RESUMEN
BACKGROUND: Transcatheter aortic valve implantation (TAVI) has had an exponential increase of its indication, being incorporated into the Brazilian Unified Public Health System in 2022, thus requiring assessment of its use in Brazil. OBJETICVE: To assess the factors associated with in-hospital mortality and non-fatal complications in both genders in the Brazilian Registry of Transcatheter Aortic Valve Implantation and New Technologies (RIBAC-NT) population. METHOD: Analysis of the RIBAC-NT database from 2008 to 2022 was performed. Logistic models and machine learning were used for statistical assessment of the association between variables and outcomes. The software R was used and a 5% significance level, adopted. RESULTS: Analysis of 2588 patients (women, 51.2%; in-hospital death, 8.2%). Mortality was associated with procedural complications, of which major vascular complication (VC) and acute kidney injury (AKI) stood out (p<0.001). Major VC occurred in 6% of the patients, with 34% mortality; AKI occurred in 8.8%, with 13% mortality, which increased up to 8 times when AKI coexisted with other complications. Non-fatal complications occurred in 50.5% of all patients, affecting 63% of those with 1st generation (1G) bioprosthesis and 39% of those with 2nd generation (2G) bioprosthesis (p<0,001). Non-femoral access and heart rhythm influenced non-fatal complications in patients with 1G prostheses, while complications in patients with 2G prosthesis associated with the female gender (39.6% vs. 30.4%, p=0.003). CONCLUSION: In-hospital mortality in the RIBAC-NT population was directly associated with procedural complications, mainly major VC and AKI. The occurrence of non-fatal complications differed according to gender and bioprosthesis type.
FUNDAMENTO: O implante valvar aórtico transcateter (TAVI) apresenta crescimento exponencial de suas indicações e foi incorporado ao Sistema Único de Saúde em 2022, sendo necessário avaliar seu uso no Brasil. OBJETIVO: Conhecer os fatores associados a mortalidade e complicações não fatais intra-hospitalares, em ambos os gêneros, na população do Registro Brasileiro de Implante de Bioprótese Aórtica por Cateter e Novas Tecnologias (RIBAC-NT). MÉTODO: Análise do banco de dados RIBAC-NT de 2008 a 2022. Aplicados modelos logísticos e machine learning na avaliação estatística da associação das variáveis com os desfechos, empregando o software R e nível de significância de 5%. RESULTADOS: Analisados 2.588 pacientes (mulheres, 51,2%; óbito intra-hospitalar, 8,2%). Mortalidade associou-se a complicações do procedimento, dentre elas destacam-se complicações vasculares (CV) maiores e insuficiência renal aguda (IRA) (p< 0,001). A CV maior ocorreu em 6%, com 34% de mortalidade; IRA ocorreu em 8,8%, com 13% de mortalidade, que aumentou até 8 vezes quando IRA coexistiu com outras complicações. Complicações não fatais ocorreram em 50,5% do total de pacientes, acometendo 63% daqueles com bioprótese de 1a geração (1G) e 39% daqueles com bioprótese de 2a geração (2G) p<0,001. O acesso não femoral e o ritmo cardíaco influenciaram as complicações não fatais nas próteses 1G, enquanto complicações das próteses 2G associaram-se ao gênero feminino (39,6% vs. 30,4%, p= 0,003). CONCLUSÃO: A mortalidade intra-hospitalar na população do RIBAC-NT associou-se diretamente a complicações do procedimento, principalmente CV maior e IRA. A ocorrência de complicações não fatais diferiu conforme o gênero e o tipo da bioprótese.
Asunto(s)
Mortalidad Hospitalaria , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Brasil/epidemiología , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Factores de Tiempo , Factores SexualesRESUMEN
BACKGROUNDS: The prognosis of the triglyceride-glucose (TyG) index, a validated surrogate marker for insulin resistance, in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains unknown. METHODS: This study consecutively enrolled patients diagnosed with severe AS who underwent TAVR in a Chinese tertiary hospital from March 2013 to September 2023. Participants were stratified based on the TyG index cut-off value. Cox proportional hazards regression models were utilized to explore the association between the TyG index and all-cause mortality, including an assessment of interactions between the TyG index and various covariates on mortality outcomes. RESULTS: Among 1045 patients (mean age 74.7 years, 58.2% male), there was 134 all-cause mortality, resulting in a crude mortality rate of 64.3 per 1000 person-years. Adjusting for age, sex, body mass index, smoking, hypertension, diabetes mellitus, bicuspid aortic valve, atrial fibrillation, Society of Thoracic Surgeons (STS) score, and left ventricular ejection fraction, a per-unit increase in the TyG index was associated with a 41% higher all-cause mortality risk (HR 1.41, 95% CI 1.03-1.93, p = 0.030). Notably, the relationship between the TyG index and all-cause mortality was significantly modified by age (pinteraction = 0.027), sex (pinteraction = 0.007), hypertension (pinteraction = 0.030), and STS score (pinteraction = 0.002). CONCLUSIONS: A higher TyG index is significantly associated with an increased risk of all-cause mortality in AS patients after TAVR. These results underscore the importance of considering the TyG index in the prognostic evaluation of AS patients following TAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Biomarcadores , Glucemia , Causas de Muerte , Reemplazo de la Válvula Aórtica Transcatéter , Triglicéridos , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Anciano , Medición de Riesgo , Glucemia/metabolismo , Anciano de 80 o más Años , Biomarcadores/sangre , Triglicéridos/sangre , Resultado del Tratamiento , Factores de Tiempo , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , China/epidemiología , Valor Predictivo de las Pruebas , Resistencia a la InsulinaRESUMEN
BACKGROUND: Large datasets of transcatheter aortic valve implantation (TAVI) for pure aortic valve regurgitation (PAVR) are scarce. AIMS: We aimed to report procedural safety and long-term clinical events (CE) in a contemporary cohort of PAVR patients treated with new-generation devices (NGD). METHODS: Patients with grade III/IV PAVR enrolled in the FRANCE-TAVI Registry were selected. The primary safety endpoint was technical success (TS) according to Valve Academic Research Consortium 3 criteria. The co-primary endpoint was defined as a composite of mortality, heart failure hospitalisation and valve reintervention at last follow-up. RESULTS: From 2015 to 2021, 227 individuals (64.3% males, median age 81.0 [interquartile range {IQR} 73.5-85.0] years, with EuroSCORE II 6.0% [IQR 4.0-10.9]) from 41 centres underwent TAVI with NGD, using either self-expanding (55.1%) or balloon-expandable valves (44.9%; p=0.50). TS was 85.5%, with a non-significant trend towards increased TS in high-volume activity centres. A second valve implantation (SVI) was needed in 8.8% of patients, independent of valve type (p=0.82). Device size was ≥29 mm in 73.0% of patients, post-procedure grade ≥III residual aortic regurgitation was rare (1.2%), and the permanent pacemaker implantation (PPI) rate was 36.0%. At 30 days, the incidences of mortality and reintervention were 8.4% and 3.5%, respectively. The co-primary endpoint reached 41.6% (IQR 34.4-49.6) at 1 year, increased up to 61.8% (IQR 52.4-71.2) at 4 years, and was independently predicted by TS, with a hazard ratio of 0.45 (95% confidence interval: 0.27-0.76); p=0.003. CONCLUSIONS: TAVI with NGD in PAVR patients is efficient and reasonably safe. Preventing the need for an SVI embodies the major technical challenge. Larger implanted valves may have limited this complication, outweighing the increased risk of PPI. Despite successful TAVI, PAVR patients experience frequent CE at long-term follow-up.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Factores de Riesgo , FranciaRESUMEN
BACKGROUND: Research on the role of transcatheter heart valve (THV) deformation and calcium distribution in patients with bicuspid aortic valves (BAVs) undergoing transcatheter aortic valve replacement (TAVR) remains limited. OBJECTIVES: The aim of this study was to evaluate the impact of THV deformation on clinical outcomes in individuals with BAVs undergoing TAVR and the influence of calcium on these outcomes. METHODS: In total, 229 consecutive patients with BAVs who underwent TAVR with balloon-expandable valves and had computed tomography (CT) performed 30 days post-TAVR were analyzed. Patients were stratified into 3 groups: group 1 (n = 125), with no THV underexpansion or eccentricity; group 2 (n = 69), with underexpansion or eccentricity; and group 3 (n = 35), with both. Calcium distribution was assessed using CT, and its associations with clinical outcomes, including all-cause mortality at 3 years and leaflet thrombosis at 30 days, were determined. A subgroup analysis of patients with type 1 BAVs was conducted. RESULTS: Group 3 exhibited higher rates of all-cause mortality than the other groups, along with the highest risk for hypoattenuated leaflet thickening at 30 days. Multivariate analysis identified annular and left ventricular outflow tract calcification as independent predictors of all-cause mortality and hypoattenuated leaflet thickening. In patients with type 1 BAVs, excessive calcification at the raphe and opposite leaflet were associated with all-cause mortality at 3 years. CONCLUSIONS: THV deformation post-TAVR was significantly linked to all-cause mortality in patients with BAVs. Annular and left ventricular outflow tract calcification correlated with increased risks for all-cause mortality and leaflet thrombosis. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342).
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Calcinosis/mortalidad , Valvuloplastia con Balón/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/etiología , Tomografía Computarizada Multidetector , Valor Predictivo de las PruebasRESUMEN
BACKGROUND: Fluid overload (FO) subjects patients with severe aortic stenosis (AS) to increased risk for heart failure and death after valve replacement and can be objectively quantified using bioimpedance spectroscopy (BIS). OBJECTIVES: The authors hypothesized that in AS patients with concomitant FO, BIS-guided decongestion could improve prognosis and quality of life following transcatheter aortic valve replacement (TAVR). METHODS: This randomized, controlled trial enrolled 232 patients with severe AS scheduled for TAVR. FO was defined using a portable whole-body BIS device according to previously established cutoffs (≥1.0 L and/or ≥7%). Patients with FO (n = 111) were randomly assigned 1:1 to receive BIS-guided decongestion (n = 55) or decongestion by clinical judgment alone (n = 56) following TAVR. Patients without FO (n = 121) served as a control cohort. The primary endpoint was the composite of hospitalization for heart failure and/or all-cause death at 12 months. The secondary endpoint was the change from baseline to 12 months in the Kansas City Cardiomyopathy Questionnaire. RESULTS: The occurrence of the primary endpoint at 12 months was significantly lower in the BIS-guided vs the non-BIS-guided decongestion group (7/55 [12.7%, all deaths] vs 18/56 [32.1%, 9 hospitalizations for heart failure and 9 deaths]; HR: 0.36; 95% CI: 0.15-0.87; absolute risk reduction = -19.4%). Outcomes in the BIS-guided decongestion group were identical to the euvolemic control group (log-rank test, P = 0.7). BIS-guided decongestion was also associated with a higher increase in the Kansas City Cardiomyopathy Questionnaire score from baseline compared to non-BIS-guided decongestion (P = 0.001). CONCLUSIONS: In patients with severe AS and concomitant FO, quantitatively guided decongestive treatment and associated intensified management post-TAVR was associated with improved outcomes and quality of life compared to decongestion by clinical judgment alone. (Management of Fluid Overload in Patients Scheduled for Transcatheter Aortic Valve Replacement [EASE-TAVR]; NCT04556123).
Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Calidad de Vida , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Factores de Tiempo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Espectroscopía Dieléctrica , Desequilibrio Hidroelectrolítico/fisiopatología , Desequilibrio Hidroelectrolítico/terapia , Desequilibrio Hidroelectrolítico/diagnóstico , Desequilibrio Hidroelectrolítico/mortalidad , Desequilibrio Hidroelectrolítico/etiología , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Recuperación de la Función , Estudios ProspectivosRESUMEN
BACKGROUND: Asymmetrical expansion of transcatheter heart valves (THVs), manifesting as stent frame deformation, is an occasional fluoroscopic finding in transcatheter aortic valve replacement (TAVR). OBJECTIVES: The aim of this study was to investigate the impact of asymmetrical expansion of balloon-expandable THVs on hemodynamic valve performance and clinical outcomes. METHODS: In a prospective registry, TAVR asymmetry index was measured using freeze-frame fluoroscopic images and was defined as the ratio of THV heights: [(longer height/shorter height) - 1] × 100. THV hemodynamic performance was measured using echocardiography before hospital discharge. Impaired hemodynamic valve performance was defined as a mean residual THV gradient ≥20 mm Hg and/or moderate or greater paravalvular regurgitation. RESULTS: Among 1,216 patients undergoing transfemoral TAVR for native severe aortic valve stenosis with contemporary balloon-expandable THVs between February 2014 and June 2022, asymmetry index was an excellent predictor of impaired hemodynamic valve performance (area under the receiver-operating characteristic curve: 0.88; 95% CI: 0.84-0.92; P < 0.001). The optimal asymmetry index threshold for predicting impaired THV performance was >5.5% (sensitivity 77%, specificity 86%) and occurred in 17% of patients. Higher asymmetry index, as a continuous variable, was associated with impaired hemodynamic valve performance independent of total aortic valve calcium, bicuspid anatomy, balloon-expandable valve prosthesis type or size, and Society of Thoracic Surgeons Predicted Risk of Mortality score (OR: 1.37; 95% CI: 1.29-1.46; P < 0.001). High TAVR asymmetry index was not associated with all-cause mortality during a median of 376 days of follow-up (HR: 1.00; 95% CI: 0.71-1.41; P = 0.989). CONCLUSIONS: Asymmetrical expansion of balloon-expandable THVs was associated with impaired hemodynamic valve performance but not with clinical outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Anciano , Factores de Riesgo , Factores de Tiempo , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Recuperación de la Función , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiologíaRESUMEN
PURPOSE: This study aimed to compare the clinical outcomes of isolated surgical aortic valve replacement (SAVR) and transfemoral (TF)-transcatheter aortic valve replacement (TAVR) in low-risk aortic stenosis (AS) patients. METHODS: A total of 696 low-risk (Society of Thoracic Surgeons score <4%) AS patients underwent isolated SAVR or TF-TAVR at five centers. After 1:1 propensity score matching, 159 pairs were identified. Early and follow-up events, including cardiac mortality and major adverse cardiac and cerebrovascular events (MACCE: all-cause mortality, heart failure admission, reoperation, prosthetic valve endocarditis, and stroke), were compared. RESULTS: Baseline characteristics are similar between the matched groups. There were no 30-day cardiac mortalities in either group. All-cause mortality and MACCE at 30 days did not differ. During 5-year follow-up (median 3.1 [range 0-7.2] years), the incidence of cardiac mortality (1.3% vs. 18.9%; adjusted hazard ratio [aHR], 8.89; 95% confidence interval [CI], 2.68-29.53; P <0.001), all-cause mortality (4.2% vs. 33.9%; aHR, 8.56; 95% CI, 3.41-21.45; P <0.001), and MACCE (25.1% vs. 47.0%; aHR, 2.36; 95% CI, 1.54-3.63; P <0.001) were lower in the SAVR group than in the TAVR group. CONCLUSIONS: Isolated SAVR demonstrated better outcomes in low-risk AS patients. TAVR in this subset should be chosen carefully.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Masculino , Femenino , Factores de Tiempo , Anciano , Resultado del Tratamiento , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Medición de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Estudios Retrospectivos , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/etiología , Anciano de 80 o más Años , Puntaje de Propensión , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Estimación de Kaplan-Meier , Persona de Mediana EdadRESUMEN
BACKGROUND: There is a paucity of data regarding the relationship between overall hospital volumes for total aortic valve replacement (AVR; transcatheter AVR [TAVR] or surgical AVR [SAVR]) and patient outcomes. METHODS AND RESULTS: We queried the 2019 Nationwide Readmission Database for patients undergoing AVR. Based on procedural volumes of TAVR or SAVR, we classified hospitals as high (≥50th percentile) or low (<50th percentile) volume centers and categorized hospitals as high TAVR/high SAVR, high TAVR/low SAVR, high SAVR/low TAVR, and low TAVR/low SAVR. Multivariable regression models were employed. The main study outcomes were in-hospital mortality and 30-day readmission after total AVR. Our final analysis included 72 123 patients undergoing AVR at 400 hospitals across the United States. The median (interquartile range) hospital procedural volumes for total AVR, TAVR, and SAVR were 137 (86-210), 82 (50-127), and 56 (31-87) procedures, respectively. There was an inverse correlation between hospital procedural volumes of AVR, TAVR, or SAVR and in-hospital mortality after total AVR but not with 30-day readmission. Using high TAVR/high SAVR hospitals as reference, there was higher in-hospital mortality after total AVR among low TAVR/low SAVR hospitals (adjusted odds ratio [OR], 1.29 [95% CI, 1.07-1.56]) but similar in-hospital mortality among high TAVR/low SAVR hospitals and low TAVR/high SAVR volumes. There was no difference in 30-day readmission rates after total AVR among the 4 hospital categories. CONCLUSIONS: Nationwide data revealed that in-hospital mortality after total AVR (SAVR or TAVR) is inversely related to hospital total volumes of AVR. Patients with aortic stenosis have better outcomes if they are managed among experienced centers with high case volumes of both TAVR and SAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Mortalidad Hospitalaria , Hospitales de Alto Volumen , Hospitales de Bajo Volumen , Readmisión del Paciente , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estados Unidos/epidemiología , Anciano de 80 o más Años , Readmisión del Paciente/estadística & datos numéricos , Hospitales de Alto Volumen/estadística & datos numéricos , Hospitales de Bajo Volumen/estadística & datos numéricos , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/cirugía , Estudios Retrospectivos , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Bases de Datos Factuales , Medición de Riesgo/métodosAsunto(s)
Inteligencia Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Resultado del Tratamiento , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.
Asunto(s)
Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Humanos , Masculino , Femenino , Factores de Tiempo , Resultado del Tratamiento , Anciano , Factores de Riesgo , Estados Unidos , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Medición de Riesgo , Hemodinámica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Recuperación de la Función , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidadRESUMEN
BACKGROUND: The triglyceride glucose (TyG) index, as a reliable marker of insulin resistance, is associated with the incidence and poor prognosis of various cardiovascular diseases. However, the relationship between the TyG index and clinical outcomes in patients with severe aortic stenosis (AS) who underwent transcatheter aortic valve replacement (TAVR) remains unclear. METHODS: This study consecutively enrolled 1569 patients with AS underwent TAVR at West China Hospital of Sichuan University between April 2014 and August 2023. The outcomes of interest included all-cause mortality, cardiovascular mortality, and major adverse cardiovascular events (MACE). Multivariate adjusted Cox regression and restricted cubic splines (RCS) regression analyses were used to assess the associations between the TyG index and the clinical outcomes. The incremental prognostic value of the TyG index was further assessed by the time-dependent Harrell's C-index, integrated discrimination improvement (IDI) and the net reclassification improvement (NRI). RESULTS: During a median follow-up of 1.09 years, there were 146, 70, and 196 patients experienced all-cause death, cardiovascular death, and MACE, respectively. After fully adjusting for confounders, a per-unit increase of TyG index was associated with a 441% (adjusted HR: 5.41, 95% CI: 4.01-7.32), 385% (adjusted HR: 4.85, 95% CI: 3.16-7.43), and 347% (adjusted HR: 4.47, 95% CI: 3.42-5.85) higher risk of all-cause mortality, cardiovascular mortality and MACE, respectively. The RCS regression analyses revealed a linear association between TyG index and endpoints (all P for non-linearity > 0.05) with 8.40 as the optimal binary cutoff point. Furthermore, adding TyG index to the basic risk model provided a significant incremental value in predicting poor prognosis (Time-dependent Harrell's C-index increased for all the endpoints; All-cause mortality, IDI: 0.11, P < 0.001; NRI: 0.32, P < 0.001; Cardiovascular mortality, IDI: 0.043, P < 0.001; NRI: 0.37, P < 0.001; MACE, IDI: 0.092, P < 0.001; NRI: 0.32, P < 0.001). CONCLUSIONS: In patients with severe AS receiving TAVR, there was a positive linear relationship between TyG index and poor prognosis, with 8.4 as the optimal bivariate cutoff value. Our findings suggest TyG index holds potential value for risk stratification and guiding therapeutic decisions in patients after TAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Biomarcadores , Glucemia , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Triglicéridos , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano , Medición de Riesgo , Factores de Riesgo , Anciano de 80 o más Años , Factores de Tiempo , Resultado del Tratamiento , China/epidemiología , Biomarcadores/sangre , Glucemia/metabolismo , Triglicéridos/sangre , Causas de Muerte , Resistencia a la InsulinaRESUMEN
BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Ataque Isquémico Transitorio , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Factores de Riesgo , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Incidencia , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano de 80 o más Años , Factores de Tiempo , Medición de Riesgo , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/mortalidad , Ataque Isquémico Transitorio/epidemiología , Resultado del Tratamiento , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Delirio/epidemiología , Delirio/etiología , Delirio/diagnóstico , Delirio/mortalidad , Bases de Datos Factuales , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagenRESUMEN
BACKGROUND: Tricuspid regurgitation (TR) is associated with worse clinical outcomes after transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (M-TEER), but little is known about its association with health status outcomes. OBJECTIVES: The aims of this study were to explore, using the Society of Thoracic Surgeons and American College of Cardiology TVT (Transcatheter Valve Therapy) Registry, the association between baseline TR and health status after TAVR and M-TEER and to determine if baseline TR was associated with clinical endpoints. METHODS: Health status was assessed using Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score in patients enrolled in the TVT Registry who underwent isolated TAVR or M-TEER between January 2019 and June 2021. The association among baseline TR and KCCQ-OS score, being alive and well, and clinical outcomes was examined. RESULTS: In total, 130,097 TAVR patients (13.1% with moderate TR, 2.3% with severe TR) and 19,593 M-TEER patients (33.2% with moderate TR, 14.7% with severe TR) were included. Mean KCCQ-OS scores were lower with severe vs moderate vs none to mild TR at baseline prior to TAVR (39.4 ± 24.2 vs 45.2 ± 24.7 vs 51.3 ± 25.3; P < 0.01) or M-TEER (38.1 ± 23.9 vs 41.9 ± 24.7 vs 45.4 ± 25.2; P < 0.01) and similarly at 30 days and 1 year. The odds of being alive and well at 1 year were lower with moderate or severe TR before TAVR (adjusted OR: 0.79 [95% CI: 0.74-0.85] and adjusted OR: 0.81 [95% CI: 0.70-0.94], respectively) and severe TR before M-TEER (adjusted OR: 0.53; 95% CI: 0.40-0.71). Furthermore, moderate or severe TR before TAVR was associated with higher 1-year mortality and readmission, whereas moderate or severe TR before M-TEER was associated with higher 1-year mortality. CONCLUSIONS: In a large cohort of U.S. patients who underwent TAVR or M-TEER, greater baseline TR was associated with worse health status and clinical outcomes. Understanding adverse outcomes of TR in patients with coexisting valvular abnormalities is important, especially with rapidly evolving transcatheter tricuspid valve interventions.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estado de Salud , Válvula Mitral , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Femenino , Masculino , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Estados Unidos , Medición de Riesgo , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Índice de Severidad de la Enfermedad , Recuperación de la Función , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidadRESUMEN
BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Mortalidad Hospitalaria , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Estados Unidos/epidemiología , Factores de Riesgo , Factores de Tiempo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Medición de Riesgo , Prevalencia , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Estudios Retrospectivos , Centers for Medicare and Medicaid Services, U.S. , HemodinámicaRESUMEN
BACKGROUND: Cerebrovascular events remain one of the most devastating complications of transcatheter aortic valve implantation (TAVI). Data from real-world contemporary cohorts on longitudinal trends and outcomes remain limited. The aim of this study was to assess incidence, temporal trends, predictors, and outcomes of cerebrovascular events following transfemoral TAVI. METHODS AND RESULTS: The CENTER2 (Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves Versus Self-Expandable Valves 2) study includes patients undergoing TAVI between 2007 and 2022. The database contains pooled patient-level data from 10 clinical studies. A total of 24 305 patients underwent transfemoral TAVI (mean age 81.5±6.7 years, 56% women, median Society of Thoracic Surgeon Predicted Risk of Mortality 4.9% [3.1%-8.5%]). Of these patients, 2.2% (n=534) experienced stroke in the first 30 days after TAVI, and 40 (0.4%) had a transient ischemic attack. Stroke rates remained stable during the treatment period (2007-2010: 2.1%, 2011-2014: 2.5%, 2015-2018: 2.1%, 2019-2022: 2.1%; Ptrend=0.28). Moreover, 30-day cerebrovascular event rates were similar across Society of Thoracic Surgeon Predicted Risk of Mortality risk categories: 2.1% in low-risk, 2.6% in intermediate-risk, and 2.5% in high-risk patients (P=0.21). Mortality was higher in patients with 30-day stroke than without at 30 days (20.3% versus 4.7%; odds ratio, 5.1 [95% CI, 4.1-6.5]; P<0.001) and at 1 year (44.1% versus 15.0%; hazard ratio, 3.5 [95% CI, 3.0-4.2]; P<0.001). One-year mortality rates for stroke did not decline over time (2007-2010: 46.9%, 2011-2014: 46.0%, 2015-2018: 43.0%, 2019-2022: 39.1%; Ptrend=0.32). At 1 year, 7.0% of patients undergoing TAVI had a stroke. CONCLUSIONS: In 24 305 patients who underwent transfemoral TAVI, 30-day cerebrovascular event incidence remained ≈ 2.2% between 2007 and 2022. Thirty-day stroke rates were similar throughout Society of Thoracic Surgeon Predicted Risk of Mortality risk categories. Mortality rates after stroke remain high. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03588247.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Arteria Femoral , Incidencia , Ataque Isquémico Transitorio/epidemiología , Ataque Isquémico Transitorio/etiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/etiología , Medición de Riesgo/métodos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
BACKGROUND: Transthyretin amyloid cardiomyopathy (ATTR-CM) can manifest as rhythm disorders, heart failure, but also valvular degeneration. Despite aortic stenosis (AS) being prevalent among the elderly, data on ATTR-CM prevalence and outcome in patients with AS undergoing transaortic valve implantation (TAVI) remain scarce. AIM: To determine ATTR-CM prevalence and evaluate 1-year survival in patients undergoing TAVI. METHODS: Between December 2020 and September 2021, 100 consecutive patients underwent TAVI and were screened prospectively for ATTR-CM using bone scintigraphy (BS). Monoclonal gammopathy was ruled out in case of cardiac uptake on BS. All patients were followed prospectively for 1year after TAVI. RESULTS: The proportion of patients aged≥75years or with a EuroSCORE II>8% and possible femoral access was 99%. The abnormal cardiac uptake rate on BS was 7% (95% confidence interval: 2-12%); 86% of these patients were male. The RAISE (remodelling, age, injury, system and electrical) score, indicative of ATTR-CM risk, was higher in case of positive BS (P=0.04). Patients with positive BS were older and exhibited wider QRS complexes on electrocardiography (P=0.003), a higher frequency of reduced LVEF (57% vs. 17%), impaired basal LV strain (P=0.02) and a lower voltage/mass ratio (P=0.01). History of pacemaker implantation before TAVI was higher in the positive BS group (P=0.0004) and remained the only statistically significant factor after adjustment using the Holm-Bonferroni method. One-year survival of patients with positive BS did not differ from that of patients with isolated AS. CONCLUSIONS: Prevalence of ATTR-CM in patients treated with TAVI, underscoring the need for continued surveillance for potential development of ATTR-CM after TAVI. Caution is warranted regarding the 1-year survival because of the lack of study power. Further investigations are needed to define long-term prognosis of AS with ATTR-CM.
Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Cardiomiopatías , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/epidemiología , Masculino , Femenino , Prevalencia , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano de 80 o más Años , Factores de Tiempo , Resultado del Tratamiento , Neuropatías Amiloides Familiares/mortalidad , Neuropatías Amiloides Familiares/epidemiología , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/cirugía , Neuropatías Amiloides Familiares/diagnóstico , Factores de Riesgo , Estudios Prospectivos , Cardiomiopatías/mortalidad , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Cardiomiopatías/epidemiología , Medición de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatologíaRESUMEN
BACKGROUND: Obesity paradox in cardiovascular risk prediction has gained increasing attention in recent years. We aimed to investigate the impact of BMI on mortality following transcatheter aortic valve replacement (TAVR). METHODS: We performed a multi-center retrospective analysis of patients with severe aortic stenosis undergoing TAVR. Patients were categorized into: Underweight (BMI < 18.5), normal weight (18.5 ≤ BMI < 25), overweight (25 ≤ BMI < 30) and obese (BMI ≥ 30). Multivariate cox-proportional hazard model was used to compare all-cause mortality. RESULTS: Total of 6688 patients included (175 underweight, 2252 normal weight, 2368 overweight and 1893 with obesity). Mean age of patients was 81 ± 8 years with 55% males. Patients with obesity had higher prevalence of comorbidities but a lower overall STS score. Mortality at 30-days post-TAVR was lower in the obese population compared to underweight, normal weight, and overweight patients (1.6% vs. 6.9%, 3.6%, and 2.8%, respectively, p < 0.001). Similarly, 3-year mortality was lowest in patients with obesity (17.1% vs. 28.9%, 24.5% and 18.6%, respectively, p < 0.001). On multivariate analysis, long term all-cause mortality at 3-years remained significantly lower in patients with obesity compared to underweight (HR 1.74, 95% CI: 1.30-2.40, p < 0.001) and normal weight (HR: 1.41, 95% CI:1.21-1.63, p < 0.001) but not in overweight patients (HR: 1.10, 95% CI:0.94-1.28, p = 0.240). CONCLUSION: In conclusion, patients with obesity have improved short and long term mortality following TAVR with an observed progressive increase in mortality with lower BMI ranges.
Asunto(s)
Estenosis de la Válvula Aórtica , Índice de Masa Corporal , Obesidad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estudios Retrospectivos , Anciano de 80 o más Años , Anciano , Obesidad/complicaciones , Factores de Riesgo , Comorbilidad , Delgadez/complicaciones , Delgadez/mortalidad , Medición de Riesgo , Prevalencia , Resultado del Tratamiento , Paradoja de la ObesidadRESUMEN
BACKGROUND: Balloon aortic valvuloplasty (BAV) has gained renewed interest as a bridge to transcatheter aortic valve replacement (TAVR) for patients with aortic stenosis (AS). However, it is unclear whether they patients should undergo TAVR directly or receive a staged bridge to BAV before TAVR is unclear. We used a national database to examine the association between BAV and TAVR in patients with TAVR and its effect on in-hospital mortality. METHODS: Using the nationwide inpatient database of the Japanese registry of all cardiac and vascular diseases and the combination of the diagnosis procedure combination, we retrospectively analyzed 27,600 patients with AS who underwent TAVR between October 2013 and March 2021. Outcomes of the direct TAVR group (n = 27,387) were compared with those of the BAV bridge to TAVR group (n = 213), which received BAV at least 1 day before TAVR. RESULTS: The median age was 85 (interquartile range: 82-88) years, with 33.3% (n = 9188) being male. Unplanned/emergent admissions increased with TAVR, whereas the use of BAV bridge to TAVR decreased. The in-hospital mortality rate was 1.3% and decreased over time. However, the BAV bridge to TAVR had a significantly higher in-hospital mortality than direct TAVR (5.6% vs. 1.3%; p < .0001). Factors associated with in-hospital mortality included age, body mass index, chronic renal disease, percutaneous coronary intervention, and BAV bridge to TAVR. CONCLUSIONS: In unplanned/emergent and planned admission settings, the in-hospital mortality rate for BAV bridge to TAVR is worse than that for direct TAVR. Practical criteria for BAV bridge to TAVR should be proposed to improve outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Mortalidad Hospitalaria , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Masculino , Femenino , Mortalidad Hospitalaria/tendencias , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estudios Retrospectivos , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/tendencias , Anciano , Japón/epidemiologíaRESUMEN
OBJECTIVE: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Hemodinámica , Puntaje de Propensión , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Hemodinámica/fisiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Resultado del Tratamiento , Procedimientos Quirúrgicos sin Sutura/métodos , Prótesis Valvulares Cardíacas , Estudios Retrospectivos , Complicaciones Posoperatorias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de RiesgoRESUMEN
OBJECTIVE: To compare long-term cardiovascular (CV) outcomes between men and women with aortic stenosis (AS) undergoing aortic valve replacement (AVR) by the type of valve implant. METHODS: The study population consisted of 14 123 non-selected patients with AS undergoing first-time AVR and included in the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies (SWEDEHEART) registry during 2008-2016. Comparisons were made between men and women and type of valve implant (ie, surgical implantation with a mechanical (mSAVR) (n=1 966) or biological valve (bioSAVR) (n=9 801)) or by a transcatheter approach (TAVR) (n=2 356). Outcomes included all-cause mortality, ischaemic stroke, major bleeding, thromboembolic events, heart failure and myocardial infarction, continuously adjusted for significant comorbidities and medical treatment. RESULTS: In the mSAVR cohort, there were no significant sex differences in any CV events. In the bioSAVR cohort, a higher risk of death (HR: 1.14; 95% CI: 1.04 to 1.26, p=0.007) and major bleeding (HR: 1.41; 95% CI: 1.18 to 1.69, p<0.001) was observed in men. In the TAVR cohort, men suffered a higher risk of death (HR: 1.24; 95% CI: 1.07 to 1.45, p=0.005), major bleeding (HR: 1.35; 95% CI: 1.00 to 1.82, p=0.022) and thromboembolism (HR: 1.35, 95% CI: 1.00 to 1.82, p=0.047). CONCLUSION: No significant long-term difference in CV events was noted between men and women undergoing AVR with a mechanical aortic valve. In both the bioSAVR and TAVR cohort, mortality was higher in men who also had an increased incidence of several other CV events.