Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.892
Filtrar
1.
Int Ophthalmol ; 44(1): 274, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916687

RESUMEN

PURPOSE: This report presents the results of using cryopreserved umbilical amniotic membrane (cUAM) as an alternative mucosal graft for ocular surface reconstruction in cases of anophthalmic socket contracture (ASC), cicatricial entropion (CE), and conjunctival-scleral defects. METHODS: The study included patients who underwent non-commercial implantation of cUAM grafts (prepared by corneal banking methods) for ASC, CE, conjunctival defect, and scleral melting. The main success criteria for this study were the comfortable fitting of the ocular prosthesis in ASC patients, the natural eyelid position in CE patients, and the degree of conjunctivalisation in melting patients. RESULTS: cUAM transplantation was performed in 2 patients who could not use a prosthetic eye due to conjunctival contracture, 2 patients with CE, and 1 patient with conjunctival defect and 1 patient with conjunctival-scleral melting. The primary outcome was achieved in 83.3% (5/6) of patients. In one patient with CE, partial healing was achieved due to the persistence of CE in the medial upper eyelid. CONCLUSIONS: cUAM is a viable alternative to mucosal grafting for reconstructing the bulbar and palpebral conjunctival surface, fornix, and orbit, with reduced donor morbidity and shorter surgical time. Its regenerative ability allows for tissue defect healing and improves cosmetic appearance through epithelialization within weeks.


Asunto(s)
Amnios , Anoftalmos , Criopreservación , Procedimientos de Cirugía Plástica , Humanos , Amnios/trasplante , Masculino , Femenino , Criopreservación/métodos , Procedimientos de Cirugía Plástica/métodos , Adulto , Persona de Mediana Edad , Anoftalmos/cirugía , Entropión/cirugía , Entropión/etiología , Anciano , Conjuntiva/trasplante , Conjuntiva/cirugía , Esclerótica/cirugía , Esclerótica/trasplante , Contractura/cirugía , Contractura/etiología , Ojo Artificial , Enfermedades de la Conjuntiva/cirugía , Enfermedades de la Conjuntiva/etiología
2.
J Prosthet Dent ; 132(4): 842.e1-842.e4, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38744559

RESUMEN

The accurate replacement of a missing eye with an ocular prosthesis that matches the healthy eye in terms of color and dimension of the sclera and iris is crucial for individuals who have lost an eye from trauma or cancer. A method is shown for precisely imitating the patient's sclera in terms of translucency from the patient's healthy eye for the prosthetic eye by creating custom translucency tabs. It is a straightforward, effective, and time-saving method of improving results during prosthesis fabrication.


Asunto(s)
Ojo Artificial , Diseño de Prótesis , Esclerótica , Humanos , Estética
3.
Int Ophthalmol ; 44(1): 227, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38776029

RESUMEN

PURPOSE: Artificial eye users (AEUs) can experience a negative impact on psychological and emotional wellbeing, including reduced social functioning, which may be a consequence of living with one eye removed, and/or of having a prosthetic eye. This may have wider consequences for their families. We aimed to explore what it means to live with a prosthetic eye, for both AEUs and their families-and how any quality of life (QoL) issues impact on their day-to-day functioning. METHODS: A subset of AEUs and their family members taking part in a feasibility randomised controlled trial comparing hand-painted to digitally printed artificial eyes were invited for semi-structured interviews. Transcripts were analysed using reflexive thematic analysis. Qualitative results related to trial participation are covered elsewhere. Here, we focus on QoL and day-to-day functioning. RESULTS: Twelve AEUs (eight males) and five spouses (one male) who had worn artificial eyes for 2-65 years took part, and four themes were identified. (1) Impact on day-to-day life: AEUs and their spouses have to adapt to (partial) sight loss, reduced levels of confidence, and social withdrawal. (2) Impact on psychological and emotional wellbeing: distress among AEUs and their spouses can be severe and prolonged, highlight unmet support needs. (3) Challenges with treatment experiences: AEUs experienced negative impact of fragmentation of care and long waiting times. (4) Worries about the future: AEUs mentioned fragility of remaining sight, and concerns around potential need for further treatment. CONCLUSION: Patients and their family members experience negative impact of being an AEU on their everyday lives and quality of life. There is a potential role for psychosocial support services in supporting AEUs and their families even long after eye loss.


Asunto(s)
Ojo Artificial , Calidad de Vida , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Familia/psicología , Investigación Cualitativa , Ceguera/psicología
4.
BMC Ophthalmol ; 24(1): 150, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575898

RESUMEN

BACKGROUND: Limited studies have reported surgical outcomes that are defined by strict criteria following grade 2 or 3 socket reconstruction using an oral mucosal graft (OMG). We aimed to determine factors influencing surgical outcomes of anophthalmic socket reconstruction using OMG in patients with grade 2 or 3 socket contractures. METHODS: Thirty-seven patients who underwent socket reconstruction with autologous OMG between January 2007 and December 2017 were retrospectively analyzed. The successful outcome was defined as an eye prosthesis wearing without experiencing displacement and the absence of any re-operations or additional surgeries following socket reconstruction. Factors affecting surgical outcomes were identified using multivariate analysis. RESULTS: A total of 15 male and 22 female patients (mean age: 40.2 ± 17.2 years) were included. The median duration of socket contracture was 21.5 years. Grade 2 and 3 socket contractures, based on Tawfik's classification, were reported in 20 and 17 patients, respectively. Twenty-eight and eight patients underwent socket reconstruction using OMG alone and OMG combined with a hard palate graft, respectively. The success rates of grades 2 and 3 socket contracture reconstruction were 80.0% and 52.9%, respectively. Multivariate analysis demonstrated that only grade 3 contractures were predictive of worse outcomes. At the final visit (mean follow-up: 6.3 years), 34 patients (91.9%) could wear their eye prostheses. CONCLUSIONS: Socket reconstruction using autologous OMG can provide acceptable results in grade 2 and 3 contractures; however, satisfactory results were more significantly reported in grade 2 than in grade 3 contractures.


Asunto(s)
Anoftalmos , Contractura , Implantes Orbitales , Procedimientos de Cirugía Plástica , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Estudios Retrospectivos , Anoftalmos/cirugía , Ojo Artificial , Contractura/cirugía , Órbita/cirugía
5.
Sci Rep ; 14(1): 5292, 2024 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-38438495

RESUMEN

To evaluate the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00) and a diffractive trifocal IOL with + 2.17 D and + 3.25 D near addition (AcrySof IQ PanOptix TFNT00), we investigated the 10-week postoperative parameters after cataract surgery in which ZMB00 or TFNT00 lenses were implanted bilaterally from 2011 to 2020 (with a 3-month interval between implantation of the right and left lenses). The study included 1448 eyes of 724 patients. The diffractive bifocal group comprised 1326 eyes of 663 patients (aged 67.0 ± 7.8 years; females/males, 518/145), and the diffractive trifocal group comprised 122 eyes of 61 patients (aged 66.6 ± 7.3 years; females/males, 35/26). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Uncorrected near visual acuity and higher-order aberrations (ocular/internal, scaled to a pupil size of 4 mm) (Wavefront_4mm_postoperative_Ocular/Internal_Spherical) were significantly better in the bifocal group (p < 0.00068, Wald test). Uncorrected intermediate visual acuity, contrast sensitivity (6.3/4.0/2.5/1.6/1.0/0.7 degrees), and contrast sensitivity with glare (4.0/1.6/1.0/0.7 degrees) were significantly better in the trifocal group (p < 0.00068, Wald test).


Asunto(s)
Cristalino , Lentes Intraoculares , Lentes , Femenino , Masculino , Humanos , Ojo Artificial , Córnea
6.
BMC Ophthalmol ; 24(1): 126, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38504225

RESUMEN

BACKGROUND: This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery. The aim is to assess how these formulas perform across different corneal curvature ranges, thereby guiding more precise IOL selection. METHODS: In this retrospective case series, 336 eyes from 336 patients who underwent cataract surgery were studied. The cohort was divided into three groups according to preoperative corneal power. Key metrics analyzed included mean prediction error (PE), standard deviation of PE (SD), mean absolute prediction error (MAE), median absolute error (MedAE), and the percentage of eyes with PE within ± 0.25 D, 0.50 D, ± 0.75 D, ± 1.00 D and ± 2.00 D. RESULTS: In the flat K group (Km < 43 D), VRF-G, Emmetropia Verifying Optical Version 2.0 (EVO2.0), Kane, and Hoffer QST demonstrated lower SDs (± 0.373D, ± 0.379D, ± 0.380D, ± 0.418D, respectively) compared to the VRF formula (all P < 0.05). EVO2.0 and K6 showed significantly different SDs compared to Barrett Universal II (BUII) (all P < 0.02). In the medium K group (43 D ≤ Km < 46 D), VRF-G, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS recorded lower MAEs (0.307D to 0.320D) than Olsen (OLCR) and Castrop (all P < 0.03), with RBF3.0 having the second lowest MAE (0.309D), significantly lower than VRF and Olsen (OLCR) (all P < 0.05). In the steep K group (Km ≥ 46D), RBF3.0, K6, and Kane achieved significantly lower MAEs (0.279D, 0.290D, 0.291D, respectively) than Castrop (all P < 0.001). CONCLUSIONS: The study highlights the varying accuracy of newer IOL formulas based on corneal power. VRF-G, EVO2.0, Kane, K6, and Hoffer QST are highly accurate for flat corneas, while VRF-G, RBF3.0, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS are recommended for medium K corneas. In steep corneas, RBF3.0, K6, and Kane show superior performance.


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Estudios Retrospectivos , Córnea , Ojo Artificial , Biometría , Refracción Ocular , Óptica y Fotónica , Longitud Axial del Ojo
7.
PLoS One ; 19(3): e0299064, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38517869

RESUMEN

PURPOSE: This study aimed to assess the repeatability of intraocular lens (IOL) decentration measurements obtained through Pentacam, based on corneal topographic axis (CTA) and pupillary axis (PA), and to evaluate the level of agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. METHODS: In this prospective observational case series, three measurements were performed with Pentacam to evaluate the repeatability of the measurements. The analysis included the calculation of the mean and standard deviations (SD), conducting a repeated measures analysis of variance (rANOVA), and determining an intraclass correlation coefficient (ICC) to assess the repeatability of the measurements. Moreover, Bland-Altman analysis was employed to assess the agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. IOL decentration measurements were obtained with respect to both CTA and PA. RESULTS: A total of 40 eyes from 40 patients were analyzed. The rANOVA revealed no significant difference among three consecutive measurements of IOL decentration obtained with Pentacam. The mean SD of all parameters ranged from 0.04 mm to 0.07 mm. With CTA as the reference axis, the ICC values for Pentacam measurements of IOL decentration were 0.82 mm for the X-axis, 0.76 mm for the Y-axis, and 0.82 mm for spatial distance. When using PA as the reference axis, the corresponding ICC values were 0.87, 0.89, and 0.77, respectively. The 95% limits of agreement for all IOL decentration measurements were wide when comparing Pentacam and OPD-Scan III. CONCLUSIONS: Pentacam demonstrated high repeatability in measuring IOL decentration with respect to both CTA and PA. However, due to poor agreement between Pentacam and OPD-Scan III measurements, caution should be exercised when using data interchangeably between the two devices.


Asunto(s)
Lentes Intraoculares , Humanos , Córnea , Topografía de la Córnea , Ojo Artificial , Pupila , Reproducibilidad de los Resultados
8.
Cont Lens Anterior Eye ; 47(3): 102149, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38521700

RESUMEN

PURPOSE: To assess which signs and eye prosthesis care habits are related to subjective discomfort in patients with dry anophthalmic socket syndrome (DASS), using standardized tools from daily practice. METHODS: 62 anophthalmic sockets were compared with their healthy fellow eye using the Standard Patient Evaluation of Eye Dryness (SPEED) score. The correlations between SPEED questionnaire and the prosthesis care, discharge characteristics score, conjunctival inflammation score, meibomian gland dysfunction (MGD) scores and Schirmer I test were studied. RESULT: The anophthalmic sockets group achieved a higher SPEED test score (p < 0.01), discharge score (p < 0.01), conjunctival inflammation score (p < 0.01), MGD scores (p < 0.01) and lower Schirmer I test (p < 0.01) compared with their fellow, healthy eye. Patients with a prosthesis replacement of one year or less, those with a current fit time of one year or less and those with a cleaning frequency above one month reported better SPEED, (p < 0.01), conjunctiva inflammation (p < 0.01) and MGD scores (p < 0.01). CONCLUSION: Most anophthalmic patients suffer mild to severe DASS, which seems related to discharge, conjunctival inflammation and MGD. Moreover, certain practices related to the care of the prosthesis such as replacing with a frequency lower than yearly, current fitting time inferior to one year and a removing and cleaning regime above one month, were related to a lower discomfort sensation, conjunctival inflammation and MGD. Clinicians should consider the DASS when facing patients with anophthalmic socket and discomfort symptoms.


Asunto(s)
Anoftalmos , Síndromes de Ojo Seco , Ojo Artificial , Humanos , Femenino , Masculino , Persona de Mediana Edad , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/fisiopatología , Adulto , Anciano , Encuestas y Cuestionarios , Implantes Orbitales , Anciano de 80 o más Años , Adulto Joven
9.
Int Ophthalmol ; 44(1): 112, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38407686

RESUMEN

PURPOSE: To evaluate and compare the visual outcomes of an enhanced monofocal intraocular lens (IOL) with two different monofocal IOLs. SETTING: Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy. DESIGN: Prospective, single-center, single-masked, randomized controlled clinical study. METHODS: The study included patients undergoing phacoemulsification and IOL implantation. Patients were consecutively randomized by block randomization and assigned in a 1:1:1 allocation ratio to three study arms to bilaterally receive Tecnis Eyhance™ (model ICB00) or Tecnis® monofocal 1-piece (model PCB00) or Clareon® monofocal (model CNA0T0), respectively. Monocular and binocular (both corrected and uncorrected) visual acuities for far, intermediate and near were registered and compared among groups at 3 months. To track changes in patient quality of life, the Catquest-9SF questionnaire was administered to each patient before and after cataract extraction. RESULTS: Ninety patients (30 for each group) were enrolled. At 3 months follow-up, statistically significant differences for intermediate visual acuities were found between the three groups. Nonstatistically significant differences were observed for distance visual acuities and the changes in Catquest-9SF scores. CONCLUSION: Tecnis Eyhance™ provided better results in intermediate visual outcomes without adverse effects on patients' quality of life.


Asunto(s)
Lentes Intraoculares , Satisfacción del Paciente , Humanos , Estudios Prospectivos , Calidad de Vida , Ojo Artificial
10.
Nat Commun ; 15(1): 1360, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38413561

RESUMEN

Millions of people require custom ocular prostheses due to eye loss or congenital defects. The current fully manual manufacturing processes used by highly skilled ocularists are time-consuming with varying quality. Additive manufacturing technology has the potential to simplify the manufacture of ocular prosthetics, but existing approaches just replace to various degrees craftsmanship by manual digital design and still require substantial expertise and time. Here we present an automatic digital end-to-end process for producing custom ocular prostheses that uses image data from an anterior segment optical coherence tomography device and considers both shape and appearance. Our approach uses a statistical shape model to predict, based on incomplete surface information of the eye socket, a best fitting prosthesis shape. We use a colour characterized image of the healthy fellow eye to determine and procedurally generate the prosthesis's appearance that matches the fellow eye. The prosthesis is manufactured using a multi-material full-colour 3D printer and postprocessed to satisfy regulatory compliance. We demonstrate the effectiveness of our approach by presenting results for 10 clinic patients who received a 3D printed prosthesis. Compared to a current manual process, our approach requires five times less labour of the ocularist and produces reproducible output.


Asunto(s)
Miembros Artificiales , Ojo Artificial , Humanos , Diseño de Prótesis , Impresión Tridimensional , Implantación de Prótesis
11.
Int Ophthalmol ; 44(1): 96, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38372824

RESUMEN

PURPOSE: To assess the refractive accuracy of eight intraocular lens (IOL) formulas in eyes that underwent combined phacovitrectomy. METHODS: A retrospective chart review of 59 eyes that underwent uncomplicated phacovitrectomy between 2017 and 2020 at the Johns Hopkins Wilmer Eye Institute. Inclusion criteria were postoperative best corrected visual acuity of 20/40 or better within 6 months of surgery and IOL implantation in the capsular bag. The Barrett Universal II (BUII), Emmetropia Verifying Optical (EVOv2.0), Hill-Radial Basis Function (Hill-RBFv3.0), Hoffer Q, Holladay I, Kane, Ladas Super Formula (LSF), and SRK/T formulas were compared for accuracy in predicting postoperative spherical equivalents (SE) using Wilcoxon rank sum tests. Pearson's correlation coefficients were used to assess correlations between biometric parameters and errors for all formulas. RESULTS: Prediction errors of SE ranged from - 1.69 to 1.43 diopters (D), mean absolute errors (MAE) ranged from 0.39 to 0.47 D, and median absolute errors (MedAE) ranged from 0.23 to 0.37 D among all formulas. The BUII had the lowest mean error (- 0.043), MAE (0.39) and MedAE (0.23). The BUII also had the highest percentage of eyes with predicted error within ± 0.25 D (51%) and ± 0.50 D (83%). Based on MedAE however, no pairwise comparisons resulted in statistically significant differences. Axial length (AL) was positively correlated with the error from the Hoffer Q and Holladay I formulas (correlation coefficients = 0.34, 0.30, p values < 0.01, 0.02 respectively). CONCLUSION: While all eight IOL formulas had comparable accuracy in predicting refractive outcomes in eyes undergoing combined phacovitrectomy, the BUII and Kane formulas had a tendency to greater accuracy.


Asunto(s)
Ojo Artificial , Lentes Intraoculares , Humanos , Estudios Retrospectivos , Ojo , Refracción Ocular
12.
J Fr Ophtalmol ; 47(3): 104095, 2024 Mar.
Artículo en Francés | MEDLINE | ID: mdl-38382417

RESUMEN

Thermal shock can cause intraoperative opacification of a Carlevale (Soleko®) implant. This is a rare phenomenon which resolves spontaneously. It is crucial to recognise this phenomenon in order to avoid unnecessary and potentially harmful explantation decisions for the patient.


Asunto(s)
Ojo Artificial , Lentes Intraoculares , Humanos , Lentes Intraoculares/efectos adversos , Remoción de Dispositivos , Esclerótica/cirugía
13.
Int Ophthalmol ; 44(1): 32, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38329567

RESUMEN

PURPOSE: To explore the accuracy of the improved SRK/T-Li formula in eyes following implantation of intraocular lens (IOL) of less than 10 D as calculated by using the SRK/T formula in Chinese. METHODS: A total of 489 eyes from 489 patients with cataracts were included in this study. These patients were divided into a training set (271 patients) and a testing set (218 patients). The IOL power calculated by using SRK/T was less than 10 D. We evaluated the accuracy of the modified SRK/T-Li formula (P = PSRK/T × 0.8 + 2 (P = implanted IOL power; PSRK/T = IOL power calculated by SRK/T)). We evaluated the mean absolute error (MAE), percentage of prediction error (PE) within ± 0.25, ± 0.50, and ± 1.00 D, and the percentage of postoperative hyperopia. RESULTS: The MAE values in order of lowest to highest were as follows: 0.412 D (SRK/T-Li), 0.414 D (Barrett Universal II, (BUII)), 0.814 D (SRK/T), and 1.039 D (Holladay 1). The percentage of PE within ± 0.25 D, ± 0.50 D, and ± 1.00 D was 38.99%, 69.27% and 92.66% (BUII), 40.83%, 69.27% and 94.04% (SRK/T-Li), 20.64%, 41.28% and 71.56% (SRK/T), and 7.34%, 16.51% and 53.21% (Holladay 1), respectively. SRK/T-Li had the smallest postoperative hyperopic shift. CONCLUSIONS: For Chinese patients with an IOL power of less than 10 D as calculated by using the SRK/T, the SRK/T-Li has good accuracy and is the best choice to reduce postoperative hyperopic shift.


Asunto(s)
Catarata , Hiperopía , Lentes Intraoculares , Humanos , China , Ojo Artificial , Pueblos del Este de Asia
14.
PLoS One ; 19(2): e0288181, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38319899

RESUMEN

OBJECTIVES: To identify predictive factors and to construct predictive models using epidemiological and clinical preoperative factors for the visual acuity change after intracorneal ring segment (ICRS) implantation in patients with keratoconus. METHODS: The medical records of 287 keratoconic eyes of 230 patients implanted with ICRS at Chula Refractive Surgery Center of a tertiary university hospital (Bangkok, Thailand) between January 2012 and March 2022 were retrospectively reviewed for epidemiological and clinical preoperative variables, including those derived from Scheimpflug tomography. After randomly excluding one eye for each bilateral case, the remaining 230 eyes were randomized into two groups: a training group (184 eyes) and a validation group (46 eyes). In the training group, the correlation between the interesting variables and postoperative uncorrected and corrected distance visual acuity change (ΔUDVA and ΔCDVA; logMAR scale) at 6 months was explored, and then the multiple linear regression analysis was used to develop the predictive models. The obtained models were tested using the validation group. RESULTS: There were 5 and 14 preoperative variables that statistically correlated with ΔUDVA and ΔCDVA respectively. Only the preoperative corrected distance visual acuity (CDVAp) strongly correlated with ΔCDVA (Beta = -0.746). Using multiple regression, the preoperative uncorrected distance visual acuity (UDVAp) and front mean keratometry were selected in the proposed model for ΔUDVA (adjusted R2 = 38.8%), while the CDVAp and index of surface variance (ISV) were selected in the model [Formula: see text] (adjusted R2 = 48.9%). The ΔUDVA and ΔCDVA models were correct in 47.83% and 63.4% of the validation group within 0.20 logMAR, respectively. CONCLUSIONS: Potential predictive factors and models for ICRS-induced changes in visual acuity are proposed as adjunctive tools for clinicians. Such tools could be used for case selection and during counselling before ICRS implantation to maximize surgical outcomes.


Asunto(s)
Queratocono , Humanos , Sustancia Propia/cirugía , Topografía de la Córnea , Ojo Artificial , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis/métodos , Refracción Ocular , Estudios Retrospectivos , Tailandia
15.
Biomater Adv ; 158: 213792, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38281322

RESUMEN

Posterior capsule opacification (PCO), as one of the most common late complications after intraocular lens (IOL) implantation in cataract surgery, seriously affects patients' postoperative vision and surgical satisfaction, and can only be treated by laser incision of the posterior capsule. Although drug eluting coating modification have been proved to inhibit PCO effectively, the complicated coating methods and the potential toxicity of the antiproliferative drugs hinders its actual application. In this study, an indocyanine green (ICG) loaded polydopamine (PDA) coating modified IOL (IP-IOL) was designed to prevented PCO. In vitro and in vivo studies have shown that IP-IOL can effectively eliminate lens epithelial cells and significantly reduce the degree of PCO. At the same time, it still has good imaging quality and optical properties. Furthermore, both the near-infrared irradiation and ICG loaded PDA coating modified IOLs have proved to possess high biological safety to eyes. Thus, with easy preparation and safer near-infrared irradiated photothermal/photodynamic synchronous properties, such ICG loaded PDA coating provides an effective yet easier and safer PCO prevention after IOL implantation.


Asunto(s)
Opacificación Capsular , Lentes Intraoculares , Polímeros , Humanos , Opacificación Capsular/prevención & control , Ojo Artificial , Indoles/uso terapéutico , Verde de Indocianina/uso terapéutico
16.
J Prosthodont ; 33(3): 301-304, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37422858

RESUMEN

Various techniques have been described for the rehabilitation of ocular defects with ocular prostheses to restore lost anatomical structures and correct cosmetic defects. This article describes a technique for optimizing the position of an iris disk over a custom-made ocular prosthesis, by using eyeglasses with customized graph paper pattern lenses. It presents a simplified method that will be useful for people with ocular defects in remote and distant service areas with limited resources.


Asunto(s)
Ojo Artificial , Iris , Humanos , Diseño de Prótesis , Iris/cirugía , Cara
17.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 835-846, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658183

RESUMEN

BACKGROUND: Intraocular lenses (IOLs) require proper positioning in the eye to provide good imaging performance. This is especially important for premium IOLs. The purpose of this study was to develop prediction models for estimating IOL decentration, tilt and the axial IOL equator position (IOLEQ) based on preoperative biometric and tomographic measures. METHODS: Based on a dataset (N = 250) containing preoperative IOLMaster 700 and pre-/postoperative Casia2 measurements from a cataractous population, we implemented shallow feedforward neural networks and multilinear regression models to predict the IOL decentration, tilt and IOLEQ from the preoperative biometric and tomography measures. After identifying the relevant predictors using a stepwise linear regression approach and training of the models (150 training and 50 validation data points), the performance was evaluated using an N = 50 subset of test data. RESULTS: In general, all models performed well. Prediction of IOL decentration shows the lowest performance, whereas prediction of IOL tilt and especially IOLEQ showed superior performance. According to the 95% confidence intervals, decentration/tilt/IOLEQ could be predicted within 0.3 mm/1.5°/0.3 mm. The neural network performed slightly better compared to the regression, but without significance for decentration and tilt. CONCLUSION: Neural network or linear regression-based prediction models for IOL decentration, tilt and axial lens position could be used for modern IOL power calculation schemes dealing with 'real' IOL positions and for indications for premium lenses, for which misplacement is known to induce photic effects and image distortion.


Asunto(s)
Cristalino , Lentes Intraoculares , Humanos , Tomografía de Coherencia Óptica , Biometría , Ojo Artificial
18.
Retina ; 44(2): 324-332, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37851957

RESUMEN

PURPOSE: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. METHODS: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180° apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. RESULTS: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation ( P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length ( P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180° apart, the IOL may become decentered and tilted ( P < 0.01 and P < 0.05, respectively). CONCLUSION: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Ojo Artificial , Estudios Retrospectivos , Esclerótica/cirugía , Técnicas de Sutura
19.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 487-494, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37644329

RESUMEN

PURPOSE: To examine the feasibility and outcomes of a modified technique for the implantation of scleral fixated Carlevale intraocular lens (IOL) (I71 FIL SSF. Soleko IOL Division, Pontecorvo, Italy), and to analyze the occurrence of adverse events. METHODS: This is a retrospective observational study conducted revising patients charts from 2018 to 2023. Thirty-five eyes of 33 patients were included. Patients requiring IOL explantation had either IOL dislocation or opacification. The implantation of the Carlevale IOL was performed with the subconjunctival positioning of the anchors without any scleral flap. All maneuvers were performed transconjunctivally. The anatomical outcomes considered were IOL positioning, and the absence of postoperative complications. The functional outcomes analyzed were best correctedvisual acuity (BCVA) and refraction. RESULTS: In all the cases, the IOL was well positioned and centered postoperatively. No cases of conjunctival erosion were recorded. The best corrected visual acuity (BCVA) was 0.9±0.6 logMar (mean±standard deviation) preoperatively and 0.5±0.5 logMar (mean±standard deviation) postoperatively. The mean preoperative spherical equivalent was +6.8±7.7 dioptres, while postoperatively it was -1.1±1.6 dioptres. The most frequent procedure associated to secondary IOL implantation was posterior vitrectomy (25 eyes, 71.4%), which was performed with 25-gauge transconjunctival cannulas in the ciliary sulcus. The follow-up period was 24.5±16.9 months (mean±standard deviation). CONCLUSION: The described mini-invasive technique for Carlevale IOL implantation is safe and effective. It can be recommended either as a stand-alone operation or associated to concurrent surgical procedures.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Esclerótica/cirugía , Refracción Ocular , Ojo Artificial , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Técnicas de Sutura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA