Radiother Oncol ; 197: 110366, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38830537

RESUMEN

As a component of myeloablative conditioning before allogeneic hematopoietic stem cell transplantation (HSCT), Total Body Irradiation (TBI) is employed in radiotherapy centers all over the world. In recent and coming years, many centers are changing their technical setup from a conventional TBI technique to multi-isocenter conformal arc therapy techniques such as Volumetric Modulated Arc Therapy (VMAT) or Helical Tomotherapy (HT). These techniques allow better homogeneity and control of the target prescription dose, and provide more freedom for individualized organ-at-risk sparing. The technical design of multi-isocenter/multi-plan conformal TBI is complex and should be developed carefully. A group of early adopters with conformal TBI experience using different treatment machines and treatment planning systems came together to develop technical recommendations and share experiences, in order to assist departments wishing to implement conformal TBI, and to provide ideas for standardization of practices.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Irradiación Corporal Total , Humanos , Radioterapia de Intensidad Modulada/métodos , Radioterapia de Intensidad Modulada/normas , Irradiación Corporal Total/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Dosificación Radioterapéutica , Trasplante de Células Madre Hematopoyéticas/métodos , Órganos en Riesgo/efectos de la radiación
2.
Biomed Phys Eng Express ; 10(4)2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38788700

RESUMEN

Objective.In myeloablative total body irradiation (TBI), lung shielding blocks are used to reduce the dose to the lungs and hence decrease the risk of radiation pneumonitis. Some centers are still using mega-Volt (MV) imaging with dedicated silver halide-based films during simulation and treatment for lung delineation and position verification. However, the availability of these films has recently become an issue. This study examines the clinical performance of a computed radiography (CR) solution in comparison to radiographic films and potential improvement of image quality by filtering and post-processing.Approach.We compared BaFBrI-based CR plates to radiographic films. First, images of an aluminum block were analyzed to assess filter impact on scatter reduction. Secondly, a dedicated image quality phantom was used to assess signal linearity, signal-to-noise ratio (SNR), contrast and spatial resolution. Ultimately, a clinical performance study involving two impartial observers was conducted on an anthropomorphic chest phantom, employing visual grading analysis (VGA). Various filter materials and positions as well as post-processing were examined, and the workflow between CR and film was compared.Main results.CR images exhibited high SNR and linearity but demonstrated lower spatial and contrast resolution when compared to film. However, filtering improved contrast resolution and SNR, while positioning filters inside the cassette additionally enhanced sharpness. Image processing improved VGA scores, while additional filtering also resulted in higher spine visibility scores. CR shortened TBI simulation by over 10 minutes for one patient, alongside a dose reduction by order of 0.1 Gy.Significance.This study highlights potential advantages of shifting from conventional radiographic film to CR for TBI. Overall, CR with the incorporation of processing and filtering proves to be suitable for TBI chest imaging. When compared to radiographic film, CR offers advantages such as reduced simulation time and dose delivery, re-usability of image plates and digital workflow integration.


Asunto(s)
Estudios de Factibilidad , Fantasmas de Imagen , Radiografía Torácica , Relación Señal-Ruido , Irradiación Corporal Total , Humanos , Irradiación Corporal Total/métodos , Radiografía Torácica/métodos , Pulmón/diagnóstico por imagen , Pulmón/efectos de la radiación , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador/métodos
3.
J Appl Clin Med Phys ; 25(2): e14188, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37910646

RESUMEN

This work presents the dosimetric characteristics of Total Body Irradiation (TBI) delivered using a dedicated Co-60 TBI unit. We demonstrate the ability to deliver a uniform dose to the entire patient without the need for a beam spoiler or patient-specific compensation. Full dose distributions are calculated using an in-house Monte Carlo treatment planning system, and cumulative dose distributions are created by deforming the dose distributions within two different patient orientations. Sample dose distributions and profiles are provided to illustrate the plan characteristics, and dose and DVH statistics are provided for a heterogeneous cohort of patients. The patient cohort includes adult and pediatric patients with a range of 132-198 cm in length and 16.5-37.5 cm in anterior-posterior thickness. With the exception of the lungs, a uniform dose of 12 Gy is delivered to the patient with nearly the entire volume receiving a dose within 10% of the prescription dose. Mean lung doses (MLDs) are maintained below the estimated threshold for radiation pneumonitis, with MLDs ranging from 7.3 to 9.3 Gy (estimated equivalent dose in 2 Gy fractions (EQD2 ) of 6.2-8.5 Gy). Dose uniformity is demonstrated across five anatomical locations within the patient for which mean doses are all within 3.1% of the prescription dose. In-vivo dosimetry demonstrates excellent agreement between measured and calculated doses, with 78% of measurements within ±5% of the calculated dose and 99% within ±10%. These results demonstrate a state-of-the-art TBI planning and delivery system using a dedicated TBI unit and hybrid in-house and commercial planning techniques which provide comprehensive dosimetric data for TBI treatment plans that are accurately verified using in-vivo dosimetry.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Irradiación Corporal Total , Adulto , Humanos , Niño , Irradiación Corporal Total/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioisótopos de Cobalto/uso terapéutico , Radiometría/métodos
4.
J Med Imaging Radiat Oncol ; 67(6): 684-690, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37343142

RESUMEN

INTRODUCTION: Total body irradiation (TBI) practices vary considerably amongst centres, and the risk of treatment related toxicities remains unclear. We report lung doses for 142 TBI patients who underwent either standing TBI with lung shield blocks or lying TBI without blocks. METHODS: Lung doses were calculated for 142 TBI patients treated between June 2016 and June 2021. Patients were planned using Eclipse (Varian Medical Systems) using AAA_15.6.06 for photon dose calculations and EMC_15.6.06 for electron chest wall boost fields. Mean and maximum lung doses were calculated. RESULTS: Thirty-seven patients (26.2%) were treated standing using lung shielding blocks with 104 (73.8%) treated lying down. Lowest relative mean lung doses were achieved using lung shielding blocks in standing TBI, reducing the mean lung doses to 75.2% of prescription (9.9 Gy), ±4.1% (range 68.6-84.1%) for a prescribed dose of 13.2 Gy in 11 fractions, including contributions from electron chest wall boost fields, compared to 12 Gy in 6 fraction lying TBI receiving 101.6% mean lung dose (12.2 Gy) ±2.4% (range 95.2-109.5%) (P ≪ 0.05). Patients treated lying down with 2 Gy single fraction received the highest relative mean lung dose on average, with 108.4% (2.2 Gy) ±2.6% of prescription (range 103.2-114.4%). CONCLUSION: Lung doses have been reported for 142 TBI patients using the lying and standing techniques described herein. Lung shielding blocks significantly reduced mean lung doses despite the addition of electron boost fields to the chest wall.


Asunto(s)
Neoplasias Hematológicas , Irradiación Corporal Total , Humanos , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos , Pulmón , Neoplasias Hematológicas/etiología , Neoplasias Hematológicas/terapia , Dosificación Radioterapéutica
5.
BMJ Open ; 13(6): e067790, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37263700

RESUMEN

INTRODUCTION: The usage of a T-cell depleted, reduced intensity conditioning (RIC) approach to haematopoietic cell transplantation (HCT) in adult patients with acute lymphoblastic leukaemia (ALL) over 40 years of age and in first complete remission (CR) has resulted in encouraging rates of event-free and overall survival in a population of adults with high risk disease. However, relapse rates remain high-with disease progression being the major cause of treatment failure. Using different, more powerful conditioning approaches is the logical next step in examining the role of RIC allogeneic HCT in adult ALL. METHODS AND ANALYSIS: The ALL-RIC trial is a two-arm, phase II, multicentre, randomised clinical trial in adult patients with ALL in first or second CR, who are undergoing allogeneic HCT. Comparison of a novel RIC transplant conditioning regimen using reduced-dose total body irradiation (TBI), cyclophosphamide and alemtuzumab, is made against a standardised RIC approach using fludarabine, melphalan and alemtuzumab. The primary outcome of the study is disease-free survival at 3 years, defined as time from randomisation to the first of either relapse or death from any cause. Patients who are still alive and progression-free at the end of the trial will be censored at their last date known to be alive. Secondary outcomes include overall survival and non-relapse mortality. ETHICS AND DISSEMINATION: The protocol was approved by the East Midlands-Leicester Central Research Ethics committee (18/EM/0112). Initial approval was received on 12 June 2018. Current protocol version (V.6.0) approval obtained on 18 November 2019. The Medicines and Healthcare products Regulatory Agency (MHRA) also approved all protocol versions. The results of this trial will be disseminated through national and international presentations and peer-reviewed publications. TRIAL REGISTRATION NUMBER: EudraCT Number: 2017-004800-23.ISRCTN99927695.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Leucemia-Linfoma Linfoblástico de Células Precursoras , Adulto , Humanos , Persona de Mediana Edad , Melfalán/uso terapéutico , Alemtuzumab , Irradiación Corporal Total/métodos , Recurrencia Local de Neoplasia/tratamiento farmacológico , Ciclofosfamida/uso terapéutico , Trasplante de Células Madre Hematopoyéticas/métodos , Enfermedad Aguda , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamiento farmacológico , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto , Ensayos Clínicos Fase II como Asunto
6.
Surg Oncol Clin N Am ; 32(3): 475-495, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37182988

RESUMEN

The development of large-field intensity-modulated radiation therapy (IMRT) has enabled the implementation of total marrow irradiation (TMI), total marrow and lymphoid irradiation (TMLI), and IMRT total body irradiation (TBI). IMRT TBI limits doses to organs at risk, primarily the lungs and in some cases the kidneys and lenses, which may mitigate complications. TMI/TMLI allows for dose escalation above TBI radiation therapy doses to malignant sites while still sparing organs at risk. Although still sparingly used, these techniques have established feasibility and demonstrated promise in reducing the adverse effects of TBI while maintaining and potentially improving survival outcomes.


Asunto(s)
Médula Ósea , Radioterapia de Intensidad Modulada , Humanos , Médula Ósea/efectos de la radiación , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos , Irradiación Linfática/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Dosificación Radioterapéutica , Trasplante de Células Madre
7.
Mol Omics ; 19(6): 492-503, 2023 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-37098727

RESUMEN

Despite some advances in the study of radiation injuries, effective methods of prevention and treatment of severe acute radiation syndrome or illness (ARS) are still lacking. Therefore, an in-depth understanding of the biological characteristics associated with high dose radiation is essential to reveal the mechanisms underlying the varied biological processes following high dose radiation and the development of novel potent radioprotective agents. In the present study, plasma metabolic characteristics were investigated using hematopoietic stem cell transplantation patients (n = 36) undergoing total body ionizing irradiation (TBI) utilizing gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). Plasma was collected pre-irradiation, 3 days after completion of fractionated radiation therapy with a total dose of 12 Gy delivered at a dose rate of 8 cGy min-1. These metabolic disorders involve the dysregulation of the gut microflora, a shift in energy supply from aerobic respiration toward ketogenesis, protein synthesis and metabolism in response to TBI. Furthermore, the panel of four metabolic markers with most potential consisting of PC (O-38:5), urate, ornithine, and GCDCS for radiation injury was chosen by combining multiple methods of data processing that included univariate analysis, partial least squares discriminant analysis (PLS-DA), and multivariable stepwise linear regression analysis. While similar patterns of metabolic alterations were observed in patients of different genders, disease types and ages, specific changes were also found in specific patients following high doses of exposure. These findings provide valuable information for selecting metabolic biomarker panels for radiation injury, clues for radiation pathology and therapeutic interventions involved in high-dose radiation exposure.


Asunto(s)
Síndrome de Radiación Aguda , Irradiación Corporal Total , Humanos , Masculino , Femenino , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos , Metabolómica , Síndrome de Radiación Aguda/etiología , Síndrome de Radiación Aguda/patología , Espectrometría de Masas , Cromatografía de Gases y Espectrometría de Masas
8.
J Cancer Res Clin Oncol ; 149(10): 7007-7015, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36856852

RESUMEN

BACKGROUND: Intensity-modulated helical tomotherapy (HT) is a promising technique in preparation for bone marrow transplantation. Nevertheless, radiation-sensitive organs can be substantially compromised due to suboptimal delivery techniques of total body irradiation (TBI). To reduce the potential burden of radiation toxicity to organs at risk (OAR), high-quality coverage and homogeneity are essential. We investigated dosimetric data from kidney, lung and thorax, liver, and spleen in relation to peripheral blood kinetics. To further advance intensity-modulated total body irradiation (TBI), the potential for dose reduction to lung and kidney was considered in the analysis. PATIENTS AND METHODS: 46 patients undergoing TBI were included in this analysis, partially divided into dose groups (2, 4, 8, and 12 Gy). HT was performed using a rotating gantry to ensuring optimal reduction of radiation to the lungs and kidneys and to provide optimal coverage of other OAR. Common dosimetric parameters, such as D05, D95, and D50, were calculated and analysed. Leukocytes, neutrophils, platelets, creatinine, GFR, haemoglobin, overall survival, and graft-versus-host disease were related to the dosimetric evaluation using statistical tests. RESULTS: The mean D95 of the lung is 48.23%, less than half the prescribed and unreduced dose. The D95 of the chest is almost twice as high at 84.95%. Overall liver coverage values ranged from 96.79% for D95 to 107% for D05. The average dose sparing of all patients analysed resulted in an average D95 of 68.64% in the right kidney and 69.31% in the left kidney. Average D95 in the spleen was 94.28% and D05 was 107.05%. Homogeneity indexes ranged from 1.12 for liver to 2.28 for lung. The additional significance analyses conducted on these blood kinetics showed a significant difference between the 2 Gray group and the other three groups for leukocyte counts. Further statistical comparisons of the dose groups showed no significant differences. However, there were significant changes in the dose of OAR prescribed with dose sparing (e.g., lung vs. rib and kidney). CONCLUSION: Using intensity-modulated helical tomotherapy to deliver TBI is a feasible method in preparation for haematopoietic stem cell transplantation. Significant dose sparing in radiosensitive organs such as the lungs and kidneys is achievable with good overall quality of coverage. Peripheral blood kinetics support the positive impact of HT and its advantages strongly encourage its implementation within clinical routine.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Irradiación Corporal Total/métodos , Órganos en Riesgo/efectos de la radiación , Cinética , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
9.
Pract Radiat Oncol ; 13(4): e365-e369, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36871886

RESUMEN

PURPOSE: Total body irradiation (TBI), a form of immunomodulation, improves treatment outcomes for rapidly progressive scleroderma. The landmark Scleroderma: Cyclophosphamide or Transplantation (SCOT) trial used strict 200-cGy lung and kidney dose restrictions to limit the likelihood of normal tissue toxicity. The protocol as written did not specify how or where the 200-cGy limit was to be measured, opening the door to variable techniques and outcomes. METHODS AND MATERIALS: Following the SCOT protocol, a validated 18-MV TBI beam model was used to evaluate lung and kidney doses with varying Cerrobend half-value layers (HVLs). Block margins were constructed per the SCOT protocol. RESULTS: Using the 2 HVL SCOT block guidelines, the average central point dose under the lung block center was 353 (±27) cGy, almost double the mandated 200 cGy. The mean lung dose was 629 (±30) cGy, triple the mandated 200 cGy. No block thickness could achieve the mandated 2 Gy due to contribution from unblocked peripheral lung tissue. With 2 HVLs, the average kidney dose was 267 (±7) cGy. Three HVLs were needed to reduce it <200 cGy, meeting the mandated SCOT limit. CONCLUSIONS: There is considerable ambiguity (and inaccuracy) in lung and kidney dose modulation for TBI. It is not possible to achieve the mandated lung doses using the protocol-specified block parameters. Future investigators are encouraged to take these findings into account to develop more explicit, achievable, reproducible, and accurate TBI methodology.


Asunto(s)
Pulmón , Irradiación Corporal Total , Humanos , Irradiación Corporal Total/métodos , Pulmón/efectos de la radiación , Ciclofosfamida , Trasplante de Médula Ósea , Riñón
10.
Int J Mol Sci ; 24(5)2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36901922

RESUMEN

For widespread cutaneous lymphoma, such as mycosis fungoides or leukemia cutis, in patients with acute myeloid leukemia (AML) and for chronic myeloproliferative diseases, total skin irradiation is an efficient treatment modality for disease control. Total skin irradiation aims to homogeneously irradiate the skin of the entire body. However, the natural geometric shape and skin folding of the human body pose challenges to treatment. This article introduces treatment techniques and the evolution of total skin irradiation. Articles on total skin irradiation by helical tomotherapy and the advantages of total skin irradiation by helical tomotherapy are reviewed. Differences among each treatment technique and treatment advantages are compared. Adverse treatment effects and clinical care during irradiation and possible dose regimens are mentioned for future prospects of total skin irradiation.


Asunto(s)
Leucemia , Linfoma Cutáneo de Células T , Micosis Fungoide , Radioterapia de Intensidad Modulada , Neoplasias Cutáneas , Humanos , Neoplasias Cutáneas/radioterapia , Radioterapia de Intensidad Modulada/métodos , Leucemia/terapia , Dosificación Radioterapéutica , Irradiación Corporal Total/métodos
11.
J Cancer Res Clin Oncol ; 149(9): 5965-5973, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36607428

RESUMEN

BACKGROUND: Total body irradiation (TBI) is often a component of the conditioning regimen prior to hematopoietic stem cell transplantation in patients with hematological malignancies. However, total marrow irradiation (TMI) could be an alternative method for reducing radiation therapy-associated toxicity, as it specifically targets the skeleton and thus could better protect organs at risk. Here, we compared dosimetric changes in irradiation received by the target volume and organs at risk between TBI and TMI plans. MATERIALS AND METHODS: Theoretical TMI plans were calculated for 35 patients with various hematological malignancies who had already received TBI in our clinic. We then statistically compared irradiation doses between the new TMI plans and existing TBI plans. We examined whether TMI provides greater protection of organs at risk while maintaining the prescribed dose in the targeted skeletal area. We also compared beam-on times between TBI and TMI. RESULTS: TMI planning achieved significant reductions in the mean, minimum, and maximum irradiation doses in the lungs, kidneys, liver, spleen, and body (i.e., remaining tissue except organs and skeleton). In particular, the mean dose was reduced by 49% in the liver and spleen and by 55-59% in the kidneys. Moreover, TMI planning reduced the corpus beam-on time by an average of 217 s. CONCLUSION: TMI planning achieved significant dose reduction in organs at risk while still achieving the prescribed dose in the target volume. Additionally, TMI planning reduced the beam-on time for corpus plans despite a high modulation factor.


Asunto(s)
Neoplasias Hematológicas , Traumatismos por Radiación , Radioterapia de Intensidad Modulada , Humanos , Irradiación Corporal Total/métodos , Médula Ósea , Radioterapia de Intensidad Modulada/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Carmustina , Etopósido
12.
Br J Radiol ; 96(1144): 20220650, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36475820

RESUMEN

The use of volumetric arc therapy and inverse planning has been in routine use in radiotherapy for two decades. However, use in total body irradiation (TBI) has been more recent and few guidelines exist as to how to plan or verify. This has led to heterogeneous approaches. The goal of this review is to provide an overview of current advanced planning and dosimetry verification protocols used in optimised conformal TBI as a basis for investigating the need for greater standardisation in TBI.


Asunto(s)
Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Irradiación Corporal Total/métodos
13.
Radiat Environ Biophys ; 62(1): 73-81, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36269391

RESUMEN

The aim of this study was to dosimetrically compare three total body irradiation (TBI) techniques which can be delivered by a standard linear accelerator, and to deduce which one is preferable. Specifically, Extended Source to Surface Distance (SSD) Field-in-Field (FiF), Extended SSD Volumetric Modulated Arc Therapy (VMAT), and Standard SSD VMAT TBI techniques were dosimetrically evaluated. Percent depth dose and dose profile measurements were made under treatment conditions for each specified technique. After having generated treatment plans with a treatment planning system (TPS), dose homogeneity and critical organ doses were investigated on a Rando phantom using radiochromic films and optically stimulated luminescence dosimeters (OSLDs). TBI dose of 12 Gy in six fractions was prescribed for each technique. The gamma index (5%/5 mm) was used for the analysis of radiochromic films. Passing rates for Extended SSD FiF, Extended SSD VMAT and Standard SSD VMAT techniques were found to be 90%, 87% and 94%, respectively. OSLD measurements were within ± 5% agreement with TPS calculations for the first two techniques whereas the agreement was found to be within ± 3% for the Standard SSD VMAT technique. TPS calculations demonstrated that mean lung doses in the first two techniques were around 8.5 Gy while it was kept around 7 Gy in Standard SSD VMAT. It is concluded that Standard SSD VMAT is superior in sparing the lung tissue while all three TBI techniques are feasible in clinical practice with acceptable dose homogeneity. In the absence of VMAT-based treatment planning, Extended SSD FiF would be a reasonable choice compared to other conventional techniques.


Asunto(s)
Radioterapia de Intensidad Modulada , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Irradiación Corporal Total/métodos , Radiometría/métodos , Órganos en Riesgo/efectos de la radiación
14.
Int J Radiat Oncol Biol Phys ; 115(3): 677-685, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36174802

RESUMEN

PURPOSE: A second intensification is an option at first relapse in multiple myeloma (MM) after more than 36 months of initial remission. Many conditioning regimens have been tested, with or without total body irradiation (TBI). Recently, it was found that TBI could be replaced by total marrow irradiation (TMI) using helical tomotherapy, with promising results. METHODS AND MATERIALS: This study was a prospective multicenter phase 1 trial that aimed to determine the maximum tolerated dose (MTD) of TMI administered in association with melphalan 140 mg/m², followed by autologous stem cell transplantation as consolidation at first relapse in MM. Four dose levels were explored: 8 Gy, 10 Gy, 12 Gy, and 14 Gy. The dose-limiting toxicity (DLT) was defined as grade 4 neutropenia >15 days, grade 4 thrombopenia >28 days, and all other grade 4 nonhematologic toxic effects except nausea, vomiting, alopecia, mucositis, and reaction to autologous stem cell infusion. RESULTS: Thirteen patients were included; only 1 DLT at the third escalated dose level (12 Gy) was observed, whereas 1 patient was treated at 14 Gy with no adverse events. The MTD was not reached. The rate of acute toxicity was low: 38% of grade 3-4 diarrhea, mucositis, or unexplained fever. Regarding the lungs, the mean dose administered was systematically less than 8 Gy. After a median follow-up of 55 months, 70% of participants were alive. Of these 13 patients, 38.5% were in very good partial response and 30.8% were in complete response. Three of them were progression-free. Six patients were long survivors, still alive after 55 months of follow-up. CONCLUSIONS: Total marrow irradiation provides good results with a good tolerance profile at first relapse in MM and makes it possible to increase the dose delivered to the planning target volume while sparing organs at risk. This technique could be discussed for all regimens before auto- or allo-stem cell rescue when TBI is required.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Mucositis , Mieloma Múltiple , Radioterapia de Intensidad Modulada , Humanos , Mieloma Múltiple/terapia , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Melfalán/efectos adversos , Médula Ósea/efectos de la radiación , Radioterapia de Intensidad Modulada/efectos adversos , Mucositis/etiología , Estudios Prospectivos , Trasplante Autólogo , Recurrencia , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos
15.
Eur J Med Res ; 27(1): 287, 2022 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-36496388

RESUMEN

PURPOSE: Helical tomotherapy (HT) is a viable method for delivering total body irradiation (TBI) when preparing patients for allogenic stem cell or bone-marrow transplantation. TBI can be planned to reduce the amount of radiation delivered to organs at risk, such as the lungs, with the aim of decreasing toxicity. However, it is important for the ribcage to receive the prescribed radiation dose in preparation for bone-marrow transplantation. In this retrospective study, we analyzed radiation dose coverage of the lungs and ribcage in patients who underwent TBI delivered by HT to achieve lung dose sparing. METHODS: Thirty-five patients were included in the analysis and divided into three groups based on their prescribed radiation dose (4, 8, or 12 Gy). HT was performed using a rotating gantry to reduce radiation to the lungs. Dosimetric parameters for the lungs and ribcage as well as dose-volume histograms were calculated. RESULTS: The mean lung D95 was 60.97%, 54.77%, and 37.44% of the prescribed dose for patients receiving 4 Gy, 8 Gy, and 12 Gy, respectively. Ribcage coverage was most optimal for patients receiving 4 Gy, with a D95 of 91.27% and mean homogeneity index of 1.17, whereas patients receiving 12 Gy had a mean D95 of 78.65% and homogeneity index of 1.37, which is still within the range recommended by treatment guidelines. CONCLUSIONS: Using HT to achieve lung tissue sparing is a viable approach to minimizing pulmonic complications in patients undergoing TBI. As this planning adjustment does not compromise the dose and quality of coverage received by the ribcage, it is a feasible tool within conditioning regimens for allogeneic bone-marrow transplantation.


Asunto(s)
Radioterapia de Intensidad Modulada , Irradiación Corporal Total , Humanos , Irradiación Corporal Total/métodos , Dosificación Radioterapéutica , Estudios Retrospectivos , Radioterapia de Intensidad Modulada/métodos , Pulmón
16.
Radiother Oncol ; 173: 119-133, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35661674

RESUMEN

BACKGROUND AND PURPOSE: Myeloablative Total Body Irradiation (TBI) is an important modality in conditioning for allogeneic hematopoietic stem cell transplantation (HSCT), especially in children with high-risk acute lymphoblastic leukemia (ALL). TBI practices are heterogeneous and institution-specific. Since TBI is associated with multiple late adverse effects, recommendations may help to standardize practices and improve the outcome versus toxicity ratio for children. MATERIAL AND METHODS: The European Society for Paediatric Oncology (SIOPE) Radiotherapy TBI Working Group together with ESTRO experts conducted a literature search and evaluation regarding myeloablative TBI techniques and toxicities in children. Findings were discussed in bimonthly virtual meetings and consensus recommendations were established. RESULTS: Myeloablative TBI in HSCT conditioning is mostly performed for high-risk ALL patients or patients with recurring hematologic malignancies. TBI is discouraged in children <3-4 years old because of increased toxicity risk. Publications regarding TBI are mostly retrospective studies with level III-IV evidence. Preferential TBI dose in children is 12-14.4 Gy in 1.6-2 Gy fractions b.i.d. Dose reduction should be considered for the lungs to <8 Gy, for the kidneys to ≤10 Gy, and for the lenses to <12 Gy, for dose rates ≥6 cGy/min. Highly conformal techniques i.e. TomoTherapy and VMAT TBI or Total Marrow (and/or Lymphoid) Irradiation as implemented in several centers, improve dose homogeneity and organ sparing, and should be evaluated in studies. CONCLUSIONS: These ESTRO ACROP SIOPE recommendations provide expert consensus for conventional and highly conformal myeloablative TBI in children, as well as a supporting literature overview of TBI techniques and toxicities.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Irradiación Corporal Total , Médula Ósea , Niño , Preescolar , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Trasplante de Células Madre Hematopoyéticas/métodos , Humanos , Estudios Retrospectivos , Acondicionamiento Pretrasplante/métodos , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos
17.
Pract Radiat Oncol ; 12(6): e476-e480, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35598860

RESUMEN

We present the case of a 56-year-old female with a diagnosis of acute T-cell lymphoblastic leukemia who received myeloablative conditioning for bone marrow transplant with total body irradiation (TBI) using volumetric modulated arc therapy (VMAT) to the upper body and anterior-posterior/posterior-anterior (AP/PA) open fields to the lower body followed by hematopoietic stem cell transplant. Her clinical course was complicated by high-grade pulmonary toxic effects 55 days after treatment that resulted in death. We discuss the case, planning considerations by radiation oncologists and radiation physicists, and the multidisciplinary medical management of this patient.


Asunto(s)
Radioterapia de Intensidad Modulada , Irradiación Corporal Total , Humanos , Femenino , Persona de Mediana Edad , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Acondicionamiento Pretrasplante/efectos adversos , Acondicionamiento Pretrasplante/métodos , Vidarabina/efectos adversos , Estudios Retrospectivos
18.
Pediatr Blood Cancer ; 69(6): e29689, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35373904

RESUMEN

INTRODUCTION: Total body irradiation (TBI) is an important component of many conditioning regimens for hematopoietic stem cell transplantation (HSCT), most commonly used in pediatric and adolescent/young adult (AYA) patients. We aimed to evaluate outcomes and toxicities among pediatric and AYA patients treated with TBI utilizing volumetric modulated arc therapy total body irradiation (VMAT-TBI). METHODS: We reviewed pediatric and AYA patients treated with VMAT-TBI at our institution from 2019 to 2021. Data on patient and disease characteristics, treatment details, outcomes and toxicities were collected. Overall survival (OS) and relapse-free survival (RFS) were analyzed using the Kaplan-Meier method. RESULTS: Among 38 patients, 16 (42.1%) were treated with myeloablative regimens and 22 (57.9%) with nonmyeloablative regimens. Median age was 7.2 years (range: 1-27) and median follow-up was 8.7 months (range: 1-21). Lungs Dmean was 7.3 ± 0.3 Gy for myeloablative regimens (range: 6.8-7.8). Kidneys were spared to average mean dose of 71.4 ± 4.8% of prescription dose. Gonadal sparing was achieved for patients treated for nonmalignant diseases to Dmean of 0.7 ± 0.1 Gy. No patient experienced primary graft failure; one (2.6%) experienced secondary graft failure. The most common grade 1-2 acute toxicities were nausea (68.4%) and fatigue (55.3%). Mucositis was the most common grade 3-4 acute toxicity, affecting 39.5% of patients. There were no cases of pneumonitis or nephrotoxicity attributable to TBI. CONCLUSION: VMAT-TBI offers increased ability to spare organs at risk in pediatric and AYA patients undergoing HSCT, with a favorable acute/subacute toxicity profile and excellent disease control.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Radioterapia de Intensidad Modulada , Adolescente , Niño , Humanos , Recurrencia Local de Neoplasia/etiología , Radioterapia de Intensidad Modulada/efectos adversos , Estudios Retrospectivos , Acondicionamiento Pretrasplante/efectos adversos , Acondicionamiento Pretrasplante/métodos , Irradiación Corporal Total/métodos , Adulto Joven
19.
J Appl Clin Med Phys ; 23(5): e13592, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35290701

RESUMEN

PURPOSE: Total body irradiation (TBI) in extended source surface distance (SSD) is a common treatment technique before hematopoietic stem cell transplant. The lungs are organs at risk, which often are treated with a lower dose than the whole body. METHODS: This can be achieved by the application of blocks. Three-dimensional (3D) printers are a modern tool to be used in the production process of these blocks. RESULTS: We demonstrate the applicability of a specific printer and printing material, describe the process, and evaluate the accuracy of the product. CONCLUSION: The blocks and apertures were found to be applicable in clinical routine.


Asunto(s)
Impresión Tridimensional , Irradiación Corporal Total , Humanos , Fantasmas de Imagen , Irradiación Corporal Total/métodos
20.
Pract Radiat Oncol ; 12(3): 245-258, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35182803

RESUMEN

PURPOSE: In this article, we describe the technical aspects of the Stanford volumetric modulated arc therapy (VMAT) total body irradiation (TBI) technique, compare it with other VMAT-TBI techniques, and share our initial experience. METHODS AND MATERIALS: From September 2019 to August 2021, 35 patients were treated with VMAT-TBI at our institution. Treatment planning was performed using in-house developed automated planning scripts. Organ sparing depended on the regimen: myeloablative (lungs, kidneys, and lenses) and nonmyeloablative with benign disease (lungs, kidneys, lenses, gonads, brain, and thyroid). Quality assurance was performed using electronic portal imaging device portal dosimetry and Mobius3D. Robustness was evaluated for the first 10 patients by performing local and global isocenter shifts of 5 mm. Treatment was delivered using image-guided radiation therapy for every isocenter and every fraction. In vivo measurements were performed on the match line between the VMAT and anterior-posterior/posterior-anterior fields and on the testes for the first fraction. RESULTS: The lungs, lungs - 1 cm, and kidneys Dmean were consistently spared to 57.6% ± 4.4%, 40.7% ± 5.5%, and 70.0% ± 9.9% of the prescription dose, respectively. Gonadal sparing (Dmean = 0.69 ± 0.13 Gy) was performed for all patients with benign disease. The average planning target volume (PTV) maximum dose to 1 cubic centimeter (D1cc) was 120.7% ± 6.4% for all patients. The average Gamma passing rate for the VMAT plans was 98.1% ± 1.6% (criterion of 3%/2 mm). Minimal differences were observed between Mobius3D- and Eclipse AAA-calculated PTV Dmean (0.0% ± 0.3%) and lungs Dmean (-2.5% ± 1.2%). Robustness evaluation showed that the PTV Dmax and lungs Dmean were insensitive to small positioning deviations between the VMAT isocenters (1.1% ± 2.4% and 1.2% ± 1.0%, respectively). The average match-line dose measurement indicated patient setup was reproducible (96.1% ± 4.5% relative to prescription dose). Treatment time, including patient setup and beam-on, was 47.5 ± 9.5 min. CONCLUSIONS: The Stanford VMAT-TBI technique, from simulation to treatment delivery, was presented and compared with other VMAT-TBI techniques. Together with publicly shared autoplanning scripts, our technique may provide the gateway for wider adaptation of this technology and the possibility of multi-institutional studies in the cooperative group setting.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Irradiación Corporal Total/métodos
SELECCIÓN DE REFERENCIAS