J Electrocardiol ; 86: 153776, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39146688

RESUMEN

Seldom are reports of phase 4 block or bradycardia-dependent conduction block in atrial tissue found in the literature. Here, we describe the case of a patient with sick sinus syndrome with Torsade de Pointes who, following the implantation of a double-chamber implantable cardioverter defibrillator, developed intra-atrial bradycardia-dependent conduction block. The patient's optimal pacing parameters were achieved by raising the rate.


Asunto(s)
Bradicardia , Desfibriladores Implantables , Electrocardiografía , Humanos , Desfibriladores Implantables/efectos adversos , Bradicardia/terapia , Bradicardia/etiología , Masculino , Síndrome del Seno Enfermo/terapia , Persona de Mediana Edad , Anciano , Bloqueo Interauricular , Torsades de Pointes/etiología
2.
Acta Med Indones ; 56(2): 227-232, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39010770

RESUMEN

Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold  (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Electrocardiografía , Humanos , Femenino , Persona de Mediana Edad , Masculino , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Anciano , Síndrome del Seno Enfermo/terapia , Resultado del Tratamiento , Marcapaso Artificial , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología
3.
Int Heart J ; 65(4): 778-782, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39085116

RESUMEN

Empty sella syndrome (ESS) is characterized by the herniation of cerebrospinal fluid into the sella, which results in the enlargement of the sella and compression of the pituitary gland. ESS commonly accompanies pituitary dysfunction and abnormal secretion of one or more hormones, which manifests as symptoms like cold intolerance, fatigue, and memory impairment. However, the occurrence of sick sinus syndrome (SSS) in ESS has not been reported. A 66-year-old female patient was admitted to the hospital with complaints of dizziness and fatigue. Electrocardiogram (ECG) revealed sinus arrest, junctional escape rhythm, and a heart rate of 40 bpm. Then, the patient was diagnosed with SSS. Thyroid function test indicated decreased thyroxine levels and slightly elevated thyroid-stimulating hormone levels. Additionally, hyposecretion of cortisol and insulin-like growth factors was observed. Magnetic resonance imaging of the pituitary gland confirmed the diagnosis of ESS. The patient was treated with hydrocortisone and euthyrox, relieving the symptoms of dizziness and fatigue. Thyroid function tests during the follow-up period showed normal hormone levels, and ECG examination revealed no abnormalities.


Asunto(s)
Electrocardiografía , Síndrome de Silla Turca Vacía , Síndrome del Seno Enfermo , Humanos , Síndrome de Silla Turca Vacía/complicaciones , Síndrome de Silla Turca Vacía/diagnóstico , Femenino , Anciano , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/complicaciones , Imagen por Resonancia Magnética , Hidrocortisona/uso terapéutico
4.
Pacing Clin Electrophysiol ; 47(8): 1038-1048, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38923028

RESUMEN

BACKGROUND: New antithrombotic medications and improved stent designs have reduced branch occlusion, although the sino-atrial nodal artery (SANA) may still be occluded after a percutaneous coronary intervention (PCI), causing sinus node dysfunction (SND). Ischemic sinus nodes are usually asymptomatic but can cause sinus arrest sometimes requiring pacemaker placement. In rare cases, junctional escape rhythms, a manifestation of sinus exit blocks after PCI, can predict cardiogenic shock. METHODS: We present a case study of a patient who underwent bifurcation PCI to the LMCA to the LCX but subsequently developed cardiogenic shock as a result of SND, a junctional escape rhythm required substantial inotropic support. This case offers an exemplification of a sparsely documented, yet infrequent manifestation of iatrogenic ischemic SND at an unorthodox site, the confluence of the LMCA-LCX. In addition, we conducted a comprehensive analysis of 22 scholarly works pertaining to the subject of sinus node dysfunction (SND) subsequent to PCI resulting from ischemia caused by stenosis or occlusion of the SANA. RESULTS: RCA was responsible for 96.1% of SND cases, whereas LCX was responsible for 3.9%. SND was asymptomatic in 49.3% of cases and junctional escape rhythm in 37.6% of symptomatic cases. 28% needed a temporary transvenous pacemaker, while 7.8% needed a permanent one. Interventional management recanalized the SANA in 5.2% of patients, restoring flow. CONCLUSION: Transient sino-atrial node ischemia after PCI can cause acute SND. Before stent implantation, doctors should consider SND. Complete plaque evaluation around the SANA is needed before choosing the best PCI procedure.


Asunto(s)
Intervención Coronaria Percutánea , Humanos , Masculino , Síndrome del Seno Enfermo/terapia , Anciano
5.
Curr Vasc Pharmacol ; 22(4): 251-265, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38920075

RESUMEN

INTRODUCTION: Permanent pacemakers are an established treatment for sick sinus syndrome and high-grade atrioventricular block. Permanent cardiac pacemaker implantations may damage the myocardium. OBJECTIVE: This study evaluated markers of myocardial injury, oxidative stress and inflammation in elderly patients with permanent pacemaker implantations. METHODS: Various markers were measured at 1, 2, 3 and 4 months after permanent pacemaker implantations in elderly patients. RESULTS: The levels of high-sensitivity troponin T (hsTnT), lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1), malondialdehyde-modified low-density lipoprotein (MDA-LDL), oxidized low-density lipoprotein (OX-LDL), tumour necrosis factor-α (TNF-α), toll-like receptor 4 (TLR4) and nuclear factor-kappa B (NF-κB) were increased in 2-month group compared with control and 1- month groups (P<0.001), and were further increased at 4-month group compared with 2- and 3- month groups after pacemaker implantations (P<0.001). Patients with dual-chamber pacemakers had higher levels of hsTnT, LOX-1, MDA-LDL, OX-LDL, TNF-α, TLR4 and NF-κB than patients with single chamber pacemakers (P<0.001). Patients who underwent the pacemakers with the active fixation leads had raised levels of hsTnT, LOX-1, MDA-LDL, OX-LDL, TNF-α, TLR4 and NF-κB compared patients with pacemakers using the passive fixation leads (P<0.001). Myocardial blood flows in 3-month and 4-month groups were lower than 1-month and 2-month groups (P<0.001). CONCLUSION: Levels of hsTnT, LOX-1, MDA-LDL, OX-LDL, TNF-α, TLR4 and NF-κB were elevated in elderly patients with permanent pacemaker implantations and the activations of oxidative stress and pro-inflammatory signalling pathways may be associated with myocardial damages and ischemia after pacemaker implantations in elderly patients.


Asunto(s)
Biomarcadores , Lipoproteínas LDL , FN-kappa B , Estrés Oxidativo , Marcapaso Artificial , Receptores Depuradores de Clase E , Transducción de Señal , Receptor Toll-Like 4 , Factor de Necrosis Tumoral alfa , Humanos , Receptor Toll-Like 4/sangre , Receptor Toll-Like 4/metabolismo , Masculino , FN-kappa B/metabolismo , FN-kappa B/sangre , Anciano , Femenino , Receptores Depuradores de Clase E/sangre , Factor de Necrosis Tumoral alfa/sangre , Lipoproteínas LDL/sangre , Marcapaso Artificial/efectos adversos , Biomarcadores/sangre , Anciano de 80 o más Años , Factores de Tiempo , Factores de Edad , Estimulación Cardíaca Artificial/efectos adversos , Malondialdehído/sangre , Mediadores de Inflamación/sangre , Cardiotoxicidad , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/sangre , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/fisiopatología , Miocardio/metabolismo , Miocardio/patología , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/sangre , Bloqueo Atrioventricular/diagnóstico
6.
Am J Case Rep ; 25: e943944, 2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38879750

RESUMEN

BACKGROUND Compression of the vagus nerve by a pharyngeal mass is a well-documented condition that can result in sinus node dysfunction (SND). However, there is scarce literature on extrinsic vagal nerve compression from a tonsillar abscess. CASE REPORT A 59-year-old woman with a history of asthma and chronic throat discomfort presented to the Emergency Department with bradycardia, palpitations, and voice changes. Following a shellfish allergy hospitalization, an otolaryngology evaluation revealed an enlarged right tonsil, recommending tonsillectomy, but scheduling challenges persisted. The patient reported mild throat pain, dysphagia, hoarseness, rhinorrhea, and exertional dyspnea and was admitted for the evaluation of peritonsillar mass. She was found to be bradycardic with a heart rate of 47, with an electrocardiogram revealing SND. Albuterol and ipratropium nebulizers, as well as dexamethasone and pantoprazole, were initiated. With this treatment, the patient symptomatically improved with a new heart rate of 68. She was discharged with outpatient appointments, but was unfortunately lost to follow-up. CONCLUSIONS This case reveals sinus node dysfunction resulting from extrinsic vagal nerve compression by a tonsillar abscess. Pressure on the vagus nerve can trigger bradycardia and low blood pressure, possibly due to compensatory overfiring of afferent vagal nerve signals from local mass effect. Early recognition and antibiotic treatment are essential to prevent cardiac complications. Clinicians must remain vigilant for such extrinsic causes, particularly in patients with chronic sore throat and cardiac symptoms. Further research and case reports are needed to deepen our understanding of this rare yet significant association.


Asunto(s)
Síndrome del Seno Enfermo , Humanos , Femenino , Persona de Mediana Edad , Síndrome del Seno Enfermo/terapia , Absceso Peritonsilar/complicaciones , Síndromes de Compresión Nerviosa/etiología , Nervio Vago
7.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38938169

RESUMEN

AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. METHODS AND RESULTS: Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72-0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71-0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSION: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.


Asunto(s)
Fibrilación Atrial , Estimulación Cardíaca Artificial , Frecuencia Cardíaca , Ataque Isquémico Transitorio , Marcapaso Artificial , Síndrome del Seno Enfermo , Accidente Cerebrovascular , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Anciano , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ataque Isquémico Transitorio/prevención & control , Ataque Isquémico Transitorio/epidemiología , Persona de Mediana Edad , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Incidencia , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Acelerometría , Anciano de 80 o más Años
8.
Card Electrophysiol Clin ; 16(2): 139-142, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749632

RESUMEN

This case report discusses a 42-year-old male with dextro-transposition of the great arteries (D-TGA) status post Mustard repair and sick sinus syndrome status post dual-chamber pacemaker implant, who developed symptomatic superior vena cava (SVC) baffle stenosis. He was treated with a combined pacemaker extraction and subsequent SVC baffle stenting. The case highlights the complexities of treating SVC baffle stenosis in the presence of cardiac implantable devices and demonstrates the efficacy of this combined approach. Furthermore, the authors delve into the intricacies of D-TGA, its surgical history, and the long-term complications associated with atrial switch procedures.


Asunto(s)
Remoción de Dispositivos , Marcapaso Artificial , Stents , Transposición de los Grandes Vasos , Humanos , Transposición de los Grandes Vasos/cirugía , Masculino , Adulto , Marcapaso Artificial/efectos adversos , Síndrome de la Vena Cava Superior/cirugía , Síndrome de la Vena Cava Superior/etiología , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/cirugía
9.
Medicine (Baltimore) ; 103(16): e37543, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640303

RESUMEN

BACKGROUND: Tachycardia-bradycardia syndrome (TBS) is a subtype of sick sinus syndrome characterized by prolonged sinus pause (≥3 s) following termination of tachyarrhythmias, primarily atrial fibrillation (AF). There is controversy regarding whether the long-term prognosis of AF ablation is superior to pacemaker implantation. This study aimed to compare the effects of AF ablation and pacemaker therapy in patients with TBS. METHODS: We conducted a comprehensive search of electronic databases, including PubMed, Cochrane, EmBase, Web of Science, and Chinese BioMedical, up until December 1, 2023. We included studies that reported the effects of AF ablation vs pacemaker therapy in patients with TBS. From this search, we identified 5 studies comprising 843 participants with TBS who underwent catheter AF ablation or pacemaker therapy. RESULTS: Our meta-analysis revealed that AF ablation and pacemaker therapy had similar effects on cardiovascular death (odds ratio [OR] = 0.62 and 95% confidence interval [CI]: 0.14-2.65), procedural complications (OR = 1.53 and 95% CI: 0.67-3.48), and cardiovascular rehospitalization (OR = 0.57 and 95% CI: 0.26-1.22). However, AF ablation provided greater benefits than pacemaker therapy in terms of all-cause mortality (OR = 0.37 and 95% CI: 0.17-0.82), thromboembolism (OR = 0.25 and 95% CI: 0.12-0.49), stroke (OR = 0.28 and 95% CI: 0.13-0.57), heart failure (OR = 0.27 and 95% CI: 0.13-0.56), freedom from AF (OR = 23.32 and 95% CI: 7.46-72.92), and prevention of progression to persistent AF (OR = 0.12 and 95% CI: 0.06-0.24). Furthermore, AF ablation resulted in a reduced need for antiarrhythmic agents (OR = 0.21 and 95% CI: 0.08-0.59). CONCLUSION: AF ablation can effectively reduce the risk of all-cause mortality, thromboembolism, stroke, heart failure, and progression to persistent AF in patients with TBS. Additionally, it may eliminate the need for further pacemaker therapy in most cases after ablation. Therefore, AF ablation is considered superior to pacemaker therapy in the management of patients with TBS.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Marcapaso Artificial , Humanos , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Bradicardia/terapia , Taquicardia/terapia , Síndrome del Seno Enfermo/terapia
10.
J Cardiovasc Electrophysiol ; 35(6): 1232-1234, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38534004

RESUMEN

INTRODUCTION: Pacemaker implantation can be challenging in patients with congenital heart disease. METHODS AND RESULTS: In a patient with Ebstein disease and symptomatic sinus node dysfunction, despite multiple attempts, the Micra® pacemaker could not be implanted in the severely dilated right ventricle. In that context, and after iodine injection to confirm the appropriate location, the Micra® pacemaker was successfully implanted in the right appendage at the first attempt. CONCLUSION: Despite the recent development of dedicated dual-chamber leadless pacemaker, to the best of our knowledge, this case is the first off-label Micra® implantation in a right appendage.


Asunto(s)
Apéndice Atrial , Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Apéndice Atrial/fisiopatología , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/fisiopatología , Síndrome del Seno Enfermo/diagnóstico , Anomalía de Ebstein/cirugía , Anomalía de Ebstein/fisiopatología , Resultado del Tratamiento , Masculino , Diseño de Equipo
11.
Medicina (Kaunas) ; 60(3)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38541230

RESUMEN

Background and Objectives: Atrioventricular (AV) dyssynchrony as well as atrial and ventricular pacing affect left atrial (LA) function. We conducted a study evaluating the effect of atrial and ventricular pacing on LA morphological and functional changes after dual-chamber pacemaker implantation. Materials and Methods: The study prospectively enrolled 121 subjects who had a dual-chamber pacemaker implanted due to sinus node disease (SND) or atrioventricular block (AVB). Subjects were divided into three groups based on indication and pacemaker programming: (1) SND DDDR 60; (2) AVB DDD 60 and (3) AVB DDD 40. Subjects were invited to one- and three-month follow-up visits. Three subsets based on pacing burden were analyzed: (1) high atrial (A) low ventricular (V); (2) high A, high V and (3) low A, high V. LA function was assessed from volumetric parameters and measured strains from echocardiography. Results: The high A, low V group consisted of 38 subjects; while high A, high V had 26 and low A, high V had 23. A significant decrease in reservoir and contractile LA strain parameters were only observed in the high A, low V pacing group after three months (reservoir 25.9 ± 10.3% vs. 21.1 ± 9.9%, p = 0.003, contractile -14.0 ± 9.0% vs. -11.1 ± 7.8, p = 0.018). While the re-established atrioventricular synchrony in the low A, high V group maintained reservoir LA strain at the baseline level after three months (21.4 ± 10.4% vs. 22.5 ± 10.4%, p = 0.975); in the high A, high V group, a further trend to decrease was noted (20.3 ± 8.9% vs. 18.7 ± 8.3%, p = 0.231). Conclusions: High atrial pacing burden independently of atrioventricular dyssynchrony and ventricular pacing impairs LA functional and morphological parameters. Changes appear soon after pacemaker implantation and are maintained.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Atrios Cardíacos , Síndrome del Seno Enfermo/terapia , Bloqueo Atrioventricular/terapia
12.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38552167

RESUMEN

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Asunto(s)
Marcapaso Artificial , Humanos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Electrodos Implantados , Bloqueo Atrioventricular/terapia , Síndrome del Seno Enfermo/terapia
13.
J Emerg Med ; 66(4): e492-e502, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38453595

RESUMEN

BACKGROUND: Transvenous pacemaker placement is an integral component of therapy for severe dysrhythmias and a core skill in emergency medicine. OBJECTIVE: This narrative review provides a focused evaluation of transvenous pacemaker placement in the emergency department setting. DISCUSSION: Temporary cardiac pacing can be a life-saving procedure. Indications for pacemaker placement include hemodynamic instability with symptomatic bradycardia secondary to atrioventricular block and sinus node dysfunction; overdrive pacing in unstable tachydysrhythmias, such as torsades de pointes; and failure of transcutaneous pacing. Optimal placement sites include the right internal jugular vein and left subclavian vein. Insertion first includes placement of a central venous catheter. The pacing wire with balloon is then advanced until electromechanical capture is obtained with the pacer in the right ventricle. Ultrasound can be used to guide and confirm lead placement using the subxiphoid or modified subxiphoid approach. The QRS segment will demonstrate ST segment elevation once the pacing wire tip contacts the endocardial wall. If mechanical capture is not achieved with initial placement of the transvenous pacer, the clinician must consider several potential issues and use an approach to evaluating the equipment and correcting any malfunction. Although life-saving in the appropriate patient, complications may occur from central venous access, right heart catheterization, and the pacing wire. CONCLUSIONS: An understanding of transvenous pacemaker placement is essential for emergency clinicians.


Asunto(s)
Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Bradicardia/etiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicaciones , Síndrome del Seno Enfermo/terapia
16.
Intern Med ; 63(15): 2143-2147, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38171857

RESUMEN

Sinus arrest and inappropriate sinus bradycardia are sinus node dysfunction (SND), which cause loss of consciousness. Cardiac pacing is recommended in patients with symptoms, such as syncope or dizziness. Several conditions can induce these arrhythmias; however, whether or not intracranial infectious diseases, such as herpes simplex encephalitis (HSE), can cause secondary SND is unclear. We encountered a patient with sinus arrest and transient sinus bradycardia associated with HSE. Since cardiac pause was never monitored and the bradycardia improved after HSE treatment, HSE was suspected to be the cause of SND. Although the underlying mechanisms have not yet been completely elucidated, HSE may cause secondary SND.


Asunto(s)
Encefalitis por Herpes Simple , Humanos , Encefalitis por Herpes Simple/complicaciones , Encefalitis por Herpes Simple/diagnóstico , Encefalitis por Herpes Simple/diagnóstico por imagen , Masculino , Bradicardia/etiología , Bradicardia/diagnóstico , Paro Sinusal Cardíaco/etiología , Paro Sinusal Cardíaco/diagnóstico , Femenino , Electrocardiografía , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/complicaciones , Persona de Mediana Edad
17.
Dis Mon ; 70(2): 101637, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37690863

RESUMEN

Sudden alterations in the heart rate may be associated with diverse symptoms. Sinus node dysfunction (SND), also known as sick sinus syndrome, is a sinoatrial (SA) node disorder. SND is primarily caused by the dysfunction of the pacemaker, as well as impaired impulse transmission resulting in a multitude of abnormalities in the heart rhythms, such as bradycardia-tachycardia, atrial bradyarrhythmias, and atrial tachyarrhythmias. The transition from bradycardia to tachycardia is generally referred to as "tachy-brady syndrome" (TBS). Although TBS is etiologically variable, the manifestations remain consistent throughout. Abnormal heart rhythms have the propensity to limit tissue perfusion resulting in palpitations, fatigue, lightheadedness, presyncope, and syncope. In this review, we examine the physiology of tachy-brady syndrome, the practical approach to its diagnosis and management, and the role of adenosine in treating SND.


Asunto(s)
Bradicardia , Síndrome del Seno Enfermo , Humanos , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/terapia , Bradicardia/diagnóstico , Bradicardia/etiología , Nodo Sinoatrial , Taquicardia/complicaciones , Taquicardia/diagnóstico , Electrofisiología
18.
Ann Noninvasive Electrocardiol ; 29(1): e13099, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37997537

RESUMEN

BACKGROUND: The temporary pacing lead routinely is placed into right ventricular (RV), which pose a risk of dislocation and cardiac perforation. OBJECTIVE: We aim to evaluate the effectiveness and safety of temporary transvenous cardiac pacing (TTCP) leads placement into the coronary sinus vein (CSV) in patients with sick sinus syndrome (SSS). METHODS: We investigated patients with SSS who underwent TTCP lead placement into the CSV under the guidance of X-ray between January 2013 and May 2023. Patients were randomly divided into two groups: RV group (n = 33) and CSV group (n = 22). The ordinary passive bipolar electrodes were applied in both groups. In RV groups, electrodes were placed into RV. In CSV group, electrodes were placed into CSV. We evaluated the operation duration, fluoroscopic exposure, first-attempt success rate of leads placement, pacing threshold, success rate of leads placement, rate of leads displacement, and complications. RESULTS: Compared with that in RV group, the procedure time, fluoroscopic exposure was significantly prolonged, while the first-attempt success rate of lead placement was obviously increased in CSV group (both p < .05). Compared with that in RV group, the rate of leads displacement is lower in CSV group (both p < .05). There were three patients occurred cardiac perforation in RV group, but no cardiac perforation was reported in CSV group (p > .05). CONCLUSION: TTCP leads placement into the CSV is an effective and safe strategy in patients with SSS. It indicates a high rate of pacing effectiveness with low device replacement and complication rates.


Asunto(s)
Seno Coronario , Marcapaso Artificial , Humanos , Seno Coronario/diagnóstico por imagen , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Síndrome del Seno Enfermo/terapia , Electrocardiografía
19.
Pacing Clin Electrophysiol ; 46(12): 1465-1471, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37910470

RESUMEN

BACKGROUND: Permanent pacemaker (PPM) implantation is a well-established treatment for symptomatic sinus node dysfunction (SND). The optimal timing of this intervention is unclear, with atrioventricular blocks often prioritized in resource stressed waiting lists due to mortality concerns. METHODS: Mortality data was compared between patients receiving elective outpatient (OP) PPM implantation, and those presenting to hospital for urgent inpatient (IP) management for symptomatic SND. Survival analysis was conducted using Kaplan-Meier plots and compared using the log-rank test. Univariable and multivariable Cox regression, as well as propensity score matching analyses were performed to assess the prognostic effect on 30-day and 1-year all-cause mortality of inpatient implant. RESULTS: Of the 1269 patients identified with isolated SND, 740 (58%) had PPMs implanted on an OP and 529 (42%) on an IP basis. Mortality was significantly worse in patients where management was driven by hospital admission on an urgent basis (Log-Rank χ2 = 21.6, p < 0.001) and remained an independent predictor of 1-year all-cause mortality (HR 3.40, 95% CI 1.97-5.86, p < 0.001) on multivariable analysis. CONCLUSIONS: SND is predominantly a disease associated with ageing and comorbid populations, where avoidance of deconditioning, hospitalization acquired infections, and polypharmacy is advantageous. Admission avoidance is therefore the preferable strategy.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Síndrome del Seno Enfermo/terapia , Marcapaso Artificial/efectos adversos , Pacientes Ambulatorios , Hospitalización
20.
Arch Cardiol Mex ; 93(4): 398-404, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37972358

RESUMEN

OBJECTIVE: The objective of the study was to establish the prognostic value of CSNRT regarding the necessity for pacemaker implantation in patients with atrial flutter (AFL) post-ablation. METHODS: This prospective cohort study, conducted at the National Institute of Cardiology "Ignacio Chavez" in Mexico City, assessed patients who had undergone ablation procedures to correct AFL, posterior to which an autonomic blockade was performed, and CSNRT was measured. RESULTS: The sample for this investigation was 40 patients. These were subdivided into two study groups depending on their requirement of pacemaker implant post-ablation (Pacemaker P, No Pacemaker NP). Sinus node (SN) dysfunction was diagnosed in 13 (32.5%) of the 40 participants, 10 (71.43%) of which required a pacemaker implant, while only 4 participants (28.57%) with normal SN function required pacemakers. Ten out of the 14 patients (71.43%) who required a pacemaker had an elevated CSNRT > 500 ms (p ≤ 0.01). Post-ablation CSNRT mean was 383.54 ms ± 67.96 ms in the NP group versus 1972.57 ms ± 3423.56 ms in the P group. Furthermore, SN pause in the P group had a mean of 1.86 s ± 0.96 s versus the NP group with 1.196 s ± 0.52 s. CONCLUSION: CSNRT has the potential to be a quantitative prognostic tool for the assessment of future pacemaker implants in patients with AFL post-ablation. This could aid in the timely diagnosis of sinus node dysfunction, which could, in the long run, result in the reduction of cardiac functional capacity loss due to cardiac remodeling.


OBJETIVO: Establecer el valor pronóstico del TRNSC basado en la necesidad de marcapasos en pacientes diagnosticados con aleteo atrial, pos-ablación. MÉTODOS: Este cohorte prospectivo, realizado en el Instituto Nacional de Cardiología "Ignacio Chávez" en la Ciudad de México, evaluó pacientes sometidos a ablación para corregir el aleteo atrial; se midió el TRNSC post bloqueo autonómico. RESULTADOS: La muestra de 40 pacientes se subdividió en 2 grupos según su requerimiento de marcapasos posterior a la ablación (P y NP). Se diagnosticó disfunción del nodo sinusal en 13 participantes (32.5%), de los cuales 10 (71.43%) requirieron marcapasos en comparación a 4 (28.57%) con función normal. En el grupo P la pausa del nodo sinusal post-ablación tuvo una media de 1.86 ± 0.96 s versus el grupo NP con 1.196 ± 0.52 s. En relación con el TRNSC, el grupo NP tuvo una media de 383.54 ± 67.96 ms vs. 1972.57 ± 3423.56 ms en el grupo P. 10 pacientes (25%) obtuvieron un TRNSC > 500 ms, de los cuales 100% requirieron marcapasos; de los 14 pacientes que requirieron marcapasos 10 (71.43%) tenían un TRNSC elevado (p ≤ 0.01). CONCLUSIONES: El TRNSC tiene el potencial de ser una herramienta de pronóstico cuantitativo para la necesidad de futuros implantes de marcapasos en pacientes con disfunción del nodo sinusal, resultado de aleteo atrial pos-ablación. Esto podría ayudar a diagnosticar más temprano una disfunción del nodo sinusal, resultando en la reducción de la pérdida a largo plazo de la función cardíaca como efecto de la remodelación.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Marcapaso Artificial , Humanos , Nodo Sinoatrial/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Estudios Prospectivos , Electrocardiografía , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/terapia , Fibrilación Atrial/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA