Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.172
Filtrar
1.
J Neuroeng Rehabil ; 21(1): 82, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769565

RESUMEN

BACKGROUND: Assessments of arm motor function are usually based on clinical examinations or self-reported rating scales. Wrist-worn accelerometers can be a good complement to measure movement patterns after stroke. Currently there is limited knowledge of how accelerometry correlate to clinically used scales. The purpose of this study was therefore to evaluate the relationship between intermittent measurements of wrist-worn accelerometers and the patient's progression of arm motor function assessed by routine clinical outcome measures during a rehabilitation period. METHODS: Patients enrolled in in-hospital rehabilitation following a stroke were invited. Included patients were asked to wear wrist accelerometers for 24 h at the start (T1) and end (T2) of their rehabilitation period. On both occasions arm motor function was assessed by the modified Motor Assessment Scale (M_MAS) and the Motor Activity Log (MAL). The recorded accelerometry was compared to M_MAS and MAL. RESULTS: 20 patients were included, of which 18 completed all measurements and were therefore included in the final analysis. The resulting Spearman's rank correlation coefficient showed a strong positive correlation between measured wrist acceleration in the affected arm and M-MAS and MAL values at T1, 0.94 (p < 0.05) for M_MAS and 0.74 (p < 0.05) for the MAL values, and a slightly weaker positive correlation at T2, 0.57 (p < 0.05) for M_MAS and 0.46 - 0.45 (p = 0.06) for the MAL values. However, no correlation was seen for the difference between the two sessions. CONCLUSIONS: The results confirm that the wrist acceleration can differentiate between the affected and non-affected arm, and that there is a positive correlation between accelerometry and clinical measures. Many of the patients did not change their M-MAS or MAL scores during the rehabilitation period, which may explain why no correlation was seen for the difference between measurements during the rehabilitation period. Further studies should include continuous accelerometry throughout the rehabilitation period to reduce the impact of day-to-day variability.


Asunto(s)
Acelerometría , Brazo , Rehabilitación de Accidente Cerebrovascular , Humanos , Acelerometría/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Rehabilitación de Accidente Cerebrovascular/métodos , Rehabilitación de Accidente Cerebrovascular/instrumentación , Brazo/fisiopatología , Brazo/fisiología , Muñeca/fisiología , Dispositivos Electrónicos Vestibles , Actividad Motora/fisiología , Adulto , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/diagnóstico , Anciano de 80 o más Años
2.
Sensors (Basel) ; 24(10)2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38794079

RESUMEN

Modular control of the muscle, which is called muscle synergy, simplifies control of the movement by the central nervous system. The purpose of this study was to explore the synergy in both the frequency and movement domains based on the non-negative Tucker decomposition (NTD) method. Surface electromyography (sEMG) data of 8 upper limb muscles in 10 healthy subjects under wrist flexion (WF) and wrist extension (WE) were recorded. NTD was selected for exploring the multi-domain muscle synergy from the sEMG data. The results showed two synergistic flexor pairs, Palmaris longus-Flexor Digitorum Superficialis (PL-FDS) and Extensor Carpi Radialis-Flexor Carpi Radialis (ECR-FCR), in the WF stage. Their spectral components are mainly in the respective bands 0-20 Hz and 25-50 Hz. And the spectral components of two extensor pairs, Extensor Digitorum-Extensor Carpi Ulnar (ED-ECU) and Extensor Carpi Radialis-Brachioradialis (ECR-B), are mainly in the respective bands 0-20 Hz and 7-45 Hz in the WE stage. Additionally, further analysis showed that the Biceps Brachii (BB) muscle was a shared muscle synergy module of the WE and WF stage, while the flexor muscles FCR, PL and FDS were the specific synergy modules of the WF stage, and the extensor muscles ED, ECU, ECR and B were the specific synergy modules of the WE stage. This study showed that NTD is a meaningful method to explore the multi-domain synergistic characteristics of multi-channel sEMG signals. The results can help us to better understand the frequency features of muscle synergy and shared and specific synergies, and expand the study perspective related to motor control in the nervous system.


Asunto(s)
Electromiografía , Movimiento , Músculo Esquelético , Muñeca , Humanos , Músculo Esquelético/fisiología , Masculino , Muñeca/fisiología , Adulto , Movimiento/fisiología , Femenino , Adulto Joven , Procesamiento de Señales Asistido por Computador
3.
Ecotoxicol Environ Saf ; 278: 116349, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38714081

RESUMEN

BACKGROUND: Exposures to polyaromatic hydrocarbons (PAHs) contribute to cancer in the fire service. Fire investigators are involved in evaluations of post-fire scenes. In the US, it is estimated that there are up to 9000 fire investigators, compared to approximately 1.1 million total firefighting personnel. This exploratory study contributes initial evidence of PAH exposures sustained by this understudied group using worn silicone passive samplers. OBJECTIVES: Evaluate PAH exposures sustained by fire investigators at post-fire scenes using worn silicone passive samplers. Assess explanatory factors and health risks of PAH exposure at post-fire scenes. METHODS: As part of a cross-sectional study design, silicone wristbands were distributed to 16 North Carolina fire investigators, including eight public, seven private, and one public and private. Wristbands were worn during 46 post-fire scene investigations. Fire investigators completed pre- and post-surveys providing sociodemographic, occupational, and post-fire scene characteristics. Solvent extracts from wristbands were analyzed via gas chromatography-mass spectrometry (GC-MS). Results were used to estimate vapor-phase PAH concentration in the air at post-fire scenes. RESULTS: Fire investigations lasted an average of 148 minutes, standard deviation ± 93 minutes. A significant positive correlation (r=0.455, p<.001) was found between investigation duration and PAH concentrations on wristbands. Significantly greater time-normalized PAH exposures (p=0.039) were observed for investigations of newer post-fire scenes compared to older post-fire scenes. Regulatory airborne PAH exposure limits were exceeded in six investigations, based on exposure to estimated vapor-phase PAH concentrations in the air at post-fire scenes. DISCUSSION: Higher levels of off-gassing and suspended particulates at younger post-fire scenes may explain greater PAH exposure. Weaker correlations are found between wristband PAH concentration and investigation duration at older post-fire scenes, suggesting reduction of off-gassing PAHs over time. Exceedances of regulatory PAH limits indicate a need for protection against vapor-phase contaminants, especially at more recent post-fire scenes.


Asunto(s)
Bomberos , Exposición Profesional , Hidrocarburos Policíclicos Aromáticos , Siliconas , Humanos , Hidrocarburos Policíclicos Aromáticos/análisis , Exposición Profesional/análisis , Estudios Transversales , North Carolina , Adulto , Masculino , Femenino , Persona de Mediana Edad , Monitoreo del Ambiente/métodos , Contaminantes Ocupacionales del Aire/análisis , Cromatografía de Gases y Espectrometría de Masas , Muñeca
4.
Artículo en Inglés | MEDLINE | ID: mdl-38791764

RESUMEN

(1) Background: An elevated wrist circumference may indicate excess weight and cardiometabolic risk. The present study aims to identify wrist circumference cutoff points (WrC) to determine excess weight levels and predict cardiometabolic risk in adults. (2) Methods: A cross-sectional study was conducted with adults aged 20 to 59 years old, attending the outpatient clinic at University Hospital/Federal University of Sergipe HU/UFS-EBSERH. Demographic, anthropometric, biochemical, and blood pressure (BP) data were collected. Cardiometabolic risk was assessed, according to the global risk score (ERG) and Framingham score criteria. The descriptive analysis included calculating medians and frequencies of anthropometric, demographic, biochemical, and blood pressure variables. The gender and age of adult groups were compared using the Mann-Whitney test. Spearman's correlation coefficient and multiple regression analysis were used to assess the association between wrist circumference (WrC) and the variables mentioned above. The predictive validity of WrC in identifying excess weight levels and cardiometabolic risk was analyzed using the ROC curve. The sample consisted of 1487 adults aged 20 to 59 years, 55.7% of whom were female; (3) Results: WrC correlated positively with other adiposity indicators such as waist circumference and Body Mass Index. WrC was the anthropometric indicator most significantly associated with cardiometabolic risk factors. WrC cutoff points identified by the study for determining excess weight were categorized by gender and age group. For males aged 20 to 40 years and >40 years, respectively, the cutoff points for overweight were 17.1 cm and 17.3 cm, and for obesity, 17.9 cm and 17.5 cm. For females aged 20 to 40 years and >40 years, respectively, the cutoff points for overweight were 15.6 cm and 15.4 cm, and for obesity, 16.1 cm and 16 cm (4). Conclusions: Wrist circumference showed a significant correlation with other adiposity indicators and can be used to identify adults with excess weight and predict cardiometabolic risk.


Asunto(s)
Sobrepeso , Muñeca , Humanos , Adulto , Masculino , Femenino , Persona de Mediana Edad , Estudios Transversales , Muñeca/anatomía & histología , Adulto Joven , Sobrepeso/epidemiología , Factores de Riesgo , Enfermedades Cardiovasculares/epidemiología , Antropometría , Índice de Masa Corporal , Factores de Riesgo Cardiometabólico
5.
Int J Med Robot ; 20(3): e2640, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38794828

RESUMEN

BACKGROUND: Accurately estimating the 6D pose of snake-like wrist-type surgical instruments is challenging due to their complex kinematics and flexible design. METHODS: We propose ERegPose, a comprehensive strategy for precise 6D pose estimation. The strategy consists of two components: ERegPoseNet, an original deep neural network model designed for explicit regression of the instrument's 6D pose, and an annotated in-house dataset of simulated surgical operations. To capture rotational features, we employ an Single Shot multibox Detector (SSD)-like detector to generate bounding boxes of the instrument tip. RESULTS: ERegPoseNet achieves an error of 1.056 mm in 3D translation, 0.073 rad in 3D rotation, and an average distance (ADD) metric of 3.974 mm, indicating an overall spatial transformation error. The necessity of the SSD-like detector and L1 loss is validated through experiments. CONCLUSIONS: ERegPose outperforms existing approaches, providing accurate 6D pose estimation for snake-like wrist-type surgical instruments. Its practical applications in various surgical tasks hold great promise.


Asunto(s)
Redes Neurales de la Computación , Instrumentos Quirúrgicos , Muñeca , Humanos , Muñeca/cirugía , Diseño de Equipo , Fenómenos Biomecánicos , Algoritmos , Procedimientos Quirúrgicos Robotizados/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Imagenología Tridimensional/métodos , Rotación , Reproducibilidad de los Resultados , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Análisis de Regresión
6.
BMC Med Imaging ; 24(1): 101, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693510

RESUMEN

Bone strength depends on both mineral content and bone structure. Measurements of bone microstructure on specimens can be performed by micro-CT. In vivo measurements are reliably performed by high-resolution peripheral computed tomography (HR-pQCT) using dedicated software. In previous studies from our research group, trabecular bone properties on CT data of defatted specimens from many different CT devices have been analyzed using an Automated Region Growing (ARG) algorithm-based code, showing strong correlations to micro-CT.The aim of the study was to validate the possibility of segmenting and measuring trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens. Data from micro-CT was used as reference. The hypothesis was that the ARG-based in-house built software could be used for such measurements.HR-pQCT image data at two resolutions (61 and 82 µm isotropic voxels) from 23 fresh-frozen human forearms were analyzed. Correlations to micro-CT were strong, varying from 0.72 to 0.99 for all parameters except trabecular termini and nodes. The bone volume fraction had correlations varying from 0.95 to 0.98 but was overestimated compared to micro-CT, especially at the lower resolution. Trabecular separation and spacing were the most stable parameters with correlations at 0.80-0.97 and mean values in the same range as micro-CT.Results from this in vitro study show that an ARG-based software could be used for segmenting and measuring 3D trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens using micro-CT data as reference. Over-and underestimation of several of the bone structure parameters must however be taken into account.


Asunto(s)
Algoritmos , Hueso Esponjoso , Microtomografía por Rayos X , Humanos , Hueso Esponjoso/diagnóstico por imagen , Anciano , Masculino , Femenino , Persona de Mediana Edad , Muñeca/diagnóstico por imagen , Programas Informáticos , Anciano de 80 o más Años
7.
Aging Clin Exp Res ; 36(1): 108, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717552

RESUMEN

INTRODUCTION: Wrist-worn activity monitors have seen widespread adoption in recent times, particularly in young and sport-oriented cohorts, while their usage among older adults has remained relatively low. The main limitations are in regards to the lack of medical insights that current mainstream activity trackers can provide to older subjects. One of the most important research areas under investigation currently is the possibility of extrapolating clinical information from these wearable devices. METHODS: The research question of this study is understanding whether accelerometry data collected for 7-days in free-living environments using a consumer-based wristband device, in conjunction with data-driven machine learning algorithms, is able to predict hand grip strength and possible conditions categorized by hand grip strength in a general population consisting of middle-aged and older adults. RESULTS: The results of the regression analysis reveal that the performance of the developed models is notably superior to a simple mean-predicting dummy regressor. While the improvement in absolute terms may appear modest, the mean absolute error (6.32 kg for males and 4.53 kg for females) falls within the range considered sufficiently accurate for grip strength estimation. The classification models, instead, excel in categorizing individuals as frail/pre-frail, or healthy, depending on the T-score levels applied for frailty/pre-frailty definition. While cut-off values for frailty vary, the results suggest that the models can moderately detect characteristics associated with frailty (AUC-ROC: 0.70 for males, and 0.76 for females) and viably detect characteristics associated with frailty/pre-frailty (AUC-ROC: 0.86 for males, and 0.87 for females). CONCLUSIONS: The results of this study can enable the adoption of wearable devices as an efficient tool for clinical assessment in older adults with multimorbidities, improving and advancing integrated care, diagnosis and early screening of a number of widespread diseases.


Asunto(s)
Acelerometría , Fuerza de la Mano , Muñeca , Humanos , Fuerza de la Mano/fisiología , Masculino , Femenino , Anciano , Acelerometría/instrumentación , Acelerometría/métodos , Persona de Mediana Edad , Muñeca/fisiología , Dispositivos Electrónicos Vestibles , Anciano de 80 o más Años , Aprendizaje Automático
8.
Acta Odontol Scand ; 83: 230-237, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38699981

RESUMEN

OBJECTIVES: This systematic review aimed at evaluating the reliability of dental maturation (DM) according to Demirjian method compared to hand and wrist maturation (HWM) to assess skeletal maturity (SM) in growing subjects, to identify the teeth and the corresponding mineralisation stages related to the pubertal growth spurt (PGS). MATERIALS AND METHODS: PubMed, Scopus, and Web of Science were systematically searched until January 5th, 2024, to identify observational cross-sectional studies that assessed the reliability of Demirjian method compared to the HWM methods (i.e., Grave and Brown and Fishman) in growing subjects. The quality assessment was evaluated using the Joanna Briggs Institute (JBI) Critical Appraisal Checklist. RESULTS: Out of 136 papers suitable for title/abstract screening, 19 included studies. Of them, 17 papers showed the reliability of Demirjian DM method compared to HWM Fishman and Grave and Brown methods to assess SM in growing subjects. According to JBI Critical Appraisal Checklist, 12 papers were high-quality studies and 7 papers were medium-quality studies.  Conclusions: The mandibular second molar might be considered as the best indicator compared to other teeth and that the peak of growth occurs no earlier than stage F in females and stage G in males according to Demirjian method. Also, the mandibular canine might be analysed as indicator of SM in males, and results suggest that the peak of growth occurs no earlier than maturation stage F according to Demirjian method, only in male subjects. Further studies are needed to confirm these findings.


Asunto(s)
Muñeca , Humanos , Reproducibilidad de los Resultados , Calcificación de Dientes/fisiología , Determinación de la Edad por el Esqueleto/métodos , Mano , Determinación de la Edad por los Dientes/métodos , Estudios Transversales , Femenino , Masculino , Niño
9.
Pediatr Neurol ; 155: 171-176, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38669799

RESUMEN

BACKGROUND: One of the most common causes of carpal tunnel syndrome (CTS) in childhood is mucopolysaccharidosis (MPS). While ultrasonography (US) can aid in the diagnosis of CTS in adult patients, there is limited experience of this in the pediatric group. We aimed to investigate the results of wrist ultrasonography, which may be a candidate alternative to electrophysiological examination. METHODS: The participants were evaluated for symptoms, physical examination findings, electrophysiological tests and grayscale US. CTS was diagnosed in accordance with the American Academy of Orthopedic Surgeons Management of Carpal Tunnel Syndrome: Evidence-Based Clinical Practice Guideline. RESULTS: Included in the study were 27 MPS patients aged 4.5-32 years and 30 healthy control subjects aged 4.3-26 years. Of the 54 wrists in the MPS group, 30 were diagnosed with CTS. The median cross-sectional area (CSA) at the proximal carpal tunnel, the CSA at the forearm, and the wrist-forearm ratio (WFR) were higher in the wrists of the MPS with CTS group than in those without CTS and the healthy control subjects. The WFR cutoff of ≥1.35, 56.6% (95% CI: 437.4-74.5) sensitivity, and 89.8% (95% CI: 81.0-95.5) specificity were consistent with a diagnosis of CTS (receiver operating characteristics analysis, area under the curve = 0.775, 95% CI: 0.673-0.877). CONCLUSION: Although the US provides results with unsatisfactory specificity and sensitivity, it is a candidate for further investigation for the diagnosis of CTS because it is an innovative, noninvasive, and more accessible method. WFR value may produce more meaningful results than wrist or forearm nerve area measurements.


Asunto(s)
Síndrome del Túnel Carpiano , Mucopolisacaridosis , Ultrasonografía , Humanos , Síndrome del Túnel Carpiano/diagnóstico por imagen , Masculino , Ultrasonografía/normas , Mucopolisacaridosis/complicaciones , Mucopolisacaridosis/diagnóstico por imagen , Femenino , Niño , Adolescente , Adulto Joven , Adulto , Preescolar , Muñeca/diagnóstico por imagen , Sensibilidad y Especificidad , Conducción Nerviosa/fisiología
10.
J Neurosci Methods ; 407: 110136, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38642806

RESUMEN

BACKGROUND: In the pursuit of finer Brain-Computer Interface commands, research focus has shifted towards classifying EEG signals for multiple tasks. While single-joint multitasking motor imagery provides support, distinguishing between EEG signals from the same joint remains challenging due to their similar brain spatial distribution. NEW METHOD: We designed experiments involving three motor imagery tasks-wrist extension, wrist flexion, and wrist abduction-with six participants. Based on this, a single-joint multi-task motor imagery EEG signal recognition method using Empirical Wavelet Decomposition and Multi-Kernel Extreme Learning Machine is proposed. This method employs Empirical Wavelet Decomposition (EWT) for modal decomposition, screening, and reconstruction of raw EEG signals, feature extraction using Common Spatial Patterns (CSP), and classification using Multi-Kernel Extreme Learning Machine (MKELM). RESULTS: After EWT processing, differences in time and frequency characteristics between EEG signals of different classes were enhanced, with the MKELM model achieving an average recognition accuracy of 91.93 %. COMPARISON WITH OTHER METHODS AND CONCLUSIONS: We compared EWT with Empirical Mode Decomposition (EMD), Variational Mode Decomposition (VMD), Local Mean Decomposition (LMD), and Wavelet Packet Decomposition (WPD). The results showed that the differences between various types of EEG signals processed by EWT were the most pronounced. The MKELM model outperformed traditional machine learning models such as Extreme Learning Machine (ELM), Support Vector Machine (SVM), K-Nearest Neighbors (KNN), and Linear Discriminant Analysis (LDA) in terms of recognition performance, and also exhibited faster training speeds than deep learning models such as Bayesian Convolutional Neural Network (BCNN) and Attention-based Dual-scale Fusion Convolutional Neural Network (ADFCNN). In summary, the proposed method provides a new approach for achieving finer Brain-Computer Interface commands.


Asunto(s)
Interfaces Cerebro-Computador , Electroencefalografía , Imaginación , Aprendizaje Automático , Análisis de Ondículas , Humanos , Electroencefalografía/métodos , Imaginación/fisiología , Adulto , Adulto Joven , Masculino , Procesamiento de Señales Asistido por Computador , Encéfalo/fisiología , Femenino , Actividad Motora/fisiología , Muñeca/fisiología
11.
J Biomech Eng ; 146(10)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38652569

RESUMEN

Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield deflecting or absorbing a projectile and deforming toward the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user. Two vulnerable locations along the upper extremity were investigated-the wrist and elbow-on eight postmortem human subjects (PMHS) using a pneumatic impacting apparatus for investigating the fracture threshold as a result of behind shield blunt trauma (BSBT). Impacting parameters were established by subjecting an augmented WorldSID anthropomorphic test device (ATD) positioned behind a ballistic shield to ballistic impacts. These data were used to form the impact parameters applied to PMHS, where the wrist most frequently fractured at the distal radius and the elbow most frequently fractured at the radial head. The fracture threshold for the wrist was 5663±1386 N (mean±standard deviation), higher than the elbow at 4765±894 N (though not significantly, p = 0.15). The failure impact velocity for wrist impacts was 17.7±2.1 m/s, while for the elbow, the failure impact velocity was 19.5±0.9 m/s. An approximate 10% risk of fracture threshold was identified on the modified WorldSID ATD (no flesh analogue included) to inform future protective standards.


Asunto(s)
Lesiones de Codo , Heridas no Penetrantes , Humanos , Masculino , Heridas no Penetrantes/etiología , Traumatismos de la Muñeca/etiología , Anciano , Persona de Mediana Edad , Fenómenos Biomecánicos , Anciano de 80 o más Años , Muñeca
12.
Sensors (Basel) ; 24(7)2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38610549

RESUMEN

Non-linear and dynamic systems analysis of human movement has recently become increasingly widespread with the intention of better reflecting how complexity affects the adaptability of motor systems, especially after a stroke. The main objective of this scoping review was to summarize the non-linear measures used in the analysis of kinetic, kinematic, and EMG data of human movement after stroke. PRISMA-ScR guidelines were followed, establishing the eligibility criteria, the population, the concept, and the contextual framework. The examined studies were published between 1 January 2013 and 12 April 2023, in English or Portuguese, and were indexed in the databases selected for this research: PubMed®, Web of Science®, Institute of Electrical and Electronics Engineers®, Science Direct® and Google Scholar®. In total, 14 of the 763 articles met the inclusion criteria. The non-linear measures identified included entropy (n = 11), fractal analysis (n = 1), the short-term local divergence exponent (n = 1), the maximum Floquet multiplier (n = 1), and the Lyapunov exponent (n = 1). These studies focused on different motor tasks: reaching to grasp (n = 2), reaching to point (n = 1), arm tracking (n = 2), elbow flexion (n = 5), elbow extension (n = 1), wrist and finger extension upward (lifting) (n = 1), knee extension (n = 1), and walking (n = 4). When studying the complexity of human movement in chronic post-stroke adults, entropy measures, particularly sample entropy, were preferred. Kinematic assessment was mainly performed using motion capture systems, with a focus on joint angles of the upper limbs.


Asunto(s)
Articulación del Codo , Extremidad Superior , Adulto , Humanos , Muñeca , Bases de Datos Factuales , Entropía
13.
Medicine (Baltimore) ; 103(14): e37684, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38579032

RESUMEN

BACKGROUND: Wrist arthroscopy technology is a surgical technology invented in recent years and widely used in clinical treatment of various wrist diseases. This study uses the methods of bibliometrics and visual analysis to understand the global research status, research hotspots, and future development trends of wrist arthroscopy. METHODS: The relevant literature of global publications on wrist arthroscopy from 2013 to 2023 was extracted from the Web of Science Core Collection database, and the annual output, cooperation, hot spots, research status, and development trend of this field were analyzed by using the bibliometric software (VOSviewers, CiteSpace, and the R package "Bibliometrix"). RESULTS: A total of 635 articles were included, from 2013 to 2023, the number of publications related to wrist arthroscopy showed an overall upward trend, the USA, France, and China are the top 3 countries in terms of the number of publications, whereas Mayo Clinic is the institution with the highest number of publications, Ho PC holds a core position in this field, keyword analysis indicates that the research hotspots are the applications of wrist arthroscopy in triangular fibrocartilage complex injuries, scaphoid nonunion, and avascular necrosis of the lunate. CONCLUSION SUBSECTIONS: Wrist arthroscopy has shown tremendous potential in treating various wrist diseases. However, there are still some challenges in its research domain. With continuous deep research, strengthened international collaboration, and ongoing technological advancements, wrist arthroscopy has the potential to become the standard treatment in hand surgery, offering more efficient and safer treatment options for patients worldwide.


Asunto(s)
Artroscopía , Muñeca , Humanos , Instituciones de Atención Ambulatoria , Bibliometría , China
14.
BMC Musculoskelet Disord ; 25(1): 251, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38561698

RESUMEN

BACKGROUND: The purpose of this study was to examine two techniques for Carpal Tunnel Syndrome, mini-Open Carpal Tunnel Release (mini-OCTR) and Endoscopic Carpal Tunnel Release (ECTR), to compare their therapeutic efficacy. METHODS: Sixteen patients who underwent mini-OCTR in palmar incision and 17 patients who underwent ECTR in the wrist crease incision were included in the study. All patients presented preoperatively and at 1, 3, and 6 months postoperatively and were assessed with the Visual Analogue Scale (VAS) and the Disabilities of Arm, Shoulder and Hand Score (DASH). We also assessed the pain and cosmetic VAS of the entire affected hand or surgical wound, and the patient's satisfaction with the surgery. RESULTS: In the objective evaluation, both surgical techniques showed improvement at 6 months postoperatively. The DASH score was significantly lower in the ECTR group (average = 3 months: 13.6, 6 months: 11.9) than in the mini-OCTR group (average = 3 months: 27.3, 6 months: 20.6) at 3 and 6 months postoperatively. Also, the pain VAS score was significantly lower in the ECTR group (average = 17.1) than in the mini-OCTR group (average = 36.6) at 3 months postoperatively. The cosmetic VAS was significantly lower in the ECTR group (average = 1 month: 15.3, 3 months: 12.2, 6 months: 5.41) than in the mini-OCTR group (average = 1 month: 33.3, 3 months: 31.2, 6 months: 24.8) at all time points postoperatively. Patient satisfaction scores tended to be higher in the ECTR group (average = 3.3) compared to the mini-OCTR group (average = 2.7). CONCLUSIONS: ECTR in wrist increase incision resulted in better pain and cosmetic recovery in an early postoperative phase compared with mini-OCTR in palmar incision. Our findings suggest that ECTR is an effective technique for patient satisfaction.


Asunto(s)
Síndrome del Túnel Carpiano , Humanos , Síndrome del Túnel Carpiano/cirugía , Muñeca , Resultado del Tratamiento , Endoscopía/métodos , Dolor
15.
Sensors (Basel) ; 24(8)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38676160

RESUMEN

Optical Motion Capture Systems (OMCSs) are considered the gold standard for kinematic measurement of human movements. However, in situations such as measuring wrist kinematics during a hairdressing activity, markers can be obscured, resulting in a loss of data. Other measurement methods based on non-optical data can be considered, such as magneto-inertial measurement units (MIMUs). Their accuracy is generally lower than that of an OMCS. In this context, it may be worth considering a hybrid system [MIMU + OMCS] to take advantage of OMCS accuracy while limiting occultation problems. The aim of this work was (1) to propose a methodology for coupling a low-cost MIMU (BNO055) to an OMCS in order to evaluate wrist kinematics, and then (2) to evaluate the accuracy of this hybrid system [MIMU + OMCS] during a simple hairdressing gesture. During hair cutting gestures, the root mean square error compared with the OMCS was 4.53° (1.45°) for flexion/extension, 5.07° (1.30°) for adduction/abduction, and 3.65° (1.19°) for pronation/supination. During combing gestures, they were significantly higher, but remained below 10°. In conclusion, this system allows for maintaining wrist kinematics in case of the loss of hand markers while preserving an acceptable level of precision (<10°) for ergonomic measurement or entertainment purposes.


Asunto(s)
Muñeca , Humanos , Fenómenos Biomecánicos/fisiología , Muñeca/fisiología , Masculino , Rango del Movimiento Articular/fisiología , Adulto , Movimiento/fisiología , Femenino
16.
Artículo en Inglés | MEDLINE | ID: mdl-38656862

RESUMEN

Illusory directional sensations are generated through asymmetric vibrations applied to the fingertips and have been utilized to induce upper-limb motions in the rehabilitation and training of patients with visual impairment. However, its effects on motor control remain unclear. This study aimed to verify the effects of illusory directional sensations on wrist motion. We conducted objective and subjective evaluations of wrist motion during a motor task, while inducing an illusory directional sensation that was congruent or incongruent with wrist motion. We found that, when motion and illusory directional sensations were congruent, the sense of agency for motion decreased. This indicates an induction sensation of the hand being moved by the illusion. Interestingly, although no physical force was applied to the hand, the angular velocity of the wrist was higher in the congruent condition than that in the no-stimulation condition. The angular velocity of the wrist and electromyography signals of the agonist muscles were weakly positively correlated, suggesting that the participants may have increased their wrist velocity. In other words, the congruence between the direction of motion and illusory directional sensation induced the sensation of the hand being moved, even though the participants' wrist-motion velocity increased. This phenomenon can be explained by the discrepancy between the sensation of active motion predicted by the efferent copy, and that of actual motion caused by the addition of the illusion. The findings of this study can guide the design of novel rehabilitation methods.


Asunto(s)
Electromiografía , Ilusiones , Movimiento , Vibración , Muñeca , Humanos , Ilusiones/fisiología , Masculino , Femenino , Muñeca/fisiología , Adulto Joven , Adulto , Movimiento/fisiología , Mano/fisiología , Voluntarios Sanos , Movimiento (Física) , Propiocepción/fisiología , Músculo Esquelético/fisiología , Percepción de Movimiento/fisiología , Desempeño Psicomotor/fisiología , Sensación/fisiología
17.
Sci Rep ; 14(1): 9765, 2024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684764

RESUMEN

Normal aging often results in an increase in physiological tremors and slowing of the movement of the hands, which can impair daily activities and quality of life. This study, using lightweight wearable non-invasive sensors, aimed to detect and identify age-related changes in wrist kinematics and response latency. Eighteen young (ages 18-20) and nine older (ages 49-57) adults performed two standard tasks with wearable inertial measurement units on their wrists. Frequency analysis revealed 5 kinematic variables distinguishing older from younger adults in a postural task, with best discrimination occurring in the 9-13 Hz range, agreeing with previously identified frequency range of age-related tremors, and achieving excellent classifier performance (0.86 AUROC score and 89% accuracy). In a second pronation-supination task, analysis of angular velocity in the roll axis identified a 71 ms delay in initiating arm movement in the older adults. This study demonstrates that an analysis of simple kinematic variables sampled at 100 Hz frequency with commercially available sensors is reliable, sensitive, and accurate at detecting age-related increases in physiological tremor and motor slowing. It remains to be seen if such sensitive methods may be accurate in distinguishing physiological tremors from tremors that occur in neurological diseases, such as Parkinson's Disease.


Asunto(s)
Brazo , Aprendizaje Automático , Movimiento , Muñeca , Humanos , Persona de Mediana Edad , Fenómenos Biomecánicos , Masculino , Femenino , Muñeca/fisiología , Adulto Joven , Adolescente , Brazo/fisiología , Movimiento/fisiología , Envejecimiento/fisiología , Adulto , Dispositivos Electrónicos Vestibles , Temblor/fisiopatología
18.
Sci Rep ; 14(1): 9206, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649731

RESUMEN

Periodic quantification of blood glucose levels is performed using painful, invasive methods. The proposed work presents the development of a noninvasive glucose-monitoring device with two sensors, i.e., finger and wrist bands. The sensor system was designed with a near-infrared (NIR) wavelength of 940 nm emitter and a 900-1700 nm detector. This study included 101 diabetic and non-diabetic volunteers. The obtained dataset was subjected to pre-processing, exploratory data analysis (EDA), data visualization, and integration methods. Ambiguities such as the effects of skin color, ambient light, and finger pressure on the sensor were overcome in the proposed 'niGLUC-2.0v'. niGLUC-2.0v was validated with performance metrics where accuracy of 99.02%, mean absolute error (MAE) of 0.15, mean square error (MSE) of 0.22 for finger, and accuracy of 99.96%, MAE of 0.06, MSE of 0.006 for wrist prototype with ridge regression (RR) were achieved. Bland-Altman analysis was performed, where 98% of the data points were within ± 1.96 standard deviation (SD), 100% were under zone A of the Clarke Error Grid (CEG), and statistical analysis showed p < 0.05 on evaluated accuracy. Thus, niGLUC-2.0v is suitable in the medical and personal care fields for continuous real-time blood glucose monitoring.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Humanos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Masculino , Femenino , Adulto , Dedos , Persona de Mediana Edad , Muñeca , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico
19.
Environ Pollut ; 349: 123877, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38574945

RESUMEN

Silicone wristbands are a noninvasive personal exposure assessment tool. However, despite their utility, questions remain about the rate at which chemicals accumulate on wristbands when worn, as validation studies utilizing wristbands worn by human participants are limited. This study evaluated the chemical uptake rates of 113 organic pollutants from several chemical classes (i.e., polychlorinated biphenyls (PCB), organophosphate esters (OPEs), alkyl OPEs, polybrominated diphenyl ethers (PBDEs), brominated flame retardants (BFR), phthalates, pesticides, and polycyclic aromatic hydrocarbons (PAHs) over a five-day period. Adult participants (n = 10) were asked to wear five silicone wristbands and then remove one wristband each day. Several compounds were detected in all participants' wristbands after only one day. The number of chemicals detected frequently (i.e. in at least seven participants wristbands) increased from 20% of target compounds to 26% after three days and more substantially increased to 34% of target compounds after four days of wear. Chemicals detected in at least seven participants' day five wristbands (n = 24 chemicals) underwent further statistical analysis, including estimating the chemical uptake rates over time. Some chemicals, including pesticides and phthalates, had postive and significant correlations between concentrations on wristbands worn five days and concentrations of wristbands worn fewer days suggesting chronic exposure. For 23 of the 24 compounds evaluated there was a statistically significant and positive linear association between the length of time wristbands were worn and chemical concentrations in wristbands. Despite the differences that exist between laboratory studies using polydimethylsiloxane (PDMS) environmental samplers and worn wristbands, these results indicate that worn wristbands are primarily acting as first-order kinetic samplers. These results suggest that studies using different deployment lengths should be comparable when results are normalized to the length of the deployment period. In addition, a shorter deployment period could be utilized for compounds that were commonly detected in as little as one day.


Asunto(s)
Monitoreo del Ambiente , Contaminantes Ambientales , Retardadores de Llama , Siliconas , Humanos , Adulto , Retardadores de Llama/análisis , Contaminantes Ambientales/análisis , Monitoreo del Ambiente/métodos , Masculino , Femenino , Exposición a Riesgos Ambientales/estadística & datos numéricos , Exposición a Riesgos Ambientales/análisis , Éteres Difenilos Halogenados/análisis , Bifenilos Policlorados/análisis , Hidrocarburos Policíclicos Aromáticos/análisis , Plaguicidas/análisis , Adulto Joven , Muñeca , Ácidos Ftálicos/análisis
20.
Ideggyogy Sz ; 77(3-4): 121-129, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38591925

RESUMEN

Background and purpose:

We aimed to investigate the difference of clinical and electrophysiological improvement between perineural corticosteroid injection therapy (PCIT) and perineural 5% dextrose injection therapy (5%PDIT) in carpal tunnel syndrome (CTS).

. Methods:

Total of 92 wrists that were diagnosed as mild-to-moderate idiopathic CTS and completed their follow-up were included in our study. The severity of pain, symptom severity and functional status were asses­sed by visual analog scale (VAS) and the Boston Carpal Tunnel Syndrome Questionnaire (BCTQ) scores for treatment effectiveness. Randomized wrists were administered PCIT or 5%PDIT accompanied by ultrasound guidance. VAS, BCTQ scores and the electro­physiological study repeated before and after treatment at the 1st and 6th months after perineural injection therapies (PITs) were recorded.

. Results:

Compared with baseline data, within groups there was significant improvement in VAS, BCTQ severity and function scores at 1st and 6th months follow-up (all p < 0.001). Considerable advance were detected in the median sensory nerve conduction velocity (SNCV) when pretreatment values were compared with posttreatment first month in both groups (p = 0.01; p < 0.001, respectively). No significant change occurred in median distal motor latency (DML) values between the 1st and 6th months in the groups (p = 0.095; p = 0.113, respectively). No significant difference was observed bet­ween 5%PDIT and PCIT groups.

. Conclusion:

Clinical and electrophysiologic improvement in CTS began from 1st month after PCIT and 5%PDIT. At the 6th month follow-up of the patients, 5%PDIT and PCIT had similar therapeutic effects. As a result, we can consider the replacement of PCIT with 5%PDIT in mild-to-moderate CTS patients especially in those who are hesitant because of the corticosteroid’s adverse effects.

.


Asunto(s)
Síndrome del Túnel Carpiano , Humanos , Síndrome del Túnel Carpiano/tratamiento farmacológico , Muñeca , Corticoesteroides/uso terapéutico , Resultado del Tratamiento , Glucosa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA