Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.618
Filtrar
1.
J Med Life ; 17(1): 28-34, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38737667

RESUMEN

This study assessed the efficacy of antimicrobial photodynamic therapy (PDT) using a 650 nm diode laser combined with methylene blue (MB) as a photosensitizer to inhibit the growth of Candida albicans (C. albicans). Oral samples were collected from 75 patients diagnosed with oral thrush. C. albicans was isolated and identified using traditional methods and the VITEK 2 YST system. Samples (n = 25) were divided into five groups: Group 1 (control, n = 5) consisted of C. albicans suspensions in saline; Group 2 (n = 5) treated with nystatin; Group 3 (n = 5) exposed to a 650 nm diode laser in continuous mode at 200 mW for 300 seconds; Group 4 (n = 5) treated with 650 nm laser and MB as a photosensitizer; Group 5 (n = 5) exposed to the laser in combination with nystatin. Statistical analysis using ANOVA, Dunnett's t-test (P = 0.05), and LSD (P = 0.001) revealed significant differences in C. albicans counts pre- and post-treatment. Group 5 showed the most significant reduction in C. albicans, followed by Group 4, while Groups 2 and 3 showed the least variation. The findings suggest that PDT using a 650 nm diode laser with methylene blue (in continuous mode at 200 mW for 300 seconds) effectively reduced the prevalence of C. albicans.


Asunto(s)
Candida albicans , Azul de Metileno , Fotoquimioterapia , Fármacos Fotosensibilizantes , Candida albicans/efectos de los fármacos , Fotoquimioterapia/métodos , Humanos , Azul de Metileno/farmacología , Fármacos Fotosensibilizantes/farmacología , Láseres de Semiconductores/uso terapéutico , Candidiasis Bucal/tratamiento farmacológico , Candidiasis Bucal/microbiología , Nistatina/farmacología , Antifúngicos/farmacología , Antifúngicos/uso terapéutico
2.
Sci Rep ; 14(1): 11457, 2024 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769365

RESUMEN

To compare two different wavelengths of the surgical contact diode laser (CDL) for producing a posterior laryngofissure in in-vivo pigs. Anesthetized pigs underwent a tracheostomy and an anterior laryngofissure through a cervicotomy. They were randomly selected for the CDL wavelength and Power, according to the peak of Power set at device (980nm wavelength: Ppeak power of 10 W, 15 W, and 20 W, or 1470 nm wavelength: Ppeak 3 W, 5 W, 7 W, 10 W). At the end of the experiment, the laryngotracheal specimen was extracted and sent for histology and morphometry measurements (incision size, depth, area, and lateral thermal damage). Hemodynamic data and arterial blood gases were recorded during the incisions. Statistical analysis of the comparisons between the parameters and groups had a level of significance of p < 0.05. Twenty-six pigs were divided into CDL 980 nm (n = 11) and 1470 nm (n = 15). There was a greater incision area at the thyroid level in the 980 nm CDL and a wider incision at the trachea level, with a larger distance between mucosa borders. There were no significant differences in the area of lateral thermal damage between the two groups and neither difference among the power levels tested. Both wavelengths tested showed similar results in the various combinations of power levels without significant differences in the lateral thermal damage. The posterior laryngofissure incision can be performed by either of the wavelengths at low and medium power levels without great difference on lateral thermal damage.


Asunto(s)
Laringe , Láseres de Semiconductores , Animales , Porcinos , Laringe/cirugía , Terapia por Láser/métodos , Tráquea/cirugía
3.
Pan Afr Med J ; 47: 105, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38766568

RESUMEN

Denture-induced fibrous hyperplasia (DIFH) is a persistent lesion caused by low-intensity chronic injury of the tissue in contact with an ill-fitting, over-extended denture. This fibrous connective tissue lesion commonly occurs in oral mucosa in patients showing important alveolar ridge atrophy. Surgical excision is the treatment of choice for DIFH. This article describes a successful laser surgery to remove a DIFH on a lower alveolar ridge of a patient wearing an ill-fitting completely removable denture. The use of a diode laser may result in less surgical time, less bleeding during surgery, more vestibular depth, better re-epithelialization of the wound, and no need for suturing.


Asunto(s)
Hiperplasia , Láseres de Semiconductores , Humanos , Láseres de Semiconductores/uso terapéutico , Hiperplasia/cirugía , Femenino , Mucosa Bucal/patología , Terapia por Láser/métodos , Terapia por Láser/efectos adversos , Fibrosis , Dentadura Completa , Persona de Mediana Edad
4.
Sci Total Environ ; 931: 172793, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38688380

RESUMEN

Pollen, a significant natural bioaerosol and allergen for sensitized individuals, is expected to increase in prevalence due to climate change. Mitigating allergy symptoms involves avoiding pollen exposure and pre-medication, emphasizing the importance of real-time knowledge of localized ambient air pollen concentrations. Laser diode Optical Particle Counters (OPCs) are commonly used for monitoring particle number concentrations in ambient air. This study explores the hypothesis that OPCs can monitor pollen but may struggle to distinguish them from other particles. We aimed to isolate the pollen signal from collective particle number concentrations using source apportionment models, specifically Positive Matrix Factorization (PMF) and Unmix, applied to multiple bin OPC data. The pollen signals isolated using PMF show slightly better correlation values than those isolated using Unmix. PMF-derived pollen signals exhibit strong correlations with Holoptelea (r = 0.64) and total pollen (r = 0.54) concentrations, while a moderate correlation is observed with Poaceae (r = 0.47). Exclusion of low pollen events strengthens correlations for Holoptelea and Poaceae to very strong (r = 0.87) and strong (r = 0.67), respectively. Although both model types effectively isolate the pollen signal, metrics suggest that Unmix has the potential for more accurate predictions of both moderate and extreme pollen events simultaneously. The Mean Absolute Error (MAE), Root Mean Square Error (RMSE), and Relative Root Mean Square Error (RRMSE) metrics for Holoptelea are 46.2 grains m-3, 72.4 grains m-3, and 15.3; for Poaceae, 3.9 grains m-3, 4.9 grains m-3, and 13.0; and for total pollen, 43.5 grains m-3, 72.1 grains m-3, and 14.1. This study represents a significant development in the use of source apportionment models and ambient OPCs for real-time pollen monitoring, offering a cost-effective alternative to conventional automated pollen sensors. Despite challenges, the proposed methodology provides a practical and accessible solution for pollen monitoring, contributing to the advancement of bioaerosol monitoring technologies.


Asunto(s)
Aerosoles , Contaminantes Atmosféricos , Monitoreo del Ambiente , Polen , Aerosoles/análisis , Monitoreo del Ambiente/métodos , Contaminantes Atmosféricos/análisis , Alérgenos/análisis , Láseres de Semiconductores
5.
J Cosmet Dermatol ; 23 Suppl 1: 19-26, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38587300

RESUMEN

BACKGROUND: The use of non-ablative fractionated lasers for skin rejuvenation has been proven to be effective in improving skin texture, and has become popular due to minimal wounding, significantly shorter recovery times and decreased adverse effects. OBJECTIVE: To retrospectively analyze improvement in skin texture in healthy women aged over 18 years with Fitzpatrick skin types II-IV. METHODS: Participants received three facial and/or neck treatments with the 1570-nm fractional scanning diode laser at 1-month intervals. Three months after the last treatment session two blinded evaluators assessed skin improvement using before and after photos. Pain and patient satisfaction were recorded. RESULTS: Sixteen women with a mean age of 45.4 ± 4.1 years (range 35-50 years) and skin type II-IV were included in the analysis. All 16 participants received facial treatments and seven (43.8%) also received neck treatments. Three months follow-up evaluation showed that the majority of participants had a visible change in the treated areas. Mean pain score was low and decreased with each treatment session. CONCLUSION: Skin treatment using fractional scanning 1570-nm diode laser improves skin laxity in women with skin types II-IV. Larger studies are warranted to further clarify the efficacy and safety of this modality.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Envejecimiento de la Piel , Humanos , Femenino , Adulto , Persona de Mediana Edad , Rejuvenecimiento , Láseres de Semiconductores/efectos adversos , Estudios Retrospectivos , Cara , Láseres de Estado Sólido/efectos adversos , Satisfacción del Paciente , Dolor/etiología , Resultado del Tratamiento , Terapia por Láser/efectos adversos
7.
Braz Oral Res ; 38: e025, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38597545

RESUMEN

Treatment of oral vascular anomalies (OVA) has focused on minimally invasive techniques rather than radical surgery. We investigated the efficacy and safety of diode laser using the photocoagulation technique in the management of OVA. Forty-seven subjects with OVA were treated with forced dehydration with induced photocoagulation (FDIP) using diode laser (808 nm/4.5 W). This series consisted mostly of male (63.8%) and non-white (63.8%) patients with a mean age of 57.4 years. Varices (91.5%), venous malformations (6.4%), and hemangiomas (2.1%) with a mean size of 7.1 (±4.9) mm were the conditions treated. OVA presented as a nodular lesion (63.8%) involving mainly the lower lip (46.8%). Pulsed laser mode was used as standard and the number of applications varied from one to four sessions, with the majority requiring only one (83%) FDIP session. Kaplan-Meier analysis revealed that complete clinical healing can occur on the 15th day (n=9/29.5%), followed by the 20th (n=6/45.5%), and 30th (n=7/70.5%) days. Postoperative edema was observed in 31 (66%) patients, and recurrence of the lesion occurred in two (4.2%). Based on the data on complete clinical healing, minimal patient discomfort, and satisfactory esthetic results, we can confirm that FDIP by diode laser is a promising candidate for the safe and efficacious treatment of OVA.


Asunto(s)
Láseres de Semiconductores , Labio , Humanos , Masculino , Persona de Mediana Edad , Láseres de Semiconductores/uso terapéutico , Labio/cirugía , Labio/irrigación sanguínea , Resultado del Tratamiento , Cicatrización de Heridas
8.
PLoS One ; 19(4): e0301630, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38603689

RESUMEN

Aiming at the weak performance of chaotic light output in semiconductor laser systems, the study designed a power control algorithm for semiconductor laser drive systems based on linear self-disturbance rejection control. Then the optimization parameters and scope were determined, and multi-objective optimization and direction preference algorithms were introduced. A chaotic optical performance optimization model based on improved multi-objective genetic algorithm was constructed using adaptive functions as evaluation indicators. These results confirmed that the larger the bandwidth of the controller, the faster the response speed of the resonant converter, but the stability was poor. When the input voltage underwent a sudden change, the current ripple coefficient of the PID algorithm was 0.55%. The linear active disturbance rejection control algorithm could ensure that the voltage and current maintained at the set values, and the output current of the algorithm was more stable when the load underwent sudden changes. The directional preference algorithm could further provide more valuable solutions on the basis of adaptive genetic algorithms. When the peak value of the autocorrelation function was equal to 0.2, the delay characteristics of chaotic light were effectively suppressed, having strong signal bandwidth and complexity. In summary, the constructed model has good application effects in optimizing chaotic optical performance and has certain positive significance for communication security.


Asunto(s)
Algoritmos , Láseres de Semiconductores , Comunicación , Tiempo de Reacción , Semiconductores
9.
Photobiomodul Photomed Laser Surg ; 42(4): 285-293, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38662503

RESUMEN

Objective: This study aims to explore the preventive potential of photobiomodulation (PBM) in bisphosphonate-related osteonecrosis of the jaw (BRONJ) using a rat model. Methods: An experimental rat model was established, exposing rats to zoledronic acid (ZA), a primary risk factor for BRONJ. An 810 nm diode laser was applied with parameters of 0.33 W/cm2 power density and 10 J/cm2 energy density for 30 sec. PBM was initiated 1 day pre-extraction and continued for 2 weeks. The impact of PBM on wound healing in both soft and hard tissues was evaluated post tooth extraction. Results: ZA exposure hindered wound healing in both soft and hard tissues after tooth extraction. PBM intervention effectively mitigated the adverse effects of ZA, promoting healing processes in both tissue types. This suggests the potential of PBM as a preventive strategy for BRONJ in patients on long-term bisphosphonate treatment. Moreover, PBM exhibited enhanced wound healing in normal rats, indicating its broader applicability beyond BRONJ cases. Conclusions: PBM shows promise in preventing and improving wound healing in BRONJ and normal cases. These findings underscore the significance of optimizing PBM parameters and suggest its potential clinical relevance as a preventive intervention for BRONJ and a promoter of wound healing.


Asunto(s)
Osteonecrosis de los Maxilares Asociada a Difosfonatos , Modelos Animales de Enfermedad , Terapia por Luz de Baja Intensidad , Ratas Sprague-Dawley , Extracción Dental , Cicatrización de Heridas , Ácido Zoledrónico , Animales , Osteonecrosis de los Maxilares Asociada a Difosfonatos/prevención & control , Osteonecrosis de los Maxilares Asociada a Difosfonatos/etiología , Ratas , Ácido Zoledrónico/farmacología , Cicatrización de Heridas/efectos de los fármacos , Cicatrización de Heridas/efectos de la radiación , Conservadores de la Densidad Ósea , Difosfonatos/farmacología , Láseres de Semiconductores/uso terapéutico , Imidazoles/farmacología , Masculino
10.
J Appl Oral Sci ; 32: e20230419, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38655987

RESUMEN

OBJECTIVE: This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. METHODOLOGY: The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. RESULTS: The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. CONCLUSION: The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.


Asunto(s)
Láseres de Semiconductores , Láseres de Estado Sólido , Márgenes de Escisión , Lengua , Animales , Láseres de Semiconductores/uso terapéutico , Láseres de Estado Sólido/uso terapéutico , Lengua/cirugía , Lengua/patología , Reproducibilidad de los Resultados , Ovinos , Tejido Conectivo/patología , Epitelio/patología , Valores de Referencia , Procedimientos Quirúrgicos Orales/métodos , Mucosa Bucal/patología , Mucosa Bucal/cirugía , Estadísticas no Paramétricas , Terapia por Láser/métodos , Terapia por Láser/instrumentación
11.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656028

RESUMEN

PURPOSE: The purpose of this study is to assess the long-term outcomes of modified transcanalicular diode laser dacryocystorhinostomy in a large cohort of patients affected by primary acquired nasolacrimal duct obstruction. METHODS: This study, conducted from January 17 to June 2022, encompassed 141 patients (159 procedures) who underwent modified transcanalicular diode laser dacryocystorhinostomy (MT-DCR). The procedure employed an 810-nm diode laser. Patients were monitored for at least a year after the intervention. Anatomical success was determined by ostium patency upon irrigation, while functional success referred to epiphora resolution. Parameters studied included patient demographics, procedure duration, complications, and both anatomical and functional success. Statistical analysis was performed using the Statistical Package for the Social Sciences software, with results considered significant at a 95% confidence interval (p≤0.05). RESULTS: A total of 159 lacrimal drainage systems (141 patients: 112 women and 29 men) were included in this study. Among them, 18 underwent bilateral procedures. The average patient age was 58 years (range: 34-91 years), and the average surgical duration was 24 minutes (range: 18-35 minutes). One year after the surgery, MT-DCR exhibited anatomical and functional success rates of 84.9% (135/159) and 83% (132/159), respectively. CONCLUSION: MT-DCR achieved an anatomical success rate of 84.9%, reflecting an excellent outcome. However, further extensive studies with larger sample sizes and longer follow-up periods are necessary to substantiate these findings.


Asunto(s)
Dacriocistorrinostomía , Obstrucción del Conducto Lagrimal , Láseres de Semiconductores , Humanos , Dacriocistorrinostomía/métodos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Resultado del Tratamiento , Láseres de Semiconductores/uso terapéutico , Anciano de 80 o más Años , Factores de Tiempo , Conducto Nasolagrimal/cirugía , Tempo Operativo , Estudios Retrospectivos
12.
J Indian Prosthodont Soc ; 24(2): 136-143, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38650338

RESUMEN

AIM: To evaluate and compare the effect of impregnated retraction cord vs Laser on gingival attachment level and pain perception following retraction for subgingival margins. SETTINGS AND DESIGN: Many methods for achieving and measuring the amount of gingival retraction in fixed prosthodontic work have been advocated. Though the gingival attachment level is crucial in Periodontology, the literature available regarding the effect of these retraction methods on the same is scarce. Hence, this clinical study was designed to compare the pain perception and amount of gingival recession when impregnated cord and laser were used for retraction. MATERIALS AND METHODS: In 40 subjects (age range of 20 to 40 years) with single missing maxillary incisor, the abutments were prepared with subgingival margins, to receive a full coverage metal-ceramic fixed dental prosthesis. The gingiva was retracted on one of the abutments with impregnated retraction cord and on the other with diode laser. Gingival attachment levels were compared at six sites per abutment using superimposition of digital scans, preoperative and four weeks after cementation of final prosthesis. STATISTICAL ANALYSIS USED: Statistical analysis of the data for gingival recession was done using t-test. Pain perception was analysed with Chi-square test. Pain perception by patients following retraction was compared with VAS scale. RESULTS: The average values of gingival recession on buccal side were 0.61 mm and 0.38 mm and on the palatal side were 0.58 mm and 0.35 mm for impregnated retraction cord and laser respectively. The P values of <0.01 indicated a highly significant difference between the two groups. Intragroup comparison did not show significant differences between various sites. Pain and discomfort produced by cord method was moderate in comparison with mild/no pain with diode laser and the difference was highly significant.Conclusion: Retraction cord produced more gingival recession than the diode laser, which was statistically highly significant on both buccal and palatal aspects of the teeth. Patients experience with diode laser technique was less painful in comparison with retraction cord method.


Asunto(s)
Recesión Gingival , Percepción del Dolor , Humanos , Adulto , Estudios Prospectivos , Femenino , Masculino , Percepción del Dolor/fisiología , Adulto Joven , Técnicas de Retracción Gingival/instrumentación , Encía , Láseres de Semiconductores/uso terapéutico , Dimensión del Dolor/métodos
13.
Sci Rep ; 14(1): 9137, 2024 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-38644422

RESUMEN

To investigate the therapeutic potential of photodynamic therapy (PDT) for malignant gliomas arising in unresectable sites, we investigated the effect of tumor tissue damage by interstitial PDT (i-PDT) using talaporfin sodium (TPS) in a mouse glioma model in which C6 glioma cells were implanted subcutaneously. A kinetic study of TPS demonstrated that a dose of 10 mg/kg and 90 min after administration was appropriate dose and timing for i-PDT. Performing i-PDT using a small-diameter plastic optical fiber demonstrated that an irradiation energy density of 100 J/cm2 or higher was required to achieve therapeutic effects over the entire tumor tissue. The tissue damage induced apoptosis in the area close to the light source, whereas vascular effects, such as fibrin thrombus formation occurred in the area slightly distant from the light source. Furthermore, when irradiating at the same energy density, irradiation at a lower power density for a longer period of time was more effective than irradiation at a higher power density for a shorter time. When performing i-PDT, it is important to consider the rate of delivery of the irradiation light into the tumor tissue and to set irradiation conditions that achieve an optimal balance between cytotoxic and vascular effects.


Asunto(s)
Glioma , Láseres de Semiconductores , Fotoquimioterapia , Fármacos Fotosensibilizantes , Porfirinas , Animales , Fotoquimioterapia/métodos , Glioma/tratamiento farmacológico , Glioma/patología , Porfirinas/farmacología , Porfirinas/uso terapéutico , Ratones , Láseres de Semiconductores/uso terapéutico , Línea Celular Tumoral , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Modelos Animales de Enfermedad , Aloinjertos , Apoptosis/efectos de los fármacos , Masculino
14.
Otol Neurotol ; 45(5): 489-494, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38530360

RESUMEN

BACKGROUND: Microdrill and diode laser are two different methods used in endoscopic stapedotomy for otosclerosis. These two methods have not been compared in endoscopic stapedotomy. AIMS/OBJECTIVES: To analyze the differences between microdrill and diode laser in endoscopic stapedotomy for otosclerosis. MATERIALS AND METHODS: This is a randomized clinical trial; patients with otosclerosis were randomly divided into microdrill group (group A: n = 69) and diode laser group (group B: n = 62). Differences between the two groups were then compared. RESULTS: The preoperative air-bone gap (ABG) was 25.40 ± 10.88 dBHL in group A and 24.84 ± 12.23 dBHL in group B, with no significant between-group difference ( p > 0.05). The postoperative ABG in group A was 13.27 ± 9.91 dBHL versus 11.79 ± 10.82 dBHL in group B, and there was no significant difference between the groups ( p > 0.05). The surgical time in group B (64 ± 31.23 minutes) was significantly longer than that in group A (48 ± 25.62 minutes) ( p = 0.02). There were no significant between-group differences in basic patient-related data, preoperative air conduction (AC), preoperative bone conduction (BC), postoperative AC, distribution of postoperative ABG, preoperative ABG at different frequencies, and postoperative ABG at different frequencies. There was also no significant between-group difference in the average bleeding volume or number of patients with postoperative dizziness. CONCLUSION AND SIGNIFICANCE: The postoperative improvement in hearing level in the two group was equivalent, but group A had the advantage of a shorter operation time. LEVEL OF EVIDENCE: 4.


Asunto(s)
Conducción Ósea , Endoscopía , Láseres de Semiconductores , Otosclerosis , Cirugía del Estribo , Humanos , Cirugía del Estribo/métodos , Otosclerosis/cirugía , Femenino , Masculino , Adulto , Persona de Mediana Edad , Láseres de Semiconductores/uso terapéutico , Endoscopía/métodos , Resultado del Tratamiento , Terapia por Láser/métodos , Tempo Operativo
15.
Sensors (Basel) ; 24(6)2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38544236

RESUMEN

Caffeine is the most widely consumed stimulant and is the subject of significant ongoing research and discussions due to its impact on human health. The industry's need to comply with country-specific food and beverage regulations underscores the importance of monitoring caffeine levels in commercial products. In this study, we propose an alternative technique for caffeine analysis that relies on mid-infrared laser-based photothermal spectroscopy (PTS). PTS exploits the high-power output of the quantum cascade laser (QCL) sources to enhance the sensitivity of the mid-IR measurement. The laser-induced thermal gradient in the sample scales with the analytes' absorption coefficient and concentration, thus allowing for both qualitative and quantitative assessment. We evaluated the performance of our experimental PTS spectrometer, incorporating a tunable QCL and a Mach-Zehnder interferometer, for detecting caffeine in coffee, black tea, and an energy drink. We calibrated the setup with caffeine standards (0.1-2.5 mg mL-1) and we benchmarked the setup's capabilities against gas chromatography (GC) and Fourier-transform infrared (FTIR) spectroscopy. Quantitative results aligned with GC analysis, and limits of detection matched the research-grade FTIR spectrometer, indicating an excellent performance of our custom-made instrument. This method offers an alternative to established techniques, providing a platform for fast, sensitive, and non-destructive analysis without consumables as well as with high potential for miniaturization.


Asunto(s)
Bebidas , Cafeína , Humanos , Cafeína/análisis , Espectrofotometría Infrarroja , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Bebidas/análisis , Láseres de Semiconductores
17.
Sci Rep ; 14(1): 6871, 2024 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-38519552

RESUMEN

Previous findings indicated that the laser photobiomodulation is more effective than the control or placebo in preserving the alveolar socket. This study aimed to compare two different lasers regarding their effectiveness in aiding alveolar socket preservation. Twenty extraction sockets were selected then divided into two equal groups. Group A was exposed to 650 nm Diode laser, and Group B to 810 nm Diode laser following the same protocol and parameters after a standard alveolar socket preservation procedure with collagen plug. Radiographic analysis with cone beam computed tomography was done to compare the alveolar bone surface area immediately after extraction and three months post-operatively, while bone samples collected before implant drilling were histologically examined for newly formed bone evaluation and histomorphometric analysis in terms of percentage of new bone surface area, percentage of unmineralized bone and finally, immunohistochemical analysis of Osteocalcin reaction surface area as well as optical density. Radiographically, infrared (810 nm) Diode effect on alveolar bone surface area has significantly exceeded the red laser, while histologically, red (650 nm) Diode has demonstrated statistical significance regarding all parameters; newly formed bone surface area percentage, unmineralized bone area percentage and finally Osteocalcin bone marker reaction surface area percentage and optical density. Under the specified conditions and laser parameters, photobiomodulation using the 810 nm Diode got the upper hand radiographically, yet histologically, the red 650 nm Diode managed to dominate all histological parameters when both employed as an adjunct to alveolar socket preservation procedures.


Asunto(s)
Pérdida de Hueso Alveolar , Terapia por Luz de Baja Intensidad , Humanos , Proceso Alveolar/diagnóstico por imagen , Proceso Alveolar/cirugía , Proceso Alveolar/patología , Alveolo Dental/diagnóstico por imagen , Alveolo Dental/cirugía , Alveolo Dental/patología , Láseres de Semiconductores/uso terapéutico , Osteocalcina , Extracción Dental/métodos , Pérdida de Hueso Alveolar/patología
19.
Photobiomodul Photomed Laser Surg ; 42(4): 306-313, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38546858

RESUMEN

Background: This investigation set out to compare the impacts of low-level diode laser (LLDL) and red light-emitting diode (LED) on the survival of human dental pulp stem cells (hDPSCs) and osteogenic/odontogenic differentiation. Methods and materials: In this ex vivo experimental study, the experimental groups underwent the irradiation of LLDL (4 J/cm2 energy density) and red LED in the osteogenic medium. Survival of hDPSCs was assessed after 24 and 48 h (n = 9) using the methyl thiazolyl tetrazolium (MTT) assay. The assessment of osteogenic/odontogenic differentiation was conducted using alizarin red staining (ARS; three repetitions). The investigation of osteogenic and odontogenic gene expression was performed at two time points, specifically 24 and 48 h (n = 12). This analysis was performed utilizing real-time reverse-transcription polymerase chain reaction (RT-PCR). The groups were compared at each time point using SPSS version 24. To analyze the data, the Mann-Whitney U test, analysis of variance, Tukey's test, and t-test were utilized. Results: The MTT assay showed that LLDL significantly decreased the survival of hDPSCs after 48 h, compared with other groups (p < 0.05). The qualitative results of ARS revealed that LLDL and red LED increased the osteogenic differentiation of hDPSCs. LLDL and red LED both upregulated the expression of osteogenic/odontogenic genes, including bone sialoprotein (BSP), alkaline phosphatase (ALP), dentin matrix protein 1 (DMP1), and dentin sialophosphoprotein (DSPP), in hDPSCs. The LLDL group exhibited a higher level of gene upregulation (p < 0.0001). Conclusions: The cell survival of hDPSCs was reduced, despite an increase in osteogenic/odontogenic activity. Clinical relevance: Introduction of noninvasive methods in regenerative endodontic treatments.


Asunto(s)
Diferenciación Celular , Supervivencia Celular , Pulpa Dental , Láseres de Semiconductores , Terapia por Luz de Baja Intensidad , Odontogénesis , Osteogénesis , Células Madre , Humanos , Pulpa Dental/citología , Pulpa Dental/efectos de la radiación , Diferenciación Celular/efectos de la radiación , Osteogénesis/efectos de la radiación , Células Madre/efectos de la radiación , Células Madre/citología , Supervivencia Celular/efectos de la radiación , Odontogénesis/efectos de la radiación , Células Cultivadas , Luz Roja
20.
Am J Dent ; 37(1): 39-46, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38458982

RESUMEN

PURPOSE: To investigate the differences between irrigant propagation and temperature changes using laser-activated irrigation (LAI) at different settings in an artificial root canal model. METHODS: Using an artificial resin root canal model, irrigant activation was achieved in 19 experimental groups with eight samples each. A 9,300 nm CO2 laser, two diode lasers with different settings (wavelengths 455, 808, 970, and 980 nm) were compared to 2,940 nm Er:YAG laser and traditional needle irrigation. Er:YAG and CO2 laser were activated in the pulpal chamber only, while diode lasers and needles were inserted into the main root canal. Lasers were activated for 5x 20 seconds resulting in 100 seconds of activation or rinsing for each sample. After each activation of 20 seconds, a photo was taken of the side canals and the propagation of the dye was measured with a digital measuring tool after calibration. Further, the temperature of the irrigant was reported after activation of 20 seconds and repeated 5 times. Data were checked for normality and statistically compared. RESULTS: All lasers increased the irrigant propagation compared to conventional irrigation. Significant differences were found between groups regarding propagation and temperature (P< 0.0027). Er:YAG and CO2 laser had similar effects on irrigant propagation in middle and apical located side-canals with specific power parameters and were superior to diode lasers and syringe irrigation. The irrigant's temperature increased significantly with the diode and CO2 lasers. CLINICAL SIGNIFICANCE: Diode lasers and CO2 lasers have not been established for irrigant activation. 9,300 nm CO2 lasers absorb well in water and were shown to introduce vapor bubble formation and streaming in water. Diode lasers are highly accepted in periodontics. The laser light is not absorbed in water but interacts with bacteria as well as soft tissues and contributes therefore to infection control. With a modified laser tip it was however possible to introduce cavitation and streaming in irrigants.


Asunto(s)
Dióxido de Carbono , Láseres de Estado Sólido , Láseres de Semiconductores , Prueba de Estudio Conceptual , Irrigantes del Conducto Radicular , Cavidad Pulpar/microbiología , Agua , Preparación del Conducto Radicular/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA