cement (RelyX U100). Two independent evaluators analyzed the restorations using modified USPHS criteria after periods of two weeks and 6 and 12 months. Statistical significance between the cements at each timepoint was evaluated with the Wilcoxon test and between timepoints with the Mann-Whitney test, both at a significance level of 5%. Fisher's exact test was used to assess the occurrence of absolute failures. RESULTS: No statistically significant differences were found between the groups at the same timepoint nor between groups at different timepoints. The only significant difference was found for color match for both groups after 12 months. CONCLUSION: After 12 months, indirect composite resin restorations cemented with self-adhesive resin cement performed similarly to those cemented with conventional resin cement.


Asunto(s)
Cementación/métodos , Resinas Compuestas/química , Materiales Dentales/química , Incrustaciones/métodos , Cementos de Resina/química , Adolescente , Adulto , Anciano , Bisfenol A Glicidil Metacrilato/química , Color , Preparación de la Cavidad Dental/clasificación , Preparación de la Cavidad Dental/métodos , Adaptación Marginal Dental , Pulido Dental/métodos , Femenino , Estudios de Seguimiento , Humanos , Incrustaciones/clasificación , Curación por Luz de Adhesivos Dentales/instrumentación , Masculino , Persona de Mediana Edad , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Propiedades de Superficie , Adulto Joven
4.
Eur J Prosthodont Restor Dent ; 22(3): 117-24, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25831713

RESUMEN

The purpose of this study is to review the available literature related to composite inlays. Electronic databases published up to November 2013 were searched. Studies that evaluate composite resin inlays for the restoration of posterior teeth were selected. The studies should compare composite inlays against gold inlays, ceramic inlays and direct composite fillings regarding longevity, aesthetic quality and postoperative sensitivity or comparing the clinical effectiveness of them on premolars versus molars or on 1-2 surface preparations versus multi-surface preparations. Despite the heterogeneity of the available clinical trials composite inlays seem to be an effective method for the restoration of posterior teeth.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Incrustaciones , Cerámica/química , Restauración Dental Permanente/clasificación , Estética Dental , Aleaciones de Oro/química , Humanos , Incrustaciones/clasificación
5.
Int J Periodontics Restorative Dent ; 32(3): e87-94, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22408783

RESUMEN

The purpose of this randomized clinical trial was to determine the clinical wear behavior of three nanofilled composites (Filtek Supreme XT [FS], Tetric EvoCeram [TEC], and Aelite Aesthetic [AA]) with two indirect composites (Estenia [E] and Tescera ATL [TATL]) on permanent molar teeth. Fifty-four patients whose treatment plans included moderate Class I and/or II restorations on molar teeth were selected for inclusion in this study. Wear was measured by use of gypsum replicas at baseline and 6 and 12 months using three-dimensional scanning and rapid-form software to elucidate the wear mechanisms. For statistical analyses, one-way analysis of variance and the Scheffe test were used. Statistical results revealed that wear behavior of TATL was significantly different from that of AA (P < .05). No significant differences were detected between AA and E (P > .05) or between TEC, FS, and TATL composite resins (P > .05). The results showed similar clinical performance between the five composite resins evaluated. Therefore, composite resins may be indicated for the restoration of posterior teeth. However, the composition of the composite resin did affect the wear behavior of the composite material.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Alisadura de la Restauración Dental/clasificación , Restauración Dental Permanente/clasificación , Grabado Ácido Dental/métodos , Adulto , Caries Dental/terapia , Recubrimiento de la Cavidad Dental/métodos , Preparación de la Cavidad Dental/clasificación , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Incrustaciones/clasificación , Masculino , Ensayo de Materiales , Metacrilatos/química , Diente Molar/patología , Nanocompuestos/química , Poliuretanos/química , Técnicas de Réplica , Cementos de Resina/química , Propiedades de Superficie , Adulto Joven
6.
Dent Mater J ; 30(5): 648-54, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21946485

RESUMEN

The purpose of this study was to establish a geometric design method for the occlusal outlines of complex inlay cavities as a continuation study of a previous design method for simple class I inlay cavity. A method for extending the occlusal outline to the buccal or lingual groove and to three preparation types of the proximal portions of class II inlay cavities -namely, straight line preparation, sweeping curve preparation, and reverse curve preparation- was investigated. To ensure the smoothness of the occlusal outline, a Bézier curve was introduced in the design. A minimal number of control points for the curve was applied to define each preparation type. The design method was experimentally applied to mandibular and maxillary first molars. Smooth outlines of the complex inlay cavities in the molars with tool accessibility throughout the cavities were achievable by using the present method.


Asunto(s)
Diseño Asistido por Computadora , Preparación de la Cavidad Dental/clasificación , Diseño de Prótesis Dental , Incrustaciones/clasificación , Algoritmos , Aleaciones Dentales/química , Esmalte Dental/anatomía & histología , Porcelana Dental/química , Humanos , Diente Molar/anatomía & histología , Programas Informáticos
7.
Acta Odontol Scand ; 69(3): 182-92, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21231818

RESUMEN

OBJECTIVE: To evaluate the effect of resin coating and occlusal loading on microleakage of class II computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic restorations. MATERIAL AND METHODS: Molars were prepared for an mesio-occlusal-distal (MOD) inlay and were divided into two groups: non-coated (controls); and resin-coated, in which the cavity was coated with a combination of a dentin bonding system (Clearfil Protect Bond) and a flowable resin composite (Clearfil Majesty Flow). Ceramic inlays were fabricated using the CAD/CAM technique (CEREC 3) and cemented with resin cement (Clearfil Esthetic Cement). After 24 h of water storage, the restored teeth in each group were divided into two subgroups: unloaded or loaded with an axial force of 80 N at a rate of 2.5 cycles/s for 250,000 cycles while stored in water. After immersion in 0.25% Rhodamine B solution, the teeth were sectioned bucco-lingually at the mesial and distal boxes. Tandem scanning confocal microscopy (TSM) was used for evaluation of microleakage. The locations of the measurements were assigned to the cavity walls and floor. RESULTS: Loading did not have a significant effect on microleakage in either the resin-coated or non-coated group. Resin coating significantly reduced microleakage regardless of loading. The cavity floor exhibited greater microleakage compared to the cavity wall. TSM observation also revealed that microleakage at the enamel surface was minimal regardless of resin coating. In contrast, non-coated dentin showed extensive leakage, whereas resin-coated dentin showed decreased leakage. CONCLUSIONS: Resin coating with a combination of a dentin-bonding system and a flowable resin composite may be indicated prior to impression-taking when restoring teeth with CAD/CAM ceramic inlays in order to reduce microleakage at the tooth-resin interface.


Asunto(s)
Diseño Asistido por Computadora , Recubrimiento de la Cavidad Dental , Filtración Dental/prevención & control , Porcelana Dental , Diseño de Prótesis Dental , Incrustaciones , Resinas Compuestas , Análisis del Estrés Dental , Recubrimientos Dentinarios , Humanos , Incrustaciones/clasificación , Microscopía Confocal , Tercer Molar , Estadísticas no Paramétricas
8.
Clin Oral Investig ; 15(6): 923-9, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20830497

RESUMEN

In endodontically treated teeth, cuspal coverage plays a fundamental role in reducing the risk of fracture. However, the adhesive techniques with or without fiber post increased the possibilities in restoring root-filled teeth. The aim of this study was to determine the effect of the fiber post and/or post length and/or cuspal coverage on the fracture resistance of endodontically treated maxillary premolars. Seventy intact single-rooted maxillary premolars were selected and divided in seven groups of ten each: "intact teeth" (control), "inlay without fiber post" (G1), "inlay with long fiber post" (G2), "inlay with short fiber post" (G3), "onlay without fiber post" (G4), "onlay with long fiber post" (G5), and "onlay with short fiber post" (G6). Except for intact teeth, all specimens were prepared with a mesio-occluso-distal (MOD) cavity, endodontically treated and restored with or without long or short post, with or without cusp coverage. All specimens were thermal-cycled, exposed to a cyclic loading, and then submitted to the static fracture resistance test. Fracture loads and mode of failure were evaluated. A statistically significant difference in fracture resistance was found between group 1 and the other groups (p < 0.001). χ2 test showed statistically significant differences in the patterns of fractures between the groups (p < 0.001). The highest number of favorable fractures was observed in groups 3 and 4. Similar fracture resistance was detected in maxillary premolars endodontically treated with MOD cavity preparations, restored with either direct resin composite with fiber post or cusp capping. The "short post" direct restoration may be a valid alternative in the restoration of root-filled premolars.


Asunto(s)
Diente Premolar/fisiopatología , Diseño de Prótesis Dental , Incrustaciones , Técnica de Perno Muñón/instrumentación , Diente no Vital/fisiopatología , Grabado Ácido Dental/métodos , Resinas Compuestas/química , Preparación de la Cavidad Dental/clasificación , Materiales Dentales/química , Fracaso de la Restauración Dental , Recubrimientos Dentinarios/química , Humanos , Incrustaciones/clasificación , Ensayo de Materiales , Maxilar , Metacrilatos/química , Nanocompuestos/química , Ácidos Fosfóricos/química , Preparación del Conducto Radicular/instrumentación , Estrés Mecánico , Temperatura , Factores de Tiempo , Fracturas de los Dientes/fisiopatología , Agua/química
9.
Clin Oral Investig ; 15(5): 617-23, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20694567

RESUMEN

The study was aimed at assessing the influence of the cement manipulation and ultrasounds application on the bonding potential of self-adhesive resin cements to dentin by microtensile bond strength testing and microscopic observations of the interface. Fifty-six standardized mesio-occlusal class II cavities were prepared in extracted third molars. Class II inlays were made using the nano-hybrid resin composite Gradia Forte (GC Corp, Tokyo, Japan), following the manufacturer's instruction. The sample was randomly divided into two groups (n = 28) according to the luting technique. Half of the specimens were luted under a static seating pressure (P), while the other ones were cemented under vibration (V). The inlays were luted using the following self-adhesive resin cements: G-Cem (G, GC Corp., Tokyo, Japan) Automix (GA) and Capsule (GC); RelyX Unicem (RU, 3 M ESPE, Seefeld, Germany) Clicker (RUC) and Aplicap (RUA). Microtensile sticks and specimens for scanning electron microscope (SEM) observations were obtained from the luted teeth. The interfacial strengths measured for the cements under static pressure or ultrasonic vibration were [median (interquartile range)]: GC/V 4 (2.3-7.9); GC/P 6.8 (4.1-10.1); GA/V 3 (1.9-6.7); GA/P 1.9 (0-5.1); RUC/V 6.6 (4.6-9.8); RUC/P 4.1 (1.8-6.4); RUA/V 6.2 (2.4-10.4); RUA/P 3.4 (0-5.4). The cement formulation influenced dentin bond strength of G. RU bond strength was affected by the luting technique. SEM analysis revealed a homogeneous structure and reduced porosities for both cements as a result of ultrasonic vibration. RU benefited from the application of ultrasounds, while GC achieved higher bond strengths than GA.


Asunto(s)
Cementación/métodos , Incrustaciones , Cementos de Resina/química , Adhesividad , Resinas Compuestas/química , Recubrimiento Dental Adhesivo , Preparación de la Cavidad Dental/clasificación , Adaptación Marginal Dental , Dentina/ultraestructura , Humanos , Humedad , Incrustaciones/clasificación , Ensayo de Materiales , Microscopía , Microscopía Electrónica de Rastreo , Tercer Molar , Nanocompuestos/química , Porosidad , Presión , Estrés Mecánico , Propiedades de Superficie , Temperatura , Resistencia a la Tracción , Factores de Tiempo , Ultrasonido/instrumentación , Vibración
10.
Indian J Dent Res ; 22(6): 877, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22484893

RESUMEN

AIM: The aim of this study was to evaluate the in vitro fracture resistance of teeth restored with bonded ceramic inlay and direct composite resin restoration in comparison to the normal tooth. MATERIALS AND METHODS: This study evaluated the fracture strength of the teeth restored with bonded ceramic inlay and direct composite resin restoration in comparison to the normal teeth. Thirty intact human maxillary first premolars were assigned to three groups: Group 1 - comprising sound/unprepared teeth (control). Group 2 - comprising of Class-II direct composite resin restored teeth and Group 3 - comprising Class-II ceramic inlay restored teeth. Cavities were prepared with occlusal width of 1/3 intercuspal distance and 2 mm deep pulpally. Group 2 teeth were restored with hybrid composite resin (Z350 3M ESPE, USA) and group 3 teeth were restored with Vitadur Alpha alumina (Ivoclare Vivadent, Liechtenstein, Europe). Ceramic inlay was bonded with adhesive cement (rely X resin cement of 3MESPE, USA). The specimens were subjected to a compressive load until they fractured. Data were analyzed statistically by unpaired Student's t test. RESULTS: The fracture resistant strength, expressed as kilonewton (KN), was group 1 - 1.51 KN, group 2 - 1.25 KN, and group 3 - 1.58 KN. Statistically, group III had highest fracture resistance followed by group I, while group II had the lowest average fracture resistance. CONCLUSION: The fracture resistant strength of teeth restored with ceramic inlay was comparable to that of the normal intact teeth or slightly higher, while teeth restored with direct composite resin restoration showed less fracture resistant strength than that of the normal teeth.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Porcelana Dental/química , Diseño de Prótesis Dental , Incrustaciones , Fracturas de los Dientes/fisiopatología , Grabado Ácido Dental/métodos , Óxido de Aluminio/química , Bisfenol A Glicidil Metacrilato/química , Recubrimiento Dental Adhesivo/métodos , Preparación de la Cavidad Dental/clasificación , Análisis del Estrés Dental/instrumentación , Recubrimientos Dentinarios/química , Cementos de Ionómero Vítreo/química , Humanos , Ácido Fluorhídrico/química , Incrustaciones/clasificación , Ensayo de Materiales , Ácidos Fosfóricos/química , Cementos de Resina/química , Estrés Mecánico , Temperatura , Factores de Tiempo , Diente/fisiología , Agua/química
11.
Oper Dent ; 34(2): 211-6, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19363977

RESUMEN

OBJECTIVES: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). METHODS: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried. The specimens were divided into two groups


Asunto(s)
Silicatos de Aluminio/química , Recubrimiento Dental Adhesivo/métodos , Porcelana Dental/química , Ácido Fluorhídrico/química , Incrustaciones , Grabado Ácido Dental/métodos , Precipitación Química , Preparación de la Cavidad Dental/clasificación , Dentina/ultraestructura , Humanos , Incrustaciones/clasificación , Ensayo de Materiales , Cementos de Resina/química , Silanos/química , Estrés Mecánico , Propiedades de Superficie , Temperatura , Resistencia a la Tracción , Agua/química
12.
Oper Dent ; 33(5): 587-92, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18833866

RESUMEN

This study evaluated the effect of cyclic loading on the marginal adaptation and microtensile bond strength of direct vs indirect Class II composite restorations in an in-vitro model. Forty Class II cavities were prepared on the mesial surface of extracted human maxillary first premolars and divided into two groups: Group I--direct composite restorations and Group II--indirect composite restorations. Groups I and II were further divided into subgroups: A (without cyclic loading) and B (with cyclic loading of 150,000 cycles at 60N). The gingival margin of the proximal box was evaluated at 200x magnification for marginal adaptation in a low vacuum scanning electron microscope. The restorations were sectioned perpendicular to the bonded surface into 1 mm thickslabs. The slabswere further trimmed at the interface to produce a cross-sectional surface area of approximately 1 mm2. All specimens were subjected to microtensile bond strength testing. The marginal adaptation was analyzed using descriptive studies and bond strength data were analyzed by one-way ANOVA test. The indirect composite restorations performed better under cyclic loading.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo , Adaptación Marginal Dental , Materiales Dentales/química , Restauración Dental Permanente/clasificación , Incrustaciones , Grabado Ácido Dental , Abrasión Dental por Aire , Diente Premolar , Bisfenol A Glicidil Metacrilato/química , Recubrimiento de la Cavidad Dental , Preparación de la Cavidad Dental/clasificación , Esmalte Dental/ultraestructura , Pulido Dental , Análisis del Estrés Dental/instrumentación , Recubrimientos Dentinarios/química , Humanos , Incrustaciones/clasificación , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Cementos de Resina/química , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
13.
Quintessence Int ; 39(1): 65-71, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18551219

RESUMEN

OBJECTIVE: The aims of this prospective clinical study were (1) to evaluate the clinical performance of Signum composite inlays over a 3-year period; (2) to investigate the clinical efficacy of composite inlays in premolars versus molars; and (3) to evaluate differences between 1- or 2-surface inlays and multisurface inlays. METHOD AND MATERIALS: One hundred thirteen composite inlays were placed in 30 patients by a clinician. All the inlays were made by the same laboratory technician using only one composite material (Signum, Heraeus Kulzer). All the restorations were bonded with a 3-step bonding system and a composite luting cement. The restorations were assessed after placement by a clinician who had not been involved with the placement of the restorations, in accordance with the modified US Public Health Service criteria. RESULTS: Three of the 113 experimental restorations had to be replaced; the total failure rate was 2.6% after 3 years. At baseline, 88.5% to 100% of the inlay restorations were rated as excellent (Alpha). Statistically significant (P < .05) differences were observed during the study for surface roughness, anatomic form at the margin, marginal integrity, and inlay integrity. The comparison of the clinical outcome of inlays in premolars versus molars and with 1 or 2 surfaces versus multisurfaces showed no significant differences, except for the parameters anatomic form at the margin and marginal integrity. CONCLUSION: Composite inlays demonstrated a very high success rate (97.4%) after 3 years. Neither the size of the restorations nor the tooth type significantly affected the clinical outcome of the restorations.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo/métodos , Materiales Dentales , Incrustaciones , Grabado Ácido Dental/métodos , Adulto , Anciano , Diente Premolar/patología , Color , Resinas Compuestas/química , Adaptación Marginal Dental , Materiales Dentales/química , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Recubrimientos Dentinarios/química , Femenino , Estudios de Seguimiento , Humanos , Incrustaciones/clasificación , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Diente Molar/patología , Estudios Prospectivos , Cementos de Resina/química , Propiedades de Superficie , Resultado del Tratamiento
14.
Clin Oral Investig ; 12(1): 53-9, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17690921

RESUMEN

The aim of this study was to evaluate the influence of different cavity preparation designs on marginal accuracy of laboratory-processed resin composite restored teeth. Eighty mandibular human third molars were selected. There were two experimental factors, occlusal isthmus width (narrow vs wide) and cuspal coverage (inlay, one-cusp onlay, two-cusp onlay, and all-cusp onlay), resulting on eight groups (N = 10). Indirect composite restorations (SR Adoro, Ivoclar-Vivadent) were manufactured and positioned over each respective preparation. Marginal accuracy evaluation was accomplished using a stereomicroscope at three points on buccal, lingual, mesial, and distal regions with 40x magnification. The results showed significant differences (P = 0.00) with wide inlay showing the best overall marginal accuracy and narrow inlay the worst one. Two-way analysis of variance (ANOVA) showed significant differences when considering the factor occlusal isthmus width (P = 0.00). In general, preparations with wide occlusal isthmus presented better results than narrow ones, except for wide all-cusp onlays; however, the test failed to show differences when considering the cuspal coverage (P = 0.42) or the interaction between both factors (P = 0.30). The effect of occlusal width extension on marginal accuracy of indirect composite resin restorations is significant, with lower values of gaps width in wide preparations, but since in a clinical situation this would mean greater removal of sound tooth structure, less-aggressive preparations combined with other restorative procedures seem to be more feasible.


Asunto(s)
Resinas Compuestas/química , Preparación de la Cavidad Dental/métodos , Adaptación Marginal Dental , Restauración Dental Permanente/métodos , Preparación de la Cavidad Dental/clasificación , Técnica de Impresión Dental , Restauración Dental Permanente/clasificación , Humanos , Incrustaciones/clasificación , Ensayo de Materiales , Tercer Molar , Propiedades de Superficie
15.
J Dent Res ; 85(12): 1097-100, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17122161

RESUMEN

Wear phenomena of ceramic inlays are not fully understood. The aim of the present study was to evaluate ceramic wear, antagonist enamel wear, and luting cement wear over 8 years. The two-fold null hypothesis was that there would be (1) no difference in wear behavior between ceramic and enamel, and (2) no influence of filler content of luting composites on composite wear. From 96 restorations, 36 Class II inlays from 16 participants were selected. For inlays with opposing enamel cusps (n=17), replicas of inlays and enamel were scanned with a 3-D laser scanner. Luting gaps of inlays (n=36) were analyzed with a profilometer, including 3-D data analysis. Ceramic and enamel wear increased between 4 and 8 years, with significantly higher values for enamel after 6 years (p<0.05). Luting gap wear increased continuously up to 8 years (p<0.05), with no influence of luting composites (p>0.05) and location of teeth (p>0.05).


Asunto(s)
Esmalte Dental/patología , Porcelana Dental/química , Alisadura de la Restauración Dental , Incrustaciones , Cementos de Resina/química , Abrasión de los Dientes/patología , Adulto , Silicatos de Aluminio/química , Diente Premolar/patología , Resinas Compuestas/química , Alisadura de la Restauración Dental/clasificación , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Incrustaciones/clasificación , Rayos Láser , Masculino , Diente Molar/patología , Técnicas de Réplica , Propiedades de Superficie
16.
J Prosthet Dent ; 95(6): 421-9, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16765154

RESUMEN

STATEMENT OF PROBLEM: Controversy exists concerning the preferred cavity design for posterior ceramic restorations to improve their resistance to fracture under occlusal load. PURPOSE: The aim of this study was to assess the resistance to fracture of leucite-reinforced ceramic restorations placed on molars with different cavity preparation designs. MATERIAL AND METHODS: Ninety noncarious molars were selected, stored in 0.2% thymol solution, and divided into 9 groups (n = 10): IT, intact teeth; CsI, conservative inlay; ExI, extensive inlay; CsO/mb, conservative onlay with mesio-buccal cusp coverage; ExO/mb, entensive onlay with mesio-buccal cusp coverage; CsO/b, conservative onlay with buccal cusp coverage; ExO/b, entensive onlay with buccal cusp coverage; CsO/t, conservative onlay with total cusp coverage; ExO/t, extensive onlay with total cusp coverage. Teeth were restored with a Leucite-reinforced ceramic (Cergogold). The fracture resistance (N) was assessed under compressive load in a universal testing machine. The data were analyzed with 1-way and 2-way analyses of variance, followed by the Tukey HSD test (alpha = .05). Fracture modes were recorded, based on the degree of tooth structure and restoration damage. RESULTS: One-way analysis showed that intact teeth had the highest fracture resistance values. Two-way analyses showed no significant differences for the isthmus extention factor, but showed a significant difference for the preparation design type of fracture (P = .03), and also for the interaction between both factors (P = .013). The fracture mode observed in all groups tended to involve only restorations. CONCLUSION: Within the limitations of this study, it was observed that cuspal coverage does not increase fracture resistance of the posterior tooth-restoration complex restored with leucite-reinforced ceramics.


Asunto(s)
Silicatos de Aluminio/química , Cerámica/química , Preparación de la Cavidad Dental/métodos , Fracaso de la Restauración Dental , Incrustaciones , Fuerza de la Mordida , Preparación de la Cavidad Dental/clasificación , Porcelana Dental/química , Diseño de Prótesis Dental , Análisis del Estrés Dental/instrumentación , Humanos , Incrustaciones/clasificación , Ensayo de Materiales , Diente Molar , Estrés Mecánico , Propiedades de Superficie , Diente/fisiopatología
17.
Acta Odontol Scand ; 63(4): 205-12, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16040442

RESUMEN

OBJECTIVE: The aim of the present study was to investigate the effect of manual and ultrasonic insertion of standardized class I inlays (Cerana) using three composite resin materials of different viscosity (Tetric Flow, Tetric, and Tetric Ceram) on time to seat inlays, film thickness, and filler distribution within the materials. METHODS: In a preliminary test, mean loads for manual and ultrasonic insertion were measured using the high viscosity composite resin material (Tetric Ceram). These loads were then applied with all composite resin materials to evaluate the times required to seat the inlays. In addition, film thickness was assessed using scanning electron microscopy, and filler distribution (wt% silicon, barium, ytterbium) was monitored using energy-dispersive spectroscopy. RESULTS: Ultrasonic insertion significantly reduced mean load applied to seat inlays (6.4+/-1.4 N; mean+/-SD) as compared to manual insertion (18.9+/-3.1 N; p < 0.001). Using an ultrasonic device, times for insertion values were significantly lower in the high and medium viscosity composite resin material groups compared to manual insertion (p < 0.05). The widest film thickness was recorded for the high viscosity composite resin material in combination with manual insertion (p < 0.05). However, when ultrasound was applied, there was no difference in film thickness between the three materials at any levels. Furthermore, the analysis of filler distribution revealed no significant differences between groups. CONCLUSION: Highly filled viscous composite resin materials may be used in combination with the ultrasonic insertion technique without untoward effects on film thickness or filler distribution.


Asunto(s)
Resinas Compuestas/química , Preparación de la Cavidad Dental/clasificación , Adaptación Marginal Dental , Incrustaciones/métodos , Bario/química , Cerámica/química , Materiales Dentales/química , Microanálisis por Sonda Electrónica , Humanos , Incrustaciones/clasificación , Microscopía Electrónica de Rastreo , Silicio/química , Estrés Mecánico , Propiedades de Superficie , Factores de Tiempo , Ultrasonido , Viscosidad , Iterbio/química
18.
Oper Dent ; 29(1): 3-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14753325

RESUMEN

The objectives of this study include establishing a method for quantitative measurement of marginal change in ceramic inlays and clarifying their marginal disintegration in vivo. An accurate CCD optical laser scanner system was used for morphological measurement of the marginal change of ceramic inlays. The accuracy of the CCD measurement was assessed by comparing it with microscopic measurement. Replicas of 15 premolars restored with Class II ceramic inlays at the time of placement and eight years after restoration were used for morphological measurement by means of the CCD laser scanner system. Occlusal surfaces of the restored teeth were scanned and cross-sections of marginal areas were computed with software. Marginal change was defined as the area enclosed by two profiles obtained by superimposing two cross-sections of the same location at two different times and expressing the maximum depth and mean area of the area enclosed. The accuracy of this method of measurement was 4.3 +/- 3.2 microm in distance and 2.0 +/- 0.6% in area. Quantitative marginal changes for the eight-year period were 10 x 10 microm in depth and 50 x 10(3) microm2 in area at the functional cusp area and 7 x 10 microm in depth and 28 x 10(3) microm2 in area at the non-functional cusp area. Marginal disintegration at the functional cusp area was significantly greater than at the non-functional cusp area (Wilcoxon signed-ranks test, p < 0.05). This study constitutes a quantitative measurement of in vivo deterioration in marginal adaptation of ceramic inlays and indicates that occlusal force may accelerate marginal disintegration.


Asunto(s)
Cerámica/química , Porcelana Dental/química , Incrustaciones , Silicatos de Aluminio/química , Diente Premolar/patología , Resinas Compuestas/química , Esmalte Dental/patología , Adaptación Marginal Dental , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Incrustaciones/clasificación , Rayos Láser , Óptica y Fotónica/instrumentación , Compuestos de Potasio/química , Cementos de Resina/química , Estadísticas no Paramétricas , Propiedades de Superficie
19.
J Esthet Restor Dent ; 15(6): 338-51; discussion 352, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14982661

RESUMEN

UNLABELLED: The use of ceramics as restorative materials has increased substantially in the past two decades. This trend can be attributed to the greater interest of patients and dentists in this esthetic and long-lasting material, and to the ability to effectively bond metal-free ceramic restorations to tooth structure using acid-etch techniques and adhesive cements. The purpose of this article is to review the pertinent literature on ceramic systems, direct internal buildup materials, and adhesive cements. Current clinical procedures for the planning, preparation, impression, and bonding of ceramic inlays and onlays are also briefly reviewed. A representative clinical case is presented, illustrating the technique. CLINICAL SIGNIFICANCE: When posterior teeth are weakened owing to the need for wide cavity preparations, the success of direct resin-based composites is compromised. In these clinical situations, ceramic inlays/onlays can be used to achieve esthetic, durable, and biologically compatible posterior restorations.


Asunto(s)
Cerámica/química , Materiales Dentales/química , Incrustaciones , Materiales Biocompatibles/química , Humanos , Incrustaciones/clasificación , Incrustaciones/métodos , Resultado del Tratamiento
20.
Gen Dent ; 51(5): 450-4, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-15055635

RESUMEN

In response to an increased public demand for esthetic restorations, dentists are using computer-aided design/computer-aided manufacture (CAD/CAM) technology to fabricate inlay/onlay, crown, and laminate veneers. This study evaluated the fit at the gingival margin of surface inlay restorations milled by the CEREC II as well as the more recently developed CEREC III. The marginal fit of inlays milled by the CEREC III was more accurate than the fit of those milled by the CEREC II, although both were within the ADA specifications of 50 micro.


Asunto(s)
Cerámica/química , Diseño Asistido por Computadora , Porcelana Dental/química , Incrustaciones , Acetona/química , Grabado Ácido Dental , Preparación de la Cavidad Dental/clasificación , Adaptación Marginal Dental , Humanos , Incrustaciones/clasificación , Microscopía Electrónica de Rastreo , Ácidos Polimetacrílicos/química , Cementos de Resina/química , Silanos/química , Propiedades de Superficie , Cuello del Diente/ultraestructura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA