2.
Clin Chest Med ; 45(3): 543-553, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39069320

RESUMEN

For decades spirometry has been the benchmark test for capturing lung function in children but its recognized limitations required the development of other techniques. This article introduces novel techniques in lung function assessment for pediatric patients, including multiple breath washout, impulse oscillometry, structured light plethysmography, and electrical impedance tomography, and common themes in interpreting the results. Challenges include standardization, reference data, and clinical integration of these innovative tools. Further research is ongoing to optimize these tests for clinical use, especially in diverse populations and pediatric settings.


Asunto(s)
Pruebas de Función Respiratoria , Humanos , Niño , Pruebas de Función Respiratoria/métodos , Enfermedades Pulmonares/diagnóstico , Enfermedades Pulmonares/fisiopatología , Pletismografía/métodos , Impedancia Eléctrica , Espirometría/métodos , Pulmón/fisiología , Pulmón/fisiopatología , Pulmón/diagnóstico por imagen
3.
Radiat Prot Dosimetry ; 200(11-12): 1163-1166, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39016498

RESUMEN

Finger photo pulse plethysmography is a simple, inexpensive and non-invasive method for measurement of arterial stiffness. The objective is to assess the correlation of arterial stiffness in low back pain subjects with lumbar disc degeneration. Thirty-four back pain patients of both sexes in age group of 30-65 were included. Anthropometric measures like height, body weight, body mass index (BMI) were included. Stiffness index (SI) and reflection index (RI) were measured from the digital volume pulse waveform. There was a negative correlation between SI/RI and no correlation between SI and RI with BMI in both sexes. A significant correlation found between weight and BMI in both sexes. Arterial stiffness may not have any influence on disc degeneration. BMI showed some influence on disc degeneration and back pain.


Asunto(s)
Degeneración del Disco Intervertebral , Dolor de la Región Lumbar , Vértebras Lumbares , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Persona de Mediana Edad , Dolor de la Región Lumbar/etiología , Adulto , Degeneración del Disco Intervertebral/diagnóstico por imagen , Anciano , Imagen por Resonancia Magnética/métodos , Vértebras Lumbares/diagnóstico por imagen , Rigidez Vascular , Dedos , Índice de Masa Corporal , Pletismografía/métodos
4.
Expert Rev Respir Med ; 18(3-4): 227-236, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38829281

RESUMEN

BACKGROUND: Thoraco-abdominal asynchrony (TAA) is usually assessed by respiratory inductance plethysmography. The main parameter used for its assessment is the calculation of the phase angle based on Lissajous plots. However, there are some mathematical limitations to its use. RESEARCH DESIGN AND METHODS: Sequences of five breaths were selected from a) normal subjects, b) COPD patients, both at rest and during exercise, and c) patients with obstructive apnea syndrome. Automated analysis was performed calculating phase angle, loop rotation (clockwise or counterclockwise), global phase delay and loop area. TAA severity was estimated quantitatively and in subgroups. RESULTS: 2290 cycles were analyzed (55% clockwise rotation). Phase angle ranged from -86.90 to + 88.4 degrees, while global phase delay ranged from -179.75 to + 178.54. Despite a good correlation with global phase delay (p < 0.01, ANOVA test), phase angle and loop area were not able to correctly classify breaths with severe deviation and paradoxical movements (p=ns, Bonferroni post hoc test). CONCLUSIONS: Global phase delay covers the whole spectrum of TAA situations in a single value. It may be a relevant parameter for diagnosis and follow-up of clinical conditions leading to TAA. CLINICAL TRIAL REGISTRATION: The trial from which the traces were obtained was registered at ClinicalTrials.gov ;(identifier: NCT04597606).


Asunto(s)
Pletismografía , Enfermedad Pulmonar Obstructiva Crónica , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Abdomen/fisiopatología , Pletismografía/métodos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Respiración , Mecánica Respiratoria/fisiología
5.
Kidney Blood Press Res ; 49(1): 667-675, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38934146

RESUMEN

INTRODUCTION: The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance. METHODS: Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analysed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex sonography served as a reference method. RESULTS: In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 vs. 162 ± 5.3 ms, p < 0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 vs. 8.05 m/s at the fistula/non-fistula side, p = 0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume flow (r = 0.326 with p = 0.017). CONCLUSION: Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.


Asunto(s)
Pletismografía , Análisis de la Onda del Pulso , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pletismografía/métodos , Análisis de la Onda del Pulso/métodos , Anciano , Diálisis Renal , Oscilometría/métodos , Derivación Arteriovenosa Quirúrgica , Brazo/irrigación sanguínea , Adulto
6.
Nutrition ; 125: 112494, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38843564

RESUMEN

BACKGROUND AND AIMS: Measurement of body composition using computed tomography (CT) scans may be a viable clinical tool for low muscle mass assessment in oncology. However, longitudinal assessments are often infeasible with CT. Clinically accessible body composition technologies can be used to track changes in fat-free mass (FFM) or muscle, though their accuracy may be impacted by cancer-related physiological changes. The purpose of this study was to examine the agreement among accessible body composition method with criterion methods for measures of whole-body FFM measurements and, when possible, muscle mass for the classification of low muscle in patients with cancer. METHODS: Patients with colorectal cancer were recruited to complete measures of whole-body DXA, air displacement plethysmography (ADP), and bioelectrical impedance analysis (BIA). These measures were used alone, or in combination to construct the criterion multicompartment (4C) mode for estimating FFM. Patients also underwent abdominal CT scans as part of routine clinical assessment. Agreement of each method with 4C model was analyzed using mean constant error (CE = criterion - alternative), linear regression including root mean square error (RMSE), Bland-Altman limits of agreement (LoA) and mean percentage difference (MPD). Additionally, appendicular lean soft tissue index (ALSTI) measured by DXA and predicted by CT were compared for the absolute agreement, while the ALSTI values and skeletal muscle index by CT were assessed for agreement on the classification of low muscle mass. RESULTS: Forty-five patients received all measures for the 4C model and 25 had measures within proximity of clinical CT measures. Compared to 4C, DXA outperformed ADP and BIA by showing the strongest overall agreement (CE = 1.96 kg, RMSE = 2.45 kg, MPD = 98.15 ± 2.38%), supporting its use for body composition assessment in patients with cancer. However, CT cutoffs for skeletal muscle index or CT-estimated ALSTI were lower than DXA ALSTI (average 1.0 ± 1.2 kg/m2) with 24.0% to 32.0% of patients having a different low muscle classification by CT when compared to DXA. CONCLUSIONS: Despite discrepancies between clinical body composition assessment and the criterion multicompartment model, DXA demonstrates the strongest agreement with 4C. Disagreement between DXA and CT for low muscle mass classification prompts further evaluation of the measures and cutoffs used with each technique. Multicompartment models may enhance our understanding of body composition variations at the individual patient level and improve the applicability of clinically accessible technologies for classification and monitoring change over time.


Asunto(s)
Absorciometría de Fotón , Composición Corporal , Neoplasias Colorrectales , Impedancia Eléctrica , Músculo Esquelético , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Absorciometría de Fotón/métodos , Anciano , Tomografía Computarizada por Rayos X/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiopatología , Pletismografía/métodos , Adulto
7.
Nutrients ; 16(12)2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38931164

RESUMEN

The quality-initiative analysis of weekly duplicate PEAPOD® body composition measurements was conducted from clinical practice (January to September 2021) on preterm and term infants without respiratory support. Statistical analysis, including regression analysis, Bland-Altman plots and cv-root-mean-square tests, was performed. A total of 188 duplicate (376 individual) measurements were collected from 119 infants (88 preterm, 31 term). The median absolute difference between duplicates was 31.5 g for fat-free mass (FFM). Linear correlation analysis showed R2 = 0.97 for FFM. The absolute differences in FFM and fat mass did not significantly correlate with increasing age. The %FFM differed (p = 0.02) across body weight groups of 1 kg < BW ≤ 2 kg (1.8%; IQR: 0.8, 3.6) and BW > 3 kg (0.9%; IQR: 0.3, 2.1). The median absolute differences were 1 g (IQR: 0.4, 3.1) for body weight and 5.6 mL (IQR: 2.1, 11.8) for body volume. Body volume estimation is charged with a constant absolute error, which is the main factor for differences between repeated body composition assessments. This error becomes more prominent in infants with lower body weights. Nevertheless, reproducibility of weekly PEAPOD testing is sufficient to monitor body compartment changes, offering a foundation for nutritional decisions in both preterm and term infants.


Asunto(s)
Composición Corporal , Recien Nacido Prematuro , Pletismografía , Humanos , Recién Nacido , Reproducibilidad de los Resultados , Masculino , Femenino , Pletismografía/métodos , Lactante , Peso Corporal
8.
J Bodyw Mov Ther ; 39: 531-535, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38876680

RESUMEN

Body composition is a fundamental component of physical fitness related to the performance of Sitting volleyball (SV) players. Also, establishing the best method for evaluating the body composition of these para-athletes would be highly necessary for this field. The purpose of this study was (1) to describe the body composition of male and female highly trained SV players, (2) to compare the values obtained from this population by two different methods and (3) to establish validity on one of these methods. Thirteen Brazilian SV national team players (five males and eight females) participated in this study. The air-displacement plethysmography (ADP) method as the criterion assessment and the skinfolds (SF) method were conducted for each player. Results showed that there were no significant differences between the values of all players, which ADP and SF measured for body fat percentage (BF%) and body density (BD) (p > 0.05). We found significantly different values between male and female players for BF% by SF (p = 0.04) and BD by SF (p = 0.04). A high degree of reliability was found between ADP and SF measures for BF% and BD. There were statistically significant positive correlations between BF% and BD in all values for both methods (p < 0.01). This pilot study suggests that considering the magnitude of space, expense, and other limitations related to the ADP method against the SF method, we recommend using the SF method, which is a valid, viable and reliable method for measuring body composition in elite SV players.


Asunto(s)
Composición Corporal , Pletismografía , Grosor de los Pliegues Cutáneos , Voleibol , Humanos , Masculino , Femenino , Voleibol/fisiología , Proyectos Piloto , Composición Corporal/fisiología , Adulto Joven , Pletismografía/métodos , Reproducibilidad de los Resultados , Adulto , Sedestación
9.
Biomed Phys Eng Express ; 10(5)2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-38941984

RESUMEN

The magneto-plethysmograph method is a combination of magnetic field and sensors used to detect changes in blood flow pulsation. However, to detect the magnetic properties of blood related to hemoglobin concentration, physical modeling and simulation are required. This approach involves designing simulations using magnetic field equations and magnetic susceptibility, where a permanent magnet is placed on the surface of blood vessels, and sensors based on giant magnetoresistance are placed at a distance r. The design originates from a simple approach involving the magnetization and detection of Fe atoms in hemoglobin. Parameters involved include the magnetic susceptibility of oxyhemoglobin and deoxyhemoglobin, with an external magnetic field exceeding 1 Tesla. From the physical modeling and simulation, graphs are obtained depicting the influence of hemoglobin concentration on the number of Fe atoms and its magnetization. This enables the design of non-invasive hemoglobin measurement sensor devices. The uniqueness of this simple physical model and simulation lies in its ability to produce specially designed device models for measuring hemoglobin concentration. This differs from other research focusing on blood flow pulse measurements; the results of this study provide new insights into the benefits of simple physics equations that can be developed for medical diagnostic research and device development.


Asunto(s)
Simulación por Computador , Hemoglobinas , Pletismografía , Hemoglobinas/análisis , Humanos , Pletismografía/métodos , Campos Magnéticos , Diseño de Equipo , Oxihemoglobinas/análisis
10.
Sensors (Basel) ; 24(9)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38733031

RESUMEN

This study aimed to propose a portable and intelligent rehabilitation evaluation system for digital stroke-patient rehabilitation assessment. Specifically, the study designed and developed a fusion device capable of emitting red, green, and infrared lights simultaneously for photoplethysmography (PPG) acquisition. Leveraging the different penetration depths and tissue reflection characteristics of these light wavelengths, the device can provide richer and more comprehensive physiological information. Furthermore, a Multi-Channel Convolutional Neural Network-Long Short-Term Memory-Attention (MCNN-LSTM-Attention) evaluation model was developed. This model, constructed based on multiple convolutional channels, facilitates the feature extraction and fusion of collected multi-modality data. Additionally, it incorporated an attention mechanism module capable of dynamically adjusting the importance weights of input information, thereby enhancing the accuracy of rehabilitation assessment. To validate the effectiveness of the proposed system, sixteen volunteers were recruited for clinical data collection and validation, comprising eight stroke patients and eight healthy subjects. Experimental results demonstrated the system's promising performance metrics (accuracy: 0.9125, precision: 0.8980, recall: 0.8970, F1 score: 0.8949, and loss function: 0.1261). This rehabilitation evaluation system holds the potential for stroke diagnosis and identification, laying a solid foundation for wearable-based stroke risk assessment and stroke rehabilitation assistance.


Asunto(s)
Redes Neurales de la Computación , Fotopletismografía , Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular , Humanos , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Fotopletismografía/métodos , Fotopletismografía/instrumentación , Accidente Cerebrovascular/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Adulto , Pletismografía/métodos , Pletismografía/instrumentación , Diseño de Equipo , Dispositivos Electrónicos Vestibles , Algoritmos
11.
Turk J Med Sci ; 54(1): 115-120, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38812625

RESUMEN

Background/aim: We aimed to search the relationship between the preoperative PVI (pleth variability index) and intraoperative respiratory parameters to reveal whether PVI can be used as a prediction tool in bariatric surgery. Materials and methods: Forty patients undergoing bariatric surgery were included. Noninvasive pleth variability index measured via finger probe before induction of general anesthesia. Following intubation each patient was ventilated in controlled mode. Intraoperative blood pressure, peak airway pressure, end-tidal CO2, SpO2, PEEP, and FiO2 were recorded every 5 min for the first 10 min and then every 10 min until extubation. Steroid and bronchodilator requirements were recorded. Results: The systolic pressure-PVI, oxygen saturation-PVI relationship was statistically significant (p = 0.03, p = 0.013). A relationship was found between pleth variability index and peak airway pressure (p = 0.002). No correlation was detected between end-tidal CO2 and pleth variability index. The relationship between steroid, bronchodilator use, and PVI was significant (p = 0.05, p = 0.01). A positive correlation between PEEP and PVI was detected at varying time points. A positive correlation was found between FiO2-PVI. Conclusion: A relationship was found between PVI and intraoperative peak airway pressures, oxygen saturation, PEEP, bronchodilatator, and steroid usage. This result may be inspiring to conduct larger studies addressing the issue of predicting intraoperative respiratory problems in bariatric surgeries.


Asunto(s)
Cirugía Bariátrica , Humanos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Complicaciones Intraoperatorias/diagnóstico , Pletismografía/métodos
12.
Pediatr Allergy Immunol Pulmonol ; 37(1): 7-12, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38484265

RESUMEN

Background: Structured light plethysmography (SLP) is a novel light-based method that captures chest wall movements to evaluate tidal breathing. Methods: Thirty-two children who underwent lung surgery were enrolled. Their clinical history was collected along with spirometry and SLP. Results: Median age of surgery was 9 months (interquartile range 4-30). Most frequent diagnosis was congenital pulmonary airway malformation (14/32), then pulmonary sequestration (9/32), tumor (5/32), and bronchogenic cyst (4/32). The most frequent surgical approach was lobectomy (59%), segmentectomy (38%), and complete resection (3%). More than 80% had surgery when younger than 3 years of age. Eight patients had short-term complications (pleural effusion was the most frequent), while long-term effects were reported in 15 patients (19% recurrent cough, 13% thoracic deformities, 13% airway infections, 9% wheezing, 6% reduced exercise tolerance, and 3% columnar deformities). Spirometry was normal in 9/22 patients. Nine patients had a restrictive pattern, while 4 showed a mild bronco-reactivity. Ten patients did not perform spirometry because of young age. SLP revealed the presence of obstructive pattern in 10% of patients (IE50 > 1.88) and showed a significant difference between the two hemithorax in 29% of patients. Discussion: SLP may be a new method to evaluate lung function, without collaboration and radiation exposure, in children who underwent lung resection, also in preschool age.


Asunto(s)
Pletismografía , Procedimientos Quirúrgicos Pulmonares , Niño , Preescolar , Humanos , Lactante , Pletismografía/métodos , Respiración , Espirometría/métodos , Pulmón/cirugía
13.
J Neurodev Disord ; 16(1): 6, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38429713

RESUMEN

BACKGROUND: Angelman syndrome (AS) is a rare neurodevelopmental disorder characterized by severe intellectual disability, little to no expressive speech, visual and motor problems, emotional/behavioral challenges, and a tendency towards hyperphagia and weight gain. The characteristics of AS make it difficult to measure these children's functioning with standard clinical tests. Feasible outcome measures are needed to measure current functioning and change over time, in clinical practice and clinical trials. AIM: Our first aim is to assess the feasibility of several functional tests. We target domains of neurocognitive functioning and physical growth using the following measurement methods: eye-tracking, functional Near-Infrared Spectroscopy (fNIRS), indirect calorimetry, bio-impedance analysis (BIA), and BOD POD (air-displacement plethysmography). Our second aim is to explore the results of the above measures, in order to better understand the AS phenotype. METHODS: The study sample consisted of 28 children with AS aged 2-18 years. We defined an outcome measure as feasible when (1) at least 70% of participants successfully finished the measurement and (2) at least 60% of those participants had acceptable data quality. Adaptations to the test procedure and reasons for early termination were noted. Parents rated acceptability and importance and were invited to make recommendations to increase feasibility. The results of the measures were explored. RESULTS: Outcome measures obtained with eye-tracking and BOD POD met the definition of feasibility, while fNIRS, indirect calorimetry, and BIA did not. The most important reasons for early termination of measurements were showing signs of protest, inability to sit still and poor/no calibration (eye-tracking specific). Post-calibration was often applied to obtain valid eye-tracking results. Parents rated the BOD POD als most acceptable and fNIRS as least acceptable for their child. All outcome measures were rated to be important. Exploratory results indicated longer reaction times to high salient visual stimuli (eye-tracking) as well as high body fat percentage (BOD POD). CONCLUSIONS: Eye-tracking and BOD POD are feasible measurement methods for children with AS. Eye-tracking was successfully used to assess visual orienting functions in the current study and (with some practical adaptations) can potentially be used to assess other outcomes as well. BOD POD was successfully used to examine body composition. TRIAL REGISTRATION: Registered d.d. 23-04-2020 under number 'NL8550' in the Dutch Trial Register: https://onderzoekmetmensen.nl/en/trial/23075.


Asunto(s)
Síndrome de Angelman , Niño , Humanos , Síndrome de Angelman/complicaciones , Síndrome de Angelman/diagnóstico , Reproducibilidad de los Resultados , Composición Corporal , Pletismografía/métodos , Impedancia Eléctrica
14.
IEEE J Biomed Health Inform ; 28(5): 2699-2712, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38442050

RESUMEN

OBJECTIVE: To develop a cuffless method for estimating blood pressure (BP) from fingertip strain plethysmography (SPG) recordings. METHODS: A custom-built micro-electromechanical systems (MEMS) strain sensor is employed to record heartbeat-induced vibrations at the fingertip. An XGboost regressor is then trained to relate SPG recordings to beat-to-beat systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP) values. For this purpose, each SPG segment in this setup is represented by a feature vector consisting of cardiac time interval, amplitude features, statistical properties, and demographic information of the subjects. In addition, a novel concept, coined geometric features, are introduced and incorporated into the feature space to further encode the dynamics in SPG recordings. The performance of the regressor is assessed on 32 healthy subjects through 5-fold cross-validation (5-CV) and leave-subject-out cross validation (LSOCV). RESULTS: Mean absolute errors (MAEs) of 3.88 mmHg and 5.45 mmHg were achieved for DBP and SBP estimations, respectively, in the 5-CV setting. LSOCV yielded MAEs of 8.16 mmHg for DBP and 16.81 mmHg for SBP. Through feature importance analysis, 3 geometric and 26 integral-related features introduced in this work were identified as primary contributors to BP estimation. The method exhibited robustness against variations in blood pressure level (normal to critical) and body mass index (underweight to obese), with MAE ranges of [1.28, 4.28] mmHg and [2.64, 7.52] mmHg, respectively. CONCLUSION: The findings suggest high potential for SPG-based BP estimation at the fingertip. SIGNIFICANCE: This study presents a fundamental step towards the augmentation of optical sensors that are susceptible to dark skin tones.


Asunto(s)
Determinación de la Presión Sanguínea , Presión Sanguínea , Dedos , Pletismografía , Procesamiento de Señales Asistido por Computador , Humanos , Determinación de la Presión Sanguínea/métodos , Dedos/fisiología , Dedos/irrigación sanguínea , Adulto , Pletismografía/métodos , Masculino , Presión Sanguínea/fisiología , Femenino , Sistemas Microelectromecánicos , Adulto Joven
15.
Am J Vet Res ; 85(6)2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38503051

RESUMEN

OBJECTIVE: To compare the accuracy of doppler ultrasound (DOP) and pulse oximeter plethysmography (POP) in the measurement of systolic arterial pressure (SAP) to invasive blood pressure (IBP) in anesthetized dogs. ANIMALS: 40 client-owned healthy dogs > 10 kg. METHODS: Dogs were anesthetized for surgical procedures in dorsal recumbency. Invasive blood pressure was measured from a dorsal pedal artery. DOP and POP device probes were placed over the median caudal artery with a flow-occluding cuff for noninvasive blood pressure measurement. Systolic arterial pressure measured by DOP, loss of pulse oximeter plethysmograph (POPL), and return of pulse oximeter plethysmograph (POPR) were compared to SAP measured by IBP. A linear mixed model was used to determine correlation. Bland-Altman analyses were performed to determine bias, SD, and limits of agreement. The accuracy of DOP and POP was compared to IBP across different tensive states. RESULTS: Conditional R2 values for DOP, POPL, and POPR versus IBP were 0.92, 0.85, and 0.87, respectively (all P < .001). The biases for DOP, POPL, and POPR compared to IBP were +7.6 ± 13.1, +3.9 ± 14.4, and +8.6 ± 15.2 mm Hg (bias ± SD), respectively. Limits of agreement (lower, upper) were (-18.1, +33.3), (-24.3, +32.1), and (-21.2, +38.4) mm Hg for DOP, POPL, and POPR, respectively. DOP and POP overestimated SAP during hypotension (SAP < 90 mm Hg), DOP to a lesser magnitude. CLINICAL RELEVANCE: DOP measured from the median caudal artery may be acceptable for SAP measurement in dorsally recumbent, healthy anesthetized dogs > 10 kg. POP was determined an unacceptable method.


Asunto(s)
Anestesia , Determinación de la Presión Sanguínea , Oximetría , Pletismografía , Ultrasonografía Doppler , Animales , Perros , Oximetría/veterinaria , Ultrasonografía Doppler/veterinaria , Pletismografía/veterinaria , Pletismografía/métodos , Masculino , Determinación de la Presión Sanguínea/veterinaria , Determinación de la Presión Sanguínea/métodos , Anestesia/veterinaria , Femenino , Presión Arterial , Arterias
16.
Clin Transl Sci ; 17(2): e13735, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38344891

RESUMEN

Buloxibutid (also known as C21) is a potent and selective angiotensin II type 2 receptor (AT2R) agonist, in development for oral treatment of fibrotic lung disease. This phase I, open-label, pharmacodynamic study investigated vascular effects of buloxibutid in five healthy male volunteers. Subjects were administered intra-arterial infusions of buloxibutid for 5 min in ascending doses of 3, 10, 30, 100, and 200 µg/min, infused sequentially in the forearm. Infusions of sodium nitroprusside (SNP) solution in doses of 0.8-3.2 µg/min were administered as a positive control. Forearm blood flow (FBF) was measured by venous occlusion plethysmography. Safety and tolerability of intra-arterial administrations of buloxibutid were evaluated. Following infusion of buloxibutid in doses of 3-200 µg/min, the range of increase in FBF was 27.8%, 17.2%, 37.0%, 28.5%, and 60.5%, compared to the respective baseline. The largest increase was observed in the highest dose group. Infusions of SNP as a positive control, increased FBF 230-320% compared to baseline. Three adverse events (AEs) of mild intensity, not related to buloxibutid or SNP, were reported for two subjects. Two of these AEs were related to study procedures. There were no clinically relevant changes in arterial blood pressure during the study period. Intra-arterial infusion of buloxibutid in low, ascending doses increased FBF, indicating that buloxibutid may be effective in conditions associated with endothelial dysfunction. Venous occlusion plethysmography was found to be a useful method to explore pharmacodynamic vascular effects of novel AT2R agonists, while avoiding systemic adverse effects.


Asunto(s)
Pletismografía , Receptor de Angiotensina Tipo 2 , Humanos , Masculino , Nitroprusiato/efectos adversos , Pletismografía/métodos , Antebrazo/irrigación sanguínea , Flujo Sanguíneo Regional , Vasodilatación
17.
Paediatr Anaesth ; 34(6): 559-567, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38348932

RESUMEN

BACKGROUND: Intraoperative fluid therapy maintains normovolemia, normal tissue perfusion, normal metabolic function, normal electrolytes, and acid-base status. Plethysmographic variability index has been shown to predict fluid responsiveness but its role in guiding intraoperative fluid therapy is still elusive. AIMS: The aim of the present study was to compare intraoperative goal-directed fluid therapy based on plethysmographic variability index with liberal fluid therapy in term neonates undergoing abdominal surgeries. METHODS: A prospective randomized controlled study was conducted in a tertiary care centre, over a period of 18 months. A total of 30 neonates completed the study out of 132 neonates screened. Neonates with tracheoesophageal fistula, congenital diaphragmatic hernia, congenital heart disease, respiratory disorders, creatinine clearance <90 mL/min and who were hemodynamically unstable were excluded. Neonates were randomized to goal-directed fluid therapy group where the plethysmographic variability index was targeted at <18 or liberal fluid therapy group. Primary outcome was comparison of total amount of fluid infused intraoperatively in both the groups. Secondary outcomes included intraoperative and postoperative arterial blood gas parameters, biochemical parameters, use of vasopressors, number of fluid boluses, complications and duration of hospital stay. RESULTS: There was no significant difference in total intraoperative fluid infused [90 (84-117.5 mL) in goal-directed fluid therapy and 105 (85.5-144.5 mL) in liberal fluid therapy group (p = .406)], median difference (95% CI) -15 (-49.1 to 19.1). There was a decrease in serum lactate levels in both groups from preoperative to postoperative 24 h. The amount of fluid infused before dopamine administration was significantly higher in liberal fluid therapy group (58 [50.25-65 mL]) compared to goal-directed fluid therapy group (36 [22-44 mL], p = .008), median difference (95% CI) -22 (-46 to 2). In postoperative period, the total amount of fluid intake over 24 h was comparable in two groups (222 [204-253 mL] in goal-directed fluid therapy group and 224 [179.5-289.5 mL] in liberal fluid therapy group, p = .917) median difference (95% CI) cutoff -2 (-65.3 to 61.2). CONCLUSION: Intraoperative plethysmographic variability index-guided goal-directed fluid therapy was comparable to liberal fluid therapy in terms of total volume of fluid infused in neonates during perioperative period. More randomized controlled trials with higher sample size are required. TRIAL REGISTRATION: Central Trial Registry of India (CTRI/2020/02/023561).


Asunto(s)
Abdomen , Fluidoterapia , Pletismografía , Humanos , Fluidoterapia/métodos , Recién Nacido , Estudios Prospectivos , Masculino , Femenino , Pletismografía/métodos , Abdomen/cirugía , Análisis de los Gases de la Sangre/métodos , Cuidados Intraoperatorios/métodos , Resultado del Tratamiento
18.
Artículo en Inglés | MEDLINE | ID: mdl-38265049

RESUMEN

AIM: To determine the validity of bioelectrical impedance analysis (BIA) in quantifying fat-free mass (FFM) compared to air-displacement plethysmography (ADP) in patients with a motor neurone disease (MND). METHODS: FFM of 140 patients diagnosed with MND was determined by ADP using the BodPod (i.e. the gold standard), and by BIA using the whole-body Bodystat. FFM values were translated to predicted resting energy expenditure (REE); the actual REE was measured using indirect calorimetry, resulting in a metabolic index. Validity of the BIA compared to the ADP was assessed using Bland-Altman analysis and Pearson's r. To assess the clinical relevance of differences, we evaluated changes in metabolic index and in individualized protein demand. RESULTS: Despite the high correlation between ADP and BIA (r = 0.93), averaged across patients, the assessed mean fat-free mass was 51.7 kg (± 0.9) using ADP and 54.2 kg (± 1.0) using BIA. Hence, BIA overestimated fat-free mass by 2.5 kg (95% CI 1.8-3.2, p < 0.001). Clinically, an increased metabolic index would be more often underdiagnosed in patients with MND using BIA (31.4% according to BIA versus 44.2% according to ADP, p = 0.048). A clinically relevant overestimation of ≥ 15 g in protein demand was observed for 4 (2.9%) patients using BIA. CONCLUSIONS: BIA systematically overestimates FFM in patients with MND. Although the differences are limited with ADP, underscoring the utility of BIA for research, overestimation of fat-free mass may have consequences for clinical decision-making, especially when interest lies in determining the metabolic index.


Asunto(s)
Esclerosis Amiotrófica Lateral , Enfermedad de la Neurona Motora , Humanos , Composición Corporal , Estudios Transversales , Pletismografía/métodos , Impedancia Eléctrica , Reproducibilidad de los Resultados , Enfermedad de la Neurona Motora/diagnóstico
19.
Respir Med Res ; 85: 101082, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38280281

RESUMEN

BACKGROUND: Dyspnea is a complex symptom of chronic obstructive pulmonary disease (COPD) which is not strongly correlated with lung function measures. Long-acting bronchodilators (LAB) may reduce this dyspnea, but some patients report persistent chronic dyspnea despite this treatment. This study aims to assess residual reversibility and clinical response after short-acting bronchodilator (SAB) in COPD patients already treated by LAB and reporting persistent dyspnea. METHODS: COPD patients with a persistent dyspnea (modified Medical Research Council scale (mMRC) ≥1) despite current stable treatment with at least one LAB were included. Spirometry, plethysmography and impulse oscillometry (IOS) were performed at peak effect of their LAB and repeat 45 min after the intake of two SAB (400 µg of salbutamol and 80 µg of ipratropium). Dyspnea improvement was assessed at 45 min after SAB through a comparative two-sided VAS (-100 mm for maximal improvement; +100 mm for maximal degradation). RESULTS: Twenty-two COPD patients were analyzed, mainly men (59.1 %) with a mean age of 60.6 years and a median FEV1 of 54 % of predicted values. Fifty percent of patients reported a severe basal dyspnea (mMRC ≥2). After SAB, spirometric and plethysmographic measurements were statistically improved. For IOS measurement, reactance at 5 Hz (X5) and area of reactance (AX) were also improved. Fifty percent of patients reported a clinically relevant improvement of their resting dyspnea. However, no correlation was found between dyspnea improvement and functional measures. CONCLUSIONS: Fifty percent of COPD patients regularly treated with one or two LAB still report a relevant improvement of resting dyspnea after the adjunctive intake of double short-acting bronchodilators. Physiological mechanisms associated with this improvement remain to be determined. CLINICAL TRIAL REGISTRATION: NCT02928744.


Asunto(s)
Albuterol , Broncodilatadores , Disnea , Enfermedad Pulmonar Obstructiva Crónica , Espirometría , Humanos , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Broncodilatadores/administración & dosificación , Broncodilatadores/uso terapéutico , Masculino , Femenino , Persona de Mediana Edad , Anciano , Disnea/tratamiento farmacológico , Disnea/etiología , Espirometría/métodos , Albuterol/administración & dosificación , Albuterol/uso terapéutico , Oscilometría/métodos , Resultado del Tratamiento , Volumen Espiratorio Forzado/efectos de los fármacos , Pletismografía/métodos , Ipratropio/administración & dosificación , Ipratropio/uso terapéutico
20.
Sensors (Basel) ; 23(24)2023 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-38139582

RESUMEN

Respiratory rate monitoring is fundamental in clinical settings, and the accuracy of measurement methods is critical. This study aimed to develop and validate methods for assessing respiratory rate and the duration leof respiratory cycle phases in different body positions using optoelectronic plethysmography (OEP) based on a motion capture video system. Two analysis methods, the summation method and the triangle method were developed. The study focused on determining the optimal number of markers while achieving accuracy in respiratory parameter measurements. The results showed that most analysis methods showed a difference of ≤0.5 breaths per minute, with R2 ≥ 0.94 (p < 0.001) compared to spirometry. The best OEP methods for respiratory rate were the abdominal triangles and the sum of abdominal markers in all body positions. The study explored inspiratory and expiratory durations. The research found that 5-9 markers were sufficient to accurately determine respiratory time components in all body positions, reducing the marker requirements compared to previous studies. This interchangeability of OEP methods with standard spirometry demonstrates the potential of non-invasive methods for the simultaneous assessment of body segment movements, center of pressure dynamics, and respiratory movements. Future research is required to improve the clinical applicability of these methods.


Asunto(s)
Captura de Movimiento , Frecuencia Respiratoria , Respiración , Pletismografía/métodos , Espirometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA