Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.458
Filtrar
1.
Int Ophthalmol ; 44(1): 327, 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-38997613

RESUMEN

PURPOSE: To report the long term visual outcomes and complications with use of the novel CM-T Flex scleral fixated intraocular lens (CMT-SFIOL). MATERIALS AND METHODS: 116 eyes that underwent CMT-SFIOL were reviewed and 57 eyes with CMT-SFIOL that completed a 2-year follow-up were included. Main outcome measures noted were best-corrected visual acuity (BCVA) and complications. Postoperatively, follow-ups were done at 1 week (1w), 1 month (1 m), 1 year (1y) and 2-year (2y) intervals. RESULTS: 40 (70.17%) of 57 eyes received CMT-SFIOL for surgical aphakia. Mean follow up was 39.77 ± 8.44 months. BCVA for distance & near improved from 1.26 ± 0.84 to 0.76 ± 0.77, 0.50 ± 0.72 and 0.51 ± 0.73 & 1.28 ± 0.58 to 0.98 ± 0.49, 0.92 ± 0.44 and 0.89 ± 0.40 at 1 m, 1y and 2y respectively (p < 0.001 for all). At 1w, 10 eyes (17.54%) had corneal edema (CE) and 8 eyes (14.03%) had anterior chamber (AC) reaction. Two eyes (3.50%) had IOP > 30 mm Hg and 1 eye (1.75%) had vitreous hemorrhage (VH). At 1 m, 3 eyes (5.26%) had CE and 5 eyes (8.77%) had AC reaction. Two eyes (3.50%) had IOP > 30 mm Hg and 1 eye (1.75%) had VH. Cystoid macular edema was noted in 3 eyes (5.26%). At 1y and 2y, 2 eyes (3.5%) and 1 eye (1.75%), had CE. No decentration, dislocation, haptic exposure or retinal detachment was noted. No eyes required resurgery. CONCLUSION: CM-T Flex SFIOL is an effective method to correct aphakia, with reliable and safe long-term results.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Diseño de Prótesis , Esclerótica , Agudeza Visual , Humanos , Femenino , Masculino , Esclerótica/cirugía , Lentes Intraoculares/efectos adversos , Persona de Mediana Edad , Estudios de Seguimiento , Estudios Retrospectivos , Anciano , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Adulto , Complicaciones Posoperatorias/epidemiología , Anciano de 80 o más Años , Factores de Tiempo , Resultado del Tratamiento , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología
2.
BMC Ophthalmol ; 24(1): 300, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39039537

RESUMEN

BACKGROUND: The aim of this study was to analyze the causes and characteristics of IOL explantation within the first year after primary implantation. METHODS: In this retrospective, cross sectional database study, a database consisting of over 2500 IOL explants sent from 199 national and international doctors over the past 10 years was analyzed. All IOLs explanted within the first year after implantation were included in this analysis. Explants with insufficient information as well as phakic and Add-on IOLs were excluded. Main outcome measures were the reason for explantation, the time between implantation and explantation, as well as IOLs' and patients' characteristics. Additionally, the explanted IOLs were microscopically and histologically analyzed, as required. RESULTS: Of all explanted IOLs from the database, 1.9% (n = 50) were explanted within the first year after implantation. The most frequent reasons for early IOL explantation were IOL dislocation (32%), visual intolerance (26%), opacification (20%), and intraoperative complications (16%). The time between implantation and explantation was the shortest in cases with intraoperative complications (1.5 ± 3.1 days), followed by IOL dislocation (90.9 ± 103.9 days), visual intolerance (98.3 ± 86.5 days), opacifications (253.5 ± 124.0 days) and other indications (249.7 ± 124.0 days). Calcification of hydrophilic IOLs was the main type of opacification (80%). Notably, seven IOLs required immediate intraoperative exchange due to an intraoperative crack in the optic or a torn off haptic. CONCLUSION: Indications for early IOL explantation were IOL dislocation, visual intolerance, opacification, and intraoperative complications. Especially intraoperative damages to the IOL and early calcification show a potential for improvement of affected IOLs and implantation systems.


Asunto(s)
Bases de Datos Factuales , Remoción de Dispositivos , Lentes Intraoculares , Humanos , Estudios Retrospectivos , Estudios Transversales , Femenino , Masculino , Lentes Intraoculares/efectos adversos , Persona de Mediana Edad , Anciano , Complicaciones Posoperatorias/epidemiología , Implantación de Lentes Intraoculares , Factores de Tiempo , Adulto , Falla de Prótesis , Complicaciones Intraoperatorias/epidemiología , Agudeza Visual , Anciano de 80 o más Años
3.
Retina ; 44(8): 1337-1343, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39047127

RESUMEN

BACKGROUND: Retrospective cohort study of 561 adult patients undergoing secondary intraocular lens (IOL) implantation by vitreoretinal surgeons at a single institution from April 2015 to December 2020. METHODS: Patient historical factors, intraoperative/postoperative complications, and outcomes of IOL type (anterior chamber IOL versus scleral sutured IOL versus scleral fixated IOL versus. sulcus) were assessed. Primary outcomes were rates of postoperative retinal tears and rhegmatogenous retinal detachment. Secondary outcomes were rates of intraoperative endolaser, intraoperative retinal tear, and further IOL surgery. RESULTS: The incidence of intraoperative retinal tears was 7.3% and not significantly different between techniques. Rates of intraoperative endolaser use were 17.5% among all techniques and not significantly different between techniques. Rates of postoperative retinal tear were low (0%-2.7%). Rates of postoperative rhegmatogenous retinal detachment were not significantly different between techniques (anterior chamber IOL 9/198 [4.5%], SFIOL 1/54 [1.9%], scleral sutured IOL 14/274 [5.1%], sulcus 2/35 [5.7%], total 26/561 [4.6%], P = 0.79). Rates of repeat IOL surgery trended higher in sulcus lenses (anterior chamber IOL 5/198 [2.5%], SFIOL 4/54 [7.4%], scleral sutured IOL 16/274 [5.8%], sulcus 5/35 [14.3%], total 30/561 [5.3%], P = 0.12). CONCLUSION: Intraoperative endolaser use and intraoperative retinal tear are not uncommon in secondary IOL surgery and underscore the importance of careful vitreoretinal management among these patients.


Asunto(s)
Implantación de Lentes Intraoculares , Complicaciones Posoperatorias , Desprendimiento de Retina , Agudeza Visual , Vitrectomía , Humanos , Vitrectomía/métodos , Vitrectomía/efectos adversos , Estudios Retrospectivos , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Femenino , Masculino , Anciano , Desprendimiento de Retina/cirugía , Complicaciones Posoperatorias/epidemiología , Persona de Mediana Edad , Perforaciones de la Retina/cirugía , Estudios de Seguimiento , Complicaciones Intraoperatorias , Incidencia , Reoperación , Lentes Intraoculares/efectos adversos
4.
Vestn Oftalmol ; 140(3): 27-33, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38962976

RESUMEN

Congenital subluxation of the lens as a complication of Marfan syndrome, Weill-Marchesani syndrome, microspherophakia, etc. leads to the development of amblyopia and requires timely surgical treatment with removal of the subluxated lens and implantation of an artificial intraocular lens (IOL). IOL implantation in children with pathology of the ligamentous apparatus of the lens remains an urgent problem of ophthalmic surgery due to the lack of a consensus regarding the IOL fixation method among practitioners. PURPOSE: This study evaluated the effectiveness and safety of IOL implantation with transscleral fixation using the knotless Z-suture technique in pediatric patients with congenital lens subluxation. MATERIAL AND METHODS: The study included 24 children (36 eyes) with grade III congenital subluxation of the lens who underwent phacoaspiration of the subluxated lens with IOL implantation with transscleral fixation using the knotless Z-suture performed in the Kazakh Research Institute of Eye Diseases in Almaty in the period from 2017 to 2021. The average observation period was 31.7±11.3 months (2.0 to 4.5 years). The stability of the IOL position, the state of the intrascleral sutures, visual acuity after surgery, the presence and severity of complications in the long-term period were evaluated. RESULTS: All patients (100%) had a significant improvement in visual acuity after surgery. No intraoperative complications were registered in any of the cases. Postoperative complications were noted in 8.3% of cases (n=3). The final functional outcome of surgical treatment depended on the presence of concomitant pathology, the main cause of low vision was the development of refractive amblyopia due to refractive errors. CONCLUSIONS: The presented technique of transscleral fixation of IOL has proven to be reliable, which is especially important for pediatric patients considering their high physical activity and expected lifespan.


Asunto(s)
Implantación de Lentes Intraoculares , Subluxación del Cristalino , Lentes Intraoculares , Esclerótica , Agudeza Visual , Humanos , Masculino , Femenino , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/etiología , Subluxación del Cristalino/diagnóstico , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Preescolar , Lentes Intraoculares/efectos adversos , Esclerótica/cirugía , Técnicas de Sutura , Resultado del Tratamiento , Niño , Complicaciones Posoperatorias/etiología
5.
Cesk Slov Oftalmol ; 80(3): 170-174, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38886109

RESUMEN

The aim of the thesis is to present the case of a patient in whom bilateral calcification of the hydrophilic intraocular lens (IOL) Lentis M+ LS-313 MF30 (Oculentis) has developed. Due to the negative effect on visual functions, explantation and replacement of the artificial lens was necessary in both eyes. Case Report: An overview of the available literature summarized the diagnostics, current examination methods and possibilities of the surgical solution of calcification of the bifocal hydrophilic lens Lentis M+ LS-313 MF30 (Oculentis). The specific solution is described in a case report of a patient in whom calcification of both lenses developed 6 years after implantation of the IOL. In 2015, the patient underwent uncomplicated cataract surgery of both eyes with the implantation of an artificial intraocular lens into the capsule. In September 2021, an 82-year-old man was examined at our outpatient clinic for deterioration of visual acuity and changes in the material of the artificial IOL which were perceptible during a clinical examination, on the recommendation of a local ophthalmologist. Blurred vision predominated. A diagnosis of intraocular lens opacification was confirmed and documented using a Scheimpflug camera (OCULUS Pentacam HR) and anterior OCT (Avanti RTVue XR Optovue,). The patient was indicated for explantation and replacement of the opacified intraocular lens in the left and subsequently in the right eye- The same type of IOL was used for reimplantation with good functional results. Conclusion: Since 2010, multifocal lens implantation has been on an upward trend worldwide. This type of MF IOL has also been used in thousands of implantations. A number of other explantations can be expected in the coming years. The optimal solution is the correct replacement of the calcified IOL with the same construction made of safer hydrophobic material.


Asunto(s)
Melanoma , Radiocirugia , Humanos , Masculino , Radiocirugia/efectos adversos , Melanoma/radioterapia , Anciano de 80 o más Años , Calcinosis/cirugía , Calcinosis/diagnóstico por imagen , Neoplasias de la Coroides/radioterapia , Neoplasias de la Coroides/diagnóstico , Lentes Intraoculares/efectos adversos , Traumatismos por Radiación/etiología , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/cirugía , Neoplasias de la Úvea/radioterapia , Implantación de Lentes Intraoculares/efectos adversos
6.
Acta Med Okayama ; 78(3): 295-300, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38902219

RESUMEN

A Japanese woman in her 70s was referred to our hospital for the evaluation and treatment of high intraocular pressure (IOP) in her right eye. She had undergone bilateral cataract surgeries and the insertion of hydrophilic acrylic intraocular lenses (IOLs). We performed trabeculotomy and trabeculectomy to lower her right IOP; thereafter, a circular opacity was observed on the right eye's IOL surface. We removed the right IOL because that eye's vision had decreased due to IOL opacification. The analysis of the removed IOL revealed that the main opacity component was calcium phosphate. This is the first post-glaucoma-surgery IOL calcification case report.


Asunto(s)
Calcinosis , Glaucoma , Lentes Intraoculares , Humanos , Femenino , Lentes Intraoculares/efectos adversos , Calcinosis/etiología , Anciano , Glaucoma/cirugía , Glaucoma/etiología , Implantación de Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/etiología
7.
Int Ophthalmol ; 44(1): 240, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38904711

RESUMEN

PURPOSE: To clarify the characteristics of intraocular lens (IOL) dislocation requiring IOL suture or intraocular scleral fixation. METHODS: This retrospective consecutive case series included 21 eyes (21 patients) who required sutured or sutureless intrascleral IOL fixation following IOL extraction owing to IOL dislocation at the outpatient clinic in the Department of Ophthalmology, Saitama Red Cross Hospital, Japan, between January and December 2019. Medical records were retrospectively reviewed for background diseases, location of the dislocated IOL (intracapsular/extracapsular), insertion of a capsular tension ring (CTR), and the period from IOL insertion to dislocation. RESULTS: We included 21 eyes of 21 patients who required IOL suture or intrascleral fixation for IOL dislocation at our clinic from January to December 2019 were included. The most common background disease was pseudoexfoliation syndrome (four cases), followed by atopic dermatitis, dysplasia/dehiscence of the zonule, post-retinal detachment surgery, high myopia, and uveitis (three cases each). At the time of dislocation, the IOLs were either intracapsular (16 cases, including 3 cases with CTR insertion) or extracapsular (5 cases). The time from IOL insertion to IOL dislocation was 13.7 ± 8.1 years (maximum: 31.3 years, minimum: 1.7 years). CONCLUSIONS: In this study, all 21 cases represented late IOL dislocations occurring after 3 months postoperatively. Among these late IOL dislocation cases, IOL dislocation occurred in a short-medium period of time, especially in those with CTR insertion and weakness/dehiscence of the zonule, with an average of 3 to 5 years postoperatively. We propose referring to these cases as intermediate-term IOL dislocation.


Asunto(s)
Migracion de Implante de Lente Artificial , Lentes Intraoculares , Humanos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Migracion de Implante de Lente Artificial/cirugía , Migracion de Implante de Lente Artificial/etiología , Migracion de Implante de Lente Artificial/diagnóstico , Lentes Intraoculares/efectos adversos , Anciano de 80 o más Años , Factores de Tiempo , Agudeza Visual , Adulto , Esclerótica/cirugía , Técnicas de Sutura , Estudios de Seguimiento , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias
9.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656707

RESUMEN

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Asunto(s)
Segmento Anterior del Ojo , Facoemulsificación , Tomografía de Coherencia Óptica , Humanos , Facoemulsificación/efectos adversos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Anciano , Segmento Anterior del Ojo/diagnóstico por imagen , Lentes Intraoculares/efectos adversos , Persona de Mediana Edad , Agudeza Visual , Anciano de 80 o más Años , Migracion de Implante de Lente Artificial/diagnóstico , Migracion de Implante de Lente Artificial/etiología , Implantación de Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Cristalino/diagnóstico por imagen , Estudios Prospectivos
10.
J Fr Ophtalmol ; 47(6): 104186, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38663226

RESUMEN

PURPOSE: To compare two swept-source OCT optical biometers, the Anterion® (Heidelberg Engineering GmbH, Heidelberg, Germany) and the IOLMaster 700® (Carl Zeiss Meditec AG, Jena, Germany), in the analysis of biometric data, intraocular lens (IOL) calculation and postoperative spherical equivalent predictability. METHODS: This was a real-life, single-center, retrospective study including 152 eyes of 81 consecutive patients referred for cataract surgery. All patients were examined with the IOLMaster 700® and the Anterion®. Biometric data (axial length [AL], anterior chamber depth [ACD], mean keratometry [Km], K1 [flat keratometry], K2 [steep keratometry] and axis, TK1 [flat total keratometry], TK2 [steep total keratometry], central pachymetry, lens thickness [LT], white-to-white distance [WTW]), IOL calculation with the SRK/T formula, and postoperative refractive outcome at 1 month were compared. RESULTS: All biometric measurements were significantly different between the two biometers. Correlations were excellent for AL, pachymetry, ACD, LT and keratometry measurements, and for the IOL calculation (r>0.96, intraclass correlation coefficient=1). The IOL power for emmetropia was similar between both biometers when the SRK/T formula was used (20.84±3.24D versus 20.86±3.29D, P=0.61). The mean postoperative spherical equivalent prediction error calculated using the SRK/T formula was 0.03±0.5D for the IOLMaster 700® versus 0.01±0.47D for the Anterion® (P=0.12). CONCLUSIONS: This study showed excellent correlation and agreement for the biometric measurements and the IOL power calculation with the SRK/T formula between both biometers.


Asunto(s)
Biometría , Extracción de Catarata , Lentes Intraoculares , Refracción Ocular , Tomografía de Coherencia Óptica , Humanos , Biometría/instrumentación , Biometría/métodos , Estudios Retrospectivos , Masculino , Femenino , Tomografía de Coherencia Óptica/métodos , Anciano , Persona de Mediana Edad , Refracción Ocular/fisiología , Lentes Intraoculares/efectos adversos , Anciano de 80 o más Años , Resultado del Tratamiento , Implantación de Lentes Intraoculares/métodos
11.
Int Ophthalmol ; 44(1): 151, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38507136

RESUMEN

PURPOSE: To identify the rate and characteristics of cataract surgery candidates suitable for multifocal intraocular lens implantation among patients undergoing preoperative evaluation in a public hospital. MATERIALS AND METHODS: Screening was performed based on the patient's medical records, comprehensive ophthalmic examination, optical biometry (Zeiss, IOL Master 700) and optical coherence tomography (OCT) (Heidelberg, OCT Spectralis) in accordance with the relevant indications and contraindications mentioned in the pertinent literature. Patients were included in the present study if they were eligible for bilateral cataract surgery. The exclusion criteria were the presence of central nervous system or motility issues, prior refractive surgery, the presence of astigmatism greater than 1 dioptre and/or the presence of important ocular comorbidities in either eye. RESULTS: The study evaluated 1200 consecutive patients. Four hundred thirty-two patients (36%) were not eligible for bilateral surgery and were excluded from the study. Of the 768 patients included in the present study, 346 (45.1%) were considered suitable candidates. Four hundred twenty-two patients (54.9%) were excluded for one or both eyes. Among them, 121 (28.7%) were excluded because of retinal disease, 120 (28.4%) because of regular astigmatism (> 1.0 D of corneal astigmatism), 32 (7.5%) because of pseudoexfoliation or zonular instability, and 30 (7.1%) because of glaucoma or ocular hypertension; in addition, 90 (21.3%) patients were excluded for multiple reasons. Suitable candidates were significantly younger (70 and 75 years, respectively) (p < 0.001). After being informed about the potential risks and benefits of MOIL implantation, 212 of 346 (83.8%) eligible patients provided consent. CONCLUSION: Close to half of cataract patients in a public hospital were eligible for MOIL implantation, and the majority of patients would proceed to surgery. The most prevalent contraindication was macular disease.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares/efectos adversos , Agudeza Visual , Facoemulsificación/métodos , Catarata/complicaciones , Catarata/epidemiología , Refracción Ocular
12.
Int Ophthalmol ; 44(1): 152, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38509438

RESUMEN

PURPOSE: To evaluate and compare the clinical outcomes of three different methods of intraocular lens (IOL) implantation in the surgery of subluxated cataracts. METHODS: In this retrospective, comparative, clinical interventional study, the medical records of patients who underwent IOL implantation with sutureless 27-gauge needle-assisted transconjunctival intrascleral (Group 1), Z-suture knotless transscleral (Group 2), and Cionni capsular tension ring (Cionni-CTR) assisted (Group 3) simultaneously with subluxated cataract extraction between June 2010 and June 2022 were evaluated. Demographic characteristics, follow-up times, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical and cylindrical refractive values, and spherical equivalent (SE) values of three groups were compared. Intraoperative and postoperative complications were recorded. RESULTS: There were 20 eyes in Group 1, 35 eyes in Group 2, and 40 eyes in Group 3. In all groups, statistically significant improvement was observed in postoperative UDVA and CDVA compared to preoperative values (each p < 0.05). There was no statistical difference between the groups in postoperative UDVA and CDVA values. (p = 0.130, p = 0.167 respectively). No significant difference was observed between the groups in terms of postoperative spherical, cylindrical, and SE values (each p > 0.05). CONCLUSION: The study suggests that three different IOL implantation techniques for simultaneous IOL implantation in subluxated cataract surgery have similar effects on visual and refractive outcomes.


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Extracción de Catarata/efectos adversos , Catarata/complicaciones , Suturas/efectos adversos
13.
JAMA Ophthalmol ; 142(3): e234841, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38512158

RESUMEN

This case report describes a diagnosis of dystrophic calcification of a silicone intraocular lens implant in a patient who presented with foggy vision and glare.


Asunto(s)
Calcinosis , Coristoma , Lentes Intraoculares , Humanos , Lentes Intraoculares/efectos adversos , Calcinosis/diagnóstico por imagen , Calcinosis/etiología
14.
BMC Ophthalmol ; 24(1): 141, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38549070

RESUMEN

PURPOSE: In the present study, we aimed to evaluate the efficacy of the bandage contact lens (BCLs) in the treatment of dry eye disease (DED) after complicated cataract or/and intraocular lens (IOL) surgery. METHODS: In this retrospective, single-centered, observational study, we collected data from 69 patients who underwent complicated cataract or/and IOL surgery. Of these, 35 cases wore their own BCLs immediately after the operation, while the other 34 cases did not have their own BCLs and were instead covered with gauze. The Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp microscope examination, keratograph analysis, and Schirmer I test were measured at baseline, 1 week and 1 month postoperatively. RESULTS: In the BCL group, the score of the OSDI questionnaire was significantly decreased at 1 week and 1 month postoperatively compared with baseline levels (P = 0.000, collectively). Moreover, the fluorescein staining score of the BCL group was remarkably decreased 1-week and 1-month postoperatively compared with the non-BCL group (P = 0.000 and P = 0.000, respectively). Furthermore, the redness score of the BCL group was also better compared with the non-BCL group at 1 week and 1 month postoperatively (P = 0.014 and P = 0.004, respectively). CONCLUSIONS: Complicated cataract or/and IOL surgery would intensify the DED. Early application of BCLs postoperatively improved patients' comfort and alleviated dry eye-related symptoms and signs. Furthermore, this mechanism might involve the acceleration of corneal epithelial healing, the alleviation of ocular stress response and the stabilization of the tear film. TRIAL REGISTRATION: Trial registration ClinicalTrials, NCT04120389. Registered 10 October 2019-retrospectively registered.


Asunto(s)
Catarata , Lentes de Contacto Hidrofílicos , Síndromes de Ojo Seco , Lentes Intraoculares , Humanos , Estudios Retrospectivos , Lentes Intraoculares/efectos adversos , Catarata/complicaciones , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/diagnóstico , Lentes de Contacto Hidrofílicos/efectos adversos , Vendajes/efectos adversos
15.
J Fr Ophtalmol ; 47(4): 104105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38428321

RESUMEN

PURPOSE: To compare the visual outcomes in both eyes of patients who undergo phacoemulsification and trifocal intraocular lens (IOL) implantation and have asteroid hyalosis (AH) or synchysis scintillans (SS) in only one eye. METHODS: A retrospective comparative case series was performed. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction after implantation of the same model of trifocal IOL in both eyes (PhysIOL FineVision Pod-F and Micro-F and Rayner RayOne Trifocal). RESULTS: A total of 164 eyes of 82 patients (41 females, 50%) met the inclusion criteria. There were no statistically significant differences in sphere, cylinder, spherical equivalent, UDVA, UIVA, or UNVA between the groups. Postoperative CDVA was slightly better in the control group (logMAR 0.03) than in the AH/SS group (logMAR 0.04) (P: 0.014). There were no statistically significant differences in predictability, safety index, or efficacy index between the groups. Overall subjective satisfaction was good (98.2%). CONCLUSIONS: Visual outcomes and satisfaction are good after implantation of trifocal IOLs in eyes with AH or SS. Therefore, trifocal IOLs should not be ruled out in these patients when no other vitreoretinal disorder is present.


Asunto(s)
Lentes Intraoculares , Enfermedades Orbitales , Facoemulsificación , Femenino , Humanos , Facoemulsificación/efectos adversos , Implantación de Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Satisfacción del Paciente , Lentes Intraoculares/efectos adversos , Refracción Ocular , Trastornos de la Visión , Diseño de Prótesis , Seudofaquia/complicaciones , Seudofaquia/cirugía
17.
J Refract Surg ; 40(2): e98-e107, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38346118

RESUMEN

PURPOSE: To determine the prevalence of opacification of a hydrophylic intraocular lens (IOL) with hydrophobic coverage and the percentage of explantations required, determining possible risk factors associated with these opacifications. METHODS: This ambispective study enrolled 575 eyes of 296 patients (age 36 to 87 years) that underwent cataract surgery between 2010 and 2017 with implantation of different models of Lentis Mplus IOLs: LS-312-MF30, LS-313-MF15, LS-313-MF30, LU-313-MF30, and LU-313-MF30T (Oculentis GmbH). Visual, refractive, and slit-lamp biomicroscopic changes were evaluated in a long-term follow-up. The percentage of cases with IOL opacification and the percentage of cases in which IOL explantation was required due to such opacifications were calculated at each visit. Five of the explanted IOLs from this series could be analyzed by scanning electron microscopy (SEM-EDX). RESULTS: IOL opacification developed in 63 eyes (11.0%). With 95% confidence, the prevalence of IOL opacification was between 842 and 1,401 cases per 10,000 eyes. The time elapsed between surgery and the presence of IOL opacification ranged between 0 and 9.3 years (mean: 4.7 ± 2.2 years). No significant differences in terms of IOL opacification rate were found according to gender (P = .378). No significant differences were found in arterial hypertension, diabetes, hypothyroidism, or hyperthyroidism rates between eyes with or without IOL opacification (P ≥ .053). IOL explantation was needed in 9 eyes (1.57%). SEM-EDX analysis confirmed the presence of rough areas on the IOL surface containing different components, such as calcium, phosphorous, copper, or nitrogen. CONCLUSIONS: The prevalence of opacification with time in Lentis Mplus IOLs is high, with no systemic risk factors associated with this complication, suggesting that it may be attributable to the material and/or the manufacturing process. [J Refract Surg. 2024;40(2):e98-e107.].


Asunto(s)
Lentes Intraoculares , Lentes Intraoculares Multifocales , Facoemulsificación , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Implantación de Lentes Intraoculares/efectos adversos , Prevalencia , Refracción Ocular , Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/epidemiología
18.
Sci Rep ; 14(1): 3368, 2024 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336847

RESUMEN

In this study, we described and discussed the late onset spontaneous posterior capsule rupture with intraocular lens (IOL) dislocation years after uncomplicated cataract surgery and implantation of hydrophobic acrylic IOLs. Eight patients presented with spontaneous posterior capsule rupture and IOL dislocation 5-20 years after uncomplicated phacoemulsification and IOL (AcrySof, Alcon, US) implantation. None of the patients had undergone posterior capsulotomy in the past. Four of the patients admitted habitual eye rubbing. An intact and well-centered continuous curvilinear capsulotomy edge was observed in all cases. IOLs were dislocated or displaced behind the anterior capsulotomy with a significant decrease in vision. A large rupture with a curled edge of the broken posterior capsule was visible. Dislocated IOLs were removed, and a three-piece IOL was inserted in the sulcus in six cases and suture fixated to the sclera in two cases. Improved vision was achieved in all cases. Although the mechanism underlying this late complication is unclear, habitual eye rubbing or IOL design may play a role. Further investigation is needed to prevent this complication in the future.


Asunto(s)
Extracción de Catarata , Catarata , Subluxación del Cristalino , Lentes Intraoculares , Facoemulsificación , Humanos , Lentes Intraoculares/efectos adversos , Implantación de Lentes Intraoculares/efectos adversos , Extracción de Catarata/efectos adversos , Facoemulsificación/efectos adversos , Subluxación del Cristalino/complicaciones , Complicaciones Posoperatorias , Diseño de Prótesis , Catarata/etiología
19.
J Fr Ophtalmol ; 47(3): 104095, 2024 Mar.
Artículo en Francés | MEDLINE | ID: mdl-38382417

RESUMEN

Thermal shock can cause intraoperative opacification of a Carlevale (Soleko®) implant. This is a rare phenomenon which resolves spontaneously. It is crucial to recognise this phenomenon in order to avoid unnecessary and potentially harmful explantation decisions for the patient.


Asunto(s)
Ojo Artificial , Lentes Intraoculares , Humanos , Lentes Intraoculares/efectos adversos , Remoción de Dispositivos , Esclerótica/cirugía
20.
BMC Ophthalmol ; 24(1): 77, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38378504

RESUMEN

PURPOSE: To report the refractive outcomes of long (≥25.00 mm) and short (≤22.00 mm) axial length (AL) eyes undergoing immediately sequential bilateral cataract surgery (ISBCS). METHODS: In this retrospective cohort study, patients who underwent ISBCS were identified and eyes of patients with bilateral long and short ALs were included. Pre- and postoperative biometry, autorefraction, and ocular comorbidities or complications were recorded. The primary outcome was the mean refractive prediction error. RESULTS: Thirty-seven patients (74 eyes) with long ALs and 18 patients (36 eyes) with short ALs were included. The means ± standard deviations of the ALs were 26.40 ± 1.38 mm and 21.44 ± 0.46 mm in the long and short AL groups, respectively. In long AL eyes, the mean absolute error from the biometry-predicted refraction was - 0.16 ± 0.46 D, corresponding to 74% of eyes achieving a refraction within ±0.50 D of the predicted value. In short AL eyes, the mean absolute error was - 0.63 ± 0.73 D, corresponding to 44% of eyes achieving a refraction within ±0.50 D of the predicted value. Eight (44.4%) patients with short AL eyes had a myopic deviation greater than ±0.50 D from the predicted result in both eyes. CONCLUSIONS: Compared to patients with long AL eyes, ISBCS in patients with short ALs had a wider variance in refractive outcome and a lower rate of achieving a postoperative refraction within ±0.50 D of the predicted target.


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares , Errores de Refracción , Humanos , Agudeza Visual , Implantación de Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Lentes Intraoculares/efectos adversos , Refracción Ocular , Errores de Refracción/etiología , Biometría , Longitud Axial del Ojo , Catarata/complicaciones , Extracción de Catarata/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA