Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 840
Filtrar
1.
Eye Contact Lens ; 50(7): 292-296, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39078501

RESUMEN

OBJECTIVE: Scleral lenses (SLs) can be customized using traditional diagnostic lens fitting or by using image- and/or impression-based technologies. This study describes the availability and usage of SL fitting technology in patients with keratoconus. METHODS: An online survey queried practitioners on the mode of practice, country of residence, and estimated number of SL fits completed for keratoconus. Practitioners were asked whether they had access to image- and/or impression-based technology and to estimate the percentage of fits completed using diagnostic fitting, image-based technology, and impression-based technology. Access and usage of technology was compared between academic and community practices, United States and non-United States, and high-volume (≥60 SLs) and low-volume fitters. RESULTS: 423 practitioners who fit SL for keratoconus participated. Image- and impression-based technologies were more frequently available in academic practices compared with community practices and high-volume compared with low-volume practitioners ( P <0.005). Practitioners with image-based technology used it for a median [interquartile range] 5 [25]% of SL fittings; those with impression-based technology used it for 8 [9]% of fittings, and those with both types of technology used image-based devices for 12 [23]% of fittings and impression-based for 5 [8]% of fittings. CONCLUSIONS: In this study, most participants report using diagnostic lenses to fit SLs for patients with keratoconus.


Asunto(s)
Lentes de Contacto , Queratocono , Ajuste de Prótesis , Esclerótica , Queratocono/terapia , Humanos , Masculino , Femenino , Adulto , Encuestas y Cuestionarios
2.
Prog Retin Eye Res ; 102: 101276, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38830532

RESUMEN

Changes in the biomechanical and biochemical properties of the human cornea play an important role in the pathogenesis of ectatic diseases. A number of conditions in primarily acquired (keratoconus or pellucid marginal degeneration) or secondarily induced (iatrogenic keratectasia after refractive laser surgeries) ectatic disorders lead to decreased biomechanical stability. Corneal collagen cross-linking (CXL) represents a technique to slow or even halt the progression of ectatic pathologies. In this procedure, riboflavin is applied in combination with ultraviolet A radiation. This interaction induces the production of reactive oxygen species, which leads to the formation of additional covalent bonds between collagen molecules and subsequent biomechanical corneal strengthening. This procedure is so far the only method that partially interferes etiopathogenetically in the treatment of ectatic diseases that slows or stops the process of corneal destabilization, otherwise leading to the need for corneal transplantation. Besides, CXL process increases markedly resistance of collagenous matrix against digesting enzymes supporting its use in the treatment of corneal ulcers. Since the discovery of this therapeutic procedure and the first laboratory experiments, which confirmed the validity of this method, and the first clinical studies that proved the effectiveness and safety of the technique, it has been spread and adopted worldwide, even with further modifications. Making use of the Bunsen-Roscoe photochemical law it was possible to shorten the duration of this procedure in accelerated CXL and thus improve the clinical workflow and patient compliance while maintaining the efficacy and safety of the procedure. The indication spectrum of CXL can be further expanded by combining it with other vision-enhancing procedures such as individualized topographically-guided excimer ablation. Complementing both techniques will allow a patient with a biomechanically stable cornea to regularize it and improve visual acuity without the need for tissue transplantation, leading to a long-term improvement in quality of life.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Humanos , Queratocono/tratamiento farmacológico , Queratocono/metabolismo , Queratocono/terapia , Riboflavina/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Reactivos de Enlaces Cruzados/uso terapéutico , Colágeno/metabolismo , Fotoquimioterapia/métodos , Córnea/metabolismo , Progresión de la Enfermedad
3.
Eye Contact Lens ; 50(8): 361-367, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38886964

RESUMEN

OBJECTIVES: To evaluate the visual outcome of mini-scleral contact lenses (MSLs) in keratoconus following the resolution of acute hydrops. METHODS: This was a prospective observational case series of patients of healed hydrops in keratoconus fitted with an MSL (Keracare, Acculens, Lakewood, CO) who were managed for acute hydrops medically or surgically at least 3 months prior. Uncorrected visual acuity, best spectacles-corrected visual acuity, best lens-corrected visual acuity, topographic indices, keratometric indices, contact lens parameters, and ocular aberrometric changes were evaluated. All patients were followed up for at least 3 months. RESULTS: Eighteen eyes of 17 patients were included in the analysis. The mean post-hydrops topographic values of the eyes included flat keratometric value (K1) 64.93±10.88 (range 44.30-93.40) diopters (D), steep keratometric value (K2) 70.41±10.92 D (range 45.8-98.6 D), and Kmax of 79.53±17.73 D (range 50-130.2). The final mini-scleral lens's mean dioptric power was -8.56±3.96 D (range -18 to -4). Visual acuity significantly improved from post-hydrops resolution uncorrected visual acuity of 1.5±0.71 logMAR to 0.79±0.18 logMAR best spectacles-corrected visual acuity to 0.27±0.01 logMAR best lens-corrected visual acuity ( P -value <0.0001). Similarly, there was considerable improvement in corneal aberrometric values after wearing an MSL. At the 3-month follow-up, 15 patients (16 eyes) were compliant to contact lens use with a minimum of 6 to 8 hr daily while two patients (2 eyes) were poorly compliant. CONCLUSIONS: A MSL is a valuable option for visual rehabilitation in keratoconus following the resolution of acute hydrops.


Asunto(s)
Lentes de Contacto , Topografía de la Córnea , Queratocono , Esclerótica , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Queratocono/fisiopatología , Queratocono/rehabilitación , Queratocono/complicaciones , Queratocono/terapia , Estudios Prospectivos , Masculino , Femenino , Adulto , Adulto Joven , Edema Corneal/fisiopatología , Edema Corneal/rehabilitación , Adolescente , Persona de Mediana Edad , Estudios de Seguimiento
4.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
5.
Ophthalmic Physiol Opt ; 44(5): 884-893, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38778634

RESUMEN

INTRODUCTION: Soft contact lenses may be a good alternative for early-stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). METHODS: Patients with Amsler-Krumeich grades I or II KC were fitted with small-diameter (14.2 or 14.8 mm) SoftK (SD-SoftK, cc = 0.48 mm) and large-diameter (17 mm) SoftK (LD-SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli-Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post-hoc analysis. RESULTS: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23-55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD-SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD-SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD-SoftK lenses significantly improved 10VA compared with habitual and LD-SoftK. SD-SoftK also significantly improved CS compared with habitual, but not LD-SoftK. LD-SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 µ vs. 0.07 ± 0.13 µ) but not SD-SoftK (0.04 ± 0.07 µ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD-SoftK (N = 3) compared with LD-SoftK (N = 8), and 75% of participants preferred SD-SoftK lenses. CONCLUSION: SD-SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD-SoftK lenses. SD-SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD-SoftK lenses.


Asunto(s)
Lentes de Contacto Hidrofílicos , Sensibilidad de Contraste , Topografía de la Córnea , Estudios Cruzados , Queratocono , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Masculino , Femenino , Estudios Prospectivos , Adulto , Agudeza Visual/fisiología , Adulto Joven , Sensibilidad de Contraste/fisiología , Topografía de la Córnea/métodos , Persona de Mediana Edad , Diseño de Equipo , Refracción Ocular/fisiología
6.
Cont Lens Anterior Eye ; 47(5): 102174, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38693011

RESUMEN

PURPOSE: This study describes efficiency of diagnostic, image-based, and impression-based fitting methods by eye care providers who prescribe scleral lenses (SL) for patients with keratoconus. METHODS: An electronic survey was distributed to eye care providers with an interest in SL fitting. Demographic data including practice modality, country of residence, and fitting volume were collected. Efficiency of each fitting method (diagnostic, image, and impression-guided) was queried including time required for initial evaluation, number of lenses ordered, and number of office visits required. Practitioners with access to image and impression-based technology were also asked time required to acquire data and to estimate the percentage of time a lens could be manufactured from the initial images or impressions. RESULTS: 423 practitioners who prescribe SL for patients with keratoconus reported completing a median [IQR] 100 [280] SL fittings. There was no difference in the median time required for initial evaluation (30 min; p = 0.5) or median number of lenses ordered during the fitting process (2 lenses; p = 0.2) between diagnostic, image-based, or impression-based SL fitting methods. Median time to acquire initial images was 10 [7] minutes and 15 [10] minutes to obtain impressions. Images obtained were adequate to order an initial lens 80 [45]% of the time while initial impressions were adequate 90 [40]%. CONCLUSION: In this study, practitioner-reported efficiency of SL fitting was similar between diagnostic, image-based and impression-based methods for patients with keratoconus.


Asunto(s)
Lentes de Contacto , Queratocono , Ajuste de Prótesis , Esclerótica , Queratocono/terapia , Queratocono/diagnóstico , Humanos , Femenino , Masculino , Adulto , Topografía de la Córnea
7.
Int Ophthalmol ; 44(1): 172, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38594548

RESUMEN

INTRODUCTION: Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. METHODS: In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. CONCLUSIONS: Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.


Asunto(s)
Astigmatismo , Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/etiología , Queratocono/terapia , Topografía de la Córnea/métodos , Córnea , Astigmatismo/diagnóstico , Trastornos de la Visión
8.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38557918

RESUMEN

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Asunto(s)
Lentes de Contacto Hidrofílicos , Reticulación Corneal , Queratocono , Fotoquimioterapia , Riboflavina , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Recuento de Células , Colágeno/metabolismo , Córnea/patología , Sustancia Propia/metabolismo , Topografía de la Córnea , Endotelio Corneal/patología , Estudios de Seguimiento , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/tratamiento farmacológico , Queratocono/terapia , Queratocono/metabolismo , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Refracción Ocular/fisiología , Estudios Retrospectivos , Riboflavina/uso terapéutico , Resultado del Tratamiento , Rayos Ultravioleta , Agudeza Visual/fisiología
9.
Eye Contact Lens ; 50(6): 255-258, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38652487

RESUMEN

OBJECTIVE: To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity. METHODS: Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.08) and 2 (≥0.08). Visual acuity, refractive index, and corneal topography indices were compared before and three months after lens use. RESULTS: Visual acuity, astigmatism, refractive error, corneal curvature, and corneal thickness improved significantly in both groups. Apical power and anterior elevation improved significantly in group 1, with small differences in eccentricity, but not in group 2. Changes in apical power before and after lens use were significantly different between the two groups. CONCLUSION: The RCL was effective for the cornea of keratoconus, especially when the prescription was made with a small difference in eccentricity.


Asunto(s)
Lentes de Contacto , Córnea , Topografía de la Córnea , Queratocono , Refracción Ocular , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/terapia , Estudios Retrospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Adulto , Refracción Ocular/fisiología , Adulto Joven , Córnea/patología , Córnea/fisiopatología , Adolescente , Astigmatismo/fisiopatología , Astigmatismo/terapia , Persona de Mediana Edad
10.
J Optom ; 17(3): 100514, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38324957

RESUMEN

PURPOSE: To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia. METHODS: A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached. RESULTS: Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges. CONCLUSIONS: Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.


Asunto(s)
Lentes de Contacto , Anteojos , Queratocono , Visión Binocular , Agudeza Visual , Humanos , Queratocono/terapia , Queratocono/fisiopatología , Queratocono/rehabilitación , Adulto , Visión Binocular/fisiología , Agudeza Visual/fisiología , Masculino , Estudios Prospectivos , Adulto Joven , Femenino , Adolescente
11.
Ophthalmology ; 131(8): 892-901, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38310973

RESUMEN

PURPOSE: Investigate trends in keratoconus (KCN) treatment patterns and diagnosis age from 2015 to 2020 and evaluate sociodemographic associations with the treatment approach. DESIGN: Retrospective cohort study. PARTICIPANTS: Patients with a new KCN diagnosis from 2015 to 2020 were identified in the Academy IRIS® Registry (Intelligent Research in Sight). METHODS: Associations between sociodemographic factors and treatment were evaluated using multivariable logistic regression. MAIN OUTCOME MEASURES: Outcomes included percentages and rates of each treatment (collagen crosslinking [CXL], keratoplasty, or no procedure) from 2015 to 2020, age at diagnosis during this period, and sociodemographic factors associated with treatment type. RESULTS: A total of 66 199 patients with a new diagnosis of KCN were identified. The percentage of patients undergoing CXL increased from 0.05% in 2015 to 29.5% in 2020 (P = 0.008). The average age (standard deviation) of KCN patients decreased from 44.1 (±16.9) years in 2015 to 39.2 (±16.9) years in 2020 (P < 0.001). In multivariable analyses comparing CXL versus no procedure and keratoplasty versus no procedure, patients undergoing CXL tended to be younger with the odds of having CXL decreasing with increasing age, for example, comparing CXL and no procedure patients, using ages 0-20 years as reference, the odds ratio (OR) (95% confidence interval [CI]) decreased from 0.62 (0.57-0.67; P < 0.0001) for patients aged 21-40 years to 0.03 (0.02-0.04; P < 0.0001) for patients aged > 60 years. Men were more likely than women to have CXL (OR, 1.31; 95% CI, 1.23-1.40; P < 0.0001) and keratoplasty (OR, 1.30; 95% CI, 1.19-1.42; P < 0.0001). Black patients were less likely than White patients to have CXL (OR, 0.70; 95% CI, 0.63-0.77; P < 0.0001) and more likely to have keratoplasty (OR, 2.24; 95% CI, 2.01-2.50; P < 0.0001). Likewise, Hispanic patients had higher odds of CXL (OR, 1.12; 95% CI, 1.00-1.24; P < 0.05) and keratoplasty (OR, 1.29; 95% CI, 1.12-1.50; P < 0.001) compared with non-Hispanic patients. Collagen crosslinking and keratoplasty also varied by region and insurance status. CONCLUSIONS: A significant increase in use of CXL was noted from 2015 to 2020. Sociodemographic differences in treatment among KCN patients may reflect differences in access, use, or care patterns, and future studies should aim to identify strategies to improve access for all patients. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Asunto(s)
Academias e Institutos , Reactivos de Enlaces Cruzados , Queratocono , Oftalmología , Sistema de Registros , Humanos , Queratocono/tratamiento farmacológico , Queratocono/terapia , Masculino , Estudios Retrospectivos , Femenino , Adulto , Persona de Mediana Edad , Oftalmología/tendencias , Estados Unidos/epidemiología , Reactivos de Enlaces Cruzados/uso terapéutico , Adulto Joven , Fármacos Fotosensibilizantes/uso terapéutico , Colágeno/uso terapéutico , Rayos Ultravioleta , Riboflavina/uso terapéutico , Adolescente , Fotoquimioterapia , Factores Sociodemográficos , Anciano , Agudeza Visual/fisiología
12.
PLoS One ; 19(1): e0297268, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38206955

RESUMEN

Keratoconus is the most common primary corneal ectasia and is associated with significant morbidity. In its early stages, keratoconus is often asymptomatic, making the identification of subclinical disease challenging. Refractive error is a parameter that is documented at most routine optometry visits, yet interestingly, changes in refraction of keratoconic patients over time have not yet been studied and compared with the general population. Early diagnosis of keratoconus facilitates timely referral for treatments such as corneal collagen cross-linking, which has been shown to slow disease progression. In this context, documenting delays between initial presentation to the optometrist and referral for collagen-cross-linking as well as comparing the trends in visual acuity and refractive error between keratoconic and non-keratoconic patients over time are particularly relevant.


Asunto(s)
Queratocono , Errores de Refracción , Humanos , Queratocono/diagnóstico , Queratocono/epidemiología , Queratocono/terapia , Retraso del Tratamiento , Topografía de la Córnea , Australia/epidemiología , Errores de Refracción/terapia , Errores de Refracción/tratamiento farmacológico , Reactivos de Enlaces Cruzados/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Rayos Ultravioleta
13.
Eye Contact Lens ; 50(1): 10-15, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37967544

RESUMEN

OBJECTIVES: Defining the patterns of practice and referral criteria of optometrists within New Zealand to investigate the diagnosis and management of keratoconus. METHODS: Optometrists recruited through the New Zealand Association of Optometrists, Cornea and Contact Lens Society of New Zealand, and private practices were invited to complete an anonymous survey. RESULTS: Responses were received from 168 optometrists (representing 20.0% of the optometrist population). Half (48%) of optometrists had ≥15 years of experience, and 22% prescribed soft contact lenses daily, whereas only 6.4% prescribed rigid gas-permeable (RGP) lenses daily. The main barriers to prescribing RGPs were experience with fitting, low market demand, and patient discomfort. When referring to an ophthalmologist, 41% reported referring on progression of corneal parameters, 27% on initial diagnosis, 21% at no set time, and 10% with a reduction in visual acuity. Most optometrists (64%) would refer for possible surgery when visual acuity dropped between 6/9 and 6/12. Optometrists with greater experience were more likely to prescribe RGP lenses and co-manage patients with ophthalmologists. Ownership of a corneal imaging unit suggested an increased likelihood of prescribing RGP lenses but did not alter referral patterns. CONCLUSION: This survey provides an overview of current practice and highlights the importance of optometrists in the diagnosis and management of keratoconus. There was a significant discrepancy in keratoconus management, regarding optical correction modality and referral criteria for ophthalmology review. Further interdisciplinary work is required between optometry and ophthalmology to standardize referral guidelines and enhance visual outcomes.


Asunto(s)
Lentes de Contacto Hidrofílicos , Queratocono , Optometristas , Optometría , Humanos , Queratocono/diagnóstico , Queratocono/terapia , Encuestas y Cuestionarios
14.
Exp Eye Res ; 238: 109742, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38040051

RESUMEN

Keratoconus (KC) is characterized by the predominant primary ectatic disease, affecting the cornea, necessitating corneal transplants in some cases. While some loci associated with KC risk have been identified, the understanding of the disease remains limited. Superoxide dismutase (SOD) enzymes play a crucial role in countering the reactive oxygen species and providing protection against oxidative stress (OS). Accordingly, the objective of this study was to investigate a potential association of a 50 nucleotide base pairs (bp) insertion/deletion (I/D) within the SOD1 promoter, and the located 1684 bp upstream of the SOD1 ATG, with KC in the Iranian population. Additionally, an assessment was conducted on SOD activity and the total antioxidant capacity (TAC), as determined by the ferric reducing-antioxidant power assay, along with malondialdehyde (MDA) levels. In this case-control study, genomic DNA was extracted from the blood cells of KC (n = 402) and healthy (n = 331) individuals. The genotype of this gene was determined using the PCR technique. Furthermore, the amount of SOD enzyme activity and the MDA and TAC levels were measured in the serum of the study groups. The (I/I) genotype was present in 84.23%, the (I/D) genotype in 15.06%, and the (D/D) genotype in 0.69% of both groups. A statistically significant relationship was seen between different genotypes and TAC, MDA, and SOD1 activity indices (P < 0.05). Individuals with the D/D genotype exhibited a decrease in total antioxidant capacity, an increase in the amount of MDA, and a decrease in SOD1 enzyme activity (P < 0.05). Moreover, the logistic regression analysis of KC development indicated that elevated levels of MDA increased the risk of KC incidence in the patient group compared to the healthy group, while a higher activity of SOD1 and greater values of TAC decreased the KC risk. The removal of the 50 bp fragment reduced SOD1 activity and elevated OS levels, thereby impacting the oxidant-antioxidant balance. This could potentially play a significant role in individuals afflicted by KC.


Asunto(s)
Queratocono , Estrés Oxidativo , Superóxido Dismutasa-1 , Queratocono/epidemiología , Queratocono/genética , Queratocono/terapia , Estudios de Casos y Controles , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Humanos , Masculino , Femenino , Superóxido Dismutasa-1/genética , Modelos Logísticos , Curva ROC , Mutación INDEL
15.
Indian J Ophthalmol ; 72(1): 111-117, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38131580

RESUMEN

PURPOSE: This study aimed to report practice patterns in the management of keratoconus in India. METHODS: An e-survey was conducted among members of the Cornea Society of India to assess preferred practice patterns for keratoconus. RESULTS: Of the 912 members, 234 (25.7%) completed the survey. About 88.4% worked in private eye care facilities and 76.1% in cities. Of all the respondents, 91.5% had access to a Scheimpflug-based device or an Orbscan II®; 71.4% of the respondents dispensed scleral contact lenses, and 66.7% dispensed Rose K contact lenses; 92.7% of the respondents performed corneal cross-linking (CXL); and 73.1% of the respondents performed deep anterior lamellar keratoplasty (DALK). A Scheimpflug device or Orbscan II®, Rose K or scleral contact lenses, and CXL were more readily available (P < 0.05) in private eye care facilities. The diagnostic criteria for keratoconus followed by the majority of the respondents (52.1%) were increase in corneal curvature, elevation, and thickness. An increase in keratometry values greater than 0.5 or 1.0D in a 6-month to 1-year period was considered the most favored criterion for keratoconus progression. Epithelium-off, 0.1% riboflavin solution in dextran, and accelerated protocol were the more commonly reported techniques in CXL. About 77.2% of the respondents routinely performed CXL in corneas <400 microns thick. Spectacles (91.0% of the respondents) and topography-guided photorefractive keratectomy (37.6% of the respondents) were, respectively, the preferred optical and surgical methods used to improve vision. CONCLUSION: While keratoconus management in India is comparable to other developed healthcare systems, the concentration of trained corneal surgeons in cities and private eyecare facilities may lead to less equitable distribution of treatment across the country.


Asunto(s)
Queratocono , Fotoquimioterapia , Humanos , Colágeno/uso terapéutico , Córnea/cirugía , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/diagnóstico , Queratocono/epidemiología , Queratocono/terapia , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Rayos Ultravioleta , Agudeza Visual
16.
Eur J Ophthalmol ; 34(2): 394-398, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38128913

RESUMEN

PURPOSE: to assess optical aberrations under scleral (SL) versus rigid gas permeable (RGP) lenses in patients with keratoconus. METHODS: A prospective study including 25 eyes of 14 patients. The best-corrected visual acuity (BCVA) with corrective glasses, RGP and SL, stage of keratoconus (Amsler-Krumeich classification), minimum pachymetry, maximum keratometry, and corneal higher-order aberrations (i.e, total HOAs, coma, and trefoil) with RGP and with SL were collected. Aberrometry was performed using iTrace® aberrometer (Tracey Technologies, USA). RESULTS: 80% of the included keratoconus patients were stage 4, with a mean age of 34.3 years (±8.8). There were no significant differences in mean BCVA (logMAR) between SL and RGP. The mean BCVAs were significantly better both with SL (p < 0.0001) and RGP (p < 0.0001) compared with corrective glasses. Total HOAs (p = 0.01), coma (p = 0.003) and trefoil (p = 0.008) were significantly lower with SL compared with RGP. The BCVA decreased with the stage of keratoconus in SL (p = 0.01) and RGP (p = 0.02). The BCVA decreased with decreasing minimum pachymetry in SL (p = 0.02) and RGP (p = 0.002), and with increasing maximum keratometry in SL (p = 0.02) and RGP (p = 0.01). Significant correlations were found between BCVA, total HOAs (p = 0.008), and coma (p = 0.02) in SL. CONCLUSION: For the same keratoconus patients, total higher order, coma and trefoil optical aberrations were reduced with scleral lenses compared to rigid gas permeable lenses.


Asunto(s)
Lentes de Contacto , Queratocono , Humanos , Adulto , Queratocono/terapia , Agudeza Visual , Coma , Estudios Prospectivos , Topografía de la Córnea
18.
Optom Vis Sci ; 100(12): 876-881, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38019953

RESUMEN

SIGNIFICANCE: Technology plays a crucial role in customizing scleral lenses and improving lens alignment, especially in challenging scleral shapes. In addition, remote fitting technology allows optometrists to extend their expertise globally, empowering patients to access to customized lenses without travel expenses. PURPOSE: The objective of this study was to document the difficulties encountered in fitting a scleral lens in a patient with keratoconus and pronounced scleral toricity. In addition, the study aimed to present the successful remote fitting achieved by using advanced technology. CASE REPORT: An Irish male patient diagnosed with keratoconus exhibited high scleral toricity. Generally, keratoconus eyes often exhibit significant scleral asymmetry associated with cone decentration and disease severity. Improperly aligned scleral lenses can lead to regional changes in scleral shape, lens decentration, discomfort, and visual disturbances. Indeed, previous scleral lens fits were unsuccessful because of these issues. Corneoscleral profilometry was acquired in Ireland and then used in Italy to design customized lenses, which were then delivered to the patient's optometrist in Ireland. The first lenses designed and delivered demonstrated excellent overall performance without requiring adjustments. CONCLUSIONS: This report highlights the importance of corneoscleral profilometry to increase efficiency and reduce lens reorders and chair time, and the remote fitting in overcoming barriers to accessing specialized lens fitting.


Asunto(s)
Lentes de Contacto , Queratocono , Cristalino , Humanos , Masculino , Queratocono/complicaciones , Queratocono/terapia , Queratocono/diagnóstico , Agudeza Visual , Esclerótica , Ajuste de Prótesis
20.
Zhonghua Yan Ke Za Zhi ; 59(10): 832-837, 2023 Oct 11.
Artículo en Chino | MEDLINE | ID: mdl-37805417

RESUMEN

Objective: To investigate the efficacy of Femtosecond laser-assisted stromal lenticule addition keratoplasty (SLAK) combined with corneal collagen cross-linking (CXL) in the treatment of middle and advanced Keratoconus. Methods: It was a retrospective case series study. Data of 23 cases (24 eyes) of keratoconus treated with femtosecond laser-assisted SLAK combined with CXL in Laser Vision Centre of Xi'an No.1 Hospital from September 2020 to June 2022 were collected, including 16 males and 7 females, aged (23.69±5.18) years. The thickness, diopter number and diameter of the donor corneal stromal lens were assessed. uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), and diopter were recorded before and 1, 3, and 6 months after surgery. Sirius 3D fault corneal topography instrument to measure flat simulated keratometry (Kf), steep simulated keratometry (Ks) and the difference between them (ΔK), as well as central corneal thickness (CCT) and corneal high-order aberration. Results: Six months after surgery, CCT (454.83±50.01) µm were significantly higher than before (384.92±35.45) µm (P<0.05). Six months after surgery, UCVA (1.41±0.32) was significantly lower than before (1.11±0.33)(P<0.05). Six months after surgery, spherical diopter [(-15.73±7.89) D], Kf [(56.82±4.76) D] and Ks [(61.00±4.70) D] were significantly higher than before [(-12.08±5.99) D, (53.55±4.95) D, (58.65±5.10) D] (P<0.05). There was no significant difference in BCVA, column mirror degree and higher order aberrations before and 6 months after surgery(P>0.05). No corneal stromal lens folds, melting and displacement were observed in all eyes during the follow-up period, and no corneal opacity or immune rejection was observed. Conclusions: femtosecond laser-assisted SLAK combined with CXL can significantly increase the corneal thickness of keratoconus and has good effectiveness. In addition, six months of postoperative follow-up of patients showed no significant changes in BCVA and high-order aberrations in the 6 mm central diameter of the cornea, and no postoperative adverse reaction were found in all eyes, indicating that the operation has certain safety.


Asunto(s)
Trasplante de Córnea , Queratocono , Fotoquimioterapia , Masculino , Femenino , Humanos , Queratocono/terapia , Reticulación Corneal , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Retrospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta , Estudios de Seguimiento , Colágeno/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA