Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.432
Filtrar
1.
Anal Chem ; 96(28): 11172-11180, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38946102

RESUMEN

Improving separation efficiency in capillary electrophoresis (CE) requires systematic study of the influence of the electric field (or solute linear velocity) on plate height for a better understanding of the critical parameters controlling peak broadening. Even for poly(diallyldimethylammonium chloride) (PDADMAC)/poly(sodium styrenesulfonate) (PSS) successive multiple ionic-polymer layer (SMIL) coatings, which lead to efficient and reproducible separations of proteins, plate height increases with migration velocity, limiting the use of high electric fields in CE. Solute adsorption onto the capillary wall was generally considered as the main source of peak dispersion, explaining this plate height increase. However, experiments done with Taylor dispersion analysis and CE in the same conditions indicate that other phenomena may come into play. Protein adsorption with slow kinetics and few adsorption sites was established as a source of peak broadening for specific proteins. Surface charge inhomogeneity was also identified as a contribution to plate height due to local electroosmotic fluctuations. A model was proposed and applied to partial PDADMAC/poly(ethylene oxide) capillary coatings as well as PDADMAC/PSS SMIL coatings. Atomic force microscopy with topography and recognition imaging enabled the determination of roughness and charge distribution of the PDADMAC/PSS SMIL surface.


Asunto(s)
Electroósmosis , Electroforesis Capilar , Polietilenos , Electroforesis Capilar/métodos , Adsorción , Polietilenos/química , Proteínas/aislamiento & purificación , Proteínas/química , Proteínas/análisis , Compuestos de Amonio Cuaternario/química , Animales , Propiedades de Superficie
2.
BMC Oral Health ; 24(1): 696, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879492

RESUMEN

BACKGROUND: An optimum restoration for reconstructing endodontically treated teeth should provide excellent marginal adaptation, high fracture resistance as well as maximum tooth structure conservation. The purpose of this study was to evaluate the marginal adaptation and fatigue resistance of different coronal restorations in endodontically treated premolars. METHODS: Thirty sound maxillary first premolars were endodontically treated and received MOD cavities. Teeth were randomly allocated into three groups (n = 10) according to the type of coronal restoration: Group R: polyethylene fibers (ribbond), fibers-reinforced composite (everX posterior) and final layer of nano-hybrid composite. Group O: indirect lithium disilicate overlay and Group C: fiber-post, resin composite restoration, and lithium disilicate crown. Marginal gap assessment was performed before and after thermocycling (5000 cycles) using stereomicroscope. Samples were subjected to stepwise-stress loading starting at 200 N, and increased by 100 N in each step until failure occurred. Statistical analysis was done by One-way ANOVA followed Tukey`s Post Hoc test for multiple comparison. Paired t test was used to compare the marginal adaptation before and after thermocycling. Survival probability was evaluated by Life table survival analysis. Failure mode analysis was performed with Chi-square test. RESULTS: Marginal gap was significantly the lowest in group R (37.49 ± 5.05) and (42.68 ± 2.38), while being the highest in group C (59.78 ± 5.67) and (71.52 ± 5.18) in before and after thermocycling respectively (P < 0.0001). Fatigue resistance was the highest for group O (1310.8 ± 196.7), and the lowest for group R (905.4 ± 170.51) with a significant difference between groups (P < 0.0001). Crown group had the highest percentage (80%) of catastrophic failure, while, overlay group exhibited the lowest (20%). CONCLUSIONS: Direct restoration without cuspal coverage using ribbon fibers with short FRC provided better marginal adaptation than indirect overlays and crowns, but fatigue resistance wasn't significantly improved. Adhesive ceramic overlays showed the best fatigue performance and the least catastrophic failure rate compared to both direct fiber-reinforced composite and indirect ceramic full coverage restorations. CLINICAL SIGNIFICANCE: Indirect adhesive overlays are a suitable, more conservative restorative option for endodontically treated teeth than full coverage restorations, especially when tooth structure is severely compromised.


Asunto(s)
Diente Premolar , Resinas Compuestas , Coronas , Adaptación Marginal Dental , Técnica de Perno Muñón , Diente no Vital , Humanos , Resinas Compuestas/química , Técnicas In Vitro , Restauración Dental Permanente/métodos , Porcelana Dental/química , Análisis del Estrés Dental , Polietilenos/química , Fracaso de la Restauración Dental , Ensayo de Materiales , Materiales Dentales/química
3.
J Oleo Sci ; 73(7): 953-961, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38945924

RESUMEN

Handwashing represents an important personal hygiene measure for preventing infection. Herein, we report the persistence of antibacterial and antiviral effects after handwashing with fatty acid salt-based hand soap. To this end, we developed a new in vitro test method to measure persistence, utilizing coacervation formed by anionic surfactants and cationic polymers to retain highly effective soap components against each bacterium and virus on the skin. Coacervation with fatty acid salts and poly diallyldimethylammonium chloride (PDADMAC) as a cationic polymer allowed the persistence of antibacterial and antiviral effects against E. coli, S. aureus, and influenza virus even 4 h after handwashing. Furthermore, we confirmed an increase in the number of residual components effective against each bacterium and virus on the skin. In summary, the current findings describe an effective approach for enhancing the protective effects of handwashing.


Asunto(s)
Antibacterianos , Antivirales , Escherichia coli , Desinfección de las Manos , Polietilenos , Compuestos de Amonio Cuaternario , Piel , Jabones , Staphylococcus aureus , Tensoactivos , Jabones/farmacología , Escherichia coli/efectos de los fármacos , Desinfección de las Manos/métodos , Compuestos de Amonio Cuaternario/farmacología , Antibacterianos/farmacología , Staphylococcus aureus/efectos de los fármacos , Antivirales/farmacología , Piel/efectos de los fármacos , Piel/microbiología , Tensoactivos/farmacología , Humanos , Ácidos Grasos/farmacología , Ácidos Grasos/análisis , Factores de Tiempo , Orthomyxoviridae/efectos de los fármacos
4.
Biomed Phys Eng Express ; 10(5)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38906123

RESUMEN

In this study tissue equivalency of the polymeric materials was investigated by comparing with ICRP 110 Male Adult Computational Phantom tissues. For this purpose, radiological properties of polyamide (PA), high density polyethylene (HDPE), ultra-high molecular weight polyethylene (UHMWPE), polypropylene (PP), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), polyoxymethylene (POM) and polyurethane foam (PU FOAM) were evaluated in the diagnostic energy range (15-150 keV). The radiological properties of the materials and ICRP 110 Male and Female Adult Computational Phantom tissues were calculated with Phy-X/PSD software. No major differences were seen except for sex-specific organs, and comparisons were made using an adult male phantom. To confirm the results experimentally, a chest phantom was designed with the polymeric materials. The phantom was scanned by Siemens SOMATOM Edge CT device with tube voltage of 120 kVp and Hounsfield Unit (HU) values were measured. In addition, HU values were calculated using theoretical relationships and significant agreement was obtained between measured and calculated HUs. It was determined that PA, PP, UHMWPE and HDPE were equivalent to muscle and adipose tissue, PVC and PTFE were equivalent to mineral bone, PET and POM were equivalent to spongiosa bone and PU FOAM was equivalent to lung tissue.


Asunto(s)
Fantasmas de Imagen , Polímeros , Humanos , Masculino , Polímeros/química , Femenino , Adulto , Tomografía Computarizada por Rayos X/métodos , Ensayo de Materiales , Polietilenos/química
5.
Talanta ; 277: 126433, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38901195

RESUMEN

Analysis of real objects based on surface-enhanced Raman spectroscopy (SERS) often utilizes new SERS substrates and/or complex analysis procedures, and they are optimized for only the determination of a single analyte. Moreover, analysis simplicity and selectivity are often sacrificed for maximum (sometimes unnecessary) sensitivity. Consequently, this trend limits the versatility of SERS analysis and complicates its practical implementation. Thus, we have developed a universal, but simple SERS assay suitable for the determination of structurally related antibiotics (five representatives of the sulfanilamide class) in complex objects (human urine and saliva). The assay involves only mixing of acidified analyzed solution with co-activating agent (polydiallyldimethylammonium chloride - PDDA) and SERS substrate (standard colloidal silver nanoparticles). Acidification promotes the generation of SERS spectra with maximum similarity and intensity, which is explained by the favorable enhancement of the protonated sulfanilamide moiety (a structurally similar part of the studied antibiotics) as a result of its strong electrostatic interaction with the SERS-active surface. Meanwhile, the addition of PDDA improves analysis selectivity by reducing background signal from body fluids, enabling to simplify sample pretreatment (dilution for urine; mucin removal and dilution for saliva). Therefore, the assay allows for rapid (≤10 min), precise, and accurate class-specific determination of sulfanilamides within concentration ranges suitable for non-invasive therapeutic drug monitoring in urine (40-600 µM) and saliva (10-30 µM). We also believe that thorough investigation of structurally related analytes and accompanying effects (e.g., high spectral similarity) is a promising direction to improve the understanding of SERS in general and expand its capabilities as an analytical tool.


Asunto(s)
Antibacterianos , Compuestos de Amonio Cuaternario , Saliva , Espectrometría Raman , Sulfanilamidas , Espectrometría Raman/métodos , Humanos , Antibacterianos/análisis , Antibacterianos/orina , Sulfanilamidas/química , Sulfanilamidas/análisis , Compuestos de Amonio Cuaternario/química , Saliva/química , Plata/química , Polietilenos/química , Sulfanilamida/química , Nanopartículas del Metal/química
6.
ACS Appl Mater Interfaces ; 16(23): 29805-29822, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38830200

RESUMEN

Periprosthetic osteolysis induced by the ultrahigh-molecular-weight polyethylene (UHMWPE) wear particles is a major complication associated with the sustained service of artificial joint prostheses and often necessitates revision surgery. Therefore, a smart implant with direct prevention and repair abilities is urgently developed to avoid painful revision surgery. Herein, we fabricate a phosphatidylserine- and polyethylenimine-engineered niobium carbide (Nb2C) MXenzyme-coated micro/nanostructured titanium implant (PPN@MNTi) that inhibits UHMWPE particle-induced periprosthetic osteolysis. The specific mechanism by which PPN@MNTi operates involves the bioresponsive release of nanosheets from the MNTi substrate within an osteolysis microenvironment, initiated by the cleavage of a thioketal-dopamine molecule sensitive to reactive oxygen species (ROS). Subsequently, functionalized Nb2C MXenzyme could target macrophages and escape from lysosomes, effectively scavenging intracellular ROS through its antioxidant nanozyme-mimicking activities. This further achieves the suppression of osteoclastogenesis by inhibiting NF-κB/MAPK and autophagy signaling pathways. Simultaneously, based on the synergistic effect of MXenzyme-integrated coatings and micro/nanostructured topography, the designed implant promotes the osteogenic differentiation of bone mesenchymal stem cells to regulate bone homeostasis, further achieving advanced osseointegration and alleviable periprosthetic osteolysis in vivo. This study provides a precise prevention and repair strategy of periprosthetic osteolysis, offering a paradigm for the development of smart orthopedic implants.


Asunto(s)
Niobio , Osteogénesis , Osteólisis , Osteogénesis/efectos de los fármacos , Osteólisis/patología , Osteólisis/prevención & control , Osteólisis/metabolismo , Niobio/química , Ratones , Animales , Polietilenos/química , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Titanio/química , Células RAW 264.7 , Especies Reactivas de Oxígeno/metabolismo , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/metabolismo , Osteoclastos/efectos de los fármacos , Osteoclastos/metabolismo
7.
APMIS ; 132(8): 553-563, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38741279

RESUMEN

The use of highly crosslinked ultra-high molecular weight polyethylene (XLPE) has significantly reduced the volumetric wear of acetabular liners, thereby reducing the incidence of osteolysis. However, contemporary components tend to generate smaller wear particles, which can no longer be identified using conventional histology. This technical limitation can result in imprecise diagnosis. Here, we report on two uncemented total hip arthroplasty cases (~7 years in situ) revised for periprosthetic fracture of the femur and femoral loosening, respectively. Both liners exhibited prominent wear. The retrieved pseudocapsular tissue exhibited a strong macrophage infiltration without microscopically identifiable polyethylene particles. Yet, using Fourier-transform infrared micro-spectroscopic imaging (FTIR-I), we demonstrated the prominent intracellular accumulation of polyethylene debris in both cases. This study shows that particle induced osteolysis can still occur with XLPE liners, even under 10 years in situ. Furthermore, we demonstrate the difficulty of determining the presence of polyethylene debris within periprosthetic tissue. Considering the potentially increased bioactivity of finer particles from XLPE compared to conventional liners, an accurate detection method is required, and new histopathological hallmarks of particle induced osteolysis are needed. FTIR-I is a great tool to that end and can help the accurate determination of foreign body tissue responses.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Falla de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Prótesis de Cadera/efectos adversos , Femenino , Polietilenos/química , Osteólisis/etiología , Osteólisis/patología , Osteólisis/diagnóstico , Anciano , Masculino , Reoperación , Polietileno/química , Polietileno/efectos adversos , Persona de Mediana Edad
8.
Talanta ; 276: 126290, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38805755

RESUMEN

A very sensitive electrochemical biosensor, with haemoglobin (Hb) as its basis, has been created to quantify hydrogen peroxide (H2O2), an essential marker in environmental monitoring, food safety, and medical diagnosis. The sensor uses a simple, eco-friendly preparation method. Hb was immobilised on manganese dioxide nanostructure/gold nanoparticles/poly-diallydimethylammonium chloride-functionalised multiwalled carbon nanotubes (PDDA-MWCNT/AuNP/MnO2), characterised using various techniques: amperometry, voltammetry, X-ray diffraction (XRD), and transmission electron microscopy (TEM). Nafion was used as a binder membrane to preserve the biological and electrochemical properties of the protein on the modified electrode. In comparison to earlier research, the novel biosensor had a lower detection limit (1.83 µM) and a limit of quantification (6.11 µM) (S/N = 3) for H2O2. It also exhibited notable reproducibility, long-term stability, and repeatability. It was effectively used to measure the amount of H2O2 in cow milk and orange juice, yielding recoveries in the order of 98.90-99.53 % with RSDs less than 5.0 %, which makes it a promising biosensor for food control.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Oro , Hemoglobinas , Peróxido de Hidrógeno , Compuestos de Manganeso , Nanopartículas del Metal , Leche , Nanotubos de Carbono , Óxidos , Compuestos de Amonio Cuaternario , Peróxido de Hidrógeno/química , Peróxido de Hidrógeno/análisis , Oro/química , Hemoglobinas/análisis , Hemoglobinas/química , Técnicas Biosensibles/métodos , Compuestos de Manganeso/química , Nanopartículas del Metal/química , Compuestos de Amonio Cuaternario/química , Nanotubos de Carbono/química , Óxidos/química , Técnicas Electroquímicas/métodos , Leche/química , Animales , Polietilenos/química , Bovinos , Jugos de Frutas y Vegetales/análisis , Límite de Detección , Electrodos
9.
Biofabrication ; 16(3)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38574552

RESUMEN

The advent of 3D bioprinting technologies in tissue engineering has unlocked the potential to fabricatein vitrotissue models, overcoming the constraints associated with the shape limitations of preformed scaffolds. However, achieving an accurate mimicry of complex tissue microenvironments, encompassing cellular and biochemical components, and orchestrating their supramolecular assembly to form hierarchical structures while maintaining control over tissue formation, is crucial for gaining deeper insights into tissue repair and regeneration. Building upon our expertise in developing competent three-dimensional tissue equivalents (e.g. skin, gut, cervix), we established a two-step bottom-up approach involving the dynamic assembly of microtissue precursors (µTPs) to generate macroscopic functional tissue composed of cell-secreted extracellular matrix (ECM). To enhance precision and scalability, we integrated extrusion-based bioprinting technology into our established paradigm to automate, control and guide the coherent assembly ofµTPs into predefined shapes. Compared to cell-aggregated bioink, ourµTPs represent a functional unit where cells are embedded in their specific ECM.µTPs were derived from human dermal fibroblasts dynamically seeded onto gelatin-based microbeads. After 9 days,µTPs were suspended (50% v/v) in Pluronic-F127 (30% w/v) (µTP:P30), and the obtained formulation was loaded as bioink into the syringe of the Dr.INVIVO-4D6 extrusion based bioprinter.µTP:P30 bioink showed shear-thinning behavior and temperature-dependent viscosity (gel atT> 30 °C), ensuringµTPs homogenous dispersion within the gel and optimal printability. The bioprinting involved extruding several geometries (line, circle, and square) into Pluronic-F127 (40% w/v) (P40) support bath, leveraging its shear-recovery property. P40 effectively held the bioink throughout and after the bioprinting procedure, untilµTPs fused into a continuous connective tissue.µTPs fusion dynamics was studied over 8 days of culture, while the resulting endogenous construct underwent 28 days culture. Histological, immunofluorescence analysis, and second harmonic generation reconstruction revealed an increase in endogenous collagen and fibronectin production within the bioprinted construct, closely resembling the composition of the native connective tissues.


Asunto(s)
Bioimpresión , Polietilenos , Polipropilenos , Andamios del Tejido , Humanos , Andamios del Tejido/química , Bioimpresión/métodos , Poloxámero , Uridina Trifosfato , Ingeniería de Tejidos/métodos , Impresión Tridimensional
10.
Mol Med ; 30(1): 52, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38641575

RESUMEN

BACKGROUND: Skin fibrosis affects the normal function of the skin. TGF-ß1 is a key cytokine that affects organ fibrosis. The latency-associated peptide (LAP) is essential for TGF-ß1 activation. We previously constructed and prepared truncated LAP (tLAP), and confirmed that tLAP inhibited liver fibrosis by affecting TGF-ß1. SPACE peptide has both transdermal and transmembrane functions. SPACE promotes the delivery of macromolecules through the stratum corneum into the dermis. This study aimed to alleviate skin fibrosis through the delivery of tLAP by SPACE. METHODS: The SPACE-tLAP (SE-tLAP) recombinant plasmid was constructed. SE-tLAP was purified by nickel affinity chromatography. The effects of SE-tLAP on the proliferation, migration, and expression of fibrosis-related and inflammatory factors were evaluated in TGF-ß1-induced NIH-3T3 cells. F127-SE-tLAP hydrogel was constructed by using F127 as a carrier to load SE-tLAP polypeptide. The degradation, drug release, and biocompatibility of F127-SE-tLAP were evaluated. Bleomycin was used to induce skin fibrosis in mice. HE, Masson, and immunohistochemistry were used to observe the skin histological characteristics. RESULTS: SE-tLAP inhibited the proliferation, migration, and expression of fibrosis-related and inflammatory factors in NIH-3T3 cells. F127-SE-tLAP significantly reduced ECM production, collagen deposition, and fibrotic pathological changes, thereby alleviating skin fibrosis. CONCLUSION: F127-SE-tLAP could increase the transdermal delivery of LAP, reduce the production and deposition of ECM, inhibit the formation of dermal collagen fibers, and alleviate the progression of skin fibrosis. It may provide a new idea for the therapy of skin fibrosis.


Asunto(s)
Polietilenos , Polipropilenos , Enfermedades de la Piel , Factor de Crecimiento Transformador beta , Animales , Ratones , Bleomicina/efectos adversos , Colágeno/metabolismo , Fibrosis/tratamiento farmacológico , Hidrogeles/química , Hidrogeles/farmacología , Polietilenos/farmacología , Polipropilenos/farmacología , Transducción de Señal , Factor de Crecimiento Transformador beta/metabolismo , Factor de Crecimiento Transformador beta1/metabolismo , Enfermedades de la Piel/inducido químicamente , Enfermedades de la Piel/tratamiento farmacológico , Enfermedades de la Piel/metabolismo , Proteínas Smad/efectos de los fármacos , Proteínas Smad/metabolismo , Piel/efectos de los fármacos , Piel/metabolismo , Piel/patología
11.
Int J Nanomedicine ; 19: 3697-3714, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38681091

RESUMEN

Introduction: Over 75% of clinical microbiological infections are caused by bacterial biofilms that grow on wounds or implantable medical devices. This work describes the development of a new poly(diallyldimethylammonium chloride) (PDADMAC)/alginate-coated gold nanorod (GNR/Alg/PDADMAC) that effectively disintegrates the biofilms of Staphylococcus aureus (S. aureus), a prominent pathogen responsible for hospital-acquired infections. Methods: GNR was synthesised via seed-mediated growth method, and the resulting nanoparticles were coated first with Alg and then PDADMAC. FTIR, zeta potential, transmission electron microscopy, and UV-Vis spectrophotometry analysis were performed to characterise the nanoparticles. The efficacy and speed of the non-coated GNR and GNR/Alg/PDADMAC in disintegrating S. aureus-preformed biofilms, as well as their in vitro biocompatibility (L929 murine fibroblast) were then studied. Results: The synthesised GNR/Alg/PDADMAC (mean length: 55.71 ± 1.15 nm, mean width: 23.70 ± 1.13 nm, aspect ratio: 2.35) was biocompatible and potent in eradicating preformed biofilms of methicillin-resistant (MRSA) and methicillin-susceptible S. aureus (MSSA) when compared to triclosan, an antiseptic used for disinfecting S. aureus colonisation on abiotic surfaces in the hospital. The minimum biofilm eradication concentrations of GNR/Alg/PDADMAC (MBEC50 for MRSA biofilm = 0.029 nM; MBEC50 for MSSA biofilm = 0.032 nM) were significantly lower than those of triclosan (MBEC50 for MRSA biofilm = 10,784 nM; MBEC50 for MRSA biofilm 5967 nM). Moreover, GNR/Alg/PDADMAC was effective in eradicating 50% of MRSA and MSSA biofilms within 17 min when used at a low concentration (0.15 nM), similar to triclosan at a much higher concentration (50 µM). Disintegration of MRSA and MSSA biofilms was confirmed by field emission scanning electron microscopy and confocal laser scanning microscopy. Conclusion: These findings support the potential application of GNR/Alg/PDADMAC as an alternative agent to conventional antiseptics and antibiotics for the eradication of medically important MRSA and MSSA biofilms.


Asunto(s)
Alginatos , Antibacterianos , Biopelículas , Oro , Nanotubos , Polietilenos , Compuestos de Amonio Cuaternario , Staphylococcus aureus , Biopelículas/efectos de los fármacos , Oro/química , Oro/farmacología , Compuestos de Amonio Cuaternario/química , Compuestos de Amonio Cuaternario/farmacología , Alginatos/química , Alginatos/farmacología , Nanotubos/química , Animales , Ratones , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/fisiología , Antibacterianos/farmacología , Antibacterianos/química , Polietilenos/química , Polietilenos/farmacología , Infecciones Estafilocócicas/tratamiento farmacológico , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Staphylococcus aureus Resistente a Meticilina/fisiología , Línea Celular , Pruebas de Sensibilidad Microbiana , Nanopartículas del Metal/química
12.
J Orthop Surg Res ; 19(1): 259, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38659060

RESUMEN

PURPOSE: The purpose of the study was to describe a novel growth guidance system, which can avoid metal debris and reduce the sliding friction forces, and test the durability and glidability of the system by in vitro test. METHOD: Two major modifications were made to the traditional Shilla system, including the use of ultra-high molecular weight polyethylene (UHMWPE) gaskets to avoid direct contact between the screw and rod, and polishing the surface of the sliding part of the rod. We tested the durability of the system by a fatigue test, which the samples were test on the MTS system for a 10 million cycle of a constant displacement. Pre and post-testing involved weighing the UHMWPE gaskets and observing the wear conditions. The sliding ability were measured by a sliding displacement test. The maximum sliding displacement of the system was measured after a 300 cycles of dynamic compressive loads in a sinusoidal waveform. RESULTS: After the fatigue test, all the UHMWPE gaskets samples showed some of the fretting on the edge of the inner sides, but its still isolated and avoided the friction between the screws and rods. There was no production of metallic fretting around the sliding screws and rods. The average wear mass of the UHMWPE gaskets was 0.002 ± 0.001 g, less than 1.7% of the original mass. In the sliding test, the novel growth guidance system demonstrated the best sliding ability, with an average maximum sliding distance(AMSD) of 35.75 ± 5.73 mm, significantly better than the group of the traditional Shilla technique(AMSD 3.65 ± 0.46 mm, P < 0.0001). CONCLUSION: In conclusion, we modified the Shilla technique and designed a novel growth guidance system by changing the friction interface of sliding screw and rod, which may significantly reduce the metallic debris and promote spine growth. The fatigue test and sliding dislocation test demonstrated the better durability and glidability of the system. An in vivo animal experiment should be performed to further verify the system.


Asunto(s)
Ensayo de Materiales , Polietilenos , Escoliosis , Humanos , Ensayo de Materiales/métodos , Fricción , Tornillos Óseos , Técnicas In Vitro
13.
Mikrochim Acta ; 191(5): 265, 2024 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625451

RESUMEN

Sleep deprivation (SD) is highly prevalent in the modern technological world. Emerging evidence shows that sleep deprivation is associated with oxidative stress. At the organelle level, the Golgi apparatus actively participates in the stress response. In this study, to determine whether SD and Golgi apparatus stress are correlated, we rationally designed and fabricated a novel Golgi apparatus-targeted ratiometric nanoprobe called Golgi dots for O2·- detection. This probe exhibits high sensitivity and selectivity in cells and brain slices of sleep-deprived mice. Golgi dots can be readily synthesized by coprecipitation of Golgi-F127, an amphiphilic polymer F127 modified with a Golgi apparatus targeting moiety, caffeic acid (CA), the responsive unit for O2·-, and red emissive carbon nanodots (CDs), which act as the reference signal. The fluorescence emission spectrum of the developed nanoprobe showed an intense peak at 674 nm, accompanied by a shoulder peak at 485 nm. As O2·- was gradually added, the fluorescence at 485 nm continuously increased; in contrast, the emission intensity at 674 nm assigned to the CDs remained constant, resulting in the ratiometric sensing of O2·-. The present ratiometric nanoprobe showed high selectivity for O2·- monitoring due to the specific recognition of O2·- by CA. Moreover, the Golgi dots exhibited good linearity with respect to the O2·- concentration within 5 to 40 µM, and the limit of detection (LOD) was ~ 0.13 µM. Additionally, the Golgi dots showed low cytotoxicity and an ability to target the Golgi apparatus. Inspired by these excellent properties, we then applied the Golgi dots to successfully monitor exogenous and endogenous O2·- levels within the Golgi apparatus. Importantly, with the help of Golgi dots, we determined that SD substantially elevated O2·- levels in the brain.


Asunto(s)
Encéfalo , Ácidos Cafeicos , Polietilenos , Polipropilenos , Privación de Sueño , Animales , Ratones , Aparato de Golgi , Suplementos Dietéticos
14.
Anal Chem ; 96(18): 7014-7021, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38659215

RESUMEN

Membrane-based lateral flow immunoassays (LFAs) have been employed as early point-of-care (POC) testing tools in clinical settings. However, the varying membrane properties, uncontrollable sample transport in LFAs, visual readout, and required large sample volumes have been major limiting factors in realizing needed sensitivity and desirable precise quantification. Addressing these challenges, we designed a membrane-free system in which the desirable three-dimensional (3D) structure of the detection zone is imitated and used a small pump for fluid flow and fluorescence as readout, all the while maintaining a one-step assay protocol. A hydrogel-like protein-polyelectrolyte complex (PPC) within a polyelectrolyte multilayer (PEM) was developed as the test line by complexing polystreptavidin (pSA) with poly(diallyldimethylammonium chloride) (PDDA), which in turn was layered with poly(acrylic acid) (PAA) resulting in a superior 3D streptavidin-rich test line. Since the remainder of the microchannel remains material-free, good flow control is achieved, and with the total volume of 20 µL, 7.5-fold smaller sample volumes can be used in comparison to conventional LFAs. High sensitivity with desirable reproducibility and a 20 min total assay time were achieved for the detection of NT-proBNP in plasma with a dynamic range of 60-9000 pg·mL-1 and a limit of detection of 56 pg·mL-1 using probe antibody-modified fluorescence nanoparticles. While instrument-free visual detection is no longer possible, the developed lateral flow channel platform has the potential to dramatically expand the LFA applicability, as it overcomes the limitations of membrane-based immunoassays, ultimately improving the accuracy and reducing the sample volume so that finger-prick analyses can easily be done in a one-step assay for analytes present at very low concentrations.


Asunto(s)
Biomarcadores , Compuestos de Amonio Cuaternario , Humanos , Inmunoensayo/métodos , Biomarcadores/análisis , Biomarcadores/sangre , Péptido Natriurético Encefálico/sangre , Péptido Natriurético Encefálico/análisis , Límite de Detección , Resinas Acrílicas/química , Fragmentos de Péptidos/análisis , Fragmentos de Péptidos/sangre , Polietilenos/química , Poliestirenos/química
15.
Anal Methods ; 16(19): 3030-3038, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38682263

RESUMEN

In this work, a sensitive colorimetric bioassay method based on a poly(adenine) aptamer (polyA apt) and gold nanoparticles (AuNPs) was developed for the determination of aflatoxin B1 (AFB1). The polyA apt, adsorbed on the AuNPs, especially can bind to the analyte while deterring non-specific interactions. This nano aptasensor uses cationic polymer poly(diallyl dimethyl ammonium chloride) (PDDA), as an aggregating agent, to aggregate gold nanoparticles. PolyA apt-decorated gold nanoparticles (AuNPs/polyA apt) show resistance to PDDA-induced aggregation and maintains their dispersed state (red color) with the optical absorbance signal at λ = 520 nm. However, in the presence of AFB1 in the assay solution, the specific aptamer reacts with high affinity and folds into its three-dimensional form. Aggregation of AuNPs induced by PDDA caused their optical signal shift to λ = 620 nm (blue color). AFB1 concentration in the bioassay solution determines the amount of optical signal shift. Therefore, optical density ratio in two wavelengths (A620/520) can be used as a sturdy colorimetric signal to detect the concentration of aflatoxin B1. AFB1 was linearly detected between 0.5 and 20 ng mL-1, with a detection limit of 0.09 ng mL-1 (S/N = 3). The fabricated aptasensor was applied to the detection of AFB1 in real corn samples.


Asunto(s)
Aflatoxina B1 , Aptámeros de Nucleótidos , Colorimetría , Oro , Nanopartículas del Metal , Zea mays , Aflatoxina B1/análisis , Aflatoxina B1/química , Oro/química , Colorimetría/métodos , Zea mays/química , Nanopartículas del Metal/química , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Poli A/química , Límite de Detección , Contaminación de Alimentos/análisis , Compuestos de Amonio Cuaternario/química , Polietilenos
16.
Nanoscale Horiz ; 9(5): 863-872, 2024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38533738

RESUMEN

The behavior of polyelectrolytes in confined spaces has direct relevance to the protein mediated ion transport in living organisms. In this paper, we govern lithium chloride transport by the interface provided by polyelectrolytes, polycation, poly(diallyldimethylammonium chloride) (PDDA) and, polyanion, double stranded deoxyribonucleic acid (dsDNA), in confined graphene oxide (GO) membranes. Polyelectrolyte-GO interfaces demonstrate neuromorphic functions that were successfully applied with nanochannel ion interactions contributed, resulting in ion memory effects. Excitatory and inhibitory post-synaptic currents were tuned continuously as the number of pulses applied increased accordingly, increasing decay times. Furthermore, we demonstrated the short-term memory of a trained vs untrained device in computation. On account of its simple and safe production along with its robustness and stability, we anticipate our device to be a low dimensional building block for arrays to embed artificial neural networks in hardware for neuromorphic computing. Additionally, incorporating such devices with sensing and actuating parts for a complete feedback loop produces robotics with its own ability to learn by modifying actuation based on sensing data.


Asunto(s)
ADN , Grafito , Polietilenos , Compuestos de Amonio Cuaternario , Grafito/química , ADN/química , Compuestos de Amonio Cuaternario/química , Polietilenos/química , Redes Neurales de la Computación , Membranas Artificiales , Óxidos/química
17.
Proc Inst Mech Eng H ; 238(4): 438-443, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38439747

RESUMEN

With low wear rates shown by contemporary bearing materials of total hip prostheses, the standard deviation of wear rate is relatively high. Therefore, large sample sizes are needed for an adequate power of test. Because wear tests take a long time, it is practical to test several samples simultaneously. A new high-capacity, multidirectional wear test device, called the SuperCTPOD-200, was introduced. A 3 million-cycle wear test with an unprecedented sample size of 200 was performed for VEXLPE. The duration of the test was 6 weeks. The wear factor was normally distributed with a mean ± SD of 1.64 × 10-7 mm3/Nm ± 0.22 × 10-7 mm3/Nm (n = 200). The observation that SD was 13.1% of the mean can be useful in power analyses of future tests with other highly cross-linked polyethylenes. Burnishing was the most typical feature on the worn pins, which was in agreement with clinical findings on retrieved acetabular liners. The present study emphasizes statistics that often plays a minor role only in wear studies.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Ensayo de Materiales , Óxido de Aluminio , Polietilenos , Falla de Prótesis
18.
J Chromatogr A ; 1720: 464802, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38507871

RESUMEN

Successive multiple ionic-polymer layers (SMILs) have long since proved their worth in capillary electrophoresis as they ensure stable electroosmotic flow (EOF) and relatively high separation efficiency. Recently, we demonstrated that plotting the plate height (H) against the solute migration velocity (u) enabled a reliable quantitative evaluation of the coating performances in terms of separation efficiency. In this work, various physicochemical and chemical parameters of the SMIL coating were studied and optimized in order to decrease the slope of the ascending part of the H vs u curve, which is known to be controlled by the homogeneity in charge of the coating surface and by the possible residual solute adsorption onto the coating surface. SMILs based on poly(diallyldimethylammonium chloride) (PDADMAC) and poly(sodium styrene sulfonate) (PSS) were formed and the effect of each polyelectrolyte molar mass and of the number of polyelectrolyte layers (up to 21 layers) was studied. The use of polyethylene imine as an anchoring first layer was considered. More polyelectrolyte couples based on PDADMAC, polybrene, PSS, poly(vinyl sulfate), and poly(acrylic acid) were tested. Finally, zwitterionic polymers based on the poly(α-l-lysine) scaffold were synthesized and used as the last layer of SMILs, illustrating their ability to finetune the EOF, while maintaining good separation efficiency.


Asunto(s)
Electroforesis Capilar , Polietilenos , Polímeros , Compuestos de Amonio Cuaternario , Polielectrolitos , Cationes , Electroforesis Capilar/métodos , Proteínas/análisis , Polietileneimina
19.
J Appl Biomater Funct Mater ; 22: 22808000241240296, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38509449

RESUMEN

Joint replacements provide pain free movement for the injured or our aging population. Current prothesis mainly consist of hard metal on metal, or ceramic femoral head on ultra-high-molecular weight polyethylene (UHMWPE). In this study, a rodent fracture model was used to test the influence of wear debris from a high-performance polymer (polyimide MP-1™). Saline, MP-1™ Low Dose in Saline (1%), or MP-1 High Dose (2%) in Saline was injected directly into a standard closed unilateral femoral fracture in 12-week old Sprague Dawley rats (n = 25) for 1, 3 and 6 weeks. Endpoints included radiography, micro-computed tomography, mechanical testing and paraffin histology. No adverse effects from the wear particles were observed from the current study based on radiology, mechanical or histological data. Although the particles were present, histological analysis revealed a progression in healing between the Polyimide treated groups and the non-treated saline control groups over the duration of 1, 3, and 6 weeks, with no inhibition from the particles. The MP-1™ wear debris generated are larger than 1 µm thus are not able to be engulfed by macrophages and cause osteolysis. This family of polymers (polyimides) may be an ideal material to consider for articulating joints and other implants in the human body.


Asunto(s)
Curación de Fractura , Prótesis de Cadera , Humanos , Animales , Ratas , Anciano , Microtomografía por Rayos X , Ratas Sprague-Dawley , Polietilenos/efectos adversos , Macrófagos , Falla de Prótesis , Prótesis de Cadera/efectos adversos
20.
Int J Nanomedicine ; 19: 2691-2708, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38510793

RESUMEN

Purpose: Patients afflicted with dry eye disease (DED) experience significant discomfort. The underlying cause of DED is the excessive accumulation of ROS on the ocular surface. Here, we investigated the nitrogen doped-graphene quantum dots (NGQDs), known for their ROS-scavenging capabilities, as a treatment for DED. Methods: NGQDs were prepared by using citric acid and urea as precursors through hydrothermal method. The antioxidant abilities of NGQDs were evaluated through: scavenging the ROS both extracellular and intracellular, regulating the nuclear factor-erythroid 2-related factor (Nrf2) antioxidant pathway of human corneal epithelial cells (HCECs) and their transcription of inflammation related genes. Furthermore, NGQDs were modified by Arg-Gly-Asp-Ser (RGDS) peptides to obtain RGDS@NGQDs. In vivo, both the NGQDs and RGDS@NGQDs were suspended in 0.1% Pluronic F127 (w/v) and delivered as eye drops in the scopolamine hydrobromide-induced DED mouse model. Preclinical efficacy was compared to the healthy and DPBS treated DED mice. Results: These NGQDs demonstrated pronounced antioxidant properties, efficiently neutralizing free radicals and activating the intracellular Nrf2 pathway. In vitro studies revealed that treatment of H2O2-exposed HCECs with NGQDs induced a preservation in cell viability. Additionally, there was a reduction in the transcription of inflammation-associated genes. To prolong the corneal residence time of NGQDs, they were further modified with RGDS peptides and suspended in 0.1% Pluronic F127 (w/v) to create RGDS@NGQDs F127 eye drops. RGDS@NGQDs exhibited superior intracellular antioxidant activity even at low concentrations (10 µg/mL). Subsequent in vivo studies revealed that RGDS@NGQDs F127 eye drops notably mitigated the symptoms of DED mouse model, primarily by reducing ocular ROS levels. Conclusion: Our findings underscore the enhanced antioxidant benefits achieved by modifying GQDs through nitrogen doping and RGDS peptide tethering. Importantly, in a mouse model, our novel eye drops formulation effectively ameliorated DED symptoms, thereby representing a novel therapeutic pathway for DED management.


Asunto(s)
Síndromes de Ojo Seco , Grafito , Polietilenos , Polipropilenos , Puntos Cuánticos , Ratones , Humanos , Animales , Antioxidantes/farmacología , Especies Reactivas de Oxígeno , Grafito/química , Puntos Cuánticos/química , Nitrógeno/química , Peróxido de Hidrógeno , Factor 2 Relacionado con NF-E2 , Poloxámero , Síndromes de Ojo Seco/tratamiento farmacológico , Inflamación , Soluciones Oftálmicas , Péptidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA