Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 820
Filtrar
1.
Med Sci Monit ; 30: e944946, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38980833

RESUMEN

BACKGROUND Platelets have important modulatory effects on inflammatory and immune-mediated pathways. Thrombocytopenia is a critical condition that is frequently encountered in the intensive care unit (ICU) and increases mortality. This retrospective study of 472 patients admitted to the ICU with acute exacerbation of chronic obstructive pulmonary disease (COPD) aimed to evaluate thrombocytopenia and mean platelet volume (MPV) with prognosis and patient mortality. MATERIAL AND METHODS A total of 472 patients diagnosed with COPD according to GOLD criteria and hospitalized in the tertiary ICU between 1 April 2018 and 11 May 2021 were included in the study. Platelets were calculated by the impetance method and MPV was simultaneously calculated based on the platelet histogram. Patients with platelet count ≤100×109/L and >100×109/L and patients with MPV values <7 fl, 7-11 fl, and >11fl were compared in terms of mortality and prognosis. RESULTS The mortality rate in COPD patients with thrombocytopenia was high, at 61.5%. Thrombocytopenia (P=.002), high MPV (P=.006) Acute Physiology and Chronic Health Evaluation-2 (APACHE-II) score (P=.025), length of stay (LOS) in the ICU (P=.009), mechanical ventilation duration (P<.001), leukocytosis (P<.001), high Sequential Organ Failure Assessment (SOFA) score (P<.001), LOS in the hospital (P=.035), and hypoalbuminemia (P<.001) were significantly associated with mortality. CONCLUSIONS Thrombocytopenia, high MPV, high APACHE-II and SOFA scores, LOS in the ICU and hospital, duration of mechanical ventilation, leukocytosis, and hypoalbuminemia predict mortality in COPD patients. Since infection-sepsis, hypoalbuminemia, and hypoxia can worsen this situation, ensuring early infection control, providing albumin support, and preventing hypoxia contribute significantly to reducing thrombocytopenia and mortality.


Asunto(s)
Unidades de Cuidados Intensivos , Volúmen Plaquetario Medio , Enfermedad Pulmonar Obstructiva Crónica , Trombocitopenia , Humanos , Enfermedad Pulmonar Obstructiva Crónica/sangre , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/mortalidad , Femenino , Masculino , Pronóstico , Volúmen Plaquetario Medio/métodos , Trombocitopenia/sangre , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Recuento de Plaquetas/métodos , APACHE , Tiempo de Internación , Plaquetas/metabolismo , Mortalidad Hospitalaria
2.
Medicina (Kaunas) ; 60(6)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38929630

RESUMEN

Background: Contrast-induced nephropathy (CIN) is one of the most important complications after invasive cardiovascular procedures. Considering the pivotal role of inflammation in CIN development, the use of peripheral blood-based indexes may be an easily available biomarker to predict CIN risk. Therefore, in the present study, we evaluated the association between the pan-immune-inflammation value (PIV) and the risk of CIN. Patients and Methods: A total of 1343 patients undergoing coronary angiography (CAG) were included. The PIV was calculated with the following equation: (neutrophil count × platelet count × monocyte count)/lymphocyte count. Multivariable regression analyses were used to determine the association between clinical and laboratory parameters and CIN development. Results: The median age of the cohort was 58 (IQR 50-67), and 48.2% of the patients were female. CIN developed in 202 patients (15%) in follow-up. In multivariate analyses, older age (OR: 1.015, 95% CI: 1.002-1.028, p = 0.020) and higher PIV levels (OR: 1.016, 95% CI: 1.004-1.028, p = 0.008) were associated with a higher CIN risk, while the use of antiplatelet agents was associated with a lower risk of CIN (OR: 0.670, 95% CI: 0.475-0.945, p = 0.022). Conclusions: We demonstrated that the risk of CIN was significantly higher in patients with higher PIV and older patients in a large cohort of patients undergoing CAG for stable ischemic heart disease. If supported with prospective evidence, PIV levels could be used as a minimally invasive reflector of CIN.


Asunto(s)
Medios de Contraste , Angiografía Coronaria , Inflamación , Humanos , Femenino , Masculino , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Persona de Mediana Edad , Medios de Contraste/efectos adversos , Anciano , Inflamación/sangre , Factores de Riesgo , Enfermedades Renales/inducido químicamente , Biomarcadores/sangre , Recuento de Plaquetas/métodos , Recuento de Plaquetas/estadística & datos numéricos , Estudios de Cohortes
3.
Platelets ; 35(1): 2363242, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38860550

RESUMEN

Septic shock is a life-threatening disease worldwide often associated with thrombocytopenia. Platelets play a crucial role in bridging the gap between immunity, coagulation, and endothelial cell activation, potentially influencing the course of the disease. However, there are few studies specifically evaluating the impact of thrombocytopenia on the prognosis of pediatric patients. Therefore, the study investigates effects of early thrombocytopenia in the prognosis of children with septic shock. Pediatric patients with septic shock from 2015 to 2022 were included monocentrically. Thrombocytopenia was defined as a platelet count of <100 × 109/L during the first 24 hours of septic shock onset. The primary outcome was the 28-day mortality. Propensity score matching was used to pair patients with different platelet counts on admission but comparable disease severity. A total of 419 pediatric patients were included in the analysis. Patients with thrombocytopenia had higher 28-day mortality (55.5% vs. 38.7%, p = .005) compared to patients with no thrombocytopenia. Thrombocytopenia was associated with reduced 28-PICU free days (median value, 0 vs. 13 days, p = .003) and 28-ventilator-free (median value, 0 vs. 19 days, p = .001) days. Among thrombocytopenia patients, those with platelet count ≤50 × 109/L had a higher 28-day mortality rate (63.6% vs. 45%, p = .02). Multiple logistic regression showed that elevated lactate (adjusted odds ratio (OR) = 1.11; 95% confidence interval (CI): 1.04-1.17; P <0.001) and white blood cell (WBC) count (OR = 0.97; 95% CI: 0.95-0.99; p = .003) were independent risk factors for the development of thrombocytopenia. Thrombocytopenia group had increased bleeding events, blood product transfusions, and development of organ failure. In Kaplan-Meier survival estimates, survival probabilities at 28 days were greater in patients without thrombocytopenia (p value from the log-rank test, p = .004). There were no significant differences in the type of pathogenic microorganisms and the site of infection between patients with and without thrombocytopenia. In conclusion, thrombocytopenia within 24 hours of shock onset is associated with an increased risk of 28-day mortality in pediatric patients with septic shock.


What is the context? Septic shock is a life-threatening disease worldwide, leading to higher mortality.Platelets play a crucial role in bridging the gap between immunity, coagulation, and endothelial cell activation.Although it is known that platelets are associated with prognosis, most studies have focused on adult populations. Limited data are available on the incidence of thrombocytopenia and its correlation with clinical outcomes , specifically, in pediatric patients with sepsis and septic shock. What is new? The present study suggests that thrombocytopenia within 24 hours of septic shock onset reflects a reliable tool for predicting the prognosis of septic shock in pediatric patients.Furthermore, elevated lactate and reduced white-blood-cell count were independent risk factors for the development of thrombocytopenia in pediatric patients with septic shock. What is the impact? This study suggests that thrombocytopenia within 24 hours of septic shock onset is associated with an increased risk of 28-day mortality and decreased ventilation-free, PICU-free days in pediatric patients with septic shock. In septic shock, thrombocytopenia is also associated with increased bleeding events, blood product transfusions, and organ dysfunction.


Asunto(s)
Choque Séptico , Trombocitopenia , Humanos , Trombocitopenia/complicaciones , Trombocitopenia/sangre , Choque Séptico/complicaciones , Choque Séptico/mortalidad , Choque Séptico/sangre , Masculino , Femenino , Pronóstico , Estudios Retrospectivos , Niño , Preescolar , Lactante , Recuento de Plaquetas/métodos
4.
Tunis Med ; 102(6): 372-376, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38864202

RESUMEN

INTRODUCTION: Platelet count is crucial for clinical decision. In cases of microcytosis, platelet count based on impedance technique (PLT-I) may overestimate platelet count. AIM: To compare PLT-I with platelet count using the optical technique (PLT-O) and establish a Mean Corpuscular Volume (MCV) threshold for considering PLT-O. METHODS: A prospective analytical study conducted over two months involved blood samples collected in standard K2 EDTA tubes for complete blood count analysis, revealing microcytosis (MCV<80 fL). PLT-O analysis in channel-Ret mode was performed using the Sysmex-XN1000 (Sysmex Corporation, Kobe, Japan). Percentage of fragmented red cells (FRC%) and percentage of microcytic red cells (Micro-R%) were recorded. Blood smears stained with May-Grünwald-Giemsa were examined for potential interfering particles. RESULTS: A strong correlation was observed between the two techniques for all platelet values as well as for PLT <150 x 109/L (correlation coefficient r = 0.971, 95% CI: [0.956-0.982]; P<10-3 and r = 0.90, 95% CI: [0.79-0.95]; P< 10-3). The Bland-Altman plot revealed a bias of 16.53 x 109/L between the two methods, with agreement limits between -55.8 and 88.8 x 109/L. A threshold MCV value indicating the use of the optical method, with a cut-off at 72.9fL, demonstrated promising performance consistent with literature findings. However, less favorable performance was observed with Micro-R%. CONCLUSION: Impedance could be employed in routine practice. However, for MCV<72.9 fL or in the presence of schizocytes, the hemogram validation procedure may incorporate the use of PLT-O.


Asunto(s)
Impedancia Eléctrica , Índices de Eritrocitos , Humanos , Índices de Eritrocitos/fisiología , Recuento de Plaquetas/métodos , Estudios Prospectivos , Femenino , Masculino , Anemia/diagnóstico , Anemia/sangre , Adulto , Anemia Hipocrómica/diagnóstico , Anemia Hipocrómica/sangre , Persona de Mediana Edad
5.
Clin Lab ; 70(5)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38747921

RESUMEN

BACKGROUND: Pseudothrombocytopenia (PTCP) can be caused by anticoagulants or pre-analytical issues. The authors present a case of PTCP attributed to pre-analytical issues in a 68-year-old male patient. METHODS: The platelet count results were obtained using both the impedance and fluorescence channels of Sysmex XN-10. The blood film was scanned using both Cellavision DM96 and a microscope. RESULTS: The flag for PLT-Clumps and the scattergram from the PLT-F channel indicated the presence of platelet aggregation. Fibrin could be observed at the feathered end of the blood film. A diagnosis of PTCP resulting from pre-analytical issues was made. CONCLUSIONS: The presence of fibrin in a blood film is a critical indicator for diagnosing PTCP due to pre-analytical issues.


Asunto(s)
Fibrina , Trombocitopenia , Humanos , Masculino , Anciano , Trombocitopenia/sangre , Trombocitopenia/diagnóstico , Fibrina/metabolismo , Fibrina/análisis , Recuento de Plaquetas/métodos , Anticoagulantes , Agregación Plaquetaria , Plaquetas
6.
Transfus Apher Sci ; 63(3): 103930, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38644062

RESUMEN

While there are various aspects of platelet biology that can be studied in the lab (i.e. adhesion, degranulation, integrin activation), the master test for platelet function is that which gives a measure of the platelet aggregation capacity upon stimulation with an agonist. Platelet function testing is necessary for the diagnosis of platelet disorders and the monitoring of patients receiving anti-platelet treatments. Furthermore, it becomes relevant in the quality control of platelet concentrates for transfusion purposes, especially considering the global concern about long term storage, other forms of storage (i.e. cryopreservation, lyophilization), and the impact of Pathogen Reduction Treatments (PRTs) on platelet performance upon transfusion. However, it has been acknowledged as technically difficult and demanding, since a fine platelet function test must be carried out under specific conditions. Still, there might be occasions that preclude the platelet function testing abiding to the gold standard requirements, thus, leaving us with the necessity to redefine which variables may condition or limit the analysis of platelet function testing. In the present manuscript, we test different variables (such as the anticoagulant used or the time elapsed since extraction) and the possibility to reconstitute blood prior to platelet function analysis. This study aims to provide windows of action at the diagnostics lab, especially when not all of the recommended procedures and conditions can be followed: for example, when a sample is sent from a long distance, when there is a limitation on blood extraction volume or when certain parameters (platelet count) preclude reliable test results.


Asunto(s)
Pruebas de Función Plaquetaria , Humanos , Pruebas de Función Plaquetaria/métodos , Pruebas de Función Plaquetaria/instrumentación , Recuento de Plaquetas/métodos , Plaquetas/metabolismo
7.
Transfusion ; 64 Suppl 2: S191-S200, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38566492

RESUMEN

INTRODUCTION: The VCM is a point-of-care analyzer using a new viscoelastometry technique for rapid assessment of hemostasis on fresh whole blood. Its characteristics would make it suitable for use in austere environments. The purpose of this study was to evaluate the VCM in terms of repeatability, reproducibility and interanalyzer correlation, reference values in our population, correlation with standard coagulation assays and platelet count, correlation with the TEG5000 analyzer and resistance to stress conditions mimicking an austere environment. METHODS: Repeatability, reproducibility, and interanalyzer correlation were performed on quality control samples (n = 10). Reference values were determined from blood donor samples (n = 60). Correlations with standard biological assays were assessed from ICU patients (n = 30) and blood donors (n = 60) samples. Correlation with the TEG5000 was assessed from blood donor samples. Evaluation of vibration resistance was performed on blood donor (n = 5) and quality control (n = 5) samples. RESULTS: The CVs for repeatability and reproducibility ranged from 0% to 11%. Interanalyzer correlation found correlation coefficients (r2) ranging from 0.927 to 0.997. Our reference values were consistent with those provided by the manufacturer. No robust correlation was found with conventional coagulation tests. The correlation with the TEG5000 was excellent with r2 ranging from 0.75 to 0.92. Resistance to stress conditions was excellent. CONCLUSION: The VCM analyzer is a reliable, easy-to-use instrument that correlates well with the TEG5000. Despite some logistical constraints, the results suggest that it can be used in austere environments. Further studies are required before its implementation.


Asunto(s)
Sistemas de Atención de Punto , Humanos , Sistemas de Atención de Punto/normas , Reproducibilidad de los Resultados , Valores de Referencia , Tromboelastografía/métodos , Tromboelastografía/instrumentación , Femenino , Masculino , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/instrumentación , Pruebas de Coagulación Sanguínea/normas , Recuento de Plaquetas/métodos , Recuento de Plaquetas/instrumentación , Donantes de Sangre
8.
Clin Lab ; 70(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38623668

RESUMEN

BACKGROUND: Platelet (PLT) count is one of the most important parameters of automated hematology, as spurious PLT reports could affect medical judgement and bring significant risks. In most cases, spurious PLT will not be reported for review criteria, which will be triggered by abnormal PLT histograms and PLT flag(s). Here, we present a case of severe aplastic anemia after hematopoietic stem cell transplantation with spurious high platelet count with normal histogram and no PLT flag(s). METHODS: The electrical impedance channel (PLT-I) and the fluorescence channel (PLT-F) of Sysmex XN-series hematology analyzer was used to obtain PLT results. Then, the sample was retested by another hematology analyzer MINDRAY BC-7500 [NR] CRP, and incubation was performed to rule out cryoglobulin interference. Furthermore, a microscope was used to estimate the PLT count by the ratio of platelets to red blood cells and observe the morphology of cells. RESULTS: Both PLT-I and PLT-F test results were spuriously high, and microscopically assessed platelet counts were relatively reliable. The observed spiny cells and ghost cells caused by hemolysis may have contributed to the inaccuracy of instrumental counting in this case. CONCLUSIONS: For special hematologic patients, PLT-I with flags may not be sufficient for screening purposes and PLT-F is not always accurate. Multiple testing methods including manual microscopy are needed.


Asunto(s)
Agmatina/análogos & derivados , Anemia Aplásica , Ácido Oxámico/análogos & derivados , Humanos , Recuento de Plaquetas/métodos , Anemia Aplásica/diagnóstico , Reproducibilidad de los Resultados , Plaquetas
9.
Clin Lab ; 70(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38469783

RESUMEN

BACKGROUND: The rapid development of automatic blood cell analyzers has greatly optimized complete blood count results. However, erroneous results relevant to automatic blood cell analyzers still exist. Pseudothrombocytopenia can be observed in both cases of anticoagulant-induced platelet aggregation, and the presence of large and giant platelets. METHODS: A rare case of a MYH9-related disorder, in which marked underestimation of platelet count was led by large and giant platelets using the impedance count by an automated hematology analyzer. Moreover, lancet-shaped and Dohle body-like cytoplasmic inclusions were detected in almost all white blood cells of the patient. RESULTS: The platelet count was done by an optical platelet counter or a fluorescence platelet counter, and peripheral blood smear was evaluated. In addition, the diagnosis of MYH9-related disorder was established by the molecular findings. CONCLUSIONS: Identification of the peripheral blood smear and familial history will eliminate the need for further laboratory testing and bone marrow examination.


Asunto(s)
Pérdida Auditiva Sensorineural , Trombocitopenia , Trombocitopenia/congénito , Humanos , Recuento de Plaquetas/métodos , Trombocitopenia/diagnóstico , Trombocitopenia/genética , Plaquetas , Pérdida Auditiva Sensorineural/diagnóstico , Cadenas Pesadas de Miosina/genética
10.
J Appl Lab Med ; 9(4): 833-847, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38549553

RESUMEN

BACKGROUND: The most ordered laboratory test worldwide is the complete blood count (CBC). CONTENT: In this primer, an introduction to platelet testing in the context of the CBC is provided with a discussion of the laboratory evaluation of platelet abnormalities including thrombocytopenia and thrombocytosis. SUMMARY: As clinical chemists continue to be tasked to direct laboratories outside of the traditional clinical chemistry sections such as hematology, expertise must be developed. This primer is dedicated to that effort.


Asunto(s)
Plaquetas , Trombocitopenia , Trombocitosis , Humanos , Trombocitosis/sangre , Trombocitosis/diagnóstico , Trombocitopenia/diagnóstico , Trombocitopenia/sangre , Recuento de Plaquetas/métodos , Recuento de Células Sanguíneas/métodos , Recuento de Células Sanguíneas/instrumentación , Química Clínica/métodos , Química Clínica/normas
11.
Cir Cir ; 92(1): 52-58, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537226

RESUMEN

OBJECTIVE: This study aimed to evaluate the value of platelet activation markers in predicting preeclampsia and its severity. Preeclampsia is a serious pregnancy complication that affects 3-5% of pregnancies and can lead to significant morbidity and mortality for both the mother and the fetus. METHODS: The study included 99 patients diagnosed with preeclampsia and 60 healthy pregnant women as a control group. Platelet activation markers such as mean platelet volume (MPV), platelet distribution width (PDW), platelet count, and plateletcrit were evaluated along with other clinical parameters. RESULTS: The results of the study showed that platelet activation markers, particularly PDW and MPV, are valuable in the diagnosis and follow-up of preeclampsia. However, they are not sufficient to predict the severity of the disease. CONCLUSION: The study suggests that platelet activation markers could aid in predicting, diagnosing, and managing preeclampsia. However, further research is needed to determine the role of these markers in predicting the severity of the disease. The findings of this study could contribute to the development of more effective strategies for the prevention and management of preeclampsia, which could ultimately improve maternal and fetal outcomes.


OBJETIVO: El estudio tuvo como objetivo determinar el valor de los marcadores de activación plaquetaria en la predicción de la preeclampsia y su gravedad. MÉTODO: Se incluyeron 99 pacientes diagnosticadas con preeclampsia, incluyendo 36 casos graves, y un grupo control de 60 mujeres embarazadas sanas. Se evaluaron diversas variables, como el volumen plaquetario medio, el recuento de plaquetas, el hematocrito plaquetario y la amplitud de distribución plaquetaria. RESULTADOS: Los resultados mostraron que el volumen plaquetario medio y la amplitud de distribución plaquetaria son parámetros valiosos en el diagnóstico y seguimiento de la preeclampsia, aunque no son suficientes para predecir su gravedad. El análisis estadístico reveló que la edad, el volumen plaquetario medio, la amplitud de distribución plaquetaria, la semana de gestación y los puntajes de Apgar al primer y quinto minuto fueron significativamente diferentes en el grupo de preeclampsia en comparación con el grupo control. CONCLUSIONES: En conclusión, estos resultados sugieren que los marcadores de activación plaquetaria pueden ser útiles para el diagnóstico y seguimiento de la preeclampsia, y que el volumen plaquetario medio y la amplitud de distribución plaquetaria, por ser parámetros económicos y accesibles, podrían ayudar a predecir, diagnosticar y manejar esta complicación durante el embarazo.


Asunto(s)
Preeclampsia , Complicaciones del Embarazo , Humanos , Femenino , Embarazo , Preeclampsia/diagnóstico , Volúmen Plaquetario Medio , Activación Plaquetaria , Recuento de Plaquetas/métodos
12.
Scand J Clin Lab Invest ; 84(2): 91-96, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38420711

RESUMEN

BACKGROUND: The Immature Platelet Fraction (IPF) is an indicator of thrombopoiesis which is a useful parameter in thrombocytopenia. It demonstrates compensatory mechanisms in production of platelets, but currently not implemented in routine clinical practice. The aim of this study was to establish the reproducibility and stability of IPF, for both percentage (%-IPF) and absolute (A-IPF) measurements.Material/methods: A total of 71 samples, of which 45 for reproducibility and 26 for stability analysis, were assayed for full blood count using the Sysmex XN-10 analyser at room temperature (RT:19-25 °C). For reproducibility analysis, IPF measurements were analysed 11 times by different appraisers using the same sample, while for stability analysis, IPF was measured over fourteen hourly-intervals up to 24 h (n = 21) and then separately extended beyond the point of stability to 72 h (n = 5). RESULTS: Reproducibility analysis of %-IPF and A-IPF (n = 45) showed very reliable results, with the range of mean CV% values between 1.25-8.90% and 1.70-9.96%, respectively. On the other hand, overall, stability analysis of %-IPF and A-IPF (n = 21) at RT over 24 h showed reliable results, with pooled mean CV% values of 1.32% and 1.43%, respectively, with no significant difference between %-IPF and A-IPF (p = 0.767 and p = 0.821). All %-IPF and A-IPF values had exceeded the set acceptance criterion of stability (CV% ≥ 10.0%) before 72 h. CONCLUSIONS: Overall, %-IPF and A-IPF reproducibility and storage at RT for 24 h predominantly demonstrates the suitability of their usage for testing on the Sysmex XN-series analysers.


Asunto(s)
Plaquetas , Humanos , Reproducibilidad de los Resultados , Plaquetas/citología , Recuento de Plaquetas/instrumentación , Recuento de Plaquetas/métodos , Trombocitopenia/sangre , Trombocitopenia/diagnóstico , Trombopoyesis/fisiología
13.
Clin Lab ; 70(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38345993

RESUMEN

BACKGROUND: In several situations, spurious results are observed in the use of hematology analyzers including pseudothrombocytosis caused by part of the cytoplasm of abnormal cells which was reported in leukemic blasts, monoblasts, or lymphoblasts. METHODS AND RESULTS: Here, we report a rare case of pseudothrombocytosis caused by mature leukocyte fragments associated with heatstroke. It was identified by the peripheral blood smear and obvious difference between the PLT-F (fluorescence) and I (impedance) channel. CONCLUSIONS: Observation of peripheral blood smears and determination on the PLT-F channel can identify this interference caused by leukocyte fragments in heatstroke.


Asunto(s)
Plaquetas , Golpe de Calor , Humanos , Recuento de Plaquetas/métodos , Leucocitos , Citoplasma , Golpe de Calor/complicaciones , Golpe de Calor/diagnóstico
14.
Arch Pathol Lab Med ; 148(1): 61-67, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37014982

RESUMEN

CONTEXT.­: Platelet (PLT) counting with impedance (PLT-I) is widely used but has low specificity. PLT counting with fluorescence (PLT-F), tested by the Sysmex XN series with high specificity, can be a complementary method to PLT-I. OBJECTIVE.­: To identify red blood cell (RBC)- and PLT-related parameters as potential influencing factors for PLT-I and establish PLT reflex test rules with PLT-F. DESIGN.­: We prospectively tested both PLT-I and PLT-F in all 3480 samples. In a development data set of 3000 samples, differences between the reflex and nonreflex groups were compared and influencing factors for PLT-I were identified by logistic regression. The area under the receiver operating characteristic (ROC) curve and cutoff values were obtained by ROC curve analysis. Validation was conducted in the remaining 480 samples (validation data set). RESULTS.­: PLT-F showed comparable results with immunoplatelet counting. In logistic regression, increased micro-RBC absolute count (micro-RBC#), fragmented RBC absolute count (FRC#), PLT distribution width (PDW), mean PLT volume (MPV), PLT-large cell ratio (P-LCR), and immature PLT fraction absolute count (IPF#) were influencing factors for PLT-I. In ROC curve analysis, the cutoff values of micro-RBC#, FRC#, PDW, MPV, and P-LCR were 0.64 × 106/µL, 0.082 × 106/µL, 15.40 fL, 11.15 fL, and 33.95%, respectively. The areas under the ROC curve of micro-RBC# and FRC# were 0.77 and 0.79, respectively. CONCLUSIONS.­: Micro-RBC#, FRC#, PDW, MPV, P-LCR, and IPF# were factors affecting PLT-I. Among them, micro-RBC# and FRC# were the most impactful factors. From our study results, micro-RBC#, FRC#, MPV, PDW, and P-LCR can be used to establish reflex test rules for PLT counting in clinical work.


Asunto(s)
Hematología , Volúmen Plaquetario Medio , Humanos , Recuento de Plaquetas/métodos , Impedancia Eléctrica , Plaquetas , Eritrocitos
15.
Int J Lab Hematol ; 46(1): 63-71, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37731006

RESUMEN

INTRODUCTION: The Atellica Hema (Siemens Healthineers, Tarrytown, NY, USA) is a new generation multi-parameter analyzer for full blood count, 6-part differential and reticulocyte testing by impedance variation and fluorescence flow cytometry. In this study, we verified the whole blood and limited body fluid modes of the Atellica Hema 580. METHODS: We evaluated precision, linearity, carry-over, throughput and performed a method comparison to assess the performance of the Atellica Hema 580. For comparison of the Atellica Hema 580 with the Sysmex XN-1000 (Sysmex, Kobe, Japan), 140 samples from adult and pediatric patients including both normal and abnormal hematology profiles were analyzed in parallel. RESULTS: The Atellica Hema 580 demonstrated acceptable imprecision within the manufacturer's specifications for whole blood and body fluid modes, good linearity for high and low ranges and no significant carryover. The full blood count, differential and reticulocyte correlated well with the Sysmex XN-1000, except for mean cell hemoglobin concentration, basophil and large immature cells. The optical platelet count, reflexed in 34 samples with a platelet count <150 × 109 /l, showed a strong correlation with the fluorescent platelet count on the Sysmex XN-1000. The morphology flagging efficiency was 92% for white blood cells, 95% for red blood cells and 87% for platelets. CONCLUSION: The Atellica Hema 580 showed good analytical performance and workflow efficiency for a wide range of patient samples.


Asunto(s)
Hematología , Adulto , Humanos , Niño , Recuento de Células Sanguíneas/métodos , Hematología/métodos , Recuento de Plaquetas/métodos , Leucocitos , Plaquetas , Reproducibilidad de los Resultados
16.
Clin Chem Lab Med ; 62(4): 690-697, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37855253

RESUMEN

OBJECTIVES: Automated hematology analysis is expected to improve the performance of platelet counting. We evaluated the performance of a new platelet counting, hybrid (PLT-H) and also impedance (PLT-I) and optical (PLT-O) on the BC-780 automated hematology analyzer compared to the international reference method (IRM) in blood samples with thrombocytopenic and platelet interference. METHODS: The basic platelet count performance of the BC-780 automated hematology analyzer was evaluated according to the requirements of the Clinical Laboratory and Standards Institute (CLSI) Document H26-A2. Additionally, the thrombocytopenic (low PLT count) blood samples and the platelet interference blood samples including fragmented red blood cells (RBCs), microcytes or small RBCs, and giant platelets were determined with the BC-780 hematology analyzer compared to the IRM. RESULTS: Blank counting and the carry-over contamination rate of platelet count using the BC-780 both met the manufacturers' claim. For both 123 thrombocytopenic and 232 platelet interference blood samples (72 fragmented RBCs, 91 microcytes and 51 giant platelets), all three platelet counting methods exhibited high comparability with the IRM (the lowest correlation (r)=0.916). Interestingly, the comparability of PLT-H (r=0.928-0.986) with the IRM was better than that of PLT-I (r=0.916-0.979). CONCLUSIONS: The performance of PLT-H in the BC-780 met the manufacturer's specifications. PLT-H exhibits better reproducibility than did PLT-I, correlates well with the PLT-O for thrombocytopenic samples and demonstrates good anti-interference ability. PLT-H counting is therefore recommended as a zero-cost alternative platelet counting method for platelet interference samples in clinical settings.


Asunto(s)
Agmatina/análogos & derivados , Hematología , Ácido Oxámico/análogos & derivados , Humanos , Recuento de Plaquetas/métodos , Reproducibilidad de los Resultados , Hematología/métodos , Plaquetas
17.
Lab Med ; 55(4): 439-441, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38156747

RESUMEN

OBJECTIVE: To compare platelet count results of specimens that yield platelet clump flags to platelet count results on these specimens after vortexing. METHOD: Specimens that generated platelet count flags on Sysmex XN 3000 instruments were vortexed and rerun. Only data from specimens demonstrating elimination of platelet clump flags were used in this study. Pearson r analysis was performed on data. RESULTS: Comparison of complete blood count results (white blood cell count, red blood cell count, hemoglobin, hematocrit, and platelet count) all yielded Pearson r scores >0.9. CONCLUSION: Additional patient comfort and safety concerns, as well as concerns over additional specimen collection and processing costs, may be avoided by vortexing and rerunning specimens flagged for platelet clumps when the platelet count is normal.


Asunto(s)
Ácido Edético , Humanos , Recuento de Plaquetas/métodos , Ácido Edético/química , Ácido Edético/farmacología , Manejo de Especímenes/métodos , Manejo de Especímenes/normas , Agregación Plaquetaria/fisiología , Plaquetas
18.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 31(6): 1820-1824, 2023 Dec.
Artículo en Chino | MEDLINE | ID: mdl-38071067

RESUMEN

OBJECTIVE: To investigate the changes of platelet count (PLT), plateletcrit (PCT), mean platelet volume (MPV) and platelet distribution width (PDW) before and after apheresis platelet transfusion, the correlation between the parameters and their clinical significance. METHODS: A total of 38 patients who received apheresis platelet transfusion were selected, their results of blood routine test closest to the time point of apheresis platelet transfusion were consulted from hospital information system and the changes of PLT, PCT, MPV and PDW were compared before and after transfusion. The correlation between above parameters was analyzed. The correlation of body mass index (BMI) with the increased multiple and increased value after platelet infusion was also analyzed. RESULTS: Compared with pre-infusion, PLT and PCT significantly increased (both P <0.001) while MPV and PDW showed no significant difference after apheresis platelet transfusion (P >0.05). The difference of PLT and PCT before and after apheresis platelet transfusion had no correlation with PLT and PCT before transfusion (r =0.002, r =0.001), while the difference of MPV and PDW was negatively correlated with MPV and PDW before transfusion (r =-0.462, r =-0.610). The PLT growth rate was positively correlated with PCT growth rate before and after apheresis platelet transfusion (r =0.819). BMI was positively correlated with the increased multiple of PLT after infusion (r =0.721), but not with the increased value of PLT after infusion (r =0.374). CONCLUSION: Apheresis platelet transfusion can cause platelet parameters change and shows different characteristics. Characteristic changes of platelet parameters and their correlation can be used as reference indices to evaluate the efficacy of apheresis platelet transfusion.


Asunto(s)
Eliminación de Componentes Sanguíneos , Volúmen Plaquetario Medio , Humanos , Transfusión de Plaquetas , Plaquetas , Recuento de Plaquetas/métodos
19.
Einstein (Sao Paulo) ; 21: eAO0501, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38126661

RESUMEN

OBJECTIVE: This study aimed to compare the hematological parameters released by hematological analyzers with those released in customer reports. METHODS: We conducted a descriptive study in the laboratories of a medium-sized municipality in the state of Minas Gerais registered in the National Register of Health Establishments. Interviews were conducted using a questionnaire to obtain information regarding the parameters released by the analyzers and those available in the customer's report. RESULTS: Sixteen laboratories were evaluated, and none of them released all the parameters obtained from the hematological analyzers to customers. The red blood cell distribution width was released in 88% of the laboratories, atypical lymphocytes in 70%, mean platelet volume in 50%, platelet distribution width and platelet count in 20%. No laboratory released information on reticulocytes, fraction of immature reticulocytes and immature granulocytes, nucleated erythrocyte count, immature platelet fraction and reticulocyte hemoglobin, and large platelet rate. CONCLUSION: All evaluated clinical analysis laboratories had at least one parameter that was not released in the customer's report despite being released by the hematological analyzers. The lack of knowledge on the part of professionals about the clinical importance of each parameter of the complete blood count results in a loss in patient assessment, and it is important to include these parameters in the complete blood count report.


Asunto(s)
Plaquetas , Índices de Eritrocitos , Humanos , Recuento de Células Sanguíneas/métodos , Recuento de Eritrocitos/métodos , Recuento de Plaquetas/métodos
20.
Platelets ; 34(1): 2287064, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38031975

RESUMEN

The hybrid-channel platelet counting method (PLT-H) is a new platelet counting technique proposed by Mindray of China. In this study, we aimed to evaluate the accuracy of this technique in various situations and its reliability in platelet transfusion decision-making. A total of 378 venous blood samples were tested. Using the immunological PLT counting method recommended by the International Council for Standardization in Hematology as the reference method (PLT-IRM), Passing-Bablok regression and Bland-Altman analysis were performed on the PLT-H results. The anti-interference performance of PLT-H under different interference levels was explored using intergroup comparisons, and confusion matrices were analyzed at various transfusion cutoff values. In the absence of interference, there was a strong correlation between PLT-H and PLT-IRM (r = 0.993, 95% CI: 0.990-0.996). Under various interference conditions, the correlation between PLT-H and PLT-IRM was between 0.963 and 0.992, with an average deviation of -14.56 to -2.02. The performance of PLT-H against interference did not change significantly with increasing levels of small RBCs, large PLTs, and RBC fragments (P = .5704, 0.0832, 0.9893). In low-value samples (PLT <100 × 109/L), the coefficient of variation (CV) for PLT-H was less than 7.6%, regardless of the presence or absence of interfering substances. In addition, there was a high agreement between PLT-H and PLT-IRM (ICC = 0.972). Confusion matrice analysis at each medical decision level showed similarity to methods using the fluorescence channel (PLT-O) and superiority to the impedance channel (PLT-I). Compared with PLT-I, PLT-H has higher accuracy in PLT counting, stronger anti-interference ability, better performance in low-value samples at no extra economic cost and can be more useful for platelet transfusion decision-making. PLT-H is a novel method for platelet counting that offers higher accuracy, providing physicians with the ability to make better medical decisions, particularly in cases where values are low, or interference is present. As it does not require additional reagents, it is highly likely to replace PLT-I and become the mainstream method for platelet counting in the future.


Asunto(s)
Plaquetas , Transfusión de Plaquetas , Humanos , Reproducibilidad de los Resultados , Recuento de Plaquetas/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA