Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
1.
Coron Artery Dis ; 31(1): 25-30, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34010182

RESUMEN

OBJECTIVES: To assess the diagnostic performance of computed tomography angiography (CTA) and intravascular ultrasound (IVUS) derived minimum lumen areas (MLA) from the same lesions that correspond to an FFR ≤0.80. METHODS AND RESULTS: A total of 24 patients (33 arteries) were collected retrospectively according to the following inclusion criteria: presence of a CTA diagnostic followed by an IVUS and FFR percutaneous coronary procedures. CTA and IVUS lumen contours were automatically performed using previously validated methods.The correlation between CTA and IVUS for the MLA was r = 0.45. In terms of MLA, the mean difference between CTA and IVUS was 0.81 mm2. Of note, a much smaller CTA-derived MLA (2.10 mm2) was found to be related to significant FFR lesions compared to that of the MLA derived from IVUS (3.19 mm2). The area under the curve, accuracy, sensitivity and specificity for this CTA-derived MLA were 0.80, 0.76, 0.50 and 0.87, respectively, while these values for IVUS-derived MLA were 0.87, 0.85, 0.80 and 0.87. CONCLUSIONS: Computed tomography angiography and intravascular ultrasound-derived minimum lumen areas have moderate diagnostic efficiency, albeit slightly better for IVUS, in identifying hemodynamically severe coronary stenoses. The utility of MLA, automatically derived from either CTA or IVUS as an alternative to FFR to guide the decision to revascularize, should be tested clinically.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Ultrasonografía Intervencional/métodos , Pesos y Medidas/normas , Anciano , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Estenosis Coronaria/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Ultrasonografía Intervencional/estadística & datos numéricos , Pesos y Medidas/instrumentación
2.
Schizophr Bull ; 48(2): 425-436, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34915570

RESUMEN

BACKGROUND: Digital phenotyping has been proposed as a novel assessment tool for clinical trials targeting negative symptoms in psychotic disorders (PDs). However, it is unclear which digital phenotyping measurements are most appropriate for this purpose. AIMS: Machine learning was used to address this gap in the literature and determine whether: (1) diagnostic status could be classified from digital phenotyping measures relevant to negative symptoms and (2) the 5 negative symptom domains (anhedonia, avolition, asociality, alogia, and blunted affect) were differentially classified by active and passive digital phenotyping variables. METHODS: Participants included 52 outpatients with a PD and 55 healthy controls (CN) who completed 6 days of active (ecological momentary assessment surveys) and passive (geolocation, accelerometry) digital phenotyping data along with clinical ratings of negative symptoms. RESULTS: Machine learning algorithms classifying the presence of a PD diagnosis yielded 80% accuracy for cross-validation in H2O AutoML and 79% test accuracy in the Recursive Feature Elimination with Cross Validation feature selection model. Models classifying the presence vs absence of clinically significant elevations on each of the 5 negative symptom domains ranged in test accuracy from 73% to 91%. A few active and passive features were highly predictive of all 5 negative symptom domains; however, there were also unique predictors for each domain. CONCLUSIONS: These findings suggest that negative symptoms can be modeled from digital phenotyping data recorded in situ. Implications for selecting the most appropriate digital phenotyping variables for use as outcome measures in clinical trials targeting negative symptoms are discussed.


Asunto(s)
Aprendizaje Automático/tendencias , Fenotipo , Trastornos Psicóticos/terapia , Pesos y Medidas/instrumentación , Adulto , Femenino , Humanos , Aprendizaje Automático/normas , Masculino , Persona de Mediana Edad , Trastornos Psicóticos/psicología , Pesos y Medidas/normas
3.
J Hepatol ; 76(2): 458-463, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34606912

RESUMEN

Clinical and experimental advances related to the detection, magnitude and pathobiology of subclinical portal hypertension in non-alcoholic fatty liver disease (NAFLD), primarily observed in the presence of non-alcoholic steatohepatitis (NASH), prompt us to revisit current disease paradigms. Hepatic venous pressure gradient (HVPG) has been reported to underestimate portal pressure in NASH-related cirrhosis, while inaccuracy is more likely in non-cirrhotic livers, indicating a potential need for new and preferably non-invasive methods of measurement. Although clinically significant portal hypertension (HVPG ≥10 mmHg) retains its prognostic significance in NASH, subclinical portal hypertension (HVPG 6.0-9.5 mmHg) has been repeatedly detected in patients with NAFLD in the absence of cirrhosis or even significant fibrosis whereas the impact of these findings on disease outcomes remains unclear. Mechanocrine signalling pathways in various types of liver cell reveal a molecular basis for the adverse effects of subclinical portal hypertension and suggest a bidirectional relationship between portal pressure and fibrosis. These findings may guide efforts to improve risk assessment and identify novel therapeutic targets in NAFLD.


Asunto(s)
Hipertensión Portal/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Pesos y Medidas/instrumentación , Humanos , Hipertensión Portal/fisiopatología , Enfermedad del Hígado Graso no Alcohólico/fisiopatología , Pronóstico , Índice de Severidad de la Enfermedad , Pesos y Medidas/normas
4.
Prenat Diagn ; 41(13): 1658-1667, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34647342

RESUMEN

OBJECTIVE: To create nomograms for fetal cardiothoracic (CT) ratio as assessed by three different 2-dimensional sonographic measurements, including CT diameter, circumference, and area ratios, in Thai fetuses with a gestational age (GA) of 17-37 weeks, and to evaluate both their correlation with GA or biparietal diameter (BPD) and variability among the three measurement methods. METHODS: Two-dimensional sonographic measurements of fetal CT ratio in 4-chamber view were assessed by three different measurement techniques. The 95% reference intervals and Z-scores of all measurement methods based on GA or BPD were constructed. Intraclass correlation coefficients (ICC) for the reproducibility of each technique were compared. RESULTS: A total of 511 uncomplicated singleton pregnancies were included. The fetal CT ratio values by all measurement techniques gradually and smoothly increased with increasing GA and BPD. The fetal CT circumference ratio showed the least correlation with both GA and BPD. The intraobserver and interobserver reliability coefficients of all techniques demonstrated almost excellent agreement (all ICCs at least 0.87). CONCLUSION: Reference intervals and Z-score reference ranges were developed using three different techniques for fetal CT ratio with a GA of 17-37 weeks. These nomograms are a simple and reliable screening tool for identifying abnormal fetal heart size.


Asunto(s)
Corazón Fetal/diagnóstico por imagen , Edad Gestacional , Nomogramas , Pesos y Medidas/normas , Adulto , Femenino , Corazón Fetal/fisiopatología , Humanos , Embarazo , Reproducibilidad de los Resultados , Ultrasonografía Prenatal/métodos , Ultrasonografía Prenatal/estadística & datos numéricos , Pesos y Medidas/instrumentación
5.
Medicine (Baltimore) ; 100(37): e27255, 2021 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-34664873

RESUMEN

ABSTRACT: This study was performed to determine whether red blood cell distribution width (RDW) is associated with 3-month poor functional outcome in patients undergoing thrombolytic therapy for acute ischemic stroke.RDW was measured in patients with thrombolytic therapy in emergency department. Functional outcome was assessed after 3 months and poor functional outcome was defined as modified Rankin scale 3 to 6.A total of 240 patients were enrolled, and 82 (34.2%) had a poor functional outcome. The median RDW was significantly elevated in patients with a poor functional outcome compare with those with a good outcome. RDW was independently associated with a 3-month poor functional outcome (odds ratio 3.369, 95% confidence interval 2.214-5.125). The optimal RDW cutoff for predicting 3-month poor functional outcome was 12.8%, and the area under the curve for RDW was 0.818 (95% confidence interval 0.761-0.876). The area under the curve for RDW was higher in male patients than in female patients. The RDW correlated positively with the modified Rankin scale score after 3 months and the initial National Institutes of Health Stroke Scale score.Initial higher RDW level is related to a 3-month poor functional outcome in patients undergoing thrombolytic therapy for acute ischemic stroke.


Asunto(s)
Eritrocitos/clasificación , Accidente Cerebrovascular Isquémico/complicaciones , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Terapia Trombolítica/normas , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Femenino , Humanos , Accidente Cerebrovascular Isquémico/epidemiología , Accidente Cerebrovascular Isquémico/mortalidad , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Evaluación de Resultado en la Atención de Salud/métodos , Pronóstico , Curva ROC , Estudios Retrospectivos , Seúl/epidemiología , Estadísticas no Paramétricas , Terapia Trombolítica/métodos , Terapia Trombolítica/estadística & datos numéricos , Pesos y Medidas/instrumentación
6.
Adv Skin Wound Care ; 34(9): 1-6, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34415258

RESUMEN

OBJECTIVE: To investigate the evolution of pressure-measuring devices used in compression treatment for venous leg ulcers and assess the most practical and effective devices to determine optimal pressure in compression therapy. DATA SOURCES: Relevant information was retrieved from databases including Google Scholar, PubMed, Wiley Online, and ScienceDirect without publication date restrictions. The keywords included venous leg ulcer, compression therapy, pressure measuring device, pressure sensor, and wireless system. STUDY SELECTION: Studies included in the review had to be published in English and discuss or compare pressure-measuring devices/sensors for compression therapy, the development of alternative sensors, and the applications of wireless technologies. Veterinary studies, conference proceedings, and unpublished articles were excluded. Applicable studies and articles were critically evaluated and synthesized. DATA EXTRACTION: After abstract review, 39 studies were identified. During full-text review, study details were collected using a data extraction form and organized into tables. Device attributes, accuracy, price, and limitations were categorized and analyzed. DATA SYNTHESIS: Studies disagree on the effectiveness and user-friendliness of existing pressure-measuring devices. These devices often impact user comfort and convenience, which are crucial factors in the adoption and use of wearable devices. Potential solutions for pressure-measuring devices with promising technologies were proposed: four feasible alternative sensors are described that could improve comfort and facilitate prolonged use under bandages. Advanced communication technologies may provide more convenience for users and practitioners. CONCLUSIONS: Conventional pressure-measuring devices used in compression therapy are not designed for the user's comfort and convenience. The use of flexible and stretchy pressure sensors (e-skin) provides good biocompatibility, conformability, and comfort and when integrated with near-field communication technology could address the drawbacks of current pressure-measuring devices.


Asunto(s)
Vendajes de Compresión/normas , Úlcera de la Pierna/terapia , Pesos y Medidas/instrumentación , Vendajes de Compresión/estadística & datos numéricos , Equipos y Suministros/normas , Humanos , Presión/efectos adversos
7.
Medicine (Baltimore) ; 100(33): e26988, 2021 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-34414978

RESUMEN

ABSTRACT: With the declining use of the pulmonary artery catheter (PAC), transesophageal echocardiography (TEE) has become an appealing alternative to obtain pulmonary artery pressure non-invasively using the simplified Bernoulli equation. The validation of this method in the perioperative setting has been scarce with no clear recommendations about which view is the most accurate to estimate right ventricular systolic pressure (RVSP).Therefore, we performed a prospective, observer-blinded, diagnostic test accuracy study to assess the difference in systolic pulmonary artery pressure (sysPAP) measuring both, invasively sysPAP and estimated RVSP with TEE in 3 different views: the mid-esophageal (ME) 4Chamber, the ME right ventricular (RV) inflow-outflow and the ME modified bicaval view.To show a clinically significant difference of at least 10% in RVSP, we included 40 cardiac surgical patients divided into 3 subgroups: Patients with mild to moderate tricuspid regurgitation (TR) and mean PAP <25 mm Hg, patients with mild to moderate TR and mean PAP≥ 25 mm Hg, and patients with severe TR.For the whole cohort, bias of estimated RVSP compared to measured sysPAP was 5.27 mm Hg, precision was 7.96 mm Hg, limits of agreement were -10.66 to 21.19 mm Hg. The best agreement between the 2 methods was found in patients with severe TR and in the ME RV inflow-outflow and the modified bicaval view. Good Doppler signals were available in 35% and 46% in these views, and in 20% in the ME 4 chamber view.The estimation of the sysPAP by TEE cannot be considered reliable in the clinical perioperative setting. Only measurements that provide a full Doppler envelope show sufficient precision to provide accurate estimations.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Hipertensión Arterial Pulmonar/clasificación , Pesos y Medidas/normas , Adulto , Anciano , Anciano de 80 o más Años , Presión Sanguínea/fisiología , Ecocardiografía Transesofágica/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Pesos y Medidas/instrumentación
8.
Medicine (Baltimore) ; 100(33): e26998, 2021 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-34414985

RESUMEN

BACKGROUND: Early diagnosis as well as treatment is important in management of congenital muscular torticollis (CMT). The purpose of this study was to find an effective physical therapy modality to improve the sternocleidomastoid (SCM) muscle thickness, the ratio of the SCM muscle thickness on the affected side to that on the non-affected side (A/N ratio), and head rotation in infant under 3 months of age diagnosed with CMT. METHODS AND ANALYSIS: A single-blind, randomized clinical trial was conducted. Participants were assigned in one of the 3 study groups through randomization. The treatment was performed 3 times a week for 30 minutes until the head tilt was ≤5 degrees. Group 1 was treated by handling for active or active-assist movement, group 2 was treated with passive stretching, and group 3 was treated with thermotherapy. For general characteristics, a χ2 test and 1-way analysis of variance were used. Intragroup differences were analyzed using a paired t test, and intergroup differences were analyzed using an age-adjusted analysis of covariance. RESULTS: After the intervention, there was no significant difference between groups in terms of SCM thickness on the affected side and A/N ratio (P > .05). Degree of head rotation on the affected side showed significant differences between groups (P < .05), with Group 2 showing significantly better results than group 1 and group 3 (P < .05, both). CONCLUSION: Passive stretching treatment was more effective than other treatments of this study for improvement in degree of head rotation in CMT infants under 3 months of age. TRIAL REGISTRATION: The trial is registered at the Institutional Review Board of Sahmyook University (IRB number, 2-7001793-AB-N-012019103HR) and the Clinical Research Information Service (CRiS; registry number, KCT0004862).


Asunto(s)
Músculos/fisiopatología , Modalidades de Fisioterapia/normas , Esternón/fisiopatología , Tortícolis/congénito , Pesos y Medidas/normas , Humanos , Lactante , Modalidades de Fisioterapia/estadística & datos numéricos , Método Simple Ciego , Tortícolis/complicaciones , Tortícolis/terapia , Pesos y Medidas/instrumentación
9.
Nutr Hosp ; 38(5): 1009-1015, 2021 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-34223769

RESUMEN

INTRODUCTION: Introduction: some factors have been shown to be associated with survival in patients with pancreatic adenocarcinoma. Recently, some studies suggested that malnutrition, muscle mass, and inflammation might have an effect on survival in patients with pancreatic malignancy. Objectives: to investigate the association between psoas muscle mass, inflammation, nutritional status at the time of diagnosis, and survival in patients with pancreatic adenocarcinoma. Methods: this retrospective study included 219 patients diagnosed with pancreatic carcinoma. The nutritional status, inflammation, and psoas muscle mass of the patients at the time of diagnosis were evaluated. Nutritional status was assessed using the Prognostic Nutritional Index (PNI). Leucocyte count and neutrophil/lymphocyte ratio (NLR) were used for inflammation assessment. Psoas muscle mass was calculated by using abdominal computed tomography images of the patients. Results: the mean age of patients (80 female and 139 male) was 66.6 ± 11.7 years. According to the PNI results, 155 patients had a normal nutritional status (70 %), whereas 64 patients were malnourished (30 %). The survival of the patients with normal nutritional status was significantly longer than that of those who were malnourished (p < 0.001). There was no significant relationship between psoas muscle area, leucocyte count, NLR, and survival time. Conclusion: the survival of pancreatic adenocarcinoma patients with malnutrition at the time of diagnosis was significantly shorter than for patients without malnutrition.


INTRODUCCIÓN: Introducción: se ha demostrado que algunos factores se asocian a la supervivencia en los pacientes con adenocarcinoma de páncreas. Recientemente, algunos estudios sugirieron que la desnutrición, la masa muscular y la inflamación podrían afectar a la supervivencia de los pacientes con neoplasias malignas pancreáticas. Objetivo: investigar la asociación entre masa muscular del psoas, inflamación, estado nutricional en el momento del diagnóstico y supervivencia en pacientes con adenocarcinoma de páncreas. Métodos: este estudio retrospectivo incluyó a 219 pacientes diagnosticados de carcinoma de páncreas. Se evaluaron el estado nutricional, la inflamación y la masa del músculo psoas de los pacientes en el momento del diagnóstico. El estado nutricional de los pacientes se evaluó con el Índice Nutricional Pronóstico (PNI). El recuento de leucocitos y el cociente de neutrófilos/linfocitos (NLR) se emplearon para la evaluación de la inflamación. La masa del músculo psoas se calculó utilizando las imágenes de tomografía computarizada abdominal de los pacientes. Resultados: la edad media de los pacientes (80 mujeres y 139 hombres) fue de 66,6 ± 11,7 años. Según los resultados del PNI, 155 pacientes tenían un estado nutricional normal (70 %) mientras que 64 pacientes estaban desnutridos (30 %). La supervivencia de los pacientes con estado nutricional normal fue significativamente mayor que la de los pacientes desnutridos (p < 0,001). No hubo ninguna relación significativa entre el área del músculo psoas, el recuento de leucocitos, el NLR y el tiempo de supervivencia. Conclusión: la supervivencia de los pacientes con adenocarcinoma de páncreas con desnutrición en el momento del diagnóstico fue significativamente menor que la de los pacientes sin desnutrición.


Asunto(s)
Adenoma/complicaciones , Inflamación/etiología , Estado Nutricional/fisiología , Neoplasias Pancreáticas/complicaciones , Músculos Psoas , Adenoma/fisiopatología , Anciano , Femenino , Humanos , Inflamación/fisiopatología , Masculino , Persona de Mediana Edad , Evaluación Nutricional , Neoplasias Pancreáticas/fisiopatología , Pronóstico , Estudios Retrospectivos , Pesos y Medidas/instrumentación
12.
Nutr Hosp ; 38(4): 729-735, 2021 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-34110225

RESUMEN

INTRODUCTION: Introduction: functional limitation is a result of sarcopenia and is associated with loss of skeletal muscle mass (SMM). Cost-effective methods are important for the identification of sarcopenia. Objective: to propose cutoff points for normalized calf circumference (CC) in order to identify low SMM in older women based on their functional limitation. Methods: in this descriptive, cross-sectional study the CC values of a young female sample (n = 78) were used to establish cutoff points (-2 SD) for low SMM in older women (n = 67). Functional limitation was identified by the six-minute walk test (≤ 400 m). CC was normalized by body mass, height, and BMI. The diagnostic accuracy of CC was calculated with a ROC curve, using functional limitation as standard. Results: cutoff points and area under the curve (AUC) were: CC (≤ 28.5; 0.62); CC·body mass-1 (≤ 0.40; 0.63); CC·height-2 (≤ 8.52; 0.55) and CC·BMI-1 (≤ 1.10; 0.73). Only CC·BMI-1 achieved a desirable accuracy (AUC > 0.7) to distinguish functional limitation. Conclusion: the accuracy attained supports the use of CC·BMI-1 to identify low SMM in older women. In the clinical context it is possible to predict the risk of sarcopenia when sophisticated methods for determining SMM are not available.


INTRODUCCIÓN: Introducción: la limitación funcional es consecuencia de la sarcopenia y se asocia con la pérdida de masa muscular esquelética (MME). Los métodos rentables son importantes para la identificación de la sarcopenia. Objetivo: proponer puntos de corte para la circunferencia de la pantorrilla (CP), normalizada para identificar un MME bajo en mujeres mayores en función de su limitación funcional. Métodos: en este estudio descriptivo de carácter transversal se utilizaron los valores de CP de una muestra de mujeres jóvenes (n = 78) para establecer los puntos de corte (-2 DS) de la MME baja en las mujeres mayores (n = 67). La limitación funcional se identificó mediante la prueba de la marcha de seis minutos (≤ 400 m). La CP se normalizó por la masa corporal, la altura y el IMC. La precisión diagnóstica de la CP se calculó con la curva ROC, utilizando como estándar la limitación funcional. Resultados: los puntos de corte y el área bajo la curva (AUC) fueron: CP (≤ 28,5; 0,62); CP·masa corporal-1 (≤ 0,40; 0,63); CP·altura-2 (≤ 8,52; 0,55) y CP·IMC-1 (≤ 1,10; 0,73). Solo el CP·IMC-1 logró la precisión deseable (AUC > 0,7) para distinguir la limitación funcional. Conclusión: la precisión alcanzada respalda el uso de CP·IMC-1 para identificar la MME baja en las mujeres mayores. En el contexto clínico es posible predecir el riesgo de sarcopenia cuando no se dispone de métodos sofisticados para determinar la MME.


Asunto(s)
Extremidad Inferior/fisiopatología , Músculo Esquelético/fisiología , Medición de Riesgo/normas , Anciano , Anciano de 80 o más Años , Antropometría/métodos , Área Bajo la Curva , Índice de Masa Corporal , Estudios Transversales , Femenino , Humanos , Extremidad Inferior/fisiología , Músculo Esquelético/anomalías , Músculo Esquelético/fisiopatología , Curva ROC , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos , Sarcopenia/diagnóstico , Sarcopenia/fisiopatología , Pesos y Medidas/instrumentación
13.
Crit Care ; 25(1): 196, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-34099028

RESUMEN

BACKGROUND: The evaluation of patient effort is pivotal during pressure support ventilation, but a non-invasive, continuous, quantitative method to assess patient inspiratory effort is still lacking. We hypothesized that the concavity of the inspiratory flow-time waveform could be useful to estimate patient's inspiratory effort. The purpose of this study was to assess whether the shape of the inspiratory flow, as quantified by a numeric indicator, could be associated with inspiratory effort during pressure support ventilation. METHODS: Twenty-four patients in pressure support ventilation were enrolled. A mathematical relationship describing the decay pattern of the inspiratory flow profile was developed. The parameter hypothesized to estimate effort was named Flow Index. Esophageal pressure, airway pressure, airflow, and volume waveforms were recorded at three support levels (maximum, minimum and baseline). The association between Flow Index and reference measures of patient effort (pressure time product and pressure generated by respiratory muscles) was evaluated using linear mixed effects models adjusted for tidal volume, respiratory rate and respiratory rate/tidal volume. RESULTS: Flow Index was different at the three pressure support levels and all group comparisons were statistically significant. In all tested models, Flow Index was independently associated with patient effort (p < 0.001). Flow Index prediction of inspiratory effort agreed with esophageal pressure-based methods. CONCLUSIONS: Flow Index is associated with patient inspiratory effort during pressure support ventilation, and may provide potentially useful information for setting inspiratory support and monitoring patient-ventilator interactions.


Asunto(s)
Capacidad Inspiratoria , Respiración Artificial/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Respiración Artificial/métodos , Respiración Artificial/estadística & datos numéricos , Mecánica Respiratoria/fisiología , Pesos y Medidas/instrumentación
14.
Int J Obes (Lond) ; 45(9): 2108-2117, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34172828

RESUMEN

OBJECTIVE: Cell diameter, area, and volume are established quantitative measures of adipocyte size. However, these different adipocyte sizing parameters have not yet been directly compared regarding their distributions. Therefore, the study aimed to investigate how these adipocyte size measures differ in their distribution and assessed their correlation with anthropometry and laboratory chemistry. In addition, we were interested to investigate the relationship between fat cell size and adipocyte mitochondrial respiratory chain capacity. METHODS: Subcutaneous and visceral histology-based adipocyte size estimates from 188 individuals were analyzed by applying a panel of parameters to describe the underlying cell population. Histology-based adipocyte diameter distributions were compared with adipocyte diameter distributions from collagenase digestion. Associations of mean adipocyte size with body mass index (BMI), glucose, HbA1C, blood lipids as well as mature adipocyte mitochondrial respiration were investigated. RESULTS: All adipocyte area estimates derived from adipose tissue histology were not normally distributed, but rather characterized by positive skewness. The shape of the size distribution depends on the adipocyte sizing parameter and on the method used to determine adipocyte size. Despite different distribution shapes histology-derived adipocyte area, diameter, volume, and surface area consistently showed positive correlations with BMI. Furthermore, associations between adipocyte sizing parameters and glucose, HbA1C, or HDL specifically in the visceral adipose depot were revealed. Increasing subcutaneous adipocyte diameter was negatively correlated with adipocyte mitochondrial respiration. CONCLUSIONS: Despite different underlying size distributions, the correlation with obesity-related traits was consistent across adipocyte sizing parameters. Decreased mitochondrial respiratory capacity with increasing subcutaneous adipocyte diameter could display a novel link between adipocyte hypertrophy and adipose tissue function.


Asunto(s)
Adipocitos/clasificación , Obesidad/fisiopatología , Pesos y Medidas/normas , Adipocitos/fisiología , Tejido Adiposo/metabolismo , Adulto , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mitocondrias/fisiología , Pesos y Medidas/instrumentación
15.
Medicine (Baltimore) ; 100(23): e26183, 2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-34115001

RESUMEN

BACKGROUND: With high diagnostic accuracy, magnetic resonance elastography (MRE) is a noninvasive tool and can be adopted to measure liver stiffness (LS). In this study, meta-analysis was carried out to further evaluate whether LS measured by MRE can predict early recurrence in patients with hepatocellular carcinoma (HCC). METHODS: PUBMED, EMBASE, Web of Science, China National Knowledge Infrastructure, and Cochrane Library database were searched for studies related to LS measured by MRE in the prediction of recurrence in patients with HCC. Survival outcome was estimated by hazard ratios and 95% confidence intervals. Meta-analysis was conducted with the Stata 16.0. RESULTS: The results of this meta-analysis will be submitted to a peer-reviewed journal for publication. CONCLUSION: This study will provide evidence support for LS measured by MRE in predicting the recurrence of HCC. ETHICS AND DISSEMINATION: The private information from individuals will not be published. This systematic review also should not damage participants' rights. Ethical approval is not available. The results may be published in a peer-reviewed journal or disseminated in relevant conferences. OSF REGISTRATION NUMBER: DOI 10.17605/ OSF.IO / SURH3.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Protocolos Clínicos , Diagnóstico por Imagen de Elasticidad/normas , Hígado/fisiopatología , Carcinoma Hepatocelular/clasificación , Diagnóstico por Imagen de Elasticidad/instrumentación , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Hígado/diagnóstico por imagen , Metaanálisis como Asunto , Modelos de Riesgos Proporcionales , Recurrencia , Revisiones Sistemáticas como Asunto , Pesos y Medidas/instrumentación , Pesos y Medidas/normas
16.
Fam Syst Health ; 39(1): 29-37, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34014728

RESUMEN

Shared decision making (SDM) has been gaining an increasing appeal in providing patient-centered health care, which focuses on patients' needs and values and their active role in making health-related decisions. However, SDM remains difficult to measure because different conceptual definitions have been used in the literature, resulting in different operational definitions and measurement approaches. In addition, traditional measurement approaches, such as self-reports, can fail to capture the dynamic nature of the SDM process. In this paper, we propose using sensor-based measurement (i.e., using sensors to collect objective and automated data in real time) to examine the SDM process to overcome the measurement challenges inherent in more traditional measurement approaches. We also call for further discussion on the role and feasibility of using sensors in studying SDM. Using a few sensors as an example, we discuss benefits and challenges of sensor-based measurement in this area. (PsycInfo Database Record (c) 2021 APA, all rights reserved).


Asunto(s)
Toma de Decisiones Conjunta , Relaciones Profesional-Familia , Humanos , Autoinforme , Pesos y Medidas/instrumentación
17.
Nutr Hosp ; 38(4): 704-709, 2021 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-34024110

RESUMEN

INTRODUCTION: Background: an association between low 25(OH)D levels and blood lipids has been identified in children, adolescents, and adults but not in the early stages of life, and a relation to carotid and aortic intima-media thickness has not been well studied and is controversial. Objective: to identify whether 25(OH)D levels are correlated with blood lipids and aortic and carotid intima-media thickness in infants aged 3 to 9 months. Methods: a cross-sectional study was conducted in 109 healthy term infants between the ages of 3 and 9 months. Serum vitamin D [25(OH)D], total cholesterol, HDL-cholesterol, non-HDL-cholesterol, and aortic and carotid intima-media thickness were measured. Feeding method, vitamin D supplementation, and sun exposure habits were recorded. Results: only 2.8 % (n = 3) and 10.1 % (n = 14) had vitamin D deficiency and insufficiency, respectively. Infants with inadequate levels of vitamin D were younger (< 6 months) (p = 0.004), and a lower percentage of their body surface area was exposed to the sun (p = 0.006). A significant positive correlation was found between 25(OH)D levels and non-HDL-cholesterol in the infants that consumed breastmilk substitutes (rho = 0.600, p < 0.001) or were partially breastfed (rho = 0.371, p = 0.026), whereas a positive correlation was found with total cholesterol in the infants receiving breastmilk substitutes (rho = 0.618, p < 0.001). No significant correlation was found between vitamin D and aortic or carotid intima-media thickness. Conclusions: there was a positive correlation between 25(OH)D levels and both total and non-HDL-cholesterol only in infants receiving breastmilk substitutes. The frequency of vitamin D deficiency and insufficiency was low.


INTRODUCCIÓN: Introducción: se ha identificado una asociación entre los niveles de 25(OH)D y de lípidos en sangre en los niños, adolescentes y adultos, pero no en las primeras etapas de la vida, mientras que la asociación con el grosor de la íntima-media aórtica (a-IMT) o carotídea (c-IMT) no se ha estudiado totalmente y es objeto de controversia. Objetivo: identificar si existe correlación entre los niveles de 25(OH)D y de lípidos en sangre y el a-IMT y c-IMT en lactantes de 3 a 9 meses. Métodos: se realizó un estudio transversal en 109 lactantes sanos de entre 3 y 9 meses de edad; se midieron la vitamina D sérica [25(OH)D], el colesterol total, el colesterol HDL, el colesterol no HDL, el a-IMT y el c-IMT. Se registraron el tipo de alimentación, la suplementación con vitamina D y la exposición solar. Resultados: aquellos con niveles inadecuados de vitamina D fueron los menores de 6 meses (p = 0,004) y los expuestos en un menor porcentaje de su cuerpo al sol (p = 0,006). Se encontró una correlación positiva significativa entre la 25(OH)D, el colesterol total (rho = 0,618, p < 0,001) y el colesterol no HDL (rho = 0,600, p < 0.001) en aquellos que consumían sustitutos de la leche materna. No se encontró correlación entre la vitamina D y el grosor de la íntima-media aórtica o carotídea. Solo el 2,8 % y el 10,1 % presentaron deficiencia e insuficiencia de vitamina D, respectivamente. Conclusiones: se encontró una correlación positiva entre los niveles de 25(OH)D, colesterol total y colesterol no HDL en los lactantes que recibían sustitutos de la leche materna.


Asunto(s)
Aorta/fisiología , Grosor Intima-Media Carotídeo/clasificación , Lípidos/análisis , Vitamina D/análisis , Estudios Transversales , Femenino , Humanos , Lactante , Lípidos/sangre , Masculino , Factores de Riesgo , Vitamina D/sangre , Pesos y Medidas/instrumentación
18.
Adv Skin Wound Care ; 34(6): 309-312, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33979819

RESUMEN

OBJECTIVE: To evaluate the usability of a novel instrument (stoma ruler) to measure damaged peristomal skin in patients with an ostomy. METHODS: A wound ostomy and continence nurse used both the stoma ruler and a linear ruler to assess DET (discoloration, erosion, tissue overgrowth) scores and the height of protrusion above the skin of 10 patients with ileostomies and took photographs. The photographs were presented to five ostomy care nurses for reliability testing. The difference between the two methods was determined using paired Wilcoxon signed ranks test. PRIMARY OUTCOME MEASURE: Interrater reliability of the linear versus stoma ruler. RESULTS: The interrater reliabilities of the stoma ruler versus the linear ruler for the domain-area DET score were 0.95 (95% confidence interval, 0.89-0.99) and 0.68 (95% confidence interval, 0.42-0.89), respectively. Only nurse 5 reported a significant difference between the two rulers (z = -2.24, P = .03). CONCLUSIONS: In busy clinical settings, the stoma ruler is easy for ostomy care nurses to use to obtain accurate DET scores and the height of stoma protrusion above the skin. Observing the position of damaged skin using the clock marks on the stoma ruler enhance clinical description and reduce assessment variation among professionals.


Asunto(s)
Estomía/efectos adversos , Cuidados de la Piel/instrumentación , Pesos y Medidas/instrumentación , Pesos y Medidas/normas , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estomía/métodos , Estomía/estadística & datos numéricos , Reproducibilidad de los Resultados , Cuidados de la Piel/estadística & datos numéricos
19.
Prenat Diagn ; 41(7): 868-876, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33811672

RESUMEN

OBJECTIVE: To establish feasibility and reproducibility of fetal proportion volumetric measurements, using three-dimensional (3D) ultrasound and a Virtual Reality (VR) system. METHODS: Within a population-based prospective birth cohort, 3D ultrasound datasets of 50 fetuses in the late first trimester were collected by three ultrasonographers in a single research center. V-scope software was used for volumetric measurements of total fetus, extremities, head-trunk, head, trunk, thorax, and abdomen. All measurements were performed independently by two researchers. Intraobserver and interobserver reproducibility were analyzed using Bland and Altman methods. RESULTS: Intraobserver and interobserver analyses of volumetric measurements of total fetus, head-trunk, head, trunk, thorax and abdomen showed intraclass correlation coefficients above 0.979, coefficients of variation below 7.51% and mean difference below 3.44%. The interobserver limits of agreement were within the ±10% range for volumetric measurements of total fetus, head-trunk, head and trunk. The interobserver limits of agreement for extremities, thorax and abdomen were -26.09% to 4.77%, -14.14% to 10.00% and -14.47% to 8.83%, respectively. CONCLUSION: First trimester fetal proportion volumetric measurements using 3D ultrasound and VR are feasible and reproducible, except volumetric measurements of the fetal extremities. These novel volumetric measurements may be used in future research to enable detailed studies on first trimester fetal development and growth.


Asunto(s)
Primer Trimestre del Embarazo , Realidad Virtual , Pesos y Medidas/normas , Adulto , Femenino , Feto/diagnóstico por imagen , Edad Gestacional , Humanos , Embarazo , Estudios Prospectivos , Reproducibilidad de los Resultados , Ultrasonografía Prenatal/métodos , Pesos y Medidas/instrumentación
20.
Crit Care ; 25(1): 110, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33736672

RESUMEN

BACKGROUND: In patients ventilated with tidal volume (Vt) < 8 mL/kg, pulse pressure variation (PPV) and, likely, the variation of distensibility of the inferior vena cava diameter (IVCDV) are unable to detect preload responsiveness. In this condition, passive leg raising (PLR) could be used, but it requires a measurement of cardiac output. The tidal volume (Vt) challenge (PPV changes induced by a 1-min increase in Vt from 6 to 8 mL/kg) is another alternative, but it requires an arterial line. We tested whether, in case of Vt = 6 mL/kg, the effects of PLR could be assessed through changes in PPV (ΔPPVPLR) or in IVCDV (ΔIVCDVPLR) rather than changes in cardiac output, and whether the effects of the Vt challenge could be assessed by changes in IVCDV (ΔIVCDVVt) rather than changes in PPV (ΔPPVVt). METHODS: In 30 critically ill patients without spontaneous breathing and cardiac arrhythmias, ventilated with Vt = 6 mL/kg, we measured cardiac index (CI) (PiCCO2), IVCDV and PPV before/during a PLR test and before/during a Vt challenge. A PLR-induced increase in CI ≥ 10% defined preload responsiveness. RESULTS: At baseline, IVCDV was not different between preload responders (n = 15) and non-responders. Compared to non-responders, PPV and IVCDV decreased more during PLR (by - 38 ± 16% and - 26 ± 28%, respectively) and increased more during the Vt challenge (by 64 ± 42% and 91 ± 72%, respectively) in responders. ∆PPVPLR, expressed either as absolute or as percent relative changes, detected preload responsiveness (area under the receiver operating curve, AUROC: 0.98 ± 0.02 for both). ∆IVCDVPLR detected preload responsiveness only when expressed in absolute changes (AUROC: 0.76 ± 0.10), not in relative changes. ∆PPVVt, expressed as absolute or percent relative changes, detected preload responsiveness (AUROC: 0.98 ± 0.02 and 0.94 ± 0.04, respectively). This was also the case for ∆IVCDVVt, but the diagnostic threshold (1 point or 4%) was below the least significant change of IVCDV (9[3-18]%). CONCLUSIONS: During mechanical ventilation with Vt = 6 mL/kg, the effects of PLR can be assessed by changes in PPV. If IVCDV is used, it should be expressed in percent and not absolute changes. The effects of the Vt challenge can be assessed on PPV, but not on IVCDV, since the diagnostic threshold is too small compared to the reproducibility of this variable. TRIAL REGISTRATION: Agence Nationale de Sécurité du Médicament et des Produits de santé: ID-RCB: 2016-A00893-48.


Asunto(s)
Presión Sanguínea/fisiología , Pierna/fisiopatología , Rango del Movimiento Articular/fisiología , Volumen Sistólico/fisiología , Vena Cava Inferior/fisiopatología , Anciano , Distribución de Chi-Cuadrado , Femenino , Humanos , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Respiración Artificial/métodos , Estadísticas no Paramétricas , Volumen de Ventilación Pulmonar/fisiología , Vena Cava Inferior/diagnóstico por imagen , Pesos y Medidas/instrumentación , Pesos y Medidas/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA