Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29.304
Filtrar
2.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
3.
Card Electrophysiol Clin ; 16(2): 139-142, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749632

RESUMEN

This case report discusses a 42-year-old male with dextro-transposition of the great arteries (D-TGA) status post Mustard repair and sick sinus syndrome status post dual-chamber pacemaker implant, who developed symptomatic superior vena cava (SVC) baffle stenosis. He was treated with a combined pacemaker extraction and subsequent SVC baffle stenting. The case highlights the complexities of treating SVC baffle stenosis in the presence of cardiac implantable devices and demonstrates the efficacy of this combined approach. Furthermore, the authors delve into the intricacies of D-TGA, its surgical history, and the long-term complications associated with atrial switch procedures.


Asunto(s)
Remoción de Dispositivos , Marcapaso Artificial , Stents , Transposición de los Grandes Vasos , Humanos , Transposición de los Grandes Vasos/cirugía , Masculino , Adulto , Marcapaso Artificial/efectos adversos , Síndrome de la Vena Cava Superior/cirugía , Síndrome de la Vena Cava Superior/etiología , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/cirugía
4.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749633

RESUMEN

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Remoción de Dispositivos/métodos , Desfibriladores Implantables/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Marcapaso Artificial/efectos adversos , Masculino , Ecocardiografía Transesofágica , Tomografía Computarizada por Rayos X , Anciano , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/diagnóstico por imagen , Femenino , Persona de Mediana Edad
5.
Card Electrophysiol Clin ; 16(2): 117-124, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749629

RESUMEN

Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).


Asunto(s)
Remoción de Dispositivos , Terapia por Láser , Vena Cava Superior , Humanos , Vena Cava Superior/lesiones , Vena Cava Superior/cirugía , Femenino , Remoción de Dispositivos/efectos adversos , Masculino , Terapia por Láser/efectos adversos , Persona de Mediana Edad , Anciano , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos
6.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749635

RESUMEN

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Asunto(s)
Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Marcapaso Artificial/efectos adversos , Masculino , Anciano , Bloqueo Cardíaco/terapia , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Femenino
7.
Card Electrophysiol Clin ; 16(2): 133-138, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749631

RESUMEN

Persistent left superior vena cava (PLSVC) is an anatomic variant that is relatively uncommon in the general population. Lead extraction through PLSVC is extremely rare. Due to unusual anatomy, the procedure carries challenges that require special considerations and careful planning. The authors report a case of lead extraction through a PLSVC with occluded right superior vena cava and highlight the challenges and outcomes of the procedure.


Asunto(s)
Remoción de Dispositivos , Síndrome de la Vena Cava Superior , Vena Cava Superior , Humanos , Vena Cava Superior/anomalías , Vena Cava Superior/cirugía , Vena Cava Superior/diagnóstico por imagen , Síndrome de la Vena Cava Superior/cirugía , Síndrome de la Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior Izquierda Persistente/cirugía , Vena Cava Superior Izquierda Persistente/diagnóstico por imagen , Masculino , Desfibriladores Implantables , Marcapaso Artificial , Femenino
8.
Card Electrophysiol Clin ; 16(2): 149-155, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749634

RESUMEN

Leadless pacemaker systems (LPs) were developed as an alternative to traditional transvenous permanent pacemakers (TV-PPM) due to increasing rates of device and procedural related complications, leading to a high-cost burden to our health-care system. LPs were initially indicated for single-chamber ventricular pacing; however, recent developments have allowed for dual-chamber pacing too. These systems have demonstrated highly successful implant rates with stable pacing performance. This article describes the retrieval techniques of the Micra LPs and ways to mitigate challenges encountered during the retrieval process.


Asunto(s)
Remoción de Dispositivos , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/métodos
9.
J Med Case Rep ; 18(1): 238, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38705996

RESUMEN

BACKGROUND: Takotsubo cardiomyopathy is a novel form of rapidly reversible heart failure occurring secondary to a stressor that mimics an acute coronary event. The underlying etiology of the stressor is highly variable and can include medical procedures. Pacemaker insertion is an infrequent cause of Takotsubo cardiomyopathy. CASE PRESENTATION: An 86-year-old Caucasian woman underwent an uncomplicated pacemaker insertion for symptomatic complete heart block in the background of slow atrial fibrillation. A transient episode of polymorphic ventricular tachycardia was noted on day 1 following the procedure; however, her pacemaker was checked and, as she remained stable, she was discharged home. She presented again 5 days later with symptomatic heart failure. Chest X-ray confirmed pulmonary edema. Echocardiography confirmed new onset severe left ventricle dysfunction. Pacemaker checks were normal and lead placement was confirmed. Though her troponin I was elevated, her coronary angiogram was normal. Contrast enhanced echocardiography suggested apical ballooning favoring Takotsubo cardiomyopathy. She was treated for heart failure and made a good recovery. Her follow-up echocardiography a month later showed significant improvement in left ventricle function. CONCLUSIONS: Takotsubo cardiomyopathy is mediated by a neuro-cardiogenic mechanism due to hypothalamic-pituitary-adrenal axis activation. It generally has a good prognosis. Complications though uncommon, can occur and include arrhythmias. Pacemaker insertion as a precipitant stressor is an infrequent cause of Takotsubo cardiomyopathy. As pacemaker insertions are more frequent in the elderly age group, this phenomenon should be recognized as a potential complication.


Asunto(s)
Marcapaso Artificial , Taquicardia Ventricular , Cardiomiopatía de Takotsubo , Humanos , Cardiomiopatía de Takotsubo/terapia , Cardiomiopatía de Takotsubo/complicaciones , Cardiomiopatía de Takotsubo/etiología , Femenino , Anciano de 80 o más Años , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Ecocardiografía , Electrocardiografía , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones
10.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38716936

RESUMEN

OBJECTIVE: The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices. METHODS: A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement. RESULTS: The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death. CONCLUSION: No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.


Asunto(s)
Desfibriladores Implantables , Hematoma , Marcapaso Artificial , Humanos , Femenino , Masculino , Desfibriladores Implantables/efectos adversos , Factores de Riesgo , Anciano , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Hematoma/etiología , Hematoma/mortalidad , Infecciones Relacionadas con Prótesis/mortalidad , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Factores de Tiempo , Anciano de 80 o más Años
11.
Sci Rep ; 14(1): 10440, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714750

RESUMEN

A wide variety of treatments have been developed to improve respiratory function and quality of life in patients with bilateral vocal fold paresis (BVFP). One experimental method is the electrical activation of the posterior cricoarytenoid (PCA) muscle with a laryngeal pacemaker (LP) to open the vocal folds. We used an ovine (sheep) model of unilateral VFP to study the long-term effects of functional electrical stimulation on the PCA muscles. The left recurrent laryngeal nerve was cryo-damaged in all animals and an LP was implanted except for the controls. After a reinnervation phase of six months, animals were pooled into groups that received either no treatment, implantation of an LP only, or implantation of an LP and six months of stimulation with different duty cycles. Automated image analysis of fluorescently stained PCA cross-sections was performed to assess relevant muscle characteristics. We observed a fast-to-slow fibre type shift in response to nerve damage and stimulation, but no complete conversion to a slow-twitch-muscle. Fibre size, proportion of hybrid fibres, and intramuscular collagen content were not substantially altered by the stimulation. These results demonstrate that 30 Hz burst stimulation with duty cycles of 40% and 70% did not induce PCA atrophy or fibrosis. Thus, long-term stimulation with an LP is a promising approach for treating BVFP in humans without compromising muscle conditions.


Asunto(s)
Modelos Animales de Enfermedad , Terapia por Estimulación Eléctrica , Músculos Laríngeos , Parálisis de los Pliegues Vocales , Animales , Ovinos , Parálisis de los Pliegues Vocales/terapia , Parálisis de los Pliegues Vocales/fisiopatología , Terapia por Estimulación Eléctrica/métodos , Músculos Laríngeos/fisiopatología , Humanos , Marcapaso Artificial/efectos adversos , Pliegues Vocales/fisiopatología , Pliegues Vocales/patología , Femenino
12.
Med Sci Monit ; 30: e944114, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38776271

RESUMEN

BACKGROUND Long-term right ventricular (RV) pacing has been linked to left atrial enlargement (LAE). The incidence and risk factors associated with significant LAE after RV pacing remain unknown. This retrospective study included 461 patients requiring RV pacing at 2 centers between 2012 and 2020 and aimed to evaluate the incidence, risk factors, outcomes, and complications of LAE. MATERIAL AND METHODS A total of 461 patients with normal-sized pre-implant left atrial dimension and dual-chamber pacing pacemaker implantation for complete atrioventricular block were enrolled. Patients were grouped based on a ≥20% increase from their baseline left atrial dimension by echocardiography, indicating significant LAE, and initial characteristics, echocardiographic data, and outcomes were compared. RESULTS During a mean 7.0±4.9 years follow-up period, 96 patients (20.8%) developed significant LAE, whereas 365 patients did not. In multivariate logistic regression analysis, smaller pre-implant left atrial dimension (OR, 0.776; 95% CI, 0.728-0.828; P<0.001), lower post-implant left ventricular ejection fraction (OR, 0.976; 95% CI, 0.957-0.995; P=0.014), post-implant development of moderate to severe mitral regurgitation (OR, 2.357; 95% CI, 1.172-4.740; P=0.016), and RV pacing duration ≥3.3 years (OR, 1.576; 95% CI, 1.039-2.646; P=0.045) were independent predictors of significant LAE after RV-dependent pacing. There was a significant difference in the incident stroke events between patients without and with significant LAE (9.9% vs 17.7%; log-rank P=0.047). CONCLUSIONS Long-term RV pacing was linked to significant LAE in 20.8% of patients with complete atrioventricular block, with those affected experiencing a higher stroke rate during follow-up.


Asunto(s)
Estimulación Cardíaca Artificial , Ecocardiografía , Atrios Cardíacos , Ventrículos Cardíacos , Humanos , Femenino , Masculino , Estudios Retrospectivos , Factores de Riesgo , Incidencia , Anciano , Atrios Cardíacos/fisiopatología , Estimulación Cardíaca Artificial/métodos , Estimulación Cardíaca Artificial/efectos adversos , Persona de Mediana Edad , Ventrículos Cardíacos/fisiopatología , Ecocardiografía/métodos , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Cardiomegalia/fisiopatología , Marcapaso Artificial , Resultado del Tratamiento , Anciano de 80 o más Años
14.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38714107

RESUMEN

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Arritmias Cardíacas , Falla de Equipo
15.
J Cardiothorac Surg ; 19(1): 296, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778360

RESUMEN

BACKGROUND: There is little literature on the use of temporary pacemakers in children with fulminant myocarditis. Therefore, we summarized the use of temporary cardiac pacemakers in children with fulminant myocarditis in our hospital. METHODS: The clinical data of children with fulminant myocarditis treated with temporary pacemakers in Wuhan Children's Hospital from January 2017 to May 2022 were retrospectively analyzed. RESULTS: A total of 6 children were enrolled in the study, including 4 boys and 2 girls, with a median age of 50 months and a median weight of 15 kg. The average time from admission to pacemaker placement was 2.75 ± 0.4 h. The electrocardiogram showed that all 6 children had third-degree atrioventricular block (III°AVB). The initial pacing voltage, the sensory sensitivity of the ventricle and the pacing frequency were set to 5-10 mV, 5 V and 100-120 bpm respectively. The sinus rhythm was recovered in 5 patients within 61 h (17-134) h, and the median time of using temporary pacemaker was 132 h (63-445) h. One of the children had persistent III°AVB after the temporary pacemaker. With parental consent, the child was fitted with a permanent pacemaker on the 12th day of his illness. CONCLUSIONS: When fulminant myocarditis leads to severe bradycardia or atrioventricular block in children, temporary pacemakers have the characteristics of high safety to improve the heart function.


Asunto(s)
Bloqueo Atrioventricular , Miocarditis , Marcapaso Artificial , Humanos , Miocarditis/terapia , Miocarditis/fisiopatología , Masculino , Femenino , Preescolar , Estudios Retrospectivos , Niño , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Lactante , Electrocardiografía , Estimulación Cardíaca Artificial/métodos , Bradicardia/terapia , Bradicardia/fisiopatología , Resultado del Tratamiento
17.
Arq Bras Cardiol ; 121(4): e20230386, 2024 Apr.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-38695408

RESUMEN

BACKGROUND: The use of artificial cardiac pacemakers has grown steadily in line with the aging population. OBJECTIVES: To determine the rates of hospital readmissions and complications after pacemaker implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS). METHODS: A prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%. RESULTS: A total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost. CONCLUSIONS: The results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.


FUNDAMENTO: O uso de marca-passos cardíacos artificiais tem crescido constantemente, acompanhando o envelhecimento populacional. OBJETIVOS: Determinar as taxas de readmissões hospitalares e complicações após implante de marca-passo ou troca de gerador de pulsos e avaliar o impacto desses eventos nos custos anuais do tratamento sob a perspectiva do Sistema Único de Saúde (SUS). MÉTODOS: Registro prospectivo, com dados derivados da prática clínica assistencial, coletados na hospitalização índice e durante os primeiros 12 meses após o procedimento cirúrgico. O custo da hospitalização índice, do procedimento e do seguimento clínico foram estimados de acordo com os valores reembolsados pelo SUS e analisados ao nível do paciente. Modelos lineares generalizados foram utilizados para estudar fatores associados ao custo total anual do tratamento, adotando-se um nível de significância de 5%. RESULTADOS: No total, 1.223 pacientes consecutivos foram submetidos a implante inicial (n= 634) ou troca do gerador de pulsos (n= 589). Foram observados 70 episódios de complicação em 63 pacientes (5,1%). A incidência de readmissões hospitalares em um ano foi de 16,4% (IC 95% 13,7% - 19,6%) após implantes iniciais e 10,6% (IC 95% 8,3% - 13,4%) após trocas de geradores. Doença renal crônica, histórico de acidente vascular encefálico, tempo de permanência hospitalar, necessidade de cuidados intensivos pós-operatórios, complicações e readmissões hospitalares mostraram um impacto significativo sobre o custo anual total do tratamento. CONCLUSÕES: Os resultados confirmam a influência da idade, comorbidades, complicações pós-operatórias e readmissões hospitalares como fatores associados ao incremento do custo total anual do tratamento de pacientes com marca-passo.


Asunto(s)
Marcapaso Artificial , Readmisión del Paciente , Humanos , Marcapaso Artificial/economía , Marcapaso Artificial/efectos adversos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Readmisión del Paciente/economía , Factores de Tiempo , Anciano de 80 o más Años , Estudios Prospectivos , Complicaciones Posoperatorias/economía , Brasil , Costos de la Atención en Salud/estadística & datos numéricos , Factores de Riesgo , Tiempo de Internación/economía
18.
Port J Card Thorac Vasc Surg ; 31(1): 57-58, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38743518

RESUMEN

Surgical resection remains the optimal therapeutic option for early-stage operable NSCLC. Despite significant advances in recent years related to anesthetic and surgical techniques, cardiopulmonary complications remain major causes for postoperative morbimortality. In this paper we present a case of a patient who developed complete AV block followed by asystole after lung resection surgery. The patient underwent surgery via right VATS and the procedure was uneventful.  On the first post-operative day patient developed a third-degree atrioventricular block followed by 6 seconds asystole. Pharmacological treatment was instituted and implementation of a permanent pacemaker occurred on the third post-operative day, without complications. The remaining postoperative course was uneventful and the patient was discharged home on the sixth post-operative day. It is the objective of the authors to report and highlight this rare and potencial fatal complication of lung resection.


Asunto(s)
Bloqueo Atrioventricular , Paro Cardíaco , Neoplasias Pulmonares , Neumonectomía , Humanos , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/diagnóstico , Paro Cardíaco/etiología , Neoplasias Pulmonares/cirugía , Neumonectomía/efectos adversos , Masculino , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Marcapaso Artificial/efectos adversos , Anciano , Cirugía Torácica Asistida por Video/efectos adversos , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología
20.
Sci Rep ; 14(1): 11130, 2024 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750100

RESUMEN

CMR at 3.0T in the presence of active cardiac implants remains a challenge due to susceptibility artifacts. Beyond a signal void that cancels image information, magnetic field inhomogeneities may cause distorted appearances of anatomical structures. Understanding influencing factors and the extent of distortion are a first step towards optimizing the image quality of CMR with active implants at 3.0T. All measurements were obtained at a clinical 3.0T scanner. An in-house designed phantom with a 3D cartesian grid of water filled spheres was used to analyze the distortion caused by four representative active cardiac devices (cardiac loop recorder, pacemaker, 2 ICDs). For imaging a gradient echo (3D-TFE) sequence and a turbo spin echo (2D-TSE) sequence were used. The work defines metrics to quantify the different features of distortion such as changes in size, location and signal intensity. It introduces a specialized segmentation technique based on a reaction-diffusion-equation. The distortion features are dependent on the amount of magnetic material in the active implants and showed a significant increase when measured with the 3D TFE compared to the 2D TSE. This work presents a quantitative approach for the evaluation of image distortion at 3.0T caused by active cardiac implants and serves as foundation for both further optimization of sequences and devices but also for planning of imaging procedures.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Artefactos , Marcapaso Artificial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA