Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.549
Filtrar
1.
Opt Express ; 32(11): 20194-20206, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38859135

RESUMEN

In this work, a common-path optical coherence tomography (OCT) system is demonstrated for characterizing the tissue in terms of some optical properties. A negative axicon structure chemically etched inside the fiber tip is employed as optical probe in the OCT. This probe generates a quality Bessel beam owning a large depth-of-field, ∼700 µm and small central spot size, ∼3 µm. The OCT system is probing the sample without using any microscopic lens. For experimental validation, the OCT imaging of chicken tissue has been obtained along with estimation of its refractive index and optical attenuation coefficient. Afterwards, the cancerous tissue is differentiated from the normal tissue based on the OCT imaging, refractive index, and optical attenuation coefficient. The respective tissue samples are collected from the human liver and pancreas. This probe could be a useful tool for endoscopic or minimal-invasive inspection of malignancy inside the tissue either at early-stage or during surgery.


Asunto(s)
Pollos , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/instrumentación , Humanos , Animales , Diseño de Equipo , Hígado/diagnóstico por imagen , Hígado/patología , Páncreas/diagnóstico por imagen , Refractometría
2.
Molecules ; 29(12)2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38930876

RESUMEN

In this study, we report the successful development of a novel high-sensitivity intensity-based Surface Plasmon Resonance imaging (SPRi) biosensor and its application for detecting molecular interactions. By optimizing the excitation wavelength and employing a wavelength division multiplexing (WDM) algorithm, the system can determine the optimal excitation wavelength based on the initial refractive index of the sample without adjusting the incidence angle. The experimental results demonstrate that the refractive index resolution of the system reaches 1.77×10-6 RIU. Moreover, it can obtain the optimal excitation wavelength for samples with an initial refractive index in the range of 1.333 to 1.370 RIU and accurately monitor variations within the range of 0.0037 RIU without adjusting the incidence angle. Additionally, our new SPRi technique realized real-time detection of high-throughput biomolecular binding processes, enabling analysis of kinetic parameters. This research is expected to advance the development of more accurate SPRi technologies for molecular interaction analysis.


Asunto(s)
Técnicas Biosensibles , Resonancia por Plasmón de Superficie , Resonancia por Plasmón de Superficie/métodos , Técnicas Biosensibles/métodos , Algoritmos , Refractometría , Ensayos Analíticos de Alto Rendimiento/métodos , Cinética
3.
Acta Vet Hung ; 72(2): 116-124, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38935432

RESUMEN

In this study, we aimed to determine the quality of colostrum in sheep by using Brix refractometer. The research included 100 sheep of Merino X Kivircik crossbred. From each, we collected 15 mL of colostrum samples in falcon tubes within the first 8 h after delivery. Mean colostral IgG level of sheep was 156.68 ± 7.23 g L-1, optical and digital Brix refractometer values (%) were determined as 27.43 ± 0.53 and 27.69 ± 0.60, respectively. Ewes carrying twin lambs produced significantly higher quality colostrum than those carrying single lambs. However, parity did not affect the colostrum quality. Optical and digital Brix values were correlated with gold standard radial immunodiffusion (RID) colostral IgG level (r = 0.70 and r = 0.64, respectively). Also, optical and digital Brix refractometers were found to be highly correlated (r = 0.98, P < 0.001). While the optimal Brix value was 22% for the 50, 60 and 70 g L-1 IgG threshold values (by means of RID as the potential good quality threshold value for ewe colostrum quality), this value was 23% for 80 g L-1. We can conclude that Brix refractometers is a valuable tool for determining ewe colostrum quality. A cut point of 22% Brix for defining good quality colostrum in ewes was most appropriate for our data.


Asunto(s)
Calostro , Refractometría , Animales , Calostro/química , Ovinos , Refractometría/veterinaria , Refractometría/instrumentación , Femenino , Inmunoglobulina G/análisis , Inmunoglobulina G/sangre
4.
ACS Appl Mater Interfaces ; 16(25): 32516-32523, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38867603

RESUMEN

Plasmonic metamaterials have opened new avenues in medical diagnostics. However, the transfer of the technology to the markets has been delayed due to multiple challenges. The need of bulky optics for signal reading from nanostructures patterned on submillimeter area limits the miniaturization of the devices. The use of objective-free optics can solve this problem, which necessitates large area patterning of the nanostructures. In this work, we utilize laser interference lithography (LIL) to pattern nanodisc-shaped metamaterial absorber nanoantennas over a large area (4 cm2) within minutes. The introduction of a sacrificial layer during the fabrication process enables an inverted hole profile and a well-controlled liftoff, which ensures perfectly defined uniform nanopatterning almost with no defects. Furthermore, we use a macroscopic reflection probe for optical characterization in the near-IR, including the detection of the binding kinematics of immunologically relevant proteins. We show that the photonic quality of the plasmonic nanoantennas commensurates with electron-beam-lithography-fabricated ones over the whole area. The refractive index sensitivity of the LIL-fabricated metasurface is determined as 685 nm per refractive index unit, which demonstrates ultrasensitive detection. Moreover, the fabricated surfaces can be used multiple times for biosensing without losing their optical quality. The combination of rapid and large area nanofabrication with a simple optical reading not only simplifies the detection process but also makes the biosensors more environmentally friendly and cost-effective. Therefore, the improvements provided in this work will empower researchers and industries for accurate and real-time analysis of biological systems.


Asunto(s)
Técnicas Biosensibles , Nanoestructuras , Técnicas Biosensibles/métodos , Nanoestructuras/química , Resonancia por Plasmón de Superficie , Propiedades de Superficie , Refractometría
5.
Biol Pharm Bull ; 47(6): 1163-1171, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38880624

RESUMEN

The vital role of bile canaliculus (BC) in liver function is closely related to its morphology. Electron microscopy has contributed to understanding BC morphology; however, its invasiveness limits its use in living specimens. Here, we report non-invasive characterization of BC formation using refractive index (RI) tomography. First, we investigated and characterized the RI distribution of BCs in two-dimensional (2D) cultured HepG2 cells. BCs were identified based on their distinct morphology and functionality, as confirmed using a fluorescence-labeled bile acid analog. The RI distribution of BCs exhibited three common features: (1) luminal spaces with a low RI between adjacent hepatocytes; (2) luminal spaces surrounded by a membranous structure with a high RI; and (3) multiple microvillus structures with a high RI within the lumen. Second, we demonstrated the characterization of BC structures in a three-dimensional (3D) culture model, which is more relevant to the in vivo environment but more difficult to evaluate than 2D cultures. Various BC structures were identified inside HepG2 spheroids with the three features of RI distribution. Third, we conducted comparative analyses and found that the BC lumina of spheroids had higher circularity and lower RI standard deviation than 2D cultures. We also addressed comparison of BC and intracellular lumen-like structures within a HepG2 spheroid, and found that the BC lumina had higher RI and longer perimeter than intracellular lumen-like structures. Our demonstration of the non-destructive, label-free visualization and quantitative characterization of living BC structures will be a basis for various hepatological and pharmaceutical applications.


Asunto(s)
Canalículos Biliares , Humanos , Células Hep G2 , Refractometría/métodos , Esferoides Celulares/ultraestructura , Tomografía/métodos , Hepatocitos/ultraestructura , Técnicas de Cultivo de Célula
6.
Sensors (Basel) ; 24(11)2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38894226

RESUMEN

This study presents a novel label-free approach for characterizing cell death states, eliminating the need for complex molecular labeling that may yield artificial or ambiguous results due to technical limitations in microscope resolution. The proposed holographic tomography technique offers a label-free avenue for capturing precise three-dimensional (3D) refractive index morphologies of cells and directly analyzing cellular parameters like area, height, volume, and nucleus/cytoplasm ratio within the 3D cellular model. We showcase holographic tomography results illustrating various cell death types and elucidate distinctive refractive index correlations with specific cell morphologies complemented by biochemical assays to verify cell death states. These findings hold promise for advancing in situ single cell state identification and diagnosis applications.


Asunto(s)
Muerte Celular , Holografía , Imagenología Tridimensional , Tomografía , Holografía/métodos , Tomografía/métodos , Imagenología Tridimensional/métodos , Humanos , Refractometría/métodos
7.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38894440

RESUMEN

Quasi-bound state in the continuum (QBIC) can effectively enhance the interaction of terahertz (THz) wave with matter due to the tunable high-Q property, which has a strong potential application in the detection of low-concentration biological samples in the THz band. In this paper, a novel THz metamaterial sensor with a double-chain-separated resonant cavity structure based on QBIC is designed and fabricated. The process of excitation of the QBIC mode is verified and the structural parameters are optimized after considering the ohmic loss by simulations. The simulated refractive index sensitivity of the sensor is up to 544 GHz/RIU, much higher than those of recently reported THz metamaterial sensors. The sensitivity of the proposed metamaterial sensor is confirmed in an experiment by detecting low-concentration lithium citrate (LC) and bovine serum albumin (BSA) solutions. The limits of detection (LoDs) are obtained to be 0.0025 mg/mL (12 µM) for LC and 0.03125 mg/mL (0.47 µM) for BSA, respectively, both of which excel over most of the reported results in previous studies. These results indicate that the proposed THz metamaterial sensor has excellent sensing performances and can well be applied to the detection of low-concentration biological samples.


Asunto(s)
Técnicas Biosensibles , Albúmina Sérica Bovina , Albúmina Sérica Bovina/química , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Límite de Detección , Animales , Radiación Terahertz , Bovinos , Espectroscopía de Terahertz/métodos , Refractometría , Compuestos de Litio/química , Ácido Cítrico/química
8.
Sci Total Environ ; 935: 173428, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-38777065

RESUMEN

The water-soluble polymer polyvinylpyrrolidone (PVP) is an established ingredient in pharmaceutical and personal care product (PPCP) formulations. Due to its high usage and lack of biodegradability, it has been detected up to 7.0 mg L-1 in wastewater and 0.1 mg L-1 in the receiving freshwaters, with several studies showing detrimental sublethal effects in a range of aquatic species. A lack of simple analytical methods to detect and quantify PVP currently impacts further investigation into the cause of these sublethal effects. In this paper we propose a refractive index gel-permeation chromatography (GPC) method to quantify PVP, which includes the processing of raw chromatograms using line deconvolution to calculate peak area. The method was then applied to Daphnia magna exposed to PVP for 48 h. A limit of detection (LOD) and limit of quantification (LOQ) of 0.05 and 0.2 mg mL-1 respectively was determined, with a recovery of 78 % from spiked Daphnia magna. PVP was detected in the samples above the LOD but below the LOQ. This suggests PVP is ingested by Daphnia magna, which warrants further investigation into whether bioaccumulation of PVP could be causing the sublethal effects seen in other studies.


Asunto(s)
Daphnia , Povidona , Contaminantes Químicos del Agua , Animales , Daphnia/fisiología , Daphnia/efectos de los fármacos , Povidona/química , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/toxicidad , Refractometría , Monitoreo del Ambiente/métodos , Organismos Acuáticos/efectos de los fármacos , Límite de Detección , Polímeros , Daphnia magna
9.
Dent Mater ; 40(7): 1064-1071, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38777732

RESUMEN

OBJECTIVES: To examine the polymerization shrinkage of different resin-based composite (RBC) restorations using optical coherence tomography (OCT) image-based digital image correlation (DIC) analysis. METHODS: The refractive index (RI) of three RBCs, Filtek Z350XT (Z350), Z350Flowable (Z350F), and BulkFill Posterior (Bulkfill), was measured before and after polymerization to calibrate their axial dimensions under OCT. Class I cavities were prepared in bovine incisors and individually filled with these RBCs under nonbonded and bonded conditions. A series of OCT images of these restorations were captured during 20-s light polymerization and then input into DIC software to analyze their shrinkage behaviors. The interfacial adaptation was also examined using these OCT images. RESULTS: The RI of the three composites ranged from 1.52 to 1.53, and photopolymerization caused neglectable increases in the RI values. For nonbonded restorations, Z350F showed maximal vertical displacements on the top surfaces (-16.75 µm), followed by Bulkfill (-8.81 µm) and Z350 (-5.97 µm). In their bonded conditions, all showed increased displacements. High variations were observed in displacement measurements on the bottom surfaces. In the temporal analysis, the shrinkage of nonbonded Z350F and Bulkfill decelerated after 6-10 s. However, Z350 showed a rebounding upward displacement after 8.2 s. Significant interfacial gaps were found in nonbonded Z350 and Z350F restorations. SIGNIFICANCE: The novel OCT image-based DIC analysis provided a comprehensive examination of the shrinkage behaviors and debonding of the composite restorations throughout the polymerization process. The flowable composite showed the highest shrinkage displacements. Changes in the shrinkage direction may occur in nonbonded conventional composite restorations.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Polimerizacion , Tomografía de Coherencia Óptica , Resinas Compuestas/química , Tomografía de Coherencia Óptica/métodos , Bovinos , Animales , Ensayo de Materiales , Propiedades de Superficie , Refractometría , Adaptación Marginal Dental , Preparación de la Cavidad Dental , Procesamiento de Imagen Asistido por Computador
10.
Dent Mater ; 40(6): 958-965, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729780

RESUMEN

OBJECTIVE: To investigate the feasibility of optical coherence tomography (OCT)-based digital image correlation (DIC) analysis and to identify the experimental parameters for measurements of polymerization shrinkage. METHODS: Class I cavities were prepared on bovine incisors and filled with Filtek Z350XT Flowable (Z350F). One OCT image of the polymerized restoration was processed to generate virtually displaced images. In addition, the tooth specimen was physically moved under OCT scanning. A DIC software analyzed these virtual and physical transformation sets and assessed the effects of subset sizes on accuracy. The refractive index of unpolymerized and polymerized Z350F was measured via OCT images. Finally, different particles (70-80 µm glass beads, 150-212 µm glass beads, and 75-150 µm zirconia powder) were added to Z350F to inspect the analyzing quality. RESULTS: The analyses revealed a high correlation (>99.99%) for virtual movements within 131 pixels (639 µm) and low errors (<5.21%) within a 10-µm physical movement. A subset size of 51 × 51 pixels demonstrated the convergence of correlation coefficients and calculation time. The refractive index of Z350F did not change significantly after polymerization. Adding glass beads or zirconia particles caused light reflection or shielding in OCT images, whereas blank Z350F produced the best DIC analysis results. SIGNIFICANCE: The OCT-based DIC analysis with the experimental conditions is feasible in measuring polymerization shrinkage of RBC restorations. The subset size in the DIC analysis should be identified to optimize the analysis conditions and results. Uses of hyper- or hypo-reflective particles is not recommended in this method.


Asunto(s)
Resinas Compuestas , Polimerizacion , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Animales , Bovinos , Resinas Compuestas/química , Circonio/química , Estudios de Factibilidad , Incisivo/diagnóstico por imagen , Ensayo de Materiales , Procesamiento de Imagen Asistido por Computador/métodos , Técnicas In Vitro , Preparación de la Cavidad Dental/métodos , Propiedades de Superficie , Refractometría , Restauración Dental Permanente
11.
Luminescence ; 39(5): e4759, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38693721

RESUMEN

Colloidal semiconductor quantum dots have many potential optical applications, including quantum dot light-emitting diodes, single-photon sources, or biological luminescent markers. The optical properties of colloidal quantum dots can be affected by their dielectric environment. This study investigated the photoluminescence (PL) decay of thick-shell gradient-alloyed colloidal semiconductor quantum dots as a function of solvent refractive index. These measurements were conducted in a wide range of delay times to account for both the initial spontaneous decay of excitons and the delayed emission of excitons that has the form of a power law. It is shown that whereas the initial spontaneous PL decay is very sensitive to the refractive index of the solvent, the power-law delayed emission of excitons is not. Our results seem to exclude the possibility of carrier self-trapping in the considered solvents and suggest the existence of trap states inside the quantum dots. Finally, our data show that the average exciton lifetime significantly decreases as a function of the solvent refractive index. The change in exciton lifetime is qualitatively modeled and discussed.


Asunto(s)
Coloides , Luminiscencia , Puntos Cuánticos , Solventes , Puntos Cuánticos/química , Solventes/química , Coloides/química , Refractometría , Mediciones Luminiscentes , Semiconductores , Factores de Tiempo
12.
J Biomed Opt ; 29(6): 066004, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38751827

RESUMEN

Significance: Scanning laser optical tomography (SLOT) is a volumetric multi-modal imaging technique that is comparable to optical projection tomography and computer tomography. Image quality is crucially dependent on matching the refractive indexes (RIs) of the sample and surrounding medium, but RI matching often requires some effort and is never perfect. Aim: Reducing the burden of RI matching between the immersion medium and sample in biomedical imaging is a challenging and interesting task. We aim at implementing a post processing strategy for correcting SLOT measurements that have errors caused by RI mismatch. Approach: To better understand the problems with poorly matched Ris, simulated SLOT measurements with imperfect RI matching of the sample and medium are performed and presented here. A method to correct distorted measurements was developed and is presented and evaluated. This method is then applied to a sample containing fluorescent polystyrene beads and a sample made of olydimethylsiloxane with embedded fluorescent nanoparticles. Results: From the simulations, it is evident that measurements with an RI mismatch larger than 0.02 and no correction yield considerably worse results compared to perfectly matched measurements. RI mismatches larger than 0.05 make it almost impossible to resolve finer details and structures. By contrast, the simulations imply that a measurement with an RI mismatch of up to 0.1 can still yield reasonable results if the presented correction method is applied. The experiments validate the simulated results for an RI mismatch of about 0.09. Conclusions: The method significantly improves the SLOT image quality for samples with imperfectly matched Ris. Although the absolutely best imaging quality will be achieved with perfect RI matching, these results pave the way for imaging in SLOT with RI mismatches while maintaining high image quality.


Asunto(s)
Refractometría , Tomografía Óptica , Tomografía Óptica/métodos , Refractometría/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Simulación por Computador , Fantasmas de Imagen
13.
PLoS One ; 19(5): e0301007, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38758827

RESUMEN

Building on the Fano resonance observation, a new refractive index transducer structure at the nanoscale is proposed in this article, which is a refractive index transducer consisting of a metal-insulator-metal (MIM) waveguide structure coupled with a ring cavity internally connected to an h-shaped structure (RCIhS). Using an analytical method based on COMSOL software and finite element method (FEM), the effect of different geometric parameters of the structure on the trans-mission characteristics of the system is simulated and analyzed, which in turn illustrates the effect of the structural parameters on the output Fano curves. As simulation results show, the internally connected h-shaped structure is an influential component in the Fano resonance. By optimizing the geometrical parameters of the structure, the system finally accomplishes a sensitivity (S) of 2400 nm/RIU and a figure of merit (FOM) of 68.57. The sensor has also been demonstrated in the realm of temperature detection, having tremendous potential for utilization in future nano-sensing and optically integrated systems.


Asunto(s)
Refractometría , Transductores , Análisis de Elementos Finitos , Diseño de Equipo , Nanotecnología , Temperatura
14.
Biophys Rep (N Y) ; 4(2): 100156, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38718671

RESUMEN

The quantification of physical properties of biological matter gives rise to novel ways of understanding functional mechanisms. One of the basic biophysical properties is the mass density (MD). It affects the dynamics in sub-cellular compartments and plays a major role in defining the opto-acoustical properties of cells and tissues. As such, the MD can be connected to the refractive index (RI) via the well known Lorentz-Lorenz relation, which takes into account the polarizability of matter. However, computing the MD based on RI measurements poses a challenge, as it requires detailed knowledge of the biochemical composition of the sample. Here we propose a methodology on how to account for assumptions about the biochemical composition of the sample and respective RI measurements. To this aim, we employ the Biot mixing rule of RIs alongside the assumption of volume additivity to find an approximate relation of MD and RI. We use Monte-Carlo simulations and Gaussian propagation of uncertainty to obtain approximate analytical solutions for the respective uncertainties of MD and RI. We validate this approach by applying it to a set of well-characterized complex mixtures given by bovine milk and intralipid emulsion and employ it to estimate the MD of living zebrafish (Danio rerio) larvae trunk tissue. Our results illustrate the importance of implementing this methodology not only for MD estimations but for many other related biophysical problems, such as mechanical measurements using Brillouin microscopy and transient optical coherence elastography.


Asunto(s)
Refractometría , Pez Cebra , Animales , Refractometría/métodos , Bovinos , Leche/química , Método de Montecarlo , Larva/química
15.
ACS Sens ; 9(4): 1857-1865, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38597428

RESUMEN

Resonant photonic refractive index sensors have made major advances based on their high sensitivity and contact-less readout capability, which is advantageous in many areas of science and technology. A major issue for the technological implementation of such sensors is their response to external influences, such as vibrations and temperature variations; the more sensitive a sensor, the more susceptible it also becomes to external influences. Here, we introduce a novel bowtie-shaped sensor that is highly responsive to refractive index variations while compensating for temperature changes and mechanical (linear and angular) vibrations. We exemplify its capability by demonstrating the detection of salinity to a precision of 0.1%, corresponding to 2.3 × 10-4 refractive index units in the presence of temperature fluctuations and mechanical vibrations. As a second exemplar, we detected bacteria growth in a pilot industrial environment. Our results demonstrate that it is possible to translate high sensitivity resonant photonic refractive index sensors into real-world environments.


Asunto(s)
Fotones , Refractometría , Temperatura , Vibración , Salinidad
16.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38626737

RESUMEN

A novel fiber optic biosensor was purposed for a new approach to monitor amyloid beta protein fragment 1-42 (Aß42) for Alzheimer's Disease (AD) early detection. The sensor was fabricated by etching a part of fiber from single mode fiber loop in pure hydrofluoric acid solution and utilized as a Local Optical Refractometer (LOR) to monitor the change Aß42 concentration in Artificial Cerebrospinal Fluid (ACSF). The Fiber Loop Ringdown Spectroscopy (FLRDS) technique is an ultra-sensitive measurement technique with low-cost, high sensitivity, real-time measurement, continuous measurement and portability features that was utilized with a fiber optic sensor for the first time for the detection of a biological signature in an ACSF environment. Here, the measurement is based on the total optical loss detection when specially fabricated sensor heads were immersed into ACSF solutions with and without different concentrations of Aß42 biomarkers since the bulk refractive index change was performed. Baseline stability and the reference ring down times of the sensor head were measured in the air as 0.87% and 441.6µs ± 3.9µs, respectively. Afterward, the total optical loss of the system was measured when the sensor head was immersed in deionized water, ACSF solution, and ACSF solutions with Aß42 in different concentrations. The lowest Aß42 concentration of 2 ppm was detected by LOR. Results showed that LOR fabricated by single-mode fibers for FLRDS system design are promising candidates to be utilized as fiber optic biosensors after sensor head modification and have a high potential for early detection applications of not only AD but possibly also several fatal diseases such as diabetes and cancer.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Técnicas Biosensibles , Diagnóstico Precoz , Tecnología de Fibra Óptica , Fragmentos de Péptidos , Análisis Espectral , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/análisis , Humanos , Tecnología de Fibra Óptica/métodos , Fragmentos de Péptidos/análisis , Técnicas Biosensibles/métodos , Análisis Espectral/métodos , Fibras Ópticas , Biomarcadores/análisis , Refractometría , Diseño de Equipo
17.
Photodiagnosis Photodyn Ther ; 46: 104094, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38642728

RESUMEN

OBJECTIVE: Oral cancer is a leading cause of mortality globally, particularly affecting developing regions where oral hygiene is often overlooked. The optical properties of tissues are vital for diagnostics, with polarization imaging emerging as a label-free, contrast-enhancing technique widely employed in medical and scientific research over past few decades. MATERIALS AND METHODS: We present a novel polarization sensitive quantitative phase imaging of biological tissues by incorporating the conventional polarization microscope and transport of intensity equation-based phase retrieval algorithm. This integration provides access to the birefringence mapping of biological tissues. The inherent optical anisotropy in biological tissues induces the polarization dependent refractive index variations which can provide the detailed insights into the birefringence characteristics of their extracellular constituents. Experimental investigations were conducted on both normal and cancerous oral tissue samples by recording a set of three polarization intensity images for each case with a step size of 2 µm. RESULTS: A noteworthy increment in birefringence quantification was observed in cancerous as compared to the normal tissues, attributed to the proliferation of abnormal cells during cancer progression. The mean birefringence values were calculated for both normal and cancerous tissues, revealing a significant increase in birefringence of cancerous tissues (2.1 ± 0.2) × 10-2 compared to normal tissues (0.8 ± 0.2) × 10-2. Data were collected from 8 patients in each group under identical experimental conditions. CONCLUSION: This polarization sensitive non-interferometric optical approach demonstrated effective discrimination between cancerous and normal tissues, with various parameters indicating elevated values in cancerous tissues.


Asunto(s)
Microscopía de Polarización , Neoplasias de la Boca , Birrefringencia , Humanos , Microscopía de Polarización/métodos , Neoplasias de la Boca/diagnóstico por imagen , Algoritmos , Refractometría/métodos , Imágenes de Fase Cuantitativa
18.
ACS Sens ; 9(3): 1208-1217, 2024 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-38466967

RESUMEN

Optical scattering has been widely used for aerosol sizing due to its noninvasive and real-time measurement. However, it is crucial to retrieve the particle size distribution (PSD) of aerosols without prior knowledge of the refractive index. Now, it has been a great challenge to measure the refractive index in situ. In this study, a novel PSD sensing method utilizing the light scattering angular spectrum (LSAS) and machine learning techniques is proposed to address this challenge. The complex nonlinear relationship between LSAS and PSD can be constructed while accounting for the refractive index of aerosols. A miniaturized prototype sensor is designed and tested on different sizes of aerosol samples. The experiment results showed that the maximum Kullback-Leibler divergence (DKL) of PSD is 0.07, which indicates that the sensing method can provide the ability for highly accurate aerosol PSD measurement without requiring prior knowledge of the refractive index. The compacted prototype sensor shows great potential for aerosol analysis in conventional field measurements outside the laboratory.


Asunto(s)
Luz , Refractometría , Tamaño de la Partícula , Aerosoles , Refractometría/métodos
19.
Biosens Bioelectron ; 255: 116206, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38531226

RESUMEN

In the detection of biomolecules, surface plasmon resonance (SPR) sensors require high sensitivity. In this study, we propose a sensitivity-enhanced functionalized plasmonic interface based on Ag-TiO2-Co(OH)2 nanosheets structure. Compared to unmodified SPR sensors, the sensitivity of the sensor decorated with TiO2 and Co(OH)2 nanosheets is increased by 130.84%, reaching 5764.27 nm/RIU. This enhancement is attributed to the high refractive index of the coating, as well as the high specific surface area and abundant active sites provided by the synthesized Co(OH)2 nanosheets with a multi-grooved structure. Additionally, employing a double-antibody sandwich method, the antibody-functionalized plasmonic interface enables specific detection of human serum albumin (HSA). The linear response of this sensor was in the wide range of 0.4-150 µM, and the LOD reached 154.89 nM(KD is approximately 1.73 × 10-6 M). This novel SPR sensor offers a new strategy for biochemical sensing and provides a highly sensitive platform for immunoassays.


Asunto(s)
Técnicas Biosensibles , Humanos , Resonancia por Plasmón de Superficie , Refractometría , Anticuerpos , Alimentos
20.
Methods Mol Biol ; 2789: 21-29, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38506987

RESUMEN

Nanomaterials are inherently polydisperse. Traditional techniques, such as the widely used batch-mode dynamic light-scattering (DLS) analysis, are not ideal nor thoroughly descriptive enough to define the full complexity of these materials. Asymmetric-flow field-flow fractionation (AF4) with various in-line detectors, such as ultraviolet-visible (UV-vis), multi-angle light scattering (MALS), refractive index (RI), and DLS, is an alternative technique that can provide flow-mode analysis of not only size distribution but also shape, drug release/stability, and protein binding.


Asunto(s)
Fraccionamiento de Campo-Flujo , Nanopartículas , Dispersión Dinámica de Luz , Refractometría , Fraccionamiento de Campo-Flujo/métodos , Luz , Tamaño de la Partícula
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA