Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Vet Ophthalmol ; 27(2): 191-196, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38413366

RESUMEN

OBJECTIVE: The objective of the study was to describe the optical coherence tomographic features of a cat with acute corneal hydrops. ANIMAL STUDIED: A 4-year-old castrated male domestic shorthaired showing conjunctival redness, ocular discharge, and intermittent squinting of both eyes with asymmetrical disease onset. METHODS: Complete ophthalmic examination and optical coherence tomography were performed. RESULTS: On slit-lamp biomicroscopic examination, severe intrastromal fluid pockets with profound bullae were observed in the dorsomedial region in both eyes. A diagnosis of feline acute corneal hydrops was made in both eyes. Optical coherence tomography revealed profound stromal lamellar separation representing heterogeneous reflective areas, and fluid pockets and bullae of variable size were concomitant to Descemet's membrane detachment demonstrated by a well-defined homogeneous hyporeflective area. Upon reevaluation 30 days during healing process for both eyes, the thickened epithelia and the thinning pan-stromal areas were identified as homogeneously hyper-reflective epithelia and as heterogeneous hyper-reflectivity, respectively. A thickened posterior corneal surface was shown as heterogeneous with patchy hyper-reflectivity. Additionally, Descemet's membrane detachment in the initial presentation had two distinct forms suspicious of Descemet's membrane rupture in each eye: a break with rolled ends and a break with flat ends. CONCLUSION: To the author's knowledge, this study represents the first documentation of in vivo detection of Descemet's membrane detachment and presumed rupture in a cat experiencing acute corneal hydrops. These observations strongly indicate that Descemet's membrane detachment/rupture acts as a most likely risk factor in the onset of acute corneal hydrops in cats.


Asunto(s)
Enfermedades de los Gatos , Edema Corneal , Gatos , Masculino , Animales , Lámina Limitante Posterior/diagnóstico por imagen , Tomografía de Coherencia Óptica/veterinaria , Tomografía de Coherencia Óptica/métodos , Vesícula/complicaciones , Vesícula/veterinaria , Córnea , Edema Corneal/diagnóstico por imagen , Edema Corneal/veterinaria , Edema/complicaciones , Edema/veterinaria , Enfermedades de los Gatos/diagnóstico por imagen
3.
J Med Case Rep ; 16(1): 351, 2022 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-36183119

RESUMEN

BACKGROUND: We present this report of a new ophthalmic finding in a patient with ochronosis. CASE PRESENTATION: An 85-year-old Caucasian male patient with bilateral dark temporal and nasal pigmentation of conjunctiva and sclera was referred to our hospital owing to low visual acuity. On biomicroscopic examination, bilateral horizontal Descemet's membrane folds were observed. Corneal tomography revealed irregular and asymmetric "against-the-rule" astigmatism in both eyes. Anterior segment optical coherence tomography demonstrated numerous central Descemet's without edema or other corneal structure alterations. CONCLUSION: This is the first report of Descemet's membrane folds in ochronosis. These corneal findings suggest that the accumulation of homogentisic acid in the sclera leads to thickening and stiffness of this region. These alterations could remarkably decrease visual acuity owing to topographic corneal curvature alterations, especially in elderly patients.


Asunto(s)
Lámina Limitante Posterior , Ocronosis , Anciano , Anciano de 80 o más Años , Córnea/diagnóstico por imagen , Lámina Limitante Posterior/diagnóstico por imagen , Ácido Homogentísico , Humanos , Masculino , Ocronosis/complicaciones , Ocronosis/diagnóstico , Agudeza Visual
4.
Cornea ; 41(4): 478-483, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35244628

RESUMEN

PURPOSE: The purpose of this study was to evaluate the effect of Descemet membrane endothelial keratoplasty (DMEK) graft storage time on its elastic properties, measured using atomic force microscopy (AFM). METHODS: Twenty human corneas (from 10 donors), unsuitable for transplantation, were obtained from the eye bank (S. Fyodorov Eye Microsurgery State Institution, Moscow). Ten DMEK grafts were prepared and stored in the corneal storage medium, Optisol-GS at 4°C after preparation, and AFM analysis was performed within 12 hours after preparation (group A). Ten paired corneas from the respective donors were stored in Optisol-GS at 4°C for 1 week after preparation before AFM analysis (group B). Data were analyzed using the Hertz model for the evaluation of the Young modulus of elasticity. RESULTS: Force-distance curve analysis showed an increase in the Young modulus of elasticity in group B in comparison with that in group A, and the mean values were 10.4 ± 1.8 kPa and 6.77 ± 2.25 kPa, respectively (P < 0.001). There was no correlation between the Young modulus of elasticity and donor age (r = 0.110, P = 0.644), endothelial cell count (r = -0.145, P = 0.541), and procurement interval (r = 0.14, P = 0.755). CONCLUSIONS: A longer graft storage time in cold storage medium was found to significantly reduce the elasticity of the DMEK graft. Clinically, this could potentially influence the unfolding of the DMEK graft within the anterior chamber during surgery and the postoperative detachment rate.


Asunto(s)
Lámina Limitante Posterior/fisiología , Queratoplastia Endotelial de la Lámina Limitante Posterior , Elasticidad/fisiología , Endotelio Corneal/citología , Supervivencia de Injerto/fisiología , Preservación de Órganos/métodos , Anciano , Sulfatos de Condroitina/farmacología , Mezclas Complejas/farmacología , Lámina Limitante Posterior/diagnóstico por imagen , Dextranos/farmacología , Femenino , Gentamicinas/farmacología , Humanos , Masculino , Microscopía de Fuerza Atómica , Persona de Mediana Edad , Técnicas de Cultivo de Órganos , Factores de Tiempo , Recolección de Tejidos y Órganos
5.
Zhonghua Yan Ke Za Zhi ; 58(2): 103-111, 2022 Feb 11.
Artículo en Chino | MEDLINE | ID: mdl-35144350

RESUMEN

Objective: To identify and analyze imaging features of posterior polymorphous corneal dystrophy (PPCD) by in vivo confocal microscopy (IVCM). Methods: This retrospective case series enrolled 27 eyes of 18 patients (including 10 males and 8 females) who were diagnosed with PPCD at the Department of Ophthalmology in Peking University Third Hospital between January 2013 and December 2019. The mean age was (23.61±14.81) years. There were 9 monocular and 9 binocular cases. All patients were examined by slit-lamp biomicroscopy and IVCM. The visual acuity, the mean endothelial cell density, and the images of IVCM were analyzed in all cases. Results: The mean best-corrected visual acuity was 0.76±0.33, and the mean endothelial cell density was (1 723.6±698.3) cells/mm2. The IVCM images of type 1 PPCD (vesicular lesions) showed hyperreflective, placoid or homocentric lesions at the level of the Descemet's membrane, hyporeflective, oval or round lesions at the level of the Descemet's membrane, and hyporeflective, crater-like lesions at the level of the endothelial cell layer. The IVCM images of type 2 PPCD (band lesions) displayed hyperreflective, band lesions and a fibrous strand structure at the level of the Descemet's membrane, hyporeflective, vesicular lesions at the level of the Descemet's membrane, and hyporeflective, trough-and ridge-like lesions at the level of the endothelial cell layer. The IVCM images of type 3 PPCD (geographic placoid opacities) showed loss of the hexagonal features of endothelial cells and epithelial-like cell transformation. Conclusions: PPCD primarily affects the endothelium and Descemet's membrane. IVCM could highlight the special characteristics of PPCD including hyperreflective lesions at the level of the Descemet's membrane, hyporeflective lesions at the level of the endothelial cell layer, and epithelial-like cell transformation of endothelial cells. IVCM is an invaluable tool for clinical diagnosis and dynamic monitoring of PPCD.


Asunto(s)
Distrofias Hereditarias de la Córnea , Células Endoteliales , Adolescente , Adulto , Niño , Distrofias Hereditarias de la Córnea/diagnóstico por imagen , Lámina Limitante Posterior/diagnóstico por imagen , Endotelio Corneal/diagnóstico por imagen , Femenino , Humanos , Masculino , Microscopía Confocal , Estudios Retrospectivos , Adulto Joven
7.
Transl Vis Sci Technol ; 10(12): 6, 2021 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-34609477

RESUMEN

Purpose: To evaluate a region of interest (ROI) method of analyzing anterior segment optical coherence tomography (AS-OCT) corneal densitometry (CD) in the setting of Descemet membrane endothelial keratoplasty (DMEK) dehiscence. Methods: Retrospective chart review of eyes that underwent (1) DMEK for Fuchs dystrophy (2) between 2018 to 2020 with (3) a partial DMEK dehiscence on AS-OCT, (4) involvement of only one side of the graft, (5) high-quality corneal AS-OCT scan, and (6) location of dehiscence within the central 5.5 mm of the cornea. Image analysis of the ROIs with ImageJ compared the total edematous area, mean stromal CD, and ratio of anterior-to-posterior (A/P) stromal CD for regions of DMEK dehiscence compared to the contralateral side with an attached DMEK graft. Control regions (with no dehiscence) and postdehiscence resolution images were also analyzed. Results: Seventy sectors of the 21 images from 21 eyes with DMEK dehiscence were included. Compared to the contralateral side, regions of DMEK dehiscence had larger total areas (P < 0.0001), lower mean stromal CD (P = 0.0003), and higher A/P stromal CD (P < 0.0001). All control regions and postdehiscence resolution images did not show any significant differences compared to the contralateral sides. Conclusions: This technique to analyze multiple ROIs on AS-OCT can be useful to evaluate CD of specific regions of corneal pathology. Lower mean stromal CD and higher A/P stromal CD may specify corneal edema. Translational Relevance: Analyzing CD via multiple specific ROIs may be more suitable than measuring the CD of the full cornea and has broader applications extending to other corneal pathologies.


Asunto(s)
Queratoplastia Endotelial de la Lámina Limitante Posterior , Densitometría , Lámina Limitante Posterior/diagnóstico por imagen , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Agudeza Visual
8.
BMJ Case Rep ; 14(8)2021 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-34389595

RESUMEN

We describe a case with complex Descemet membrane detachment (DMD) which persisted despite initial two failed surgical attempts to appose the ocular tissues. However, over time, tissue alignment was obtained spontaneously. A 60-year-old woman, operated trabeculectomy, had a total DMD intraoperatively during a complicated cataract surgery. Initial attempt to DM repositioning with intracameral air injection failed. Anterior Segment Optical Coherence Tomography (ASOCT) showed detachment of both DM and pre-Descemet's layer (PDL). After consultation with a corneal surgeon, patient was again attempted for Intra-operative Optical Coherence Tomography (iOCT)-guided settlement of DMD with intracameral air which again failed. So, the patient was registered for lamellar corneal transplant, but at 3 months follow-up, DM had spontaneously attached, confirmed on ASOCT. This case shows for the first time that even complex DMDs involving PDL, can spontaneously appose despite failed surgical interventions.


Asunto(s)
Enfermedades de la Córnea , Facoemulsificación , Enfermedades de la Córnea/cirugía , Lámina Limitante Posterior/diagnóstico por imagen , Lámina Limitante Posterior/cirugía , Femenino , Humanos , Persona de Mediana Edad , Tomografía de Coherencia Óptica
9.
Sci Rep ; 11(1): 13976, 2021 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-34234179

RESUMEN

Corneal thickness (pachymetry) maps can be used to monitor restoration of corneal endothelial function, for example after Descemet's membrane endothelial keratoplasty (DMEK). Automated delineation of the corneal interfaces in anterior segment optical coherence tomography (AS-OCT) can be challenging for corneas that are irregularly shaped due to pathology, or as a consequence of surgery, leading to incorrect thickness measurements. In this research, deep learning is used to automatically delineate the corneal interfaces and measure corneal thickness with high accuracy in post-DMEK AS-OCT B-scans. Three different deep learning strategies were developed based on 960 B-scans from 50 patients. On an independent test set of 320 B-scans, corneal thickness could be measured with an error of 13.98 to 15.50 µm for the central 9 mm range, which is less than 3% of the average corneal thickness. The accurate thickness measurements were used to construct detailed pachymetry maps. Moreover, follow-up scans could be registered based on anatomical landmarks to obtain differential pachymetry maps. These maps may enable a more comprehensive understanding of the restoration of the endothelial function after DMEK, where thickness often varies throughout different regions of the cornea, and subsequently contribute to a standardized postoperative regime.


Asunto(s)
Paquimetría Corneal , Lámina Limitante Posterior/diagnóstico por imagen , Lámina Limitante Posterior/cirugía , Tomografía de Coherencia Óptica , Paquimetría Corneal/métodos , Queratoplastia Endotelial de la Lámina Limitante Posterior , Humanos
10.
Sci Rep ; 11(1): 14542, 2021 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34267265

RESUMEN

To determine whether measurements of Endothelium/Descemet complex thickness (En/DMT) are of predictive value for corneal graft rejection after high-risk corneal transplantation, we conducted this prospective, single-center, observational case series including sixty eyes (60 patients) at high risk for corneal graft rejection (GR) because of previous immunologic graft failure or having at least two quadrants of stromal vascularization. Patients underwent corneal transplant. At 1st, 3rd, 6th, 9th, and 12th postoperative month, HD-OCT imaging of the cornea was performed, and the corneal status was determined clinically at each visit by a masked cornea specialist. Custom-built segmentation tomography algorithm was used to measure the central En/DMT. Relationships between baseline factors and En/DMT were explored. Time dependent covariate Cox survival regression was used to assess the effect of post-operative En/DMT changes during follow up. A longitudinal repeated measures model was used to assess the relationship between En/DMT and graft status. Outcome measures included graft rejection, central Endothelium/Descemet's complex thickness, and central corneal thickness (CCT). In patients with GR (35%), the central En/DMT increased significantly 5.3 months (95% CI: 2, 11) prior to the clinical diagnosis of GR, while it remained stable in patients without GR. During the 1-year follow up, the rejected grafts have higher mean pre-rejection En/DMTs (p = 0.01), compared to CCTs (p = 0.7). For En/DMT ≥ 18 µm cut-off (at any pre-rejection visit), the Cox proportional hazard ratio was 6.89 (95% CI: 2.03, 23.4; p = 0.002), and it increased to 9.91 (95% CI: 3.32, 29.6; p < 0.001) with a ≥ 19 µm cut-off. In high-risk corneal transplants, the increase in En/DMT allowed predicting rejection prior to the clinical diagnosis.


Asunto(s)
Trasplante de Córnea/efectos adversos , Lámina Limitante Posterior/diagnóstico por imagen , Endotelio Corneal/diagnóstico por imagen , Rechazo de Injerto/diagnóstico , Tomografía/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Niño , Córnea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
14.
Zhonghua Yan Ke Za Zhi ; 57(2): 143-149, 2021 Feb 11.
Artículo en Chino | MEDLINE | ID: mdl-33541057

RESUMEN

Descemet's membrane detachment (DMD) is a complication of intraocular surgery and is more likely to be seen after cataract surgery. As an intraoperative event, DMD usually features wrinkles and edema on the posterior corneal surface or floating membranoid substance seen in the anterior chamber. Such edema is often seen as surgery-caused corneal edema and membranoid substance as the anterior capsule of the lens. Thus, DMD is easily clinically ignored, even though it is conveniently treated if timely observed. Serious consequences are not uncommon with any delayed diagnosis or treatment. Risk factors include advanced age, previous corneal endothelial lesions and glaucoma, as well as preoperative shallow anterior chamber. Clinical diagnosis is based upon intraoperative judgment, corneal edema diagnosed under a microscope or slit lamp and consequent floating Descemet's membrane. In serious cases, anterior segment OCT and UBM are required. Intracameral injections of air are traditionally adopted in the treatment. In less serious cases, patients see self-healing. (Chin J Ophthalmol, 2021, 57: 143-149).


Asunto(s)
Extracción de Catarata , Enfermedades de la Córnea , Edema Corneal , Cámara Anterior , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/cirugía , Edema Corneal/diagnóstico , Lámina Limitante Posterior/diagnóstico por imagen , Lámina Limitante Posterior/cirugía , Humanos
15.
Cornea ; 40(6): 755-763, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33630814

RESUMEN

PURPOSE: To compare the reliability of microkeratome dissection with the anterior chamber pressurizer (ACP) system versus conventional pressurization for ultrathin Descemet-stripping automated endothelial keratoplasty (UT-DSAEK) graft preparation. METHODS: A retrospective review of a consecutive series of dissected donor corneas processed at Pavia Eye Bank for UT-DSAEK surgery was performed. Grafts were prepared through single-pass microkeratome dissection with artificial anterior chamber internal pressure regulation through either ACP or the conventional method using a water column with tube clamp. The target central graft thickness (CGT) was ≤100 µm. Cutting predictability was determined as the difference between the microkeratome head size and the thickness actually removed. Graft regularity was investigated as central-to-peripheral thickness increase, central-to-peripheral (CP) ratio, and graft thickness uniformity. Thickness was measured with anterior segment optical coherence tomography (horizontal and vertical meridians). RESULTS: Of the 265 UT-DSAEK grafts, ACP achieved the target "CGT ≤ 100 µm" in 87 of 120 (72.5%), whereas the conventional technique achieved the same in 85 of 145 (58.6%) (P = 0.018). ACP predictability was -3.9 µm (SD: 2.3), whereas predictability of the conventional technique was -54.6 µm (SD: 3.7) (P < 0.001). Thickness increased similarly (P = 0.212); CP ratio was better with ACP for only 2 mm diameter (P = 0.001); graft thickness uniformity was comparable (P > 0.05). CONCLUSIONS: Compared with conventional pressurization, ACP improved microkeratome-assisted preparation reliability of UT-DSAEK grafts, achieving CGT ≤ 100 µm with significantly higher frequency (P = 0.018) and predictability (P < 0.001). ACP improved CP ratio only at 2 mm (P = 0.001); for other graft thickness, the 2 methods proved equivalent.


Asunto(s)
Cámara Anterior/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Recolección de Tejidos y Órganos/métodos , Anciano , Anciano de 80 o más Años , Lámina Limitante Posterior/diagnóstico por imagen , Endotelio Corneal/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Retrospectivos , Obtención de Tejidos y Órganos , Tomografía de Coherencia Óptica
19.
Br J Ophthalmol ; 105(8): 1082-1086, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32816807

RESUMEN

BACKGROUND/AIMS: To analyse graft detachments prior to rebubbling, the influence of rebubbling on the postoperative outcome after Descemet membrane endothelial keratoplasty (DMEK) and the need for rebubbling on the contralateral eye. METHODS: In this retrospective cohort study, out of 1541 DMEKs, optical coherence tomography scans and clinical records of 499 eyes undergoing rebubbling after DMEK at the University Hospital of Cologne, Cologne, Germany, were examined. Main Outcome measures were (a) number, localisation and size of graft detachments; (b) influence of rebubbling/s on postoperative outcome after 12 months; and (c) rebubbling risk of the contralateral eye after DMEK. RESULTS: Mean number of detachment areas was 2.02±0.9. Mean lateral diameter of all detachments was 4534.76±1920.83 µm. Mean axial diameter was 382.53±282.02 µm. Detachments were equally distributed over all regions of the cornea. Best spectacle corrected visual acuity ( BSCVA) after 12 months was 0.197±0.23 logarithm of the minimum angle of resolution, endothelial cell density (ECD) was 1575.21±397.71 cells/mm2 and mean central corneal thickness (CCT) was 566.37±68.11 µm. BSCVA, CCT, ECD or endothelial cell loss of all rebubbled patients were not influenced by the number of rebubblings or the time between DMEK and rebubbling. Of the rebubbled patients, which received a DMEK subsequently on the other eye, 193 (58.8%) also received a rebubbling, which was significantly higher, when compared to the overall rebubbling rate of 32.3% (p=0.000). CONCLUSIONS: The overall number of rebubblings has no influence on the postoperative outcome after DMEK, if a rebubbling becomes necessary. Patients who received a rebubbling on one eye have an elevated risk for a rebubbling on the fellow eye.


Asunto(s)
Lámina Limitante Posterior/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior , Rechazo de Injerto/cirugía , Complicaciones Posoperatorias , Adulto , Anciano , Anciano de 80 o más Años , Aire , Paquimetría Corneal , Lámina Limitante Posterior/diagnóstico por imagen , Lámina Limitante Posterior/patología , Endotaponamiento , Femenino , Distrofia Endotelial de Fuchs/cirugía , Rechazo de Injerto/diagnóstico por imagen , Rechazo de Injerto/etiología , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Hexafluoruro de Azufre/administración & dosificación , Tomografía de Coherencia Óptica , Agudeza Visual , Adulto Joven
20.
Cornea ; 40(2): 254-257, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32826645

RESUMEN

PURPOSE: To describe a simple finding that can be used to determine donor tissue orientation in Descemet membrane endothelial keratoplasty (DMEK). This involves the appearance of a highly reflective round curved line from an overlapping graft edge within the anterior chamber using light from an endoilluminator. We here name this Kobayashi sign (K-sign). METHODS: Twelve consecutive eyes from 12 patients who underwent DMEK were evaluated for the presence of a K-sign. The presence of Berrospi sign (B-sign), a double-line reflection from the peripheral curls of the Descemet membrane (DM) roll that has been reported to be useful for correct graft orientation, was also evaluated. RESULTS: Of 12 cases, 3 donors showed a loosely scrolled roll soon after DM donor insertion; all 3 of these showed a positive B-sign only when the endoilluminator was used. Nine donors showed a tightly scrolled DM roll without a B-sign; among these 9 donors, a K-sign was visible in 7 cases only when the endoilluminator was used. The remaining 2 cases with a tight scroll configuration showed no K-sign even with the use of endoillumination, indicating that the roll edge was located completely downward; rotation of the roll using a small jet of fluid from paracentesis revealed K-sign in these cases. CONCLUSIONS: This technique is useful for determining the correct orientation of a tightly scrolled DM roll, subsequently enabling rapid DMEK surgery. For loosely scrolled DM roll, endoillumination enhanced B-sing is proven useful.


Asunto(s)
Lámina Limitante Posterior/anatomía & histología , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Técnicas de Diagnóstico Oftalmológico , Luz , Orientación Espacial , Anciano , Lámina Limitante Posterior/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Donantes de Tejidos , Tomografía de Coherencia Óptica , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA