Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.523
Filtrar
1.
Ophthalmic Physiol Opt ; 44(6): 1072-1083, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39031645

RESUMEN

PURPOSE: SpotChecks is a new contrast sensitivity (CS) test designed for self-monitoring of vision. This study assessed the test-retest repeatability of take-home SpotChecks, in-office SpotChecks and near Pelli-Robson charts in healthy adults. METHODS: One eye of 61 healthy adults with near visual acuity (VA) of 6/9 or better (age range 22-84, mean 49 [18] years) was tested during two office visits (mean 10 [8] days apart). Each visit included high-contrast VA, then 12 randomly ordered CS tests (6 different SpotChecks and 6 different Pelli-Robson) under the same lighting (luminance 110 cd/m2), all at near in the same eye with habitual correction. The same eye was self-tested with take-home SpotChecks once a day on 6 days between the office visits. SpotChecks was scored by the logCS at the highest line with ≥2 errors. Pelli-Robson was scored by [0.05 × number of letters read correctly - 0.15]. Repeatability of logCS was defined as 1.96 2 Sw, Sw representing within-subject standard deviation. Comparison for repeatability was performed with Bootstrap hypothesis test. RESULTS: SpotChecks and Pelli-Robson showed similar intra-session or inter-visit repeatability (p = 0.14-0.81). Inter-day repeatability for take-home SpotChecks was 0.18 logCS, the same as that from the first measurements of two office visits with SpotChecks or Pelli-Robson. Inter-visit repeatability improved to 0.15 by using the average of two repeated measurements for SpotChecks (p = 0.02) or three repeated measurements for Pelli-Robson (p = 0.04). Age showed a small effect on logCS (-0.015/decade, p = 0.02) for both SpotChecks and Pelli-Robson. Mean logCS was 0.05 lower in those ≥50 years (SpotChecks 1.84 [0.10] and Pelli-Robson 1.77 [0.10]) compared with those <50 years of age (SpotChecks 1.89 [0.07] and Pelli-Robson 1.83 [0.07]). CONCLUSIONS: SpotChecks showed good repeatability with take-home and in-office testing in healthy adults, making it a promising tool for monitoring disease progression at home.


Asunto(s)
Sensibilidad de Contraste , Pruebas de Visión , Agudeza Visual , Humanos , Sensibilidad de Contraste/fisiología , Adulto , Femenino , Masculino , Persona de Mediana Edad , Pruebas de Visión/métodos , Pruebas de Visión/instrumentación , Adulto Joven , Reproducibilidad de los Resultados , Anciano , Agudeza Visual/fisiología , Anciano de 80 o más Años , Voluntarios Sanos
2.
JAMA Ophthalmol ; 142(6): 512-520, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38662399

RESUMEN

Importance: Most neovascular age-related macular degeneration (nAMD) treatments involve long-term follow-up of disease activity. Home-monitoring would reduce the burden on patients and their caregivers and release clinic capacity. Objective: To evaluate 3 vision home-monitoring tests for patients to use to detect active nAMD compared with diagnosing active nAMD at hospital follow-up during the after-treatment monitoring phase. Design, Setting, and Participants: This was a diagnostic test accuracy study wherein the reference standard was detection of active nAMD by an ophthalmologist at hospital follow-up. The 3 home-monitoring tests evaluated included the following: (1) the KeepSight Journal (KSJ [International Macular and Retinal Foundation]), which contains paper-based near-vision tests presented as word puzzles, (2) the MyVisionTrack (mVT [Genentech]) vision-monitoring mobile app, viewed on an Apple mobile operating system-based device, and (3) the MultiBit (MBT [Visumetrics]) app, viewed on an Apple mobile operating system-based device. Participants were asked to test weekly; mVT and MBT scores were transmitted automatically, and KSJ scores were returned to the research office every 6 months. Raw scores between hospital follow-ups were summarized as averages. Patients were recruited from 6 UK hospital eye clinics and were 50 years and older with at least 1 eye first treated for active nAMD for at least 6 months or longer to a maximum of 42 months before approach. Participants were stratified by time since starting treatment. Study data were analyzed from May to September 2021. Exposures: The KSJ, mVT, and MBT were compared with the reference standard (in-hospital ophthalmologist examination). Main Outcomes and Measures: Estimated area under receiver operating characteristic curve (AUROC). The study had 90% power to detect a difference of 0.06, or 80% power to detect a difference of 0.05, if the AUROC for 2 tests was 0.75. Results: A total of 297 patients (mean [SD] age, 74.9 [6.6] years; 174 female [58.6%]) were included in the study. At least 1 hospital follow-up was available for 312 study eyes in 259 participants (1549 complete visits). Median (IQR) home-monitoring testing frequency was 3 (1-4) times per month. Estimated AUROC was less than 0.6 for all home-monitoring tests, and only the KSJ summary score was associated with lesion activity (odds ratio, 3.48; 95% CI, 1.09-11.13; P = .04). Conclusions and Relevance: Results suggest that no home-monitoring vision test evaluated provided satisfactory diagnostic accuracy to identify active nAMD diagnosed in hospital eye service follow-up clinics. Implementing any of these evaluated tests, with ophthalmologists only reviewing test positives, would mean most active lesions were missed, risking unnecessary sight loss.


Asunto(s)
Pruebas de Visión , Agudeza Visual , Degeneración Macular Húmeda , Humanos , Masculino , Femenino , Anciano , Agudeza Visual/fisiología , Pruebas de Visión/instrumentación , Degeneración Macular Húmeda/diagnóstico , Degeneración Macular Húmeda/tratamiento farmacológico , Degeneración Macular Húmeda/fisiopatología , Anciano de 80 o más Años , Curva ROC , Reproducibilidad de los Resultados , Aplicaciones Móviles , Estudios de Seguimiento , Inhibidores de la Angiogénesis/uso terapéutico , Inhibidores de la Angiogénesis/administración & dosificación , Tomografía de Coherencia Óptica
3.
Indian J Ophthalmol ; 72(Suppl 3): S505-S508, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648459

RESUMEN

PURPOSE: The Pelli-Robson and LEA contrast sensitivity charts are commonly used in clinical settings to measure contrast sensitivity. Although the Pelli-Robson chart is considered the gold standard, it is limited by its bulky size. The LEA chart, on the contrary, offers a more practical and portable option that is still reliable. This has led to questions about whether we can predict Pelli-Robson scores based on LEA scores. This study developed a conversion method to help transition from the LEA chart to the Pelli-Robson chart and validate the conversion score. METHODS: In this retrospective study, we analyzed the relationship between LEA and the Pelli-Robson contrast sensitivity test. Our study examined a total of 120 eyes. We developed a conversion table through the equipercentile equating method. Subsequently, we assessed the reliability and accuracy of this algorithm for converting LEA results into Pelli-Robson contrast sensitivity scores. RESULTS: The study used a conversion table to convert LEA scores to Pelli-Robson scores. The conversion table achieved a reliability of 0.91 based on intraclass correlation, and the algorithm had an accuracy of 81.6% within a 1-point difference from the raw score. CONCLUSIONS: This study reported a reliable and comparable conversion algorithm for transforming LEA scores into converted estimated Pelli-Robson scores, thereby improving the usefulness of existing data in both clinical and research contexts.


Asunto(s)
Sensibilidad de Contraste , Humanos , Sensibilidad de Contraste/fisiología , Estudios Retrospectivos , Masculino , Femenino , Adulto , Reproducibilidad de los Resultados , Persona de Mediana Edad , Pruebas de Visión/métodos , Pruebas de Visión/instrumentación , Oftalmología/métodos , Adulto Joven , Agudeza Visual/fisiología , Neurología/métodos , Algoritmos , Anciano , Adolescente
4.
Eye (Lond) ; 38(12): 2406-2414, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38509183

RESUMEN

With the advances in smartphone and tablet screens, as well as their processing power and software, mobile apps have been developed reporting to assess visual function. This review assessed those mobile apps that have been evaluated in the scientific literature to measure visual acuity, reading metrics, contrast sensitivity, stereoacuity, colour vision and visual fields; these constitute just a small percentage of the total number of mobile apps reporting to measure these metrics available for tablets and smartphones. In general, research suggests that most of the mobile apps evaluated can accurately mimic most traditionally paper-based tests of visual function, benefitting from more even illumination from the backlit screen and aspects such as multiple tests and versions (to minimise memorisation) being available on the same equipment. Some also utilise the in-built device sensors to monitor aspects such as working distance and screen tilt. As the consequences of incorrectly recording visual function and using this to inform clinical management are serious, clinicians must check on the validity of a mobile app before adopting it as part of clinical practice.


Asunto(s)
Aplicaciones Móviles , Pruebas de Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Pruebas de Visión/métodos , Pruebas de Visión/instrumentación , Sensibilidad de Contraste/fisiología , Campos Visuales/fisiología , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/fisiopatología , Visión de Colores/fisiología , Teléfono Inteligente , Lectura
5.
Br J Ophthalmol ; 108(11): 1613-1620, 2024 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-38514167

RESUMEN

BACKGROUND: To develop and assess the usability of a smartphone-based visual acuity (VA) test with an automatic distance calibration (ADC) function, the iOS version of WHOeyes. METHODS: The WHOeyes was an upgraded version with a distinct feature of ADC of an existing validated VA testing app called V@home. Three groups of Chinese participants with different ages (≤20, 20-40, >40 years) were recruited for distance and near VA testing using both an Early Treatment Diabetic Retinopathy Study (ETDRS) chart and the WHOeyes. The ADC function would determine the testing distance. Infrared rangefinder was used to determine the testing distance for the ETDRS, and actual testing distance for the WHOeyes. A questionnaire-based interview was administered to assess the satisfaction. RESULTS: The actual testing distance determined by the WHOeyes ADC showed an overall good agreement with the desired testing distance in all three age groups (p>0.50). Regarding the distance and near VA testing, the accuracy of WHOeyes was equivalent to ETDRS. The mean difference between the WHOeyes and ETDRS ranged from -0.084 to 0.012 logMAR, and the quadratic weighted kappa (QWK) values were >0.75 across all groups. The test-retest reliability of WHOeyes was high for both near and distance VA, with a mean difference ranging from -0.040 to 0.004 logMAR and QWK all >0.85. The questionnaire revealed an excellent user experience and acceptance of WHOeyes. CONCLUSIONS: WHOeyes could provide accurate measurement of the testing distance as well as the distance and near VA when compared to the gold standard ETDRS chart.


Asunto(s)
Teléfono Inteligente , Pruebas de Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Femenino , Masculino , Adulto , Pruebas de Visión/instrumentación , Pruebas de Visión/métodos , Adulto Joven , Persona de Mediana Edad , Calibración , Encuestas y Cuestionarios , Reproducibilidad de los Resultados , Anciano , Aplicaciones Móviles
6.
Clin Exp Optom ; 107(6): 635-640, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38350442

RESUMEN

CLINICAL RELEVANCE: Understanding devices used for vision screening, including their potential utilisation and validity, will facilitate proper utilisation of this technology. BACKGROUND: The Acuidrive is a self-illuminated, hand-held, visual acuity screening device intended for use in policing, with visual acuity assessed roadside to identify drivers who may not meet vision standards for driving. The target is presented binocularly at 24 cm, and +4.00 D lenses eliminate the accommodation requirement. This study investigates its validity and applicability relative to the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. METHODS: There were 36 participants, half younger adults aged 18-30 years and half older adults aged 50-70 years. The subjects underwent binocular visual acuity testing using the Acuidrive device and an ETDRS chart displayed on a monitor. Eyes were corrected for distance using lenses in a trial frame, and additional trial lenses provided four blur levels: zero, +0.50 DS, +1.00 DS and +1.50 DS. Luminances for the devices were similar at approximately 100 cd/m2. ETDRS chart measurements were conducted both with room lighting on and off. RESULTS: The Acuidrive device underestimated the ETDRS visual acuity across all blur levels, with mean differences of 0.24 ± 0.07 logMAR and 0.18 ± 0.10 logMAR for room lights on and off, respectively. To predict ETDRS visual acuity of poorer than 0.34 logMAR (6/12=), a screening level of 0.50 logMAR (6/19) with the Acuidrive device provided high sensitivity and specificity (86% and 79% with lights-on, and 85% and 78% with lights-off). Visual acuity was better for the older group than the younger group by approximately 0.10 logMAR. CONCLUSION: There was an offset of 0.2 logMAR (two lines) between visual acuity measures for the Acuidrive device and an ETDRS chart. The Acuidrive device has the potential to be a viable screening tool with refinement to its construction.


Asunto(s)
Selección Visual , Agudeza Visual , Humanos , Persona de Mediana Edad , Selección Visual/instrumentación , Selección Visual/métodos , Adulto , Anciano , Agudeza Visual/fisiología , Adolescente , Adulto Joven , Masculino , Femenino , Reproducibilidad de los Resultados , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/fisiopatología , Diseño de Equipo , Conducción de Automóvil , Sensibilidad y Especificidad , Pruebas de Visión/instrumentación
7.
Eye (Lond) ; 38(8): 1556-1561, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38321175

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the equivalence of smartphone-based measurements of near visual acuity under different screen brightness conditions with a standard near visual acuity test. METHODS: On a sample of 85 participants, we have evaluated near visual acuity with a smartphone-based version of the Radner reading chart at three distinct screen brightness levels. Results have been compared with those obtained with classical Radner paper charts. RESULTS: We have found that, when a sufficient screen brightness is employed, the smartphone-based version of the Radner reading chart produces results that are in line with the paper Radner charts while low brightness levels lead to a significant underestimation of reading acuities. This result was consistent across different refractive conditions. CONCLUSIONS: In conclusion, we have shown that handheld devices, such as smartphones, can be potentially exploited for remote measurements of near visual acuity provided a correct control of brightness screen is employed.


Asunto(s)
Lectura , Teléfono Inteligente , Pruebas de Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Femenino , Masculino , Adulto , Pruebas de Visión/instrumentación , Pruebas de Visión/métodos , Adulto Joven , Persona de Mediana Edad , Adolescente
8.
J Optom ; 17(3): 100491, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38218113

RESUMEN

BACKGROUND AND OBJECTIVES: The invention described herein is a prototype based on computer vision technology that measures depth perception and is intended for the early examination of stereopsis. MATERIALS AND METHODS: The prototype (software and hardware) is a depth perception measurement system that consists on: (a) a screen showing stereoscopic models with a guide point that the subject must point to; (b) a camera capturing the distance between the screen and the subject's finger; and (c) a unit for recording, processing and storing the captured measurements. For test validation, the reproducibility and reliability of the platform were calculated by comparing results with standard stereoscopic tests. A demographic study of depth perception by subgroup analysis is shown. Subjective comparison of the different tests was carried out by means of a satisfaction survey. RESULTS: We included 94 subjects, 25 children and 69 adults, with a mean age of 34.2 ± 18.9 years; 36.2 % were men and 63.8 % were women. The DALE3D platform obtained good repeatability with an interclass correlation coefficient (ICC) between 0.94 and 0.87, and coefficient of variation (CV) between 0.1 and 0.26. Threshold determining optimal and suboptimal results was calculated for Randot and DALE3D test. Spearman's correlation coefficient, between thresholds was not statistically significant (p value > 0.05). The test was considered more visually appealing and easier to use by the participants (90 % maximum score). CONCLUSIONS: The DALE3D platform is a potentially useful tool for measuring depth perception with optimal reproducibility rates. Its innovative design makes it a more intuitive tool for children than current stereoscopic tests. Nevertheless, further studies will be needed to assess whether the depth perception measured by the DALE3D platform is a sufficiently reliable parameter to assess stereopsis.


Asunto(s)
Percepción de Profundidad , Humanos , Percepción de Profundidad/fisiología , Femenino , Masculino , Adulto , Reproducibilidad de los Resultados , Adulto Joven , Adolescente , Niño , Persona de Mediana Edad , Pruebas de Visión/instrumentación , Pruebas de Visión/métodos , Anciano , Diseño de Equipo , Visión Binocular/fisiología
9.
Rev. bras. oftalmol ; 83: e0036, 2024. graf
Artículo en Inglés | LILACS | ID: biblio-1565367

RESUMEN

ABSTRACT Objective: To study vertex-optical distance variation and estimate its impact on manifest refraction. Methods: Prospective study in a private clinic using the Vision-S™ 700 with five forehead positions. Forehead on the third position showed the closest vertex-optical distance of 12mm. Results: Analysis of 52 eyes from 26 patients revealed mean differences in vertex-optical distance of 12.25mm (right eye) and 11.75mm (left eye). A 2mm change in vertex-optical distance resulted in a 0.05D change for a 5D spherical equivalent and 0.20D for a 10D equivalent. Conclusion: Vertex-optical distance varies among patients and is influenced by forehead adjustment. These variations impact refraction accuracy and treatment evaluation. Adjusting the forehead to the third position on the Vision-S™ 700 is recommended.


RESUMO Objetivo: Estudar a variação da distância vértice-óptico, de acordo com o ajuste da testa, e estimar seu impacto na refração manifesta. Métodos: Estudo prospectivo realizado em clínica privada. A refração foi realizada utilizando cinco posições preestabelecidas com o Vision-Sa 700. A testa disposta na terceira posição apresentou distância vértice do refrator mais próxima de 12mm. Resultados: Foram analisados 52 olhos de 26 pacientes. A diferença média da distância vértice do refrator no olho direito foi de 12,25mm (variação de 11,50mm) e, no olho esquerdo, 11,75mm (variação de 12,00mm). O impacto foi de 2mm na distância vértice do refrator, fomentando em uma mudança de 0,05D para um equivalente esférico de 5D e 0,20D para um equivalente de 10D. Conclusão: A distância vértice do refrator varia entre pacientes, estando relacionada ao ajuste da testa. As variações afetam a precisão da refração, impactando no ajuste dos óculos, das lentes de contato e na avaliação pós-operatória de cirurgia refrativa. Sugerimos ajustar a posição da testa para terceira posição no Vision-S™ 700, se a distância vértice do refrator não for medida em todos os pacientes.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Optometría/instrumentación , Optometría/métodos , Refracción Ocular/fisiología , Pruebas de Visión/instrumentación , Pruebas de Visión/métodos , Lentes , Postura , Errores de Refracción , Cefalometría , Estudios Prospectivos , Procedimientos Quirúrgicos Refractivos , Óptica y Fotónica , Posicionamiento del Paciente
10.
Semin Ophthalmol ; 36(1-2): 41-45, 2021 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-33566722

RESUMEN

INTRODUCTION: The aim of this study is to evaluate distance stereoacuity in children with intermittent exotropia (IXT) using a computerized vision chart (CVC), to compare the results to the normal subjects, and to determine if any correlation between stereoacuity and IXT severity exits. METHODS: A prospective case-control study was conducted including 24 children with IXT and 25 age-matched normal subjects. The mean age was 8.9 ± 4.5 in IXT group and 9.4 ± 4.2 in control group. The majority of patients (n = 17) had basic type IXT. Full ophthalmic examinations, deviations and stereoacuity tests were evaluated. Stereoacuity was measured with the CVC for distance stereoacuity and Randot stereotest book for near stereoacuity. Level of fusional control in patients with IXT was assessed using Newcastle Control Score (NCS). Seven of the patients with IXT were also reevaluated postoperatively. RESULTS: Near stereoacuity was good in both IXT and control groups, and there was no significant difference between groups. There was a poor correlation between near stereoacuity and NCS (rs = 0.15, p = .48). Distance stereoacuity in the IXT group was significantly reduced compared to controls (p = .004). There was a positive correlation between distance stereoacuity values and NCS in patients with IXT (rs = 0.73, p < .001). CONCLUSION: Diminished distance stereoacuity in children with IXT can be detected with the CVC and this test may be useful for deciding the timing of surgical intervention and postoperative evaluation.


Asunto(s)
Diagnóstico por Computador , Exotropía/diagnóstico , Pruebas de Visión/instrumentación , Visión Binocular/fisiología , Agudeza Visual/fisiología , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Exotropía/fisiopatología , Femenino , Humanos , Masculino , Estudios Prospectivos
11.
J Neuroophthalmol ; 41(1): 19-23, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32868561

RESUMEN

BACKGROUND: Visual acuity has been a significant outcome measure in clinical trials for patients suffering from neuro-ophthalmological diseases and multiple sclerosis; however, there are limited data on the comparison of various testing strategies in pediatric patients with these disorders. Clinical trials using vision as an outcome could include a variety of tools to assess the acuity, including 2-m and 4-m standardized retroilluminated charts. METHODS: We investigated the difference in Early Treatment Diabetic Retinopathy Study (ETDRS) scores obtained using 2-m and 4-m charts, as well as the impact of optic neuritis, use of vision correction, age, and gender on visual acuity data from 71 patients with pediatric neuroimmunological conditions in a cross-sectional study. RESULTS: We determine that the ETDRS letter scores obtained using 4-m charts are on average 3.43 points less (P = 0.0034) when testing monocular ETDRS letter scores and on average 4.14 points less (P = 0.0008) when testing binocular ETDRS letter scores, relative to that obtained using the 2-m charts. However, we find that when performing monocular testing, optic neuritis in the eye being tested did not result in a statistically significant difference between 2-m and 4-m ETDRS letter scores. CONCLUSIONS: Although visual acuity charts are formatted by the distance, there are significant differences in the number of letters correctly identified between 2-m and 4-m charts. Although the differences may not impact the clinical acuity, research protocols should consider these differences before collapsing data across disparate studies.


Asunto(s)
Neuritis Óptica/diagnóstico , Trastornos de la Pupila/diagnóstico , Pruebas de Visión/instrumentación , Agudeza Visual/fisiología , Adolescente , Niño , Estudios Transversales , Femenino , Humanos , Masculino , Neuritis Óptica/fisiopatología , Trastornos de la Pupila/fisiopatología , Adulto Joven
12.
Acta Ophthalmol ; 99(3): 275-287, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32833321

RESUMEN

PURPOSE: A reliable reading test provides a standardized measure of the visual component of reading performance. This study evaluated reproducibility, agreement and feasibility of five Dutch language continuous text reading tests used in clinical practice and research in visually impaired participants. METHODS: In 42 participants with macular pathologies (mean age 77 years), the Colenbrander Reading Card (Colenbrander), International Reading Speed Texts (IReST), Laboratory of Experimental Ophthalmology (LEO) charts, 'de Nederlanders' (NED) and the Radner Reading Charts (Radner) were evaluated. The coefficient of repeatability was calculated for different reading parameters, and agreement between the reading tests was determined. RESULTS: Between the reading tests, the differences found in repeatability for reading performance were mainly within the limit of one line (0.1 logMAR). Exceptions were the inter-session repeatability for critical print size: Colenbrander (0.35 logMAR), LEO (0.34), Radner (0.23). The highest agreement was found between the LEO and Radner; Reading acuity bias 0.03 logMAR (SD 0.10), CPS 0.03 (0.12). CONCLUSION: This study shows that reading performance results obtained with reading tests are not always reliable and reading parameters could not always be properly assessed in participants with maculopathies. Therefore, choices regarding which reading test to use especially for research purposes should be based on both the feasibility and reliability of the reading test. The NED (a historical test) was the least feasible, and it is recommend that this test is no longer used. To allow standardized and comparable analysis of reading performance a highly standardized reading test, like the Radner is recommended.


Asunto(s)
Lectura , Pruebas de Visión/normas , Agudeza Visual , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Degeneración Macular/complicaciones , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Pruebas de Visión/instrumentación
13.
PLoS One ; 15(10): e0240933, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33112912

RESUMEN

PURPOSE: To assess the performance of an open-view binocular handheld aberrometer (QuickSee) for diagnosing refractive errors in children. METHODS: 123 school-age children (9.9 ± 3.3 years) with moderate refractive error underwent autorefraction (AR) with a standard desktop device and subjective refraction (SR), with or without cycloplegia to determine their eyeglass prescription. Measurements with QuickSee (QS) were taken in 62 of these patients without cycloplegia (NC), and in 61 under cycloplegia (C). Differences in refraction values (AR vs SR vs QS) as well as the visual acuity (VA) achieved by the patients with each method (QS vs SR) were used to evaluate the performance of the device in measuring refractive error. RESULTS: The spherical equivalent refraction obtained by QS agreed within 0.5 D of the SR in 71% (NC) and 70% (C) of the cases. Agreement between the desktop autorefractor and SR for the same threshold was of 61% (NC) and 77% (C). VA resulting from QS refractions was equal to or better than that achieved by SR procedure in 77% (NC) and 74% (C) of the patients. Average improvement in VA with the QS refractions was of 8.6 and 13.4 optotypes for the NC and C groups respectively, while the SR procedure provided average improvements of 8.9 (NC) and 14.8 (C) optotypes. CONCLUSIONS: The high level of agreement between QuickSee and subjective refraction together with the VA improvement achieved in both study groups using QuickSee refractions suggest that the device is a useful autorefraction tool for school-age children.


Asunto(s)
Errores de Refracción/diagnóstico , Pruebas de Visión/instrumentación , Adolescente , Niño , Preescolar , Anteojos , Femenino , Humanos , Masculino , Optometría/instrumentación , Optometría/métodos , Prescripciones , Refracción Ocular/fisiología , Instituciones Académicas , Pruebas de Visión/métodos , Agudeza Visual/fisiología
14.
Niger J Clin Pract ; 23(10): 1381-1386, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33047694

RESUMEN

BACKGROUND: Vision screening in children of preschool age (age 3-5 years) gives the opportunity for timely detection of amblyopia. The tools that would be used for screening must have high rates of testability in these young children, and must have high enough sensitivity and specificity to be reliable and cost effective. AIMS: To assess the performance of the Lea symbols chart as a screening tool in children aged 3 to 5 years attending primary schools in Kwara State, Nigeria. METHODS: Visual acuity (VA) of 464 children selected from 12 schools by a multistage sampling procedure was checked using the Lea symbols chart by trained Lea screeners. Children meeting the referral criteria and untestable children had a comprehensive eye examination. Testability rates, sensitivity, specificity, positive, and negative predictive values were analyzed based on age and gender, with corresponding significance values generated. RESULTS: Testability rates among 5 year olds were as high as 99.1%, decreasing significantly to 95.5% in 4 year olds and 85.7% in 3 year olds (p value < 0.001). Visual acuity performance improved with age (p value 0.002) but was unrelated to gender. The Lea symbols chart had an overall specificity of 77.4% (63.2% among 3 year olds and 83.5% among 5 year olds). At VA thresholds of 6/12 for 5 year olds and 6/15 for 3-4 year olds, the screening tool became 87.7% specific among 3 year olds and 94.3% specific among 5 year olds (overall 92.5%). CONCLUSION: The Lea symbols chart was found to be a useful screening tool in this environment, especially among 5 year olds. The reduced specificity among 3-4 year olds may prompt further research into the appropriate VA thresholds for 3-4 year olds to reduce the burden of unnecessary comprehensive eye evaluations resulting from too many false positive results.


Asunto(s)
Ambliopía/diagnóstico , Selección Visual/métodos , Pruebas de Visión/instrumentación , Preescolar , Estudios Transversales , Femenino , Humanos , Masculino , Nigeria , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Instituciones Académicas , Sensibilidad y Especificidad , Selección Visual/instrumentación , Agudeza Visual
15.
Optom Vis Sci ; 97(8): 591-597, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32833403

RESUMEN

SIGNIFICANCE: We developed a head-mounted display (HMD) as an automated way of testing visual acuity (VA) to increase workplace efficiency. This study raises its potential utility and advantages, analyzes reasons for its current limitations, and discusses areas of improvement in the development of this device. PURPOSE: Manual VA testing is important but labor-intensive in ophthalmology and optometry clinics. The purpose of this exploratory study is to assess the performance and identify potential limitations of an automated HMD for VA testing. METHODS: Sixty patients from National University Hospital, Singapore, were enrolled in a prospective observational study. The HMD was constructed based on the Snellen chart, with single optotypes displayed at a time. Each subject underwent VA testing of both eyes with the manual Snellen chart tested at 6 m from the subject and the HMD. RESULTS: Fifty-three subjects were included in the final analysis, with an incompletion rate of 11.7% (n = 7). The mean difference in estimated acuity between the HMD and Snellen chart was 0.05 logMAR. However, 95% limits of agreement were large at ±0.33 logMAR. The HMD overestimated vision in patients with poorer visual acuities. In detecting VA worse than 0.30 logMAR (6/12), sensitivity was 63.6% (95% confidence interval, 0.31 to 0.89%), and specificity was 81.0% (95% confidence interval, 0.66 to 0.91%). No significant correlation existed between mean difference and age (r = -0.15, P = .27) or education level (r = 0.04, P = .76). CONCLUSIONS: Advantages of our novel HMD technology include its fully automated nature and its portability. However, the device in its current form is not ready for widespread clinical use primarily because of its low accuracy, which is limited by both technical and user factors. Future studies are needed to improve its accuracy and completion rate and to evaluate for test-retest reliability in a larger population.


Asunto(s)
Pruebas de Visión/instrumentación , Agudeza Visual/fisiología , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/fisiopatología
16.
Optom Vis Sci ; 97(8): 616-627, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32833405

RESUMEN

SIGNIFICANCE: We validated a novel paradigm to measure aniseikonia across the visual field and used a mathematical approach that is able to describe the magnitude and shape of aniseikonia in a concise, clinically meaningful fashion. PURPOSE: The measurement of aniseikonia has been performed clinically for more than half a century; however, amalgamation of field-wide local variations in binocular spatial localization into clinically applicable global metrics has yet to be attempted. Thus, the goal of the current study was twofold: first, to measure field-wide aniseikonia and second, to compare how local and global metrics each capture optically induced aniseikonia. METHODS: Twelve visually normal observers performed a dichoptic localization task at 24 locations in the visual field. This was done in four conditions: (A) while wearing red-green filters, (B) while wearing green-red filters, (C) while wearing a monocular 5% overall size lens, and (D) while wearing a monocular 6% meridional size lens. The physical settings at perceptual equality were then used to compute both local (relative magnification) and global (coefficients for Zernike terms) descriptors of aniseikonia. RESULTS: The comparison of each lens condition to the baseline condition confirmed predicted shifts in both the sign and magnitude of aniseikonia at both the local and global levels; however, the intraobserver levels of precision were moderate, and systematic underestimations were present across all locations in conditions C and D. CONCLUSIONS: Local and global analyses derived from dichoptic localization data were both able to capture optically induced changes in binocular spatial perception; however, solutions that address the diagnostic and therapeutic challenges associated with this paradigm are needed before clinical implementation can proceed.


Asunto(s)
Aniseiconia/diagnóstico , Refracción Ocular/fisiología , Pruebas de Visión/instrumentación , Campos Visuales/fisiología , Adulto , Aniseiconia/fisiopatología , Anteojos , Femenino , Humanos , Masculino , Adulto Joven
18.
Optom Vis Sci ; 97(8): 573-582, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32769841

RESUMEN

SIGNIFICANCE: To judge the feasibility of virtual reality (VR) headsets for vision testing and treatment of binocular vision disorders and low vision, angular resolution (logMAR) and field of view must be known and may not be reliably provided. This is the first study to measure the limitations of VR systems for eye care applications. PURPOSE: This study aimed to measure, in a sample of VR headsets, eye-to-screen distance and other physical and optical characteristics needed to calculate minimum angular resolution in logMAR and field of view in determining feasibility for vision applications. METHODS: Eye-to-screen distance was measured, and logMAR, field of view, and maximum convergence demand were calculated for two standalone VR devices, Oculus Rift DK2 and HTC Vive, and, for four smartphone VR headsets, Zeiss VR1, Samsung Gear VR, VR Box, and SunnyPeak, each paired with four high-resolution smartphones, Samsung Galaxy S7/S8, iPhone X, and LG VR30. RESULTS: On average, the smallest letter that could be displayed in VR was 0.41 ± 0.09 (20/51), ranging from 0.59 (20/78) in the DK2 to 0.28 (20/39) in VR Box with S7. Mean field of view was 50.2 ± 4.8°, ranging from 39.6° in the VR Box with S7 to 55° in the HTC Vive. The mean field of view when used as a low vision aid was 23.0° and 12.7° for 2.2× and 4×, respectively. The mean maximum near convergence demand produced for a 60-mm interpupillary distance was 38.6 ± 10.1Δ. CONCLUSIONS: The minimum angular resolution in logMAR of current VR technology is insufficient for visual acuity testing and may be insufficient for standalone treatment of amblyopia. Field of view during movie watching or gaming is about half that reported by manufacturers but adequate for some types of visual field testing. Use for vergence testing and training is a concern for headsets with long eye-to-screen distance or interpupillary distances <60 mm.


Asunto(s)
Realidad Virtual , Pruebas de Visión/instrumentación , Baja Visión/rehabilitación , Campos Visuales/fisiología , Humanos , Procesamiento de Imagen Asistido por Computador , Visión Binocular/fisiología , Baja Visión/fisiopatología
19.
Optom Vis Sci ; 97(7): 509-517, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32697558

RESUMEN

SIGNIFICANCE: The International Reading Speed Texts (IReST) is a valid measure of reading speed in a Canadian sample. However, if clinicians desire to assess reading comprehension using the IReST, this will significantly reduce reading speeds of individuals with normal vision or reduced visual acuity and therefore should use the values presented here. PURPOSE: The purposes of this study are (1) to validate the IReST in an English-speaking Canadian sample and (2) to examine how reading comprehension questions and reduced visual acuity affect reading speed on the IReST. METHODS: For study 1, Canadian English speakers (n = 25) read all 10 IReST following the procedures used in the original IReST validation. For study 2, Canadian English speakers (n = 50) read all 10 IReST, half with normal/corrected-to-normal vision and half with reduced visual acuity, and were asked reading comprehension questions. RESULTS: No significant differences were found between Canadian sample and the published IReST values (in all cases, P > .05; mean difference [Mdiff] = -5.30 to +11.43; Cohen d = -0.15 to +0.27; Bayes factors = 0.41, 0.09). Assessing reading comprehension with multiple-choice questions on the IReST significantly reduced reading speeds in the normal vision condition (Mdiff = 25.3; 95% confidence interval, -16.7 to -34.1) and in the simulated impairment condition (Mdiff = 59.3; 95% confidence interval, -47.7 to -71). CONCLUSIONS: The IReST is a valid measure that can be used to assess reading speed in a Canadian English-speaking sample. If researchers/clinicians wish to assess both reading speed and comprehension, using multiple-choice reading comprehension questions, then the values provided by the IReST will likely underestimate an individual's true reading speed in individuals with normal/corrected-to-normal vision or reduced visual acuity.


Asunto(s)
Lectura , Trastornos de la Visión/diagnóstico , Pruebas de Visión/instrumentación , Adulto , Canadá , Comprensión , Femenino , Humanos , Lenguaje , Masculino , Persona de Mediana Edad , Estándares de Referencia , Encuestas y Cuestionarios , Trastornos de la Visión/fisiopatología , Pruebas de Visión/métodos , Agudeza Visual/fisiología , Vocabulario , Adulto Joven
20.
PLoS One ; 15(6): e0235290, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32598392

RESUMEN

This study evaluated the reproducibility of the Teller Acuity Cards (TAC) test, its correlation with the optotype test, and its usefulness for detecting amblyopia in preliterate children. We retrospectively reviewed the medical records of 64 children who had undergone the TAC test more than once and were later followed up with the optotype test. The mean corrected visual acuities (logMAR) of the first and last TAC tests were 0.86 (mean 19.9 months) and 0.69 (27.7 months), respectively. The first optotype acuity was 0.18 (33.7 months). The first TAC acuity result was positively correlated with the age of the child, but it was not statistically significant (r = -0.077, p > 0.05). The first and last TAC test acuities were significantly correlated (r = 0.382, p < 0.01). There was a significant but small correlation between the final TAC and the first optotype acuities (r = 0.193, p < 0.05). Interocular differences in visual acuity were significantly correlated between the last TAC and first optotype tests (r = 0.395, p < 0.05). TAC acuity might be a valid predictor of optotype acuity later on although it was underestimated compared to that in the optotype test. The TAC test can be used to detect unilateral amblyopia in preliterate children.


Asunto(s)
Ambliopía/diagnóstico , Pruebas de Visión/métodos , Agudeza Visual/fisiología , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Pruebas de Visión/clasificación , Pruebas de Visión/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA