Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26.328
Filtrar
1.
Radiat Oncol ; 19(1): 69, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38822385

RESUMEN

BACKGROUND: Multiple artificial intelligence (AI)-based autocontouring solutions have become available, each promising high accuracy and time savings compared with manual contouring. Before implementing AI-driven autocontouring into clinical practice, three commercially available CT-based solutions were evaluated. MATERIALS AND METHODS: The following solutions were evaluated in this work: MIM-ProtégéAI+ (MIM), Radformation-AutoContour (RAD), and Siemens-DirectORGANS (SIE). Sixteen organs were identified that could be contoured by all solutions. For each organ, ten patients that had manually generated contours approved by the treating physician (AP) were identified, totaling forty-seven different patients. CT scans in the supine position were acquired using a Siemens-SOMATOMgo 64-slice helical scanner and used to generate autocontours. Physician scoring of contour accuracy was performed by at least three physicians using a five-point Likert scale. Dice similarity coefficient (DSC), Hausdorff distance (HD) and mean distance to agreement (MDA) were calculated comparing AI contours to "ground truth" AP contours. RESULTS: The average physician score ranged from 1.00, indicating that all physicians reviewed the contour as clinically acceptable with no modifications necessary, to 3.70, indicating changes are required and that the time taken to modify the structures would likely take as long or longer than manually generating the contour. When averaged across all sixteen structures, the AP contours had a physician score of 2.02, MIM 2.07, RAD 1.96 and SIE 1.99. DSC ranged from 0.37 to 0.98, with 41/48 (85.4%) contours having an average DSC ≥ 0.7. Average HD ranged from 2.9 to 43.3 mm. Average MDA ranged from 0.6 to 26.1 mm. CONCLUSIONS: The results of our comparison demonstrate that each vendor's AI contouring solution exhibited capabilities similar to those of manual contouring. There were a small number of cases where unusual anatomy led to poor scores with one or more of the solutions. The consistency and comparable performance of all three vendors' solutions suggest that radiation oncology centers can confidently choose any of the evaluated solutions based on individual preferences, resource availability, and compatibility with their existing clinical workflows. Although AI-based contouring may result in high-quality contours for the majority of patients, a minority of patients require manual contouring and more in-depth physician review.


Asunto(s)
Inteligencia Artificial , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
2.
Technol Cancer Res Treat ; 23: 15330338241260646, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38841792

RESUMEN

OBJECTIVE: The purpose of this research was to compare two treatment techniques for oropharyngeal cancers: conventional linac-based static intensity-modulated radiotherapy (sIMRT) and helical tomotherapy (HT). The study examined several parameters, including target coverage, organs at risk, integral dose, and beam on time. Additionally, the study evaluated the doses to the parotid, temporomandibular joint, and pharyngeal constrictor muscles, which are important for swallowing. METHOD: The present study retrospectively analyzed the data of 13 patients with oropharyngeal cancer who underwent radiotherapy between 2019 and 2021. The treatment plans for each patient were regenerated using both sIMRT and HT treatment planning systems with the sequential boost method. The techniques were evaluated and compared based on dose-volume histogram, homogeneity index, and conformity index parameters. The target coverage and organs at risk were statistically compared for two techniques. Additionally, the doses received by the healthy tissue volume were obtained for integral dose evaluation. The beam on time for each technique was assessed. RESULTS: When considering planning target volume evaluation, there was no difference in Dmeans between the two techniques and sIMRT demonstrated higher D2% values compared to the HT. The HT technique had better results for all organs at risk, such as the parotid, temporomandibular joint, and pharyngeal constrictor muscle. As for integral dose, it has been shown that the sIMRT technique provides better protection compared to HT. In addition, the beam on time was also longer with the HT technique. CONCLUSION: Both techniques may provide optimal target coverage for patients with oropharyngeal cancer. HT conferred notable advantages, especially with regard to critical structures implicated in swallowing, such as the parotid, temporomandibular joint, and pharyngeal constrictor muscle, in comparison to sIMRT.


Asunto(s)
Órganos en Riesgo , Neoplasias Orofaríngeas , Glándula Parótida , Músculos Faríngeos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Articulación Temporomandibular , Humanos , Neoplasias Orofaríngeas/radioterapia , Glándula Parótida/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Articulación Temporomandibular/efectos de la radiación , Masculino , Estudios Retrospectivos , Músculos Faríngeos/efectos de la radiación , Femenino , Anciano , Persona de Mediana Edad
3.
Technol Cancer Res Treat ; 23: 15330338241252622, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38845139

RESUMEN

Purpose: The aim of this matched-pair cohort study was to evaluate the potential of intensity-modulated proton therapy (IMPT) for sparring of the pelvic bone marrow and thus reduction of hematotoxicity compared to intensity-modulated photon radiotherapy (IMRT) in the setting of postoperative irradiation of gynaecological malignancies. Secondary endpoint was the assessment of predictive parameters for the occurrence of sacral insufficiency fractures (SIF) when applying IMPT. Materials and Methods: Two cohorts were analyzed consisting of 25 patients each. Patients were treated with IMPT compared with IMRT and had uterine cervical (n = 8) or endometrial cancer (n = 17). Dose prescription, patient age, and diagnosis were matched. Dosimetric parameters delivered to the whole pelvic skeleton and subsites (ilium, lumbosacral, sacral, and lower pelvis) and hematological toxicity were evaluated. MRI follow-up for evaluation of SIF was only available for the IMPT group. Results: In the IMPT group, integral dose to the pelvic skeleton was significantly lower (23.4GyRBE vs 34.3Gy; p < 0.001), the average V5Gy, V10Gy, and V20Gy were reduced by 40%, 41%, and 28%, respectively, compared to the IMRT group (p < 0.001). In particular, for subsites ilium and lower pelvis, the low dose volume was significantly lower. Hematotoxicity was significantly more common in the IMRT group (80% vs 32%; p = 0009), especially hematotoxicity ≥ CTCAE II (36% vs 8%; p = 0.037). No patient in the IMPT group experienced hematotoxicity > CTCAE II. In the IMPT cohort, 32% of patients experienced SIF. Overall SIF occurred more frequently with a total dose of 50.4 GyRBE (37.5%) compared to 45 GyRBE (22%). No significant predictive dose parameters regarding SIF could be detected aside from a trend regarding V50Gy to the lumbosacral subsite. Conclusion: Low-dose exposure to the pelvic skeleton and thus hematotoxicity can be significantly reduced by using IMPT compared to a matched photon cohort. Sacral insufficiency fracture rates appear similar to reported rates for IMRT in the literature.


Asunto(s)
Médula Ósea , Neoplasias de los Genitales Femeninos , Terapia de Protones , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Humanos , Femenino , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Médula Ósea/efectos de la radiación , Médula Ósea/patología , Persona de Mediana Edad , Anciano , Neoplasias de los Genitales Femeninos/radioterapia , Adulto , Planificación de la Radioterapia Asistida por Computador , Órganos en Riesgo/efectos de la radiación , Tratamientos Conservadores del Órgano/métodos
4.
Sci Rep ; 14(1): 12589, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824238

RESUMEN

In order to study how to use pulmonary functional imaging obtained through 4D-CT fusion for radiotherapy planning, and transform traditional dose volume parameters into functional dose volume parameters, a functional dose volume parameter model that may reduce level 2 and above radiation pneumonia was obtained. 41 pulmonary tumor patients who underwent 4D-CT in our department from 2020 to 2023 were included. MIM Software (MIM 7.0.7; MIM Software Inc., Cleveland, OH, USA) was used to register adjacent phase CT images in the 4D-CT series. The three-dimensional displacement vector of CT pixels was obtained when changing from one respiratory state to another respiratory state, and this three-dimensional vector was quantitatively analyzed. Thus, a color schematic diagram reflecting the degree of changes in lung CT pixels during the breathing process, namely the distribution of ventilation function strength, is obtained. Finally, this diagram is fused with the localization CT image. Select areas with Jacobi > 1.2 as high lung function areas and outline them as fLung. Import the patient's DVH image again, fuse the lung ventilation image with the localization CT image, and obtain the volume of fLung different doses (V60, V55, V50, V45, V40, V35, V30, V25, V20, V15, V10, V5). Analyze the functional dose volume parameters related to the risk of level 2 and above radiation pneumonia using R language and create a predictive model. By using stepwise regression and optimal subset method to screen for independent variables V35, V30, V25, V20, V15, and V10, the prediction formula was obtained as follows: Risk = 0.23656-0.13784 * V35 + 0.37445 * V30-0.38317 * V25 + 0.21341 * V20-0.10209 * V15 + 0.03815 * V10. These six independent variables were analyzed using a column chart, and a calibration curve was drawn using the calibrate function. It was found that the Bias corrected line and the Apparent line were very close to the Ideal line, The consistency between the predicted value and the actual value is very good. By using the ROC function to plot the ROC curve and calculating the area under the curve: 0.8475, 95% CI 0.7237-0.9713, it can also be determined that the accuracy of the model is very high. In addition, we also used Lasso method and random forest method to filter out independent variables with different results, but the calibration curve drawn by the calibration function confirmed poor prediction performance. The function dose volume parameters V35, V30, V25, V20, V15, and V10 obtained through 4D-CT are key factors affecting radiation pneumonia. Establishing a predictive model can provide more accurate lung restriction basis for clinical radiotherapy planning.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Neumonitis por Radiación , Humanos , Neumonitis por Radiación/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Femenino , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Anciano , Pulmón/diagnóstico por imagen , Pulmón/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Adulto
5.
World J Surg Oncol ; 22(1): 147, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38831328

RESUMEN

BACKGROUND: Radio(chemo)therapy is often required in pelvic malignancies (cancer of the anus, rectum, cervix). Direct irradiation adversely affects ovarian and endometrial function, compromising the fertility of women. While ovarian transposition is an established method to move the ovaries away from the radiation field, surgical procedures to displace the uterus are investigational. This study demonstrates the surgical options for uterine displacement in relation to the radiation dose received.  METHODS: The uterine displacement techniques were carried out sequentially in a human female cadaver to demonstrate each procedure step by step and assess the uterine positions with dosimetric CT scans in a hybrid operating room. Two treatment plans (anal and rectal cancer) were simulated on each of the four dosimetric scans (1. anatomical position, 2. uterine suspension of the round ligaments to the abdominal wall 3. ventrofixation of the uterine fundus at the umbilical level, 4. uterine transposition). Treatments were planned on Eclipse® System (Varian Medical Systems®,USA) using Volumetric Modulated Arc Therapy. Data about maximum (Dmax) and mean (Dmean) radiation dose received and the volume receiving 14 Gy (V14Gy) were collected. RESULTS: All procedures were completed without technical complications. In the rectal cancer simulation with delivery of 50 Gy to the tumor, Dmax, Dmean and V14Gy to the uterus were respectively 52,8 Gy, 34,3 Gy and 30,5cc (1), 31,8 Gy, 20,2 Gy and 22.0cc (2), 24,4 Gy, 6,8 Gy and 5,5cc (3), 1,8 Gy, 0,6 Gy and 0,0cc (4). For anal cancer, delivering 64 Gy to the tumor respectively 46,7 Gy, 34,8 Gy and 31,3cc (1), 34,3 Gy, 20,0 Gy and 21,5cc (2), 21,8 Gy, 5,9 Gy and 2,6cc (3), 1,4 Gy, 0,7 Gy and 0,0cc (4). CONCLUSIONS: The feasibility of several uterine displacement procedures was safely demonstrated. Increasing distance to the radiation field requires more complex surgical interventions to minimize radiation exposure. Surgical strategy needs to be tailored to the multidisciplinary treatment plan, and uterine transposition is the most technically complex with the least dose received.


Asunto(s)
Cadáver , Preservación de la Fertilidad , Neoplasias Pélvicas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Útero , Humanos , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Preservación de la Fertilidad/métodos , Útero/efectos de la radiación , Útero/cirugía , Útero/patología , Neoplasias Pélvicas/radioterapia , Neoplasias Pélvicas/cirugía , Neoplasias Pélvicas/patología , Radioterapia de Intensidad Modulada/métodos , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría/métodos
6.
World J Surg Oncol ; 22(1): 125, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38720338

RESUMEN

BACKGROUND: To investigate the correlation between microinvasion and various features of hepatocellular carcinoma (HCC), and to clarify the microinvasion distance from visible HCC lesions to subclinical lesions, so as to provide clinical basis for the expandable boundary of clinical target volume (CTV) from gross tumor volume (GTV) in the radiotherapy of HCC. METHODS: HCC patients underwent hepatectomy of liver cancer in our hospital between July 2019 and November 2021 were enrolled. Data on various features and tumor microinvasion distance were collected. The distribution characteristics of microinvasion distance were analyzed to investigate its potential correlation with various features. Tumor size compared between radiographic and pathologic samples was analyzed to clarify the application of pathologic microinvasion to identify subclinical lesions of radiographic imaging. RESULTS: The average microinvasion distance was 0.6 mm, with 95% patients exhibiting microinvasion distance less than 3.0 mm, and the maximum microinvasion distance was 4.0 mm. A significant correlation was found between microinvasion and liver cirrhosis (P = 0.036), serum albumin level (P = 0.049). Multivariate logistic regression analysis revealed that HCC patients with cirrhosis had a significantly lower risk of microinvasion (OR = 0.09, 95%CI = 0.02 ~ 0.50, P = 0.006). Tumor size was overestimated by 1.6 mm (95%CI=-12.8 ~ 16.0 mm) on radiographic size compared to pathologic size, with a mean %Δsize of 2.96% (95%CI=-0.57%~6.50%). The %Δsize ranged from - 29.03% to 34.78%. CONCLUSIONS: CTV expanding by 5.4 mm from radiographic GTV could include all pathologic microinvasive lesions in the radiotherapy of HCC. Liver cirrhosis was correlated with microinvasion and were independent predictive factor of microinvasion in HCC.


Asunto(s)
Carcinoma Hepatocelular , Hepatectomía , Neoplasias Hepáticas , Invasividad Neoplásica , Carga Tumoral , Humanos , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Pronóstico , Hepatectomía/métodos , Anciano , Estudios de Seguimiento , Estudios Retrospectivos , Adulto , Planificación de la Radioterapia Asistida por Computador/métodos , Cirrosis Hepática/patología
7.
Biomed Phys Eng Express ; 10(4)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38697044

RESUMEN

Objective.The aim of this work was to develop a Phase I control chart framework for the recently proposed multivariate risk-adjusted Hotelling'sT2chart. Although this control chart alone can identify most patients receiving extreme organ-at-risk (OAR) dose, it is restricted by underlying distributional assumptions, making it sensitive to extreme observations in the sample, as is typically found in radiotherapy plan quality data such as dose-volume histogram (DVH) points. This can lead to slightly poor-quality plans that should have been identified as out-of-control (OC) to be signaled in-control (IC).Approach. We develop a robust iterative control chart framework to identify all OC patients with abnormally high OAR dose and improve them via re-optimization to achieve an IC sample prior to establishing the Phase I control chart, which can be used to monitor future treatment plans.Main Results. Eighty head-and-neck patients were used in this study. After the first iteration, P14, P67, and P68 were detected as OC for high brainstem dose, warranting re-optimization aimed to reduce brainstem dose without worsening other planning criteria. The DVH and control chart were updated after re-optimization. On the second iteration, P14, P67, and P68 were IC, but P40 was identified as OC. After re-optimizing P40's plan and updating the DVH and control chart, P40 was IC, but P14* (P14's re-optimized plan) and P62 were flagged as OC. P14* could not be re-optimized without worsening target coverage, so only P62 was re-optimized. Ultimately, a fully IC sample was achieved. Multiple iterations were needed to identify and improve all OC patients, and to establish a more robust control limit to monitor future treatment plans.Significance. The iterative procedure resulted in a fully IC sample of patients. With this sample, a more robust Phase I control chart that can monitor OAR doses of new plans was established.


Asunto(s)
Órganos en Riesgo , Control de Calidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Cabeza y Cuello/radioterapia , Algoritmos
8.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(4): 773-779, 2024 Apr 20.
Artículo en Chino | MEDLINE | ID: mdl-38708512

RESUMEN

OBJECTIVE: To investigate the dosimetric difference between manual and inverse optimization in 3-dimensional (3D) brachytherapy for gynecologic tumors. METHODS: This retrospective study was conducted among a total of 110 patients with gynecologic tumors undergoing intracavitary combined with interstitial brachytherapy or interstitial brachytherapy. Based on the original images, the brachytherapy plans were optimized for each patient using Gro, IPSA1, IPSA2 (with increased volumetric dose limits on the basis of IPSA1) and HIPO algorithms. The dose-volume histogram (DVH) parameters of the clinical target volume (CTV) including V200, V150, V100, D90, D98 and CI, and the dosimetric parameters D2cc, D1cc, and D0.1cc for the bladder, rectum, and sigmoid colon were compared among the 4 plans. RESULTS: Among the 4 plans, Gro optimization took the longest time, followed by HIPO, IPSA2 and IPSA1 optimization. The mean D90, D98, and V100 of HIPO plans were significantly higher than those of Gro and IPSA plans, and D90 and V100 of IPSA1, IPSA2 and HIPO plans were higher than those of Gro plans (P < 0.05), but the CI of the 4 plans were similar (P > 0.05). For the organs at risk (OARs), the HIPO plan had the lowest D2cc of the bladder and rectum; the bladder absorbed dose of Gro plans were significantly greater than those of IPSA1 and HIPO (P < 0.05). The D2cc and D1cc of the rectum in IPSA1, IPSA2 and HIPO plans were better than Gro (P < 0.05). The D2cc and D1cc of the sigmoid colon did not differ significantly among the 4 plans. CONCLUSION: Among the 4 algorithms, the HIPO algorithm can better improve dose coverage of the target and lower the radiation dose of the OARs, and is thus recommended for the initial plan optimization. Clinically, the combination of manual optimization can achieve more individualized dose distribution of the plan.


Asunto(s)
Algoritmos , Braquiterapia , Neoplasias de los Genitales Femeninos , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Braquiterapia/métodos , Femenino , Estudios Retrospectivos , Neoplasias de los Genitales Femeninos/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos
9.
J Cancer Res Clin Oncol ; 150(5): 280, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38802664

RESUMEN

PROPOSE: To evaluate the advantage of the manual adaptive plans comparing to the scheduled plans, and explored clinical factors predicting patients suitable for adaptive strategy. METHODS AND MATERIALS: Eighty two patients with weekly online cone-beam computed tomography (CBCT) were enrolled. The re-CT simulation was performed after 15 fractions and a manual adaptive plan was developed if a significant deviation of the planning target volume (PTV) was found. To evaluate the dosimetric benefit, D98, homogeneity index (HI) and conformity index (CI) for the planning target volume (PTV), as well as D2cc of the bowel, bladder, sigmoid and rectum were compared between manual adaptive plans and scheduled ones. The clinical factors influencing target motion during radiotherapy were analyzed by chi-square test and logistic regression analysis. RESULTS: The CI and HI of the manual adaptive plans were significantly superior to the scheduled ones (P = 0.0002, 0.003, respectively), demonstrating a better dose coverage of the target volume. Compared to the scheduled plans, D98 of the manual adaptive plans increased by 3.3% (P = 0.0002), the average of D2cc to the rectum, bladder decreased 0.358 Gy (P = 0.000034) and 0.240 Gy (P = 0.03), respectively. In addition, the chi-square test demonstrated that age, primary tumor volume, and parametrial infiltration were the clinical factors influencing target motion during radiotherapy. Multivariate analysis further identified the large tumor volume (≥ 50cm3, OR = 3.254, P = 0.039) and parametrial infiltration (OR = 3.376, P = 0.018) as the independent risk factors. CONCLUSION: We found the most significant organ motion happened after 15 fractions during treatment. The manual adaptive plans improved the dose coverage and decreased the OAR doses. Patients with bulky mass or with parametrial infiltration were highly suggested to adaptive strategy during definitive radiotherapy due to the significant organ motion.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias del Cuello Uterino , Humanos , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/patología , Persona de Mediana Edad , Anciano , Adulto , Tomografía Computarizada de Haz Cónico/métodos , Radiometría/métodos , Órganos en Riesgo/efectos de la radiación , Anciano de 80 o más Años
10.
Radiat Oncol ; 19(1): 54, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702761

RESUMEN

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is an emerging treatment alternative for patients with localized low and intermediate risk prostate cancer patients. As already explored by some authors in the context of conventional moderate hypofractionated radiotherapy, focal boost of the index lesion defined by magnetic resonance imaging (MRI) is associated with an improved biochemical outcome. The objective of this phase II trial is to determine the effectiveness (in terms of biochemical, morphological and functional control), the safety and impact on quality of life, of prostate SABR with MRI guided focal dose intensification in males with intermediate and high-risk localized prostate cancer. METHODS: Patients with intermediate and high-risk prostate cancer according to NCCN definition will be treated with SABR 36.25 Gy in 5 fractions to the whole prostate gland with MRI guided simultaneous integrated focal boost (SIB) to the index lesion (IL) up to 50 Gy in 5 fractions, using a protocol of bladder trigone and urethra sparing. Intra-fractional motion will be monitored with daily cone beam computed tomography (CBCT) and intra-fractional tracking with intraprostatic gold fiducials. Androgen deprivation therapy (ADT) will be allowed. The primary endpoint will be efficacy in terms of biochemical and local control assessed by Phoenix criteria and post-treatment MRI respectively. The secondary endpoints will encompass acute and late toxicity, quality of life (QoL) and progression-free survival. Finally, the subgroup of high-risk patients will be involved in a prospective study focused on immuno-phenotyping. DISCUSSION: To the best of our knowledge, this is the first trial to evaluate the impact of post-treatment MRI on local control among patients with intermediate and high-risk prostate cancer undergoing SABR and MRI guided focal intensification. The results of this trial will enhance our understanding of treatment focal intensification through the employment of the SABR technique within this specific patient subgroup, particularly among those with high-risk disease, and will help to clarify the significance of MRI in monitoring local responses. Hopefully will also help to design more personalized biomarker-based phase III trials in this specific context. Additionally, this trial is expected to be incorporated into a prospective radiomics study focused on localized prostate cancer treated with radiotherapy. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL SPONSOR: IRAD/SEOR (Instituto de Investigación de Oncología Radioterápica / Sociedad Española de Oncología Radioterápica). STUDY SETTING: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL STATUS: Protocol version number and date: v. 5/ 17 May-2023. Date of recruitment start: August 8, 2023. Date of recruitment completion: July 1, 2024.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Guiada por Imagen , Anciano , Humanos , Masculino , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Estudios Prospectivos , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Calidad de Vida , Radiocirugia/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Vejiga Urinaria/efectos de la radiación , Ensayos Clínicos Fase II como Asunto
11.
Biomed Phys Eng Express ; 10(4)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38714180

RESUMEN

Radiotherapy (RT) is one of the major treatment modalities among surgery and chemotherapy for carcinoma breast. The surface dose study of modified reconstructive constructive Mastectomy (MRM) breast is important due to the heterogeneity in the body contour and the conventional treatment angle to save the lungs and heart from the radiation. These angular entries of radiation beam cause an unpredictable dose deposition on the body surface, which has to be monitored. Thermoluminescent dosimeter (TLD) or optically stimulated luminescent dosimeter (nano OSLD) are commonly preferable dosimeters for this purpose. The surface dose response of TLD and nano OSLD during MRM irradiation has been compared with the predicted dose from the treatment planning system (TPS). The study monitored 100 MRM patients by employing a total 500 dosimeters consisting of TLD (n = 250) and nano OSLD (n = 250), during irradiation from an Elekta Versa HD 6 MV Linear accelerator. The study observed a variance of 3.9% in the dose measurements for TLD and 3.2% for nano OSLD from the planned surface dose, with a median percentage dose of 44.02 for nano OSLD and 40.30 for TLD (p value 0.01). There was no discernible evidence of variation in dose measurements attributable to differences in field size or from patient to patient. Additionally, no variation was observed in dose measurements when comparing the placement of the dosimeter from central to off-centre positions. In comparison, a minor difference in dose measurements were noted between TLD and nano OSLD, The study's outcomes support the applicability of both TLD and nano OSLD as effective dosimeters during MRM breast irradiation for surface dose evaluation.


Asunto(s)
Neoplasias de la Mama , Mastectomía , Dosificación Radioterapéutica , Dosimetría Termoluminiscente , Humanos , Femenino , Dosimetría Termoluminiscente/métodos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Planificación de la Radioterapia Asistida por Computador/métodos , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Persona de Mediana Edad , Dosis de Radiación , Adulto , Mama/efectos de la radiación , Mama/cirugía
12.
Sci Rep ; 14(1): 11120, 2024 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750131

RESUMEN

Very High Energy Electron (VHEE) beams are a promising alternative to conventional radiotherapy due to their highly penetrating nature and their applicability as a modality for FLASH (ultra-high dose-rate) radiotherapy. The dose distributions due to VHEE need to be optimised; one option is through the use of quadrupole magnets to focus the beam, reducing the dose to healthy tissue and allowing for targeted dose delivery at conventional or FLASH dose-rates. This paper presents an in depth exploration of the focusing achievable at the current CLEAR (CERN Linear Electron Accelerator for Research) facility, for beam energies >200 MeV. A shorter, more optimal quadrupole setup was also investigated using the TOPAS code in Monte Carlo simulations, with dimensions and beam parameters more appropriate to a clinical situation. This work provides insight into how a focused VHEE radiotherapy beam delivery system might be achieved.


Asunto(s)
Electrones , Método de Montecarlo , Dosificación Radioterapéutica , Humanos , Aceleradores de Partículas/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia/métodos , Radioterapia de Alta Energía/métodos , Radioterapia de Alta Energía/instrumentación
13.
Gulf J Oncolog ; 1(45): 7-14, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38774928

RESUMEN

INTRODUCTION: Technical innovations in radiation therapy treatment planning and delivery over the last two decades have changed the practice of radiation therapy dramatically. The benefit of improved dose homogeneity and better sparing of critical structures in helical tomotherapy compared with conventional linac-based IMRT has been reported. This study was conducted to compare acute toxicities (skin, mucous membrane, salivary gland and hematological) during treatment and overall treatment time in Head and Neck Cancer patients treated with IMRT and Helical Tomotherapy and to assess the quality of life of patients during treatment between two groups. MATERIALS AND METHODS: The study involved thirty patients with histologically proven Squamous cell carcinomas of Head and Neck. They were treated with concurrent chemoradiotherapy, to a dose of 60-70 Gray in 30-35 fractions. The study consists of 2 arms which are standard IMRT and Tomotherapy arm. Fifteen consecutive patients were treated under IMRT and 15 patients were treated under Helical tomotherapy, along with concurrent chemotherapy. After completion of planning, plans were evaluated and dose to the targets, organs at risk were tabulated. Patients were assessed weekly for acute toxicities (skin reactions, mucositis, xerostomia, haematological toxicities) during the course of the treatment as per RTOG criteria. Quality of life of patients were assessed using FACT/ NCCN HNSI questionnaire in local language at day 1, day 21 and at completion of radiotherapy. RESULTS: Grade 2-3 skin reactions, mucositis, anemia, leukopenia and thrombocytopenia were predominant in both arms. Treatment time from start of radiotherapy to completion of radiotherapy varied from 39 days to 68 days. Majority of patients completed radiotherapy within 50-56 days. Mean quality of life score did not show much difference between IMRT and tomotherapy arms. CONCLUSION: The study did not show any statistically significant difference in overall treatment time, acute toxicities- skin reactions, xerostomia, mucositis& hematological toxicities and quality of life of patients during radiotherapy between IMRT and Helical Tomotherapy. Dosimetric benefits of Tomotherapy over IMRT do not translate into clinical benefit in terms of reduced acute toxicities, lesser overall treatment time and better quality of life of patients. KEY WORDS: Head and Neck Carcinoma, IMRT, Tomotherapy, RTOG, toxicity, FACT/ NCCN HNSI, quality of life.


Asunto(s)
Neoplasias de Cabeza y Cuello , Calidad de Vida , Radioterapia de Intensidad Modulada , Humanos , Neoplasias de Cabeza y Cuello/radioterapia , Radioterapia de Intensidad Modulada/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Carcinoma de Células Escamosas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Traumatismos por Radiación/etiología
14.
Gulf J Oncolog ; 1(45): 94-99, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38774938

RESUMEN

PURPOSE: We report the use of online adaptive radiotherapy (OART) aiming to improve dosimetric parameters in the prostate cancer patient who had lower urinary tract symptoms that caused him not to adhere to the standard bladder filling protocol. METHODS AND MATERIALS: The reference treatment plan for adaptive radiotherapy plan was generated for the pelvis and the solitary bony lesion using the Ethos treatment planning system. For each treatment session, high-quality iterative reconstructed cone beam CT (CBCT) images were acquired, and the system automatically generated an optimal adaptive plan after verification of contours. Image-guided RT (IGRT) plans were also created using the reference plan recalculated on the CBCT scan and were compared with adaptive plans. RESULTS: The reference bladder volume in the planning CT scan was 173 cc, and the mean bladder volume difference over the course was 25.4% ± 16.6%. The ART offered superior target coverage for PTV 70 Gy over online IGRT (V95: 90.5 ± 3.2 % Vs 97.3 ± 0.4%; p=0.000) and the bladder was also better spared from the high dose (V65 Gy: 17.9 ± 9.1% vs 14.8 ± 3.6%; p=0.03). However, the mean rectum V65 doses were very similar in both plans. CONCLUSION: Managing the inconsistent bladder volume was feasible in the prostate cancer patient using the CBCT-guided OART and our analysis confirmed that adaptive plans offered better target coverage while sparing the bladder from high radiation doses in comparison to online IGRT plans. KEY WORDS: radiotherapy, CBCT, online adaptive radiotherapy, image-guided RT.


Asunto(s)
Neoplasias de la Próstata , Planificación de la Radioterapia Asistida por Computador , Vejiga Urinaria , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Planificación de la Radioterapia Asistida por Computador/métodos , Vejiga Urinaria/patología , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada de Haz Cónico/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Anciano
15.
Med Eng Phys ; 128: 104177, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38789214

RESUMEN

Prostate cancer patients with an enlarged prostate and/or excessive pubic arch interference (PAI) are generally considered non-eligible for high-dose-rate (HDR) brachytherapy (BT). Steerable needles have been developed to make these patients eligible again. This study aims to validate the dosimetric impact and performance of steerable needles within the conventional clinical setting. HDR BT treatment plans were generated, needle implantations were performed in a prostate phantom, with prostate volume > 55 cm3 and excessive PAI of 10 mm, and pre- and post-implant dosimetry were compared considering the dosimetric constraints: prostate V100 > 95 % (13.50 Gy), urethra D0.1cm3 < 115 % (15.53 Gy) and rectum D1cm3 < 75 % (10.13 Gy). The inclusion of steerable needles resulted in a notable enhancement of the dose distribution and prostate V100 compared to treatment plans exclusively employing rigid needles to address PAI. Furthermore, the steerable needle plan demonstrated better agreement between pre- and post-implant dosimetry (prostate V100: 96.24 % vs. 93.74 %) compared to the rigid needle plans (79.13 % vs. 72.86 % and 87.70 % vs. 81.76 %), with no major changes in the clinical workflow and no changes in the clinical set-up. The steerable needle approach allows for more flexibility in needle positioning, ensuring a highly conformal dose distribution, and hence, HDR BT is a feasible treatment option again for prostate cancer patients with an enlarged prostate and/or excessive PAI.


Asunto(s)
Braquiterapia , Agujas , Neoplasias de la Próstata , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Masculino , Braquiterapia/instrumentación , Humanos , Neoplasias de la Próstata/radioterapia , Fantasmas de Imagen , Próstata/efectos de la radiación
16.
J Radiat Res ; 65(3): 393-401, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38739893

RESUMEN

Hyaluronate gel injection (HGI) in the rectovaginal septum and vesicovaginal septum is effective in the setting of high-dose-rate image-guided adaptive brachytherapy (IGABT) for cervical cancer. We aimed to retrospectively investigate optimal conditions for HGI to achieve optimal dose distribution with a minimum number of HGI. We classified 50 IGABT plans of 13 patients with cervical cancer who received IGABT both with and without HGI in the rectovaginal septum and vesicovaginal septum into the following two groups: plan with (number of plans = 32) and plan without (number of plans = 18) HGI. The irradiation dose parameters of high-risk clinical target volume (CTVHR) and organs at risk per fraction were compared between these groups. We also developed the adjusted dose score (ADS), reflecting the overall irradiation dose status for four organs at risk and CTVHR in one IGABT plan and investigated its utility in determining the application of HGI. HGI reduced the maximum dose to the most exposed 2.0 cm3 (D2.0 cm3) of the bladder while increasing the minimum dose covering 90% of CTVHR and the percentage of CTVHR receiving 100% of the prescription dose in one IGABT plan without causing any associated complications. An ADS of ≥2.60 was the optimum cut-off value to decide whether to perform HGI. In conclusion, HGI is a useful procedure for improving target dose distribution while reducing D2.0 cm3 in the bladder in a single IGABT plan. The ADS can serve as a useful indicator for the implementation of HGI.


Asunto(s)
Braquiterapia , Geles , Ácido Hialurónico , Dosificación Radioterapéutica , Neoplasias del Cuello Uterino , Humanos , Femenino , Ácido Hialurónico/administración & dosificación , Braquiterapia/métodos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Radioterapia Guiada por Imagen/métodos , Inyecciones , Adulto , Órganos en Riesgo/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Factores de Tiempo , Estudios Retrospectivos
17.
Cancer Med ; 13(10): e7322, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38785309

RESUMEN

BACKGROUND AND PURPOSE: Respiratory movement has an important impact on the radiotherapy for lung tumor. Respiratory gating technology is helpful to improve the accuracy of target delineation. This study investigated the value of prospective and retrospective respiratory gating simulations in target delineation and radiotherapy plan design for solitary pulmonary tumors (SPTs) in radiotherapy. METHODS: The enrolled patients underwent CT simulation with three-dimensional (3D) CT non gating, prospective respiratory gating, and retrospective respiratory gating simulation. The target volumes were delineated on three sets of CT images, and radiotherapy plans were prepared accordingly. Tumor displacements and movement information obtained using the two respiratory gating approaches, as well as the target volumes and dosimetry parameters in the radiotherapy plan were compared. RESULTS: No significant difference was observed in tumor displacement measured using the two gating methods (p > 0.05). However, the internal gross tumor volumes (IGTVs), internal target volumes (ITVs), and planning target volumes (PTVs) based on the retrospective respiratory gating simulation were larger than those obtained using prospective gating (group A: pIGTV = 0.041, pITV = 0.003, pPTV = 0.008; group B: pIGTV = 0.025, pITV = 0.039, pPTV = 0.004). The two-gating PTVs were both smaller than those delineated on 3D non gating images (p < 0.001). V5Gy, V10Gy, V20Gy, V30Gy, and mean lung dose in the two gated radiotherapy plans were lower than those in the 3D non gating plan (p < 0.001); however, no significant difference was observed between the two gating plans (p > 0.05). CONCLUSIONS: The application of respiratory gating could reduce the target volume and the radiation dose that the normal lung tissue received. Compared to prospective respiratory gating, the retrospective gating provides more information about tumor movement in PTV.


Asunto(s)
Neoplasias Pulmonares , Planificación de la Radioterapia Asistida por Computador , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Masculino , Femenino , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Dosificación Radioterapéutica , Carga Tumoral , Adulto , Estudios Retrospectivos , Nódulo Pulmonar Solitario/radioterapia , Nódulo Pulmonar Solitario/diagnóstico por imagen , Estudios Prospectivos , Respiración
18.
Technol Cancer Res Treat ; 23: 15330338241256594, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38808514

RESUMEN

Purpose: Intensity-modulated radiotherapy (IMRT) is currently the most important treatment method for nasopharyngeal carcinoma (NPC). This study aimed to enhance prediction accuracy by incorporating dose information into a deep convolutional neural network (CNN) using a multichannel input method. Methods: A target conformal plan (TCP) was created based on the maximum planning target volume (PTV). Input data included TCP dose distribution, images, target structures, and organ-at-risk (OAR) information. The role of target conformal plan dose (TCPD) was assessed by comparing the TCPD-CNN (with dose information) and NonTCPD-CNN models (without dose information) using statistical analyses with the ranked Wilcoxon test (P < .05 considered significant). Results: The TCPD-CNN model showed no statistical differences in predicted target indices, except for PTV60, where differences in the D98% indicator were < 0.5%. For OARs, there were no significant differences in predicted results, except for some small-volume or closely located OARs. On comparing TCPD-CNN and NonTCPD-CNN models, TCPD-CNN's dose-volume histograms closely resembled clinical plans with higher similarity index. Mean dose differences for target structures (predicted TCPD-CNN and NonTCPD-CNN results) were within 3% of the maximum prescription dose for both models. TCPD-CNN and NonTCPD-CNN outcomes were 67.9% and 54.2%, respectively. 3D gamma pass rates of the target structures and the entire body were higher in TCPD-CNN than in the NonTCPD-CNN models (P < .05). Additional evaluation on previously unseen volumetric modulated arc therapy plans revealed that average 3D gamma pass rates of the target structures were larger than 90%. Conclusions: This study presents a novel framework for dose distribution prediction using deep learning and multichannel input, specifically incorporating TCPD information, enhancing prediction accuracy for IMRT in NPC treatment.


Asunto(s)
Aprendizaje Profundo , Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Carcinoma Nasofaríngeo/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias Nasofaríngeas/radioterapia , Órganos en Riesgo/efectos de la radiación , Radiometría/métodos , Redes Neurales de la Computación
19.
Asian Pac J Cancer Prev ; 25(5): 1529-1538, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38809624

RESUMEN

AIM: To evaluate the out-of-field dose associated with flattened (FF) and flattening filter-free (FFF) 6 and 10 MV X-ray beams in a TrueBeam linear accelerator (Linac). MATERIALS AND METHODS: Measurements were taken in a slab phantom using the metal oxide semiconductor field effect transistor (MOSFET) detector at varying depths (dmax, 5 cm, and 10 cm) for clinically relevant field sizes and up to 30 cm from the field edges for 6 and 10 MV FF and FFF beams in TrueBeam Linac. Dose calculation accuracy of the analytic anisotropic algorithm (AAA) and Acuros algorithm was investigated in the out-of-field region. Similarly, the out-of-field dose associated with volumetric modulated arc therapy (VMAT) head-and-neck plan delivered to a body phantom was evaluated. RESULTS: The out-of-field dose for both FF and FFF photon beams (6 and 10 MV) decreased with increasing distance from the field boundary and size. Furthermore, regardless of FF in the field, higher-energy photon beams were associated with lower out-of-field dose. Both algorithms underestimated the dose in the out-of-field region, with AAA failing to calculate the out-of-field dose at 15 cm from the field edge and Acuros failing to calculate out-of-field radiation at 20 cm. At 5 cm from the field edge, an average of 50% underestimation was observed, and at 10 cm, an average of 60% underestimation was observed for both FF and FFF (6 and 10 MV) beams. The VMAT head-and-neck plan performed with the FFF beam resulted in a lower out-of-field dose than the FF beam for a comparable dose distribution. CONCLUSION: Compared with flattened beams, the FFF modes on TrueBeam Linac exhibited a clinically relevant reduction in the out-of-field dose. Further dosimetric studies are warranted to determine the significant benefit of FFF beams across different cancer sites.


Asunto(s)
Algoritmos , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Aceleradores de Partículas/instrumentación , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Rayos X , Neoplasias de Cabeza y Cuello/radioterapia , Fotones/uso terapéutico
20.
Asian Pac J Cancer Prev ; 25(5): 1515-1528, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38809623

RESUMEN

PURPOSE: The current research compared radiobiological and dosimetric results for simultaneous integrated boost (SIB) plans employing RapidArc and IMRT planning procedures in oropharyngeal cancer from head-and-neck cancer (HNC) patients. MATERIALS AND METHODS: The indigenously developed Python-based software was used in this study for generation and analysis. Twelve patients with forty-eight total plans with SIB were planned using Rapid arc (2 and 3 arcs) and IMRT (7 and 9 fields) and compared with radiobiological models Lyman, Kutcher, Burman (LKB) and EUD (Equivalent Uniform Dose) along with physical index such as homogeneity index(HI), conformity index(CI) of target volumes. RESULTS: These models' inputs are the dose-volume histograms (DVHs) calculated by the treatment planning system (TPS). The values obtained vary from one model to the other for the same technique and patient. The maximum dose to the brainstem and spinal cord and the mean dose to the parotids were analysed both dosimetrically and radiobiologically, such as the LKB model effective volume, equivalent uniform dose, EUD-based normal tissue complication probability, and normal tissue integral dose. The mean and max dose to target volume with conformity, homogeneity index, tumor control probability compared with treatment times, and monitor units. CONCLUSION: Rapid arc (3 arcs) resulted in significantly better OAR sparing, dose homogeneity, and conformity. The findings indicate that the rapid arc plan has improved dose distribution in the target volume compared with IMRT, but the tumor control probability obtained for the two planning methods, Rapid arc (3 arcs) and IMRT (7 fields), are similar. The treatment time and monitor units for the Rapid arc (3 arcs) were superior to other planning methods and considered to be standard in head & neck radiotherapy.


Asunto(s)
Órganos en Riesgo , Neoplasias Orofaríngeas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias Orofaríngeas/radioterapia , Neoplasias Orofaríngeas/patología , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría/métodos , Radiobiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA