Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.252
Filtrar
2.
Radiol Cardiothorac Imaging ; 6(3): e230278, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38780426

RESUMEN

Purpose To develop a prediction model combining both clinical and CT texture analysis radiomics features for predicting pneumothorax complications in patients undergoing CT-guided core needle biopsy. Materials and Methods A total of 424 patients (mean age, 65.6 years ± 12.7 [SD]; 232 male, 192 female) who underwent CT-guided core needle biopsy between January 2021 and October 2022 were retrospectively included as the training data set. Clinical and procedure-related characteristics were documented. Texture analysis radiomics features were extracted from the subpleural lung parenchyma traversed by needle. Moderate pneumothorax was defined as a postprocedure air rim of 2 cm or greater. The prediction model was developed using logistic regression with backward elimination, presented by linear fusion of the selected features weighted by their coefficients. Model performance was assessed using the area under the receiver operating characteristic curve (AUC). Validation was conducted in an external cohort (n = 45; mean age, 58.2 years ± 12.7; 19 male, 26 female) from a different hospital. Results Moderate pneumothorax occurred in 12.0% (51 of 424) of the training cohort and 8.9% (four of 45) of the external test cohort. Patients with emphysema (P < .001) or a longer needle path length (P = .01) exhibited a higher incidence of moderate pneumothorax in the training cohort. Texture analysis features, including gray-level co-occurrence matrix cluster shade (P < .001), gray-level run-length matrix low gray-level run emphasis (P = .049), gray-level run-length matrix run entropy (P = .003), gray-level size-zone matrix gray-level variance (P < .001), and neighboring gray-tone difference matrix complexity (P < .001), showed higher values in patients with moderate pneumothorax. The combined clinical-radiomics model demonstrated satisfactory performance in both the training (AUC 0.78, accuracy = 71.9%) and external test cohorts (AUC 0.86, accuracy 73.3%). Conclusion The model integrating both clinical and radiomics features offered practical diagnostic performance and accuracy for predicting moderate pneumothorax in patients undergoing CT-guided core needle biopsy. Keywords: Biopsy/Needle Aspiration, Thorax, CT, Pneumothorax, Core Needle Biopsy, Texture Analysis, Radiomics, CT Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Biopsia Guiada por Imagen , Neumotórax , Tomografía Computarizada por Rayos X , Humanos , Neumotórax/etiología , Neumotórax/epidemiología , Neumotórax/diagnóstico por imagen , Masculino , Femenino , Anciano , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/efectos adversos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Biopsia con Aguja Gruesa/métodos , Biopsia con Aguja Gruesa/efectos adversos , Persona de Mediana Edad , Radiografía Intervencional/métodos , Pulmón/patología , Pulmón/diagnóstico por imagen , Valor Predictivo de las Pruebas , Radiómica
3.
Tomography ; 10(5): 686-692, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38787013

RESUMEN

(1) Background: Bacterial contamination has been shown to occur during angiographies, although data on its frequency and relevance are sparse. Our aim was to evaluate the incidence of bacterial contamination of syringes used under sterile conditions during neuroangiographies. We sought to differentiate between contamination of the outside of the syringes and the inside and to detect the frequency, extent and germ spectrum of bacterial contamination. (2) Methods: We prospectively collected 600 samples from 100 neuroangiographies. Per angiography, fluid samples from the three routinely used syringes as well as the syringes themselves were analyzed. We analyzed the frequency and extent of contamination and determined the germ spectrum. (3) Results: The majority of samples (56.9%) were contaminated. There was no angiography that showed no contamination (0%). The outer surfaces of the syringes were contaminated significantly more frequently and to a higher extent than the inner surfaces. Both the frequency and extent of contamination of the samples increased with longer duration of angiographic procedures. Most of the bacterial species were environmental or skin germs (87.7%). (4) Conclusions: Bacterial contamination is a frequent finding during neuroangiographies, although its clinical significance is believed to be small. Bacterial contamination increases with longer duration of angiographic procedures.


Asunto(s)
Contaminación de Equipos , Jeringas , Jeringas/microbiología , Humanos , Estudios Prospectivos , Bacterias/aislamiento & purificación , Angiografía Cerebral/métodos , Radiografía Intervencional/métodos
5.
Semin Musculoskelet Radiol ; 28(3): 267-281, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38768592

RESUMEN

The prevalence of knee osteoarthritis (OA) is the highest among all joints and likely to increase over the coming decades. Advances in the repertoire of diagnostic capabilities of imaging and an expansion in the availability and range of image-guided interventions has led to development of more advanced interventional procedures targeting pain related to OA pain while improving the function of patients presenting with this debilitating condition. We review the spectrum of established advanced interventional procedures for knee OA, describe the techniques used to perform these procedures safely, and discuss the clinical evidence supporting each of them.


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/terapia , Radiografía Intervencional/métodos , Inyecciones Intraarticulares/métodos
6.
Eur J Radiol ; 175: 111401, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38604091

RESUMEN

PURPOSE: Several studies report occupational orthopedic problems among interventional cardiologists. These health problems are usually multifactorial. However, the personal protective equipment used should play a major role. An online survey was conducted to determine the frequency of such health problems among interventional radiologists and to correlate them with the use of personal radiation protective clothing. MATERIAL AND METHODS: An anonymous online survey that comprised of 17 questions was sent via e-mail to 1427 members of the German Society for Interventional Radiology (DeGIR) in Germany, Austria and Switzerland. The questions were focused on interventional workload, the use of personal radiation protection apparel and orthopedic problems. Given the different scale levels, the associations between the variables were analyzed using different statistical methods. A significance level of p < 0.05 was chosen. RESULTS: There were 221 survey responders (15.5% response rate). About half of responders (47.7%) suffered from more than five episodes of orthopedic problems during their interventional career. Lumbar spine was involved in 81.7% of these cases, cervical spine in 32.8%, shoulder in 28.5% and knee in 24.7%. Because of orthopedic problems, 16.1% of the responders had to reduce and 2.7% had to stop their interventional practice. The number of affected body regions correlates with the fit of the radiation protection means (p < 0.05, r = 0.135) and the reduction of activity as an interventional radiologist (p < 0.05, r = -0.148). CONCLUSION: Overall, the survey reveals widespread orthopedic problems at several body regions among interventional radiologists, associated with the fit of radiation protection systems, among other factors. A connection between the orthopaedic complaints and the radiation protection system used could not be established.


Asunto(s)
Enfermedades Profesionales , Protección Radiológica , Radiología Intervencionista , Humanos , Protección Radiológica/métodos , Radiología Intervencionista/estadística & datos numéricos , Femenino , Masculino , Enfermedades Profesionales/prevención & control , Enfermedades Profesionales/epidemiología , Enfermedades Profesionales/etiología , Alemania/epidemiología , Encuestas y Cuestionarios , Adulto , Exposición Profesional/prevención & control , Exposición Profesional/estadística & datos numéricos , Ropa de Protección/estadística & datos numéricos , Persona de Mediana Edad , Enfermedades Musculoesqueléticas/prevención & control , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Radiografía Intervencional/estadística & datos numéricos , Austria/epidemiología
7.
Radiat Prot Dosimetry ; 200(7): 693-699, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38679858

RESUMEN

This study presented a model applied for potential risk assessment in an interventional radiology setting. The model of potential risk assessment (MARP) consisted of the creation of a scale of indicators ranging from 0 to 5. The radiation levels were categorized according to gender, kind of procedure, value of kerma air product (Pka), and accumulated radiation dose (mGy). The MARP model was applied in 121 institutions over 8 y. A total of 201 656 patient radiation doses (Dose-area product and accumulated kerma) data were launched into the system over time, with an average of 22 406 doses per year. In the context of the workers (cardiologists, radiographers, and nurses) monitored during the MARP application, 8007 cases (with an average of 890 per year) of occupational radiation doses were recorded. This study showed a strategy for quality evaluation in fluoroscopy using a model with a compulsory information system for monitoring safety.


Asunto(s)
Exposición Profesional , Dosis de Radiación , Humanos , Fluoroscopía/métodos , Medición de Riesgo/métodos , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Femenino , Masculino , Radiografía Intervencional/efectos adversos , Monitoreo de Radiación/métodos , Protección Radiológica/normas , Protección Radiológica/métodos , Radiología Intervencionista/métodos , Radiología Intervencionista/normas , Exposición a la Radiación/análisis
8.
Abdom Radiol (NY) ; 49(5): 1646-1652, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38592493

RESUMEN

PURPOSE: To evaluate the efficacy and safety of a novel technique for removal of migrated esophageal stent (MES) under fluoroscopy. METHODS: From January 2009 to April 2023, 793 patients with a dysphagia score of 3-4 underwent esophageal stenting at our center, and 25 patients (mean age: 70.06 years old; male/female: 15/10) underwent stent removal using "loop method" under fluoroscopy. The primary outcomes were technical success and complications. The secondary outcomes were procedure time, radiation exposure, biochemical indicators [white blood cell (WBC), hemoglobin (Hb), platelet (PLT), albumin (ALB), alanine transaminase (ALT), total bilirubin (TB), urea nitrogen (UN) and C-reactive protein] of pre- and post-treatment at 2 weeks. RESULTS: Technical success was 100% without major complications. The mean procedure time was (39.44 ± 9.28) minutes, which showed no statistical significance between benign (n = 5) and malignant (n = 20) group [(42.40 ± 8.85) vs (38.71 ± 9.46) mins, p > 0.05]. The mean radiation exposure was (332.88 ± 261.47) mGy, which showed no statistical significance between benign and malignant group [(360.74 ± 231.43) vs (325.92 ± 273.54) mGy, p > 0.05]. Pre- and post-procedure Hb [(114.46 ± 11.96) vs. (117.57 ± 13.12) g/L] and ALB [(42.26 ± 3.39) vs. (44.12 ± 3.77) g/L] showed significant difference (p < 0.05), while WBC, PLT, CRP, and ALT showed no significance (p > 0.05). CONCLUSION: Fluoroscopy-guided "Loop method" for MES removal is an effective and safe alternative technique.


Asunto(s)
Remoción de Dispositivos , Stents , Humanos , Femenino , Fluoroscopía , Masculino , Anciano , Remoción de Dispositivos/métodos , Migración de Cuerpo Extraño/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Trastornos de Deglución/etiología , Radiografía Intervencional/métodos , Anciano de 80 o más Años
9.
Vasa ; 53(3): 193-203, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38651340

RESUMEN

Endovascular interventions and diagnostic examinations using iodinated contrast media (ICM) are standard of care in current vascular medicine. Although ICM use is generally considered safe, it may be associated with adverse reactions, vary from minor disturbances to rare, but severe life-threatening complications. This position paper of European Society of Vascular Medicine integrates current knowledge and summarizes the key information related to the use of intravascular ICM, serving as recommendation on prevention and management of acute, late, and very late adverse reactions. It should help the health professionals in all fields of vascular medicine to make decisions in daily practice for safe use of contrast media.


Asunto(s)
Medios de Contraste , Procedimientos Endovasculares , Humanos , Consenso , Medios de Contraste/efectos adversos , Medios de Contraste/administración & dosificación , Procedimientos Endovasculares/efectos adversos , Compuestos de Yodo/efectos adversos , Radiografía Intervencional/efectos adversos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
10.
Cardiovasc Intervent Radiol ; 47(5): 621-631, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639781

RESUMEN

PURPOSE: CT-guided percutaneous core biopsy of the lung is usually performed under local anesthesia, but can also be conducted under additional systemic opioid medication. The purpose of this retrospective study was to assess the effect of intravenous piritramide application on the pneumothorax rate and to identify risk factors for post-biopsy pneumothorax. MATERIALS AND METHODS: One hundred and seventy-one core biopsies of the lung were included in this retrospective single center study. The incidence of pneumothorax and chest tube placement was evaluated. Patient-, procedure- and target-related variables were analyzed by univariate and multivariable logistic regression analysis. RESULTS: The overall incidence of pneumothorax was 39.2% (67/171). The pneumothorax rate was 31.5% (29/92) in patients who received intravenous piritramide and 48.1% (38/79) in patients who did not receive piritramide. In multivariable logistic regression analysis periinterventional piritramide application proved to be the only independent factor to reduce the risk of pneumothorax (odds ratio 0.46, 95%-confidence interval 0.24, 0.88; p = 0.018). Two or more pleura passages (odds ratio 3.38, 95%-confidence interval: 1.15, 9.87; p = 0.026) and prone position of the patient (odds ratio 2.27, 95%-confidence interval: 1.04, 4.94; p = 0.039) were independent risk factors for a higher pneumothorax rate. CONCLUSION: Procedural opioid medication with piritramide proved to be a previously undisclosed factor decreasing the risk of pneumothorax associated with CT-guided percutaneous core biopsy of the lung. LEVEL OF EVIDENCE 4: small study cohort.


Asunto(s)
Analgésicos Opioides , Biopsia Guiada por Imagen , Pulmón , Pirinitramida , Neumotórax , Radiografía Intervencional , Tomografía Computarizada por Rayos X , Humanos , Neumotórax/prevención & control , Neumotórax/etiología , Femenino , Masculino , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Persona de Mediana Edad , Analgésicos Opioides/administración & dosificación , Radiografía Intervencional/métodos , Anciano , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Factores de Riesgo , Pulmón/diagnóstico por imagen , Pulmón/patología , Pirinitramida/administración & dosificación , Pirinitramida/uso terapéutico , Adulto , Incidencia
11.
Cardiovasc Intervent Radiol ; 47(5): 573-582, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38561521

RESUMEN

PURPOSE: To retrospectively compare long-term oncologic outcomes of percutaneous computed tomography-guided microwave ablation (MWA) and robot-assisted partial nephrectomy (RAPN) for the treatment of stage 1 (T1a and T1b) renal cell carcinoma (RCC) patients. MATERIALS AND METHODS: Institutional database research identified all T1 RCC patients who underwent either MWA or RAPN. Models were adjusted with propensity score matching. Kaplan-Meier log-rank test analyses and Cox proportional hazard regression models were used to compare the oncologic outcomes. Patient and tumor characteristics, technical success as well as oncologic outcomes were evaluated and compared between the 2 groups. RESULTS: After propensity score matching, a total of 71 patients underwent percutaneous MWA (mean age 70 ± 10 years) and 71 underwent RAPN (mean age 60 ± 9 years). At 8-year follow-up, the estimated survival rates for MWA cohort were 98% (95% confidence interval [CI] 95-100%) for overall survival, 97% (95% CI 93-100%) for recurrence-free survival, and 97% (95% CI 93-100%) for metastasis-free survival. The matched cohort that underwent RAPN exhibited survival rates of 100% (95% CI 100-100%) for overall survival, 98% (95% CI 94-100%) for recurrence-free survival, and 98% (95% CI 94-100%) for metastasis-free survival. After performing log-rank testing, these rates were not significantly different (p values of 0.44, 0.67, and 0.67, respectively). CONCLUSION: The results of the present study suggest that both MWA and RAPN are equally effective in terms of oncologic outcome for the treatment of T1 RCC.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Microondas , Nefrectomía , Puntaje de Propensión , Procedimientos Quirúrgicos Robotizados , Humanos , Carcinoma de Células Renales/cirugía , Carcinoma de Células Renales/patología , Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Neoplasias Renales/diagnóstico por imagen , Masculino , Femenino , Nefrectomía/métodos , Microondas/uso terapéutico , Anciano , Persona de Mediana Edad , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Estudios de Seguimiento , Resultado del Tratamiento , Estadificación de Neoplasias , Tomografía Computarizada por Rayos X , Radiografía Intervencional/métodos , Tasa de Supervivencia
13.
Radiographics ; 44(5): e230115, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38662586

RESUMEN

Adrenal vein sampling (AVS) is the standard method for distinguishing unilateral from bilateral sources of autonomous aldosterone production in patients with primary aldosteronism. This procedure has been performed at limited specialized centers due to its technical complexity. With recent advances in imaging technology and knowledge of adrenal vein anatomy in parallel with the development of adjunctive techniques, AVS has become easier to perform, even at nonspecialized centers. Although rare, anatomic variants of the adrenal veins can cause sampling failure or misinterpretation of the sampling results. The inferior accessory hepatic vein and the inferior emissary vein are useful anatomic landmarks for right adrenal vein cannulation, which is the most difficult and crucial step in AVS. Meticulous assessment of adrenal vein anatomy on multidetector CT images and the use of a catheter suitable for the anatomy are crucial for adrenal vein cannulation. Adjunctive techniques such as intraprocedural cortisol assay, cone-beam CT, and coaxial guidewire-catheter techniques are useful tools to confirm right adrenal vein cannulation or to troubleshoot difficult blood sampling. Interventional radiologists should be involved in interpreting the sampling results because technical factors may affect the results. In rare instances, bilateral adrenal suppression, in which aldosterone-to-cortisol ratios of both adrenal glands are lower than that of the inferior vena cava, can be encountered. Repeat sampling may be necessary in this situation. Collaboration with endocrinology and laboratory medicine services is of great importance to optimize the quality of the samples and for smooth and successful operation. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Asunto(s)
Glándulas Suprarrenales , Hiperaldosteronismo , Humanos , Glándulas Suprarrenales/irrigación sanguínea , Glándulas Suprarrenales/diagnóstico por imagen , Hiperaldosteronismo/diagnóstico por imagen , Venas/diagnóstico por imagen , Aldosterona/sangre , Venas Hepáticas/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Puntos Anatómicos de Referencia , Radiografía Intervencional/métodos
17.
Phys Med ; 120: 103330, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38522409

RESUMEN

OBJECTIVES: To evaluate the effect of equipment technology on reference point air kerma (Ka,r), air kerma-area product (PKA), and fluoroscopic time for fluoroscopically-guided gastrointestinal endoscopic procedures and establish benchmark levels. METHODS: This retrospective study included the consecutive patients who underwent fluoroscopically-guided gastrointestinal endoscopic procedures from May 2016 to August 2023 at a tertiary care hospital in the U.S. Fluoroscopic systems included (a) Omega CS-50 e-View, (b) GE Precision 500D, and (c) Siemens Cios Alpha. Radiation dose was analyzed for four procedure types of endoscopic retrograde biliary, pancreas, biliary and pancreas combined, and other guidance. Median and 75th percentile values were computed using software package R (version 4.0.5, R Foundation). RESULTS: This large study analyzed 9,459 gastrointestinal endoscopic procedures. Among four procedure types, median Ka,r was 108.8-433.2 mGy (a), 70-272 mGy (b), and 22-55.1 mGy (c). Median PKA was 20.9-49.5 Gy∙cm2 (a), 13.4-39.7 Gy∙cm2 (b), and 8.91-20.9 Gy∙cm2 (c). Median fluoroscopic time was 2.8-8.1 min (a), 3.6-9.2 min (b), and 2.9-9.4 min (c). Their median value ratio (a:b:c) was 8.5:4.8:1 (Ka,r), 2.7:2.1:1 (PKA), and 1.0:1.1:1 (fluoroscopic time). Median value and 75th percentile are presented for Ka,r, PKA, and fluoroscopic time for each procedure type, which can function as benchmark for comparison for dose optimization studies. CONCLUSION: This study shows manifold variation in doses (Ka,r and PKA) among three fluoroscopic equipment types and provides local reference levels (50th and 75th percentiles) for four gastrointestinal endoscopic procedure types. Besides procedure type, imaging technology should be considered for establishing diagnostic reference level. SUMMARY: With manifold (2 to 12 times) variation in doses observed in this study among 3 machines, we recommend development of technology-based diagnostic reference levels for gastrointestinal endoscopic procedures.


Asunto(s)
Niveles de Referencia para Diagnóstico , Radiografía Intervencional , Humanos , Estudios Retrospectivos , Dosis de Radiación , Radiografía Intervencional/métodos , Fluoroscopía/métodos
18.
Cardiovasc Intervent Radiol ; 47(Suppl 3): 41-54, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38438683
19.
Clin Radiol ; 79(6): e785-e790, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38388255

RESUMEN

AIM: To evaluate if real-time dose visualisation during computed tomography (CT)-guided interventions leads to a reduction in radiation dose to participating radiologists. MATERIALS AND METHODS: The individual radiation dose radiologists are exposed to during CT interventions was measured using dedicated dosimeters (RaySafe i2-system, Unfors RaySafe GmbH, Billdal, Sweden) worn over the usual radiation protective apron. Initially, only the total radiation dose was measured, without visualisation (control group). In the following study period, the radiation dose was shown to participants on a live screen in real-time (experimental group). In both groups, the dose was recorded in 1-second intervals. The results collected were evaluated by comparison using descriptive statistics and mixed-effect models. In particular, the variables experience, gender, role, and position during the intervention were analysed. RESULTS: In total, 517 measurements of 304 interventions (n=249 with and n=268 without live screen) performed by 29 radiologists acting as interventionalists or assistants were analysed. All CT-guided interventions were performed percutaneously, the majority of which (n=280) were microwave ablations (MWA). Radiation doses in the group without visualisation were comparable with usual dose rates for the corresponding intervention type. The mean total radiation dose was reduced by 58.1% (11.6 versus 4.86 µSv) in the experimental group (p=0.034). The highest reduction of 78.5% (15.55 versus 3.35 µSv) was observed in radiologists with the role of assistant (p=0.002). Sub-analysis showed significant dose reduction (p<0.0001) for the use of live screen in general; considering all variables, the role "assistant" alone had a statistically significant influence (p=0.002). CONCLUSION: The real-time visualisation of active radiation dose during CT interventions leads to a relevant reduction in radiation dose to participating radiologists.


Asunto(s)
Exposición Profesional , Dosis de Radiación , Protección Radiológica , Radiólogos , Tomografía Computarizada por Rayos X , Humanos , Femenino , Tomografía Computarizada por Rayos X/métodos , Protección Radiológica/métodos , Masculino , Exposición Profesional/prevención & control , Exposición Profesional/análisis , Radiografía Intervencional/métodos , Adulto , Persona de Mediana Edad
20.
J Vasc Surg ; 79(6): 1306-1314.e2, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38368998

RESUMEN

OBJECTIVE: Radiation exposure during complex endovascular aortic repair may be associated with tangible adverse effects in patients and operators. This study aimed to identify the steps of highest radiation exposure during fenestrated endovascular aortic repair (FEVAR) and to investigate potential intraoperative factors affecting radiation exposure. METHODS: Prospective data of 31 consecutive patients managed exclusively with four-fenestration endografts between March 1, 2020, and July 1, 2022 were retrospectively analyzed. Leveraging the conformity of the applied technique, every FEVAR operation was considered a combination of six overall stages composed of 28 standardized steps. Intraoperative parameters, including air kerma, dose area product, fluoroscopy time, and number of digital subtraction angiographies (DSAs) and average angulations were collected and analyzed for each step. RESULTS: The mean procedure duration and fluoroscopy time was 140 minutes (standard deviation [SD], 32 minutes), and 40 minutes (SD, 9.1 minutes), respectively. The mean air kerma was 814 mGy (SD, 498 mGy), and the mean dose area product was 66.8 Gy cm2 (SD, 33 Gy cm2). The percentage of air kerma of the entire procedure was distributed throughout the following procedure stages: preparation (13.9%), main body (9.6%), target vessel cannulation (27.8%), stent deployment (29.1%), distal aortoiliac grafting (14.3%), and completion (5.3%). DSAs represented 23.0% of the total air kerma. Target vessel cannulation and stent deployment presented the highest mean lateral angulation (67 and 63 degrees, respectively). Using linear regression, each minute of continuous fluoroscopy added 18.9 mGy of air kerma (95% confidence interval, 17.6-20.2 mGy), and each DSA series added 21.1 mGy of air kerma (95% confidence interval, 17.9-24.3 mGy). Body mass index and lateral angulation were significantly associated with increased air kerma (P < .001). CONCLUSIONS: Cannulation of target vessels and bridging stent deployment are the steps requiring the highest radiation exposure during FEVAR cases. Optimized operator protection during these steps is mandatory.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Dosis de Radiación , Exposición a la Radiación , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Exposición a la Radiación/prevención & control , Exposición a la Radiación/efectos adversos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Factores de Tiempo , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Prótesis Vascular , Anciano de 80 o más Años , Stents , Resultado del Tratamiento , Medición de Riesgo , Tempo Operativo , Aortografía , Persona de Mediana Edad , Angiografía de Substracción Digital , Exposición Profesional/prevención & control , Exposición Profesional/efectos adversos , Fluoroscopía , Reparación Endovascular de Aneurismas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA