Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.775
Filtrar
1.
Clin Oral Investig ; 28(6): 308, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38733458

RESUMEN

AIMS: This study aimed to evaluate the visual improvement of resin infiltration of white spot lesions (WSL) during orthodontic treatment with the multibracket appliance (MBA) compared to fluoride varnish. METHODS: Patients aged 12-17 years with at least one WSL with an International Caries Detection and Assessment System (ICDAS) score of 1-2 during an active MBA treatment were included and randomized to receive either resin infiltration (Icon) or fluoride application (Flairesse). Standardized digital images were obtained before, one-day, one-week, one-month, three-months and six-months after treatment using a DSLR camera and a matching polarization filter. A grey reference card was used for color standardization. A Matlab routine was used to measure the color difference between adjacent healthy enamel and treated WSL. The independent-samples t-test was used for intergroup and paired-samples t-test for intragroup comparison. RESULTS: Images of 116 teeth from 36 patients were analyzed. The ΔE for the "Icon" treated WSL was smaller (T1ICON = 5.0 ± 1.4) than in the fluoride group (T1Fluoride = 8.4 ± 3.2). Caries infiltration significantly improved the aesthetic appearance of WSL (p < 0.001), which remained satisfactory at six months (T5ICON = 5.2 ± 1.6). CONCLUSION: WSL infiltration management during orthodontic treatment was superior to topical fluoridation in not only arresting the enamel lesions but also significantly improving the aesthetic appearance of demineralized regions around the brackets. CLINICAL RELEVANCE: WSL treatment in orthodontic patients is usually initiated after debonding. Research has shown that the earlier WSL is treated, the better the aesthetic outcome. There is limited data on the efficacy of resin infiltration of WSL during orthodontic treatment.


Asunto(s)
Cariostáticos , Caries Dental , Fluoruros Tópicos , Soportes Ortodóncicos , Adolescente , Niño , Femenino , Humanos , Masculino , Cariostáticos/uso terapéutico , Caries Dental/terapia , Caries Dental/prevención & control , Fluoruros Tópicos/uso terapéutico , Resinas Sintéticas/uso terapéutico , Resultado del Tratamiento
2.
Int J Prosthodont ; 37(7): 165-173, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38787581

RESUMEN

PURPOSE: To investigate the impact of printing layer thickness on the optical properties and surface roughness of various 3D-printed resins manufactured by digital light processing (DLP) and indicated for provisional and definitive restorations. MATERIALS AND METHODS: A total of 240 specimens from four different 3D-printing resins-VarseoSmile Crown Plus (Bego; VS), Crowntec (Saremco Dental; CR), GC Temp PRINT (GC Dental; TG), and NextDent C&B MFH (NextDent; ND)-were divided into four groups (n = 60 per group). Each group was further divided into three subgroups (n = 20) according to printing layer thickness (25, 50, and 100 µm). All specimens were subjected to thermocycling with coffee before measurements were taken with a spectroradiometer to calculate color differences. The Kubelka-Munk (K-M) absorption (K) and scattering coefficients (S), translucency parameters (TP), and surface roughness (Ra) values were calculated for each printing layer thickness and compared with those of the 2M2 shade tab (target). The data were analyzed using Mann-Whitney U test, the variance accounted for (VAF) coefficient by Cauchy-Schwarz, and post hoc comparisons using Tukey test (α ≤ .05). RESULTS: S (79% ≤ VAF ≤ 100%) and K (40.45% ≤ VAF ≤ 100%) spectral distribution depended on the wavelength. A 25-µm layer thickness resulted in no significant differences from the 2M2 shade for S (P > .230) and K (P > .200). VS showed significantly different S (P = .004) and K (P = .003) values from those of the shade tab with 50-µm layering thickness, whereas other materials did not show significant differences from the 2M2 shade for S (P > .280) and K (P > .301). The 100-µm layer thickness specimens had significantly different S and K values compared to the 2M2 shade tab (P < .004). TP values of resins with 100-µm layer thickness were significantly lower than resins in 25- and 50-µm layer thicknesses (P < .001). The Ra values of resins increased significantly with 100-µm layer thickness (P ≤ .001). CONCLUSIONS: All tested materials, except for VS, showed color properties similar to the target shade when 25- and 50-µm printing layer thicknesses were used. The translucency of resins tended toward an inverse relationship with printing layer thickness. The surface roughness of resins increased significantly with 100-µm layer thickness. However, all resins with a printing thickness of 25 µm showed better color properties and surface roughness.


Asunto(s)
Impresión Tridimensional , Propiedades de Superficie , Ensayo de Materiales , Técnicas In Vitro , Resinas Compuestas/química , Resinas Sintéticas/química
3.
J Chromatogr A ; 1727: 464992, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-38761701

RESUMEN

Post-detonation nuclear forensics capabilities depend on the ability to rapidly isolate radionuclides to improve measurement quality. In this work an extraction chromatography resin was developed utilizing thenoyltrifluoroacetone and 1-octanol supported on Eichrom prefilter resin. The resin was tested in nitric and hydrochloric acid matrices. In nitric acid the resin was able to extract zirconium, while in hydrochloric acid matrices it was possible to extract iron and gallium. In all acid conditions tested, gold was retained but can be eluted from the column with 10 % thiourea.


Asunto(s)
Oro , Oro/química , Elementos de Series Actinoides/aislamiento & purificación , Elementos de Series Actinoides/química , Ácido Clorhídrico/química , Resinas Sintéticas/química , Circonio/química , Ácido Nítrico/química
4.
Cutis ; 113(4): 191-192, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38820097

RESUMEN

Lichen planus (LP) is one of the few conditions that may cause permanent and debilitating nail loss. Recurrence is common despite treatment with first-line therapies including intralesional and systemic corticosteroids. We describe application of a resin nail for recalcitrant LP of the fingernail for improved cosmesis and functionality.


Asunto(s)
Liquen Plano , Enfermedades de la Uña , Humanos , Liquen Plano/tratamiento farmacológico , Enfermedades de la Uña/tratamiento farmacológico , Enfermedades de la Uña/terapia , Femenino , Resinas Sintéticas , Uñas/patología , Persona de Mediana Edad
5.
Sci Rep ; 14(1): 12444, 2024 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816512

RESUMEN

This preregistered ex vivo investigation examined the dentinal hybrid layer formation of a resinous infiltrant (Icon), with reference to both thickness (HLT) and homogeneity when combined with modified tunnel preparation (occlusal cavity only) and internal/external caries infiltration. The adhesives Syntac and Scotchbond MP were used as controls (Groups 1 and 3) or in combination with Icon (Groups 2 and 4). A split-tooth design using healthy third molars from 20 donors resulted in 20 prepared dentine cavities per experimental group. The cavity surfaces (n = 80) were etched (37% H3PO4), rinsed, and air-dried. Rewetting with ethanol was followed by application of the respective primers. After labeling with fluorescent dyes, either Syntac Adhesive/Heliobond or Scotchbond MP Adhesive was used alone or supplemented with Icon. HLT, as evaluated by scanning electron microscopy, did not significantly differ (P > 0.05), and confocal laser scanning microscopy revealed homogeneously mixed/polymerized resin-dentine interdiffusion zones in all groups. Icon can be successfully integrated into an ethanol-wet dentine bonding strategy, and will result in compact and homogeneous hybrid layers of comparable thickness considered equivalent to the non-Icon controls, thus allowing for preservation of the tooth's marginal ridge and interdental space in the case of internal/external infiltration of proximal caries.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Dentina , Etanol , Humanos , Etanol/química , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Tercer Molar , Cementos de Resina/química , Restauración Dental Permanente/métodos , Microscopía Confocal , Resinas Sintéticas/química , Caries Dental/terapia , Microscopía Electrónica de Rastreo , Resinas Compuestas/química
6.
J Sep Sci ; 47(11): e2400145, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38822225

RESUMEN

In this study, a combination approach involving macroporous resin (MR) column chromatography and gradient countercurrent chromatography (CCC) was employed to enrich and purify bufadienolides from the roots and rhizomes of Helleborus thibetanus Franch. Initially, a D101 MR-packed column chromatography was utilized for fractionation and enrichment of the bufadienolides, which were effectively eluted from the column using a 60% ethanol solution. CCC was subsequently introduced to separate the enriched product using the ethyl acetate/n-butanol/water (EBuWat, 4:1:5, v/v) and EBuWat (5:0:5, v/v) solvent systems in a gradient elution mode. As results, five bufadienolides, including 6.1 mg of hellebrigenin-3-O-ß-D-glucoside (1), 2.2 mg of tigencaoside A (2), 8.3 mg of deglucohellebrin (3), 3.5 mg of 14 ß-hydroxy-3ß-[ß-D-glucopyranosyl-(1→6)-(ß-D-glucopyranosyl)oxy]-5α-bufa-20,22-dienolide (4), and 3.0 mg of 14ß-hydroxy-3ß-[(ß-D-glucopyranosyl)oxy]-5α-bufa-20,22-dienolide (5), were effectively separated from 300 mg of the enriched product. The respective high-performance liquid chromatography purities were as follows: 95.2%, 75.8%, 85.7%, 82.3%, and 92.8%. This study provides valuable insights for the efficient enrichment and separation of bufadienolides from Helleborus thibetanus Franch.


Asunto(s)
Bufanólidos , Distribución en Contracorriente , Helleborus , Distribución en Contracorriente/métodos , Bufanólidos/química , Bufanólidos/aislamiento & purificación , Helleborus/química , Porosidad , Resinas Sintéticas/química , Cromatografía Líquida de Alta Presión , Raíces de Plantas/química
7.
J Mech Behav Biomed Mater ; 155: 106568, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38714003

RESUMEN

PURPOSE: The strength of temporary restorations plays a vital role in full-mouth reconstruction, and it can be impacted by the aging process. The aim of this in vitro study was to evaluate the biaxial flexural strength and fractographic features of different resin-based materials submitted to thermal aging. MATERIAL AND METHODS: One hundred and ninety-two resin disc-shaped specimens (6.5 mm in diameter and 0.5 mm in thickness) were fabricated and divided into six experimental groups according to the resin-based materials (Filtek Bulk-Fill flowable resin; J-Temp temporary resin; and Fuji Lining glass ionomer cement) and aging process (before and after thermal cycling). Biaxial flexural strength test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min before and after thermal cycling (5 °C and 55 °C, 5760 cycles, 30 s). The mechanical properties were assessed using Weibull parameters (characteristic strength and Weibull modulus) (n = 30). Fractured specimens were examined under a polarized light stereomicroscope to identify crack origin and propagation direction. The surface microstructure of the resin-based materials was assessed by scanning electron microscopy (n = 2). The Weibull modulus (m), characteristic strength, and reliability properties were calculated, and a contour plot was used to detect differences among groups (95% confidence interval). RESULTS: The Weibull modulus (m), characteristic strength, and reliability of the resin-based compounds were influenced by material type and thermal aging (p < 0.05). Weibull modulus (m) revealed no differences when comparing the materials and aging process (p > 0.05), except for the preceding aging period where Filtek Bulk-Fill exhibited higher values compared to J-Temp (p < 0.05). Filtek Bulk-Fill demonstrated superior characteristic strength and reliability compared to J-Temp and Fuji Lining before and after thermal cycling (p < 0.05). Fractography of the resin-based materials showed fractures originating from surface defects exposed to tensile side and their propagation toward the compressive side. Generally, no differences in surface microstructure were observed on micrographs before and after thermal aging for Filtek Bulk-Fill and Fuji Lining. However, the aging process developed flaws in J-Temp. CONCLUSION: Resin-based material composition resulted in different flexural strength performance, impacting the Weibull modulus (m), characteristic strength, and reliability of the resin-based restorations.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Ensayo de Materiales , Resinas Compuestas/química , Resinas Sintéticas/química , Temperatura , Factores de Tiempo , Agua/química , Estrés Mecánico
8.
Curr Protoc ; 4(4): e1029, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38666611

RESUMEN

The loading (i.e., substitution) of solid supports for oligonucleotide synthesis is an important parameter in large-scale manufacturing of oligonucleotides. Several key process parameters are dependent on the substitution of the solid support, including the number of phosphoramidite nucleoside equivalents used in the coupling step. For dimethoxytrityl (DMTr)-loaded solid supports, the substitution of the resin is determined by quantitatively cleaving the DMTr protecting group from the resin under acidic conditions and then analyzing the DMTr cation extinction by UV/vis spectroscopy. The spectrometric measurement can be performed at 409 nm or the global extinction maximum of 510 nm. The substitution is then calculated based on the Lambert-Beer law analogously to the substitution determination of Fmoc-substituted resins. Below, the determination of the molar extinction coefficient at 510 nm in a solution of 10% dichloroacetic acid in toluene and subsequent determination of the DMTr loading of DMTr-substituted resins is reported. © 2024 The Authors. Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Determination of the molar extinction coefficient at 510 nm in DCA Deblock solution Basic Protocol 2: Substitution determination of DMTr-substituted resins by cleavage of the DMTr cation.


Asunto(s)
Oligonucleótidos , Oligonucleótidos/química , Oligonucleótidos/síntesis química , Técnicas de Síntesis en Fase Sólida/métodos , Resinas Sintéticas/química
9.
Sci Rep ; 14(1): 9909, 2024 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-38688952

RESUMEN

Three-dimensional (3D) printing, otherwise known as additive manufacturing in a non-technical context, is becoming increasingly popular in the field of dentistry. As an essential step in the 3D printing process, postwashing with organic solvents can damage the printed resin polymer and possibly pose a risk to human health. The development of water-washable dental resins means that water can be used as a washing agent. However, the effects of washing agents and washing times on the mechanical and biocompatibility properties of water-washable resins remain unclear. This study investigated the impact of different washing agents (water, detergent, and alcohol) and washing time points (5, 10, 20, and 30 min) on the flexural strength, Vickers hardness, surface characterization, degree of conversion, biocompatibility, and monomer elution of 3D printed samples. Using water for long-term washing better preserved the mechanical properties, caused a smooth surface, and improved the degree of conversion, with 20 min of washing with water achieving the same biological performance as organic solvents. Water is an applicable agent option for washing the 3D printing water-washable temporary crown and bridge resin in the postwashing process. This advancement facilitates the development of other water-washable intraoral resins and the optimization of clinical standard washing guidelines.


Asunto(s)
Materiales Biocompatibles , Ensayo de Materiales , Impresión Tridimensional , Agua , Agua/química , Materiales Biocompatibles/química , Ensayo de Materiales/métodos , Humanos , Resinas Sintéticas/química , Dureza , Coronas , Propiedades de Superficie
10.
Food Chem ; 450: 139341, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-38631206

RESUMEN

The escalating use of pesticides on fruits and vegetables has raised concerns about potential health risks. Therefore, we developed a superhydrophilic resin/graphene oxide (SR/GO) with rich adsorption interactions using an eco-friendly synthetic approach. SR/GO demonstrated excellent hydrophilicity, ensuring optimal contact with aqueous sample matrices. The multiple adsorption interactions, including π-π conjugation, hydrogen bonding, and electrostatic adsorption, facilitated multi-pesticide residue co-extraction. The synthesized SR/GO was applied to a miniaturized centrifugation-accelerated pipette-tip extraction method, coupled with high-performance liquid chromatography. The optimized method exhibited low consumption (15.0 mg adsorbent), and high efficiency, with low detection limits (1.4-2.9 ng g-1) and high recoveries (75.3-113.0%). Water-compatible SR/GO, along with a miniaturized extraction process, showcases a potent analytical approach for pesticide residue analysis in fruits and vegetables. The significance of this method lies in its ability to ensure agricultural and food safety by using a low-cost and efficient multi-pesticide residue analytical strategy.


Asunto(s)
Contaminación de Alimentos , Frutas , Grafito , Interacciones Hidrofóbicas e Hidrofílicas , Residuos de Plaguicidas , Verduras , Verduras/química , Grafito/química , Residuos de Plaguicidas/química , Residuos de Plaguicidas/análisis , Frutas/química , Contaminación de Alimentos/análisis , Adsorción , Cromatografía Líquida de Alta Presión , Tecnología Química Verde , Resinas Sintéticas/química
11.
Chemosphere ; 356: 141875, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38583532

RESUMEN

While passive sampling of ultra-low aqueous concentrations of hydrophobic organic compounds in environmental aqueous media has emerged as a promising analytical technique, there is a lack of good understanding of the fundamental diffusive processes. In this research, we used a fluorophore, pyrene, as a model compound to track diffusion in polymers through absorption and environmental media exchange processes. We directly tracked the penetration of pyrene into polyethylene (PE) and polyoxymethylene (POM) rods during absorption from water by sectioning the rod after different stages of absorption and observing the fluorescence signal through a microscope. Diffusion profiles of pyrene in polymers were simulated by numerical integration of Fickian diffusion. The results indicated that the uptake process in PE is governed by Fick's law and the absorption and desorption kinetics are similar in this polymer. However, the observed uptake profiles of pyrene in POM were non-Fickian and the release kinetics out of POM was slower compared to uptake into the polymer. We show that slower desorption from POM makes corrections for nonequilibrium using performance reference compounds (PRCs) problematic for deployments in water or sediment where there is significant advection. However, for static sediment deployments, the overall kinetics of exchange is controlled by slow transport through sediment and the hysteretic behavior of POM may not preclude the use of PRCs to interpret equilibrium status.


Asunto(s)
Monitoreo del Ambiente , Polietileno , Pirenos , Resinas Sintéticas , Contaminantes Químicos del Agua , Pirenos/química , Polietileno/química , Difusión , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química , Monitoreo del Ambiente/métodos , Cinética , Polímeros/química
12.
J Indian Prosthodont Soc ; 24(2): 196-200, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38650345

RESUMEN

BACKGROUND: In-office three-dimensional (3D) printers and metal sleeveless surgical guides are becoming a major trend recently. However, metal sleeve-free designs are reported to be more prone to distortion which might lead to variation in the inner diameter of the drill hole and cause deviation and inaccuracy in the placement of the implant. Carbon fiber nanoparticles are reported to improve the properties of 3D printing resin material in industrial application. AIM: The purpose of the study is to evaluate and compare the wear resistance of 3D-printed implant guides with metal sleeve, sleeve-free, and reinforced sleeve-free resin to the guide drill. MATERIALS AND METHODS: A total of 66 samples with 22 samples in each group. Three groups including 3D-printed surgical guide with metal sleeve (Group A), without metal sleeve (Group B), an carbon fiber reinforced without metal sleeve (Group C) were included in the study. All samples were evaluated before sequential drilling and after sequential drilling using Vision Measuring Machine. The data were tabulated and statistically evaluated. RESULTS: The data obtained were statistically analyzed with one-way analysis of variance and posthoc test. The data obtained for wear observed in the samples showed that the wear was highest in Group B with a mean of 0.5036 ± 0.1118 and the least was observed in Group A with a mean of 0.0228 ± 0.0154 and Group C was almost similar to Group A with mean of 0.0710 ± 0.0381. The results showed there was a significant difference between Group B with Group A and C, respectively (P < 0.05). The results showed that there was no significant difference regarding the wear observed between Groups A and C (P > 0.05). CONCLUSION: The wear observed in the guide with a metal sleeve and carbon fiber reinforced without a metal sleeve was almost similar. The carbon fiber-reinforced guide showed better tolerance to guide drill equivalent to metal sleeve. Thus, carbon fiber nanoparticles reinforced in 3D printing resin have shown improved strength and can be used as a good replacement for a metal sleeve for an accurate placement of the implant.


Asunto(s)
Impresión Tridimensional , Ensayo de Materiales/métodos , Técnicas In Vitro , Metales/química , Fibra de Carbono/química , Resinas Sintéticas/química , Humanos , Implantes Dentales
13.
BMC Oral Health ; 24(1): 365, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38515110

RESUMEN

BACKGROUND: Treating white spot lesions (WSLs) with resin infiltration alone may not be sufficient, raising questions about its compatibility with other treatments amid controversial or incomplete data. Therefore, this study aimed to assess the aesthetic feasibility of resin infiltration combined with bleaching, as well as its potential mechanical effect on ceramic bonding to WSLs. METHODS: One hundred and fifty flat enamel surfaces of bovine incisors were prepared. Ninety specimens were deminerailized and randomly assigned to three groups(n = 30): post-bleaching resin infiltration (Bl-R), pre-bleaching resin infiltration (R-Bl), and only resin infiltration (R). Color, surface roughness and microhardness were assessed in immediate, thermocycling and pigmentation tests. The remaining sixty samples were randomly assigned to three groups (n = 20): control (Ctrl), bonding (Bo), pre-bonding resin infiltration (R-Bo). Shear bonding strength, failure mode, micro-leakage depth and interface morphology were evaluated after ceramic bonding. The Tukey test and analysis of variance (ANOVA) were used for statistical analysis. RESULTS: For the effect of resin infiltration and bleaching on WSLs, the R-Bl group showed the worst chromic masking ability, with the highest |ΔL|, |Δa|, |Δb|, and ΔE values after treatment. Compared with those in the Bl-R group, the R-Bl and R groups showed significant time-dependent staining, which is possibly attributed to their surface roughness. For the effect of resin infiltration on the adhesive properties of WSLs, resin infiltration reduced the staining penetration depth of WSLs from 2393.54 ± 1118.86 µm to 188.46 ± 89.96 µm (P < 0.05) while reducing WSLs porosity in SEM observation. CONCLUSIONS: Post-bleaching resin infiltration proved to be advantageous in the aesthetic treatment of WSLs. Resin infiltration did not compromise bonding strength but it did reduce microleakage and enhance marginal sealing. Overall, resin infiltration can effectively enhance the chromatic results of treated WSLs and prevent long-term bonding failure between ceramics and enamel. Based on these findings, the use of post-bleaching resin infiltration is recommended, and resin infiltration before ceramic bonding is deemed viable in clinical practice.


Asunto(s)
Caries Dental , Resinas Sintéticas , Humanos , Animales , Bovinos , Resinas Sintéticas/uso terapéutico , Caries Dental/terapia , Estética Dental , Esmalte Dental , Cerámica
14.
Int J Prosthodont ; 37(7): 151-158, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38498866

RESUMEN

PURPOSE: This study investigated the impact of reducing the oxygen concentration via nitrogen injection during the postcuring process of 3D-printed dental materials. MATERIALS AND METHODS: Resin specimens for dental crown and bridge (15-mm diameter, both 1-mm and 2-mm heights) were 3D-printed and rinsed. Subsequently, the postcuring process was conducted on nine groups categorized according to atmospheric conditions within the curing device (20% [control], 10%, and 5% oxygen) and curing times (10, 15, and 20 minutes). Surface roughness was measured using a gloss meter. Surface polymerization was confirmed through Fourier-transform infrared spectroscopy (FT-IR) analysis, and the flexural strength and elastic modulus of the specimens were measured using a universal testing machine. Water absorption and solubility were determined according to Inernational Organization for Standardization (ISO) standards. All evaluation criteria were statistically analyzed using one-way ANOVA and Tukey's post hoc test based on oxygen concentration. RESULTS: The elastic modulus did not show statistically significant differences in all groups. However, compared to the control group, the flexural strength, degree of conversion, and gloss significantly increased in the groups with decreased oxygen concentrations. Conversely, water solubility and water absorption significantly decreased in a few groups with reduced oxygen concentration. CONCLUSIONS: Reducing oxygen concentration through nitrogen injection during the postcuring process of 3D printing enhances the suitability of the dental prosthetic materials. The significant increase in flexural strength can particularly enhance the utility of these materials in dental prosthetics.


Asunto(s)
Impresión Tridimensional , Agua , Espectroscopía Infrarroja por Transformada de Fourier , Ensayo de Materiales , Docilidad , Agua/química , Nitrógeno , Resinas Sintéticas , Propiedades de Superficie
15.
Eur J Paediatr Dent ; 25(2): 132-136, 2024 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-38436607

RESUMEN

BACKGROUND: It is quite common for white spots to develop on a tooth, due sometimes to a defective formation of the enamel layer, and sometimes to patches of demineralisation as a result of poor oral hygiene during orthodontic treatment with fixed braces. ICON DMG is currently the only noninvasive treatment for white spots. After a preliminary etching, it infiltrates the enamel, filling the spaces between the prisms with a resinous material that has a refraction coefficient very similar to that of healthy tooth enamel. The aim of this study was to test the efficacy of professional whitening procedures on teeth previously treated with ICON. The study hypothesis was that infiltration with ICON resin creates a barrier capable of preventing the bleaching action of the whitening agent. MATERIALS: White spots were artificially created on one half of the vestibular surface of 12 human teeth, while the other half was protected with a composite adhesive. The white spots were infiltrated with ICON and the protective adhesive was subsequently removed. A professional teeth whitening procedure was then completed on both halves of the teeth. A statistical analysis was performed to compare spectrophotometric recordings obtained before and after the ICON infiltration and teeth whitening procedures. CONCLUSION: The whitening procedure modified the colour of the teeth on the half not infiltrated with ICON (p<0.05), but there was no statistically significant change in colour on the half infiltrated with ICON. The presence of the ICON resin seems to act as a partial barrier to the action of the whitening agent.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/uso terapéutico , Esmalte Dental/efectos de los fármacos , Espectrofotometría , Decoloración de Dientes , Resinas Sintéticas/uso terapéutico , Color
16.
J Prosthet Dent ; 131(5): 935.e1-935.e8, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38431509

RESUMEN

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials have become popular for dental restorations; however, which materials should be preferred in terms of surface properties after biofilm formation is unclear. PURPOSE: The purpose of this in vitro study was to investigate the effect of biofilm formation on the discoloration properties of resin-infiltrated ceramic and glass-ceramic CAD-CAM materials and human teeth and to examine the effect of the brushing procedure on color change. MATERIAL AND METHODS: One hundred and six 2-mm-thick specimens were prepared from IPS e.max CAD and Cerasmart, and a total of 53 intact human teeth were used. Five specimens from each group were used to measure the amount of live biomass in the biofilm. The remaining 48 specimens in each group were divided into 4 subgroups: kept in distilled water without the formation of dental biofilm (DW), kept in tea without the formation of dental biofilm (T), kept in distilled water after the formation of dental biofilm (DWB), and kept in tea after the formation of dental biofilm (TB) (n=12). After finishing and polishing the materials, initial color measurements were made using a spectrophotometer, and surface roughness measurements were made using noncontact profilometer. After creating a biofilm layer in DWB and TB, all specimens were kept in their solutions at 37 °C for 24 hours, and the color measurements were repeated. After the biofilm layer had been removed by brushing, a third color measurement was made. The data were statistically analyzed with one-way analysis of variance (ANOVA) and two-way ANOVA (α=.05). RESULTS: The lowest roughness value was observed in Cerasmart. Tooth-IPS e.max CAD gave similar results. The Cerasmart material had the most viable biomass, whereas the IPS e.max CAD material had the least. TB had the highest ΔE1 value for all materials and DW had the lowest (P<.05). The brushing procedure caused the materials to return to their initial colors or reduce the color change in most groups. CONCLUSIONS: The presence of biofilm on CAD-CAM materials immersed in distilled water caused an unacceptable degree of discoloration (ΔE>1.8), and immersion in tea led to greater color change. The adhesion of biofilm to restorative dental materials plays an important role in the coloring of these dental materials.


Asunto(s)
Biopelículas , Cerámica , Color , Diseño Asistido por Computadora , Porcelana Dental , Propiedades de Superficie , Cerámica/química , Humanos , Ensayo de Materiales , Técnicas In Vitro , Materiales Dentales/química , Cepillado Dental , Resinas Sintéticas
17.
Macromol Rapid Commun ; 45(11): e2400036, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38453138

RESUMEN

Preparation of materials that possess highly strong and tough properties simultaneously is a great challenge. Thermosetting resins as a type of widely used polymeric materials without synergistic strength and toughness limit their applications in some special fields. In this report, an effective strategy to prepare thermosetting resins with synergistic strength and toughness, is presented. In this method, the soft and rigid microspheres with dynamic hemiaminal bonds are fabricated first, followed by hot-pressing to crosslink at the interfaces. Specifically, the rigid or soft microspheres are prepared via precipitation polymerization. After hot-pressing, the resulting rigid-soft blending materials exhibit superior strength and toughness, simultaneously. As compared with the precursor rigid or soft materials, the toughness of the rigid-soft blending films (RSBFs) is improved to 240% and 2100%, respectively, while the strength is comparable to the rigid precursor. As compared with the traditional crushing, blending, and hot-pressing of rigid or soft materials to get the nonuniform materials, the strength and toughness of the RSBFs are improved to 168% and 255%, respectively. This approach holds significant promise for the fabrication of polymer thermosets with a unique combination of strength and toughness.


Asunto(s)
Polimerizacion , Resinas Sintéticas/química , Microesferas , Polímeros/química , Temperatura , Ensayo de Materiales , Propiedades de Superficie , Tamaño de la Partícula
19.
J Chromatogr A ; 1715: 464621, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38198876

RESUMEN

White tea contains the highest flavonoids compared to other teas. While there have been numerous studies on the components of different tea varieties, research explicitly focusing on the flavonoid content of white tea remains scarce, making the need for a good flavonoid purification process for white tea even more important. This study compared the adsorption and desorption performance of five types of macroporous resins: D101, HP20, HPD500, DM301, and AB-8. Among the tested resins, AB-8 was selected based on its best adsorption and desorption performance to investigate the static adsorption kinetics and dynamic adsorption-desorption purification of white tea flavonoids. The optimal purification process was determined: adsorption temperature 25 °C, crude tea flavonoid extract pH 3, ethanol concentration 80 %, sample loading flow rate and eluent flow rate 1.5 BV/min, and eluent dosage 40 BV. The results indicated that the adsorption process followed pseudo-second-order kinetics. Under the above purification conditions, the purity of the total flavonoids in the purified white tea flavonoid increased from approximately 17.69 to 46.23 %, achieving a 2.61-fold improvement, indicating good purification results. The purified white tea flavonoid can be further used for nutraceutical and pharmaceutical applications.


Asunto(s)
Flavonoides , Resinas Sintéticas , Flavonoides/análisis , Adsorción , Resinas Sintéticas/química , Extractos Vegetales/química , Resinas de Plantas ,
20.
J Prosthet Dent ; 131(4): 705.e1-705.e7, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38262840

RESUMEN

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) removable dentures have become popular. However, evaluations of the effect of denture base-tooth offset (DTO) values on the trueness of artificial teeth are lacking. PURPOSE: The purpose of this in vitro study was to digitally measure the trueness of the artificial teeth of CAD-CAM dentures fabricated with additive manufacturing using different DTO values and to determine the most accurate DTO value. MATERIAL AND METHODS: Seven study groups were formulated based on different DTO values, and 6 maxillary complete dentures were assigned to each group (n=42). A design software program was used to export the monoblock denture as control, the artificial teeth, and 7 different designs of denture bases with DTO values of 0.00, 0.01, 0.03, 0.05, 0.10, 0.15, and 0.20 mm. Denture bases were printed in denture base resin (Denture base RP; formlabs), artificial teeth were printed in tooth-shade resin (Denture teeth A2; formlabs), and both were then assembled and polymerized together. The dentures were scanned (InEos X5; Dentsply Sirona), scan data were imported in a measuring software program (GOM Inspect; GOM GmbH), and registration using local best fit was performed to align data. Color-coded maps for the surface comparison of each denture with the control denture scan were generated. Fitting center points were constructed for each artificial tooth, which were compared with their corresponding points on the data of the control scan. Multiple pairwise comparisons were performed after 1-way ANOVA to quantify and statistically evaluate the deviation values (α=.05). RESULTS: The 0.10-mm DTO group showed the lowest values when comparing artificial tooth deviations both individually and as types. On comparing the average deviations, statistically significant differences were identified among the 7 groups (P<.001). A nonstatistically significant difference was identified when the 0.10- and 0.05-mm DTO groups were compared. Lower deviation values were found in the premolars compared with the molars, in the incisors compared with the canines, and in posterior artificial teeth compared with anterior teeth. CONCLUSIONS: The 0.10-mm DTO value showed the highest trueness for the artificial teeth compared with the other DTO values tested in this study. The 0.05-mm DTO value is an alternative to the 0.10-mm DTO value for CAD-CAM dentures constructed by additive manufacturing. Anterior teeth of a CAD-CAM denture showed higher deviation values compared with posterior teeth.


Asunto(s)
Bases para Dentadura , Diente Artificial , Diseño Asistido por Computadora , Dentadura Completa , Maxilar , Resinas Sintéticas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA