Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 306
Filtrar
2.
J Cardiovasc Electrophysiol ; 35(7): 1440-1449, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38757370

RESUMEN

INTRODUCTION: The accuracy of surface ECG algorithms for predicting the origin of outflow tract ventricular arrhythmias (OT-VAs) might be questioned. Intracardiac electrograms recorded at anatomic landmarks could provide new predictive insights. We aim to evaluate the efficacy of a novel criterion utilizing the activation pattern of the coronary sinus (CS) in localizing OT-VAs, including VAs originating from the right ventricular outflow tract (RVOT), endocardial left ventricular outflow tract (Endo-LVOT), and epicardial left ventricular outflow tract (Epi-LVOT). METHODS: We measured the ventricular activation time of the mitral annulus (MA) from the onset of the earliest QRS complex of VAs to the initial deflection over the isoelectric line at local signals, namely the QRS-MA interval. The activation at 3 and 12 o'clock of the MA was recorded as the QRS-MA3 and QRS-MA12 intervals, respectively. Their predictive values were compared to previous ECG algorithms. RESULTS: A total of 68 patients with OT-VAs were enrolled (51 for development and 17 for validation). From early to late, the ventricular activation sequences at MA12 were as follows: Epi-LVOT, Endo-LVOT, and RVOT. In LBBB morphology OT-VAs, the QRS-MA12 interval was significantly earlier for LVOT origins than RVOT origins. In the combined cohort of development and validation cohort, a cut-off value of ≤10 ms predicted the LVOT origin with a sensitivity of 100% and specificity of 78%. The QRS-MA12 interval ≤ -24 ms additionally predicted epicardial LVOT sites of origin. CONCLUSIONS: The QRS-MA interval could accurately differentiate the OT-VAs localization.


Asunto(s)
Potenciales de Acción , Seno Coronario , Electrocardiografía , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Humanos , Seno Coronario/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Algoritmos , Técnicas Electrofisiológicas Cardíacas , Reproducibilidad de los Resultados , Factores de Tiempo , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Adulto , Diagnóstico Diferencial
3.
Int J Cardiovasc Imaging ; 40(5): 1159-1160, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38703291

RESUMEN

Unroofed sinus is categorized into four subtypes. Types I and II represent complete unroofing with or without an LSVC, respectively [1]. Types III and IV are partial unroofing involving the mid-CS (type III) or near the LA appendage and left superior pulmonary vein (type IV) [1]. CT has advantages over echocardiography in detection of this anomaly (illustrated in this case) as well as in precise delineation of defect and associated findings (presence or absence of LSVC). Short axis reconstructions at the level of CS are helpful in diagnosis. Considerations for repair include location of CS defect, presence of LSVC and other abnormalities as well as comorbidity risks [2].


Asunto(s)
Seno Coronario , Valor Predictivo de las Pruebas , Humanos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Seno Coronario/anomalías , Seno Coronario/diagnóstico por imagen , Seno Coronario/fisiopatología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Flebografía/métodos , Vena Cava Superior/anomalías , Vena Cava Superior/diagnóstico por imagen
4.
Circ Arrhythm Electrophysiol ; 17(6): e012486, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38690652

RESUMEN

BACKGROUND: 12,13-dihydroxy-9Z-octadecenoic acid (12,13-diHOME) has shown potential in protecting against heart disease, but its relationship with atrial fibrillation (AF) remains unknown. METHODS: Coronary sinus (CS) and femoral vein blood samplings were synchronously collected from AF and non-AF subjects (paroxysmal supraventricular tachycardia or idiopathic premature ventricular complexes) who underwent catheter ablation. First, untargeted metabolomic profiling was performed in a discovery cohort (including 12 AF and 12 non-AF subjects) to identify the most promising CS or femoral vein metabolite. Then, the selected metabolite was further measured in a validation cohort (including 119 AF and 103 non-AF subjects) to confirm its relationship with left atrium remodeling and 1-year postablation recurrence of AF. Finally, the biological function of the selected metabolite was validated in a rapid-paced cultured HL-1 atrial cardiomyocytes model. RESULTS: Metabolomic analysis identified CS 12,13-diHOME as the most pronounced change metabolite correlated with left atrium remodeling in the discovery cohort. In the validation cohort, CS 12,13-diHOME was significantly lower in patients with AF than non-AF controls (84.32±20.13 versus 96.24±23.56 pg/mL; P<0.01), and associated with worse structural, functional, and electrical remodeling of left atrium. Multivariable regression analyses further demonstrated that decreased CS 12,13-diHOME was an independent predictor of 1-year postablation recurrence of AF (odds ratio, 0.754 [95% CI, 0.648-0.920]; P=0.005). Biological function validations showed that 12,13-diHOME treatment significantly protect the cell viability, improved the expression of MHC (myosin heavy chain) and Cav1.2 (L-type calcium channel α1c), and attenuated mitochondrial damage in the rapid-paced cultured HL-1 cardiomyocytes model. CONCLUSIONS: CS metabolite 12,13-diHOME is decreased in patients with AF and can serve as a novel biomarker for left atrium remodeling.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Biomarcadores , Ablación por Catéter , Seno Coronario , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/metabolismo , Fibrilación Atrial/diagnóstico , Humanos , Masculino , Femenino , Biomarcadores/sangre , Biomarcadores/metabolismo , Persona de Mediana Edad , Seno Coronario/metabolismo , Seno Coronario/fisiopatología , Metabolómica , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/patología , Animales , Anciano , Estudios de Casos y Controles , Recurrencia , Función del Atrio Izquierdo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/metabolismo , Valor Predictivo de las Pruebas
5.
Eur J Heart Fail ; 26(4): 1065-1077, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38606485

RESUMEN

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.


Asunto(s)
Seno Coronario , Estudios de Factibilidad , Atrios Cardíacos , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Femenino , Masculino , Volumen Sistólico/fisiología , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Seno Coronario/fisiopatología , Resultado del Tratamiento , Persona de Mediana Edad , Ecocardiografía/métodos , Calidad de Vida , Cateterismo Cardíaco/métodos , Estudios Prospectivos , Función Ventricular Izquierda/fisiología , Estudios de Seguimiento , Hemodinámica/fisiología
7.
J Appl Physiol (1985) ; 136(5): 1157-1169, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38511210

RESUMEN

The coronary sinus reducer (CSR) is an emerging medical device for treating patients with refractory angina, often associated with myocardial ischemia. Patients implanted with CSR have shown positive outcomes, but the underlying mechanisms are unclear. This study sought to understand the mechanisms of CSR by investigating its effects on coronary microcirculation hemodynamics that may help explain the therapy's efficacy. We applied a validated computer model of the coronary microcirculation to investigate how CSR affects hemodynamics under different degrees of coronary artery stenosis. With moderate coronary stenosis, an increase in capillary transit time (CTT) [up to 69% with near-complete coronary sinus (CS) occlusion] is the key change associated with CSR. Because capillaries in the microcirculation can still receive oxygenated blood from the upstream artery with moderate stenosis, the increase in CTT allows more time for the exchange of gases and nutrients, aiding tissue oxygenation. With severe coronary stenosis; however, the redistribution of blood draining from the nonischemic region to the ischemic region (up to 96% with near-complete CS occlusion) and the reduction in capillary flow heterogeneity are the key changes associated with CSR. Because blood draining from the nonischemic region is not completely devoid of O2, the redistribution of blood to the capillaries in the ischemic region by CSR is beneficial especially when little or no oxygenated blood reaches these capillaries. This simulation study provides insights into the mechanisms of CSR in improving clinical symptoms. The mechanisms differ with the severity of the upstream stenosis.NEW & NOTEWORTHY Emerging coronary venous retroperfusion treatments, particularly coronary sinus reducer (CSR) for refractory angina linked to myocardial ischemia, show promise; however, their mechanisms of action are not well understood. We find that CSR's effectiveness varies with the severity of coronary stenosis. In moderate stenosis, CSR improves tissue oxygenation by increasing capillary transit time, whereas in severe stenosis, it redistributes blood from nonischemic to ischemic regions and reduces capillary flow heterogeneity.


Asunto(s)
Simulación por Computador , Circulación Coronaria , Seno Coronario , Hemodinámica , Microcirculación , Isquemia Miocárdica , Humanos , Seno Coronario/fisiopatología , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/metabolismo , Circulación Coronaria/fisiología , Hemodinámica/fisiología , Microcirculación/fisiología , Estenosis Coronaria/fisiopatología , Modelos Cardiovasculares
9.
Can J Cardiol ; 38(3): 376-383, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34968714

RESUMEN

BACKGROUND: Refractory angina is a debilitating condition that affects the quality of life of patients worldwide, who after exhausting standard available therapies are regarded as "no option" patients. Recently, CS (coronary sinus) reducer (Neovasc Reducer) implantation became available and is gaining popularity in the treatment of refractory angina. The effectiveness of this therapy was demonstrated in 1 randomised sham-control trial and numerous uncontrolled prospective studies entailing several hundred patients altogether. We performed a meta-analysis to incorporate the data and elucidate its efficacy and safety. METHODS: A meta-analysis of prospective studies assessing the effects of CS narrowing published in English to June 2021 was performed. The primary outcome was the proportion of patients improving ≥ 1 class in the Canadian Cardiovascular Society (CCS) angina score. Other end points included proportion of patients improving ≥ 2 CCS classes, procedural success, periprocedural complications, changes in Seattle Angina Questionnaire (SAQ) scores, and 6-minute walk test (6MWT). RESULTS: Data from 9 studies including 846 patients were included. An improvement of ≥ 1 CCS class occurred in 76% (95% confidence interval [CI] 73%-80%) of patients. Improvement of ≥ 2 CCS classes was observed in 40% of patients (95% CI 35%-46%). Procedure success was 98%, with no major and 3% nonmajor periprocedural complications. Post procedural SAQ scores and 6MWT distance were significantly improved. CONCLUSIONS: In patients suffering from angina refractory to medical and interventional therapies, Reducer implantation improves symptoms and quality of life with a low complication rate. These results are consistent in 1 randomised trial and multiple prospective uncontrolled studies.


Asunto(s)
Angina de Pecho , Seno Coronario , Implantación de Prótesis , Stents , Angina de Pecho/diagnóstico , Angina de Pecho/fisiopatología , Angina de Pecho/cirugía , Cateterismo Cardíaco/métodos , Seno Coronario/fisiopatología , Seno Coronario/cirugía , Diseño de Equipo , Humanos , Dolor Intratable/fisiopatología , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Resultado del Tratamiento
10.
Sci Rep ; 11(1): 16563, 2021 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-34400711

RESUMEN

The muscular discontinuities at the pulmonary vein (PV)-left atrial (LA) junction are known. The high-density mapping may help to find the muscular discontinuity. This study evaluated the efficacy of a partial antral ablation for a pulmonary vein (PV) isolation using high density (HD) mapping. A total of 60 drug-refractory atrial fibrillation (AF) patients undergoing catheter ablation were enrolled. The detailed activation mapping of each PV and LA junction was performed using an HD mapping system, and each PV segment's activation pattern was classified into a "directly-activated from the LA" or "passively-activated from an adjacent PV segment" pattern. The antral ablations were performed at the directly-activated PV segments only when the PV had "passively-activated segments". If the PV did not contain passively-activated segments, a circumferential antral ablation was performed on those PVs. A "successful partial antral ablation" was designated if the electrical isolation of targeted PV was achieved by ablation at the directly-activated segments only. If the isolation was not achieved even though all directly-activated segments were ablated, a "failed partial antral ablation" was designated, and then a circumferential ablation was performed. Among 240 PVs, passively-activated segments were observed in 140 (58.3%) PVs. Both inferior PVs had more passively-activated segments than superior PVs, and the posteroinferior segments had the highest proportion of passive activation. The overall rate of successful partial antral ablation was 85%. The atrial tachyarrhythmia recurrence was observed in 10 patients (16.7%) at 1-year. HD mapping allowed the evaluation of the detailed activation patterns of the PVs, and passively-activated segments may represent muscular discontinuity. Partial antral ablation of directly-activated antral segments only was feasible and effective for a PVI.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/métodos , Algoritmos , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/instrumentación , Estimulación Cardíaca Artificial , Seno Coronario/fisiopatología , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recurrencia , Cirugía Asistida por Computador/instrumentación
11.
Int J Cardiovasc Imaging ; 37(1): 291-303, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32860122

RESUMEN

Coronary sinus (CS) Reducer implantation improves myocardial perfusion and symptoms in patients with debilitating refractory angina. Its impact on myocardial remodeling remain uncertain. Aim of the present study was to assess possible impact of CS Reducer on myocardial systolic-diastolic deformation and microstructural remodeling, as assessed through cardiac magnetic resonance (CMR) feature tracking and mapping analysis. Twenty-eight consecutive patients with refractory angina underwent multiparametric stress CMR before and 4 months after CS Reducer implantation. Eight patients were excluded (6 for absence of inducible ischemia, 2 for artifacts). Modifications in 3D systo-diastolic myocardial deformation were evaluated using feature tracking analysis on rest cine images. Myocardial microstructural remodeling was assessed by native T1 mapping, cellular and matrix volume and extracellular volume fraction (ECV). Collaterally, the percentage of ischemic myocardium (ischemic burden %) and the myocardial perfusion reserve index (MPRI) were measured. After CS Reducer implantation, myocardial contractility improved (ejection fraction rose from 61 to 67%; p = 0.0079), along with longitudinal (from - 16 to - 19%; p = 0.0192) and circumferential strain (from - 18 to - 21%; p = 0.0017). Peak diastolic radial, circumferential and longitudinal strain rate did not change (p > 0.05), and no changes in native T1, ECV, cellular and matrix volume were observed. Myocardial perfusion improved, with a reduction of ischemic burden (13-11%; p = 0.0135), and recovery of intramural perfusion balance in segments with baseline ischemia (MPRi endocardial/epicardial ratio from 0.67 to 0.96; p = 0.0107). CS Reducer improves myocardial longitudinal and circumferential strain, without microstructural remodeling and no impact on diastolic proprieties.


Asunto(s)
Angina de Pecho/diagnóstico por imagen , Angina de Pecho/terapia , Cateterismo Cardíaco/instrumentación , Circulación Coronaria , Seno Coronario/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Imagen de Perfusión Miocárdica , Anciano , Angina de Pecho/fisiopatología , Cateterismo Cardíaco/efectos adversos , Seno Coronario/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
12.
Ann Noninvasive Electrocardiol ; 26(1): e12772, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32672409

RESUMEN

Catheter-based radiofrequency (RF) ablation targeting segments of the cardiac conduction system and/or selected regions of myocardium is an accepted treatment for many cardiac arrhythmias. On the other hand, while purposeful extension of RF ablation to include nearby cardiac neural elements, particularly epicardial ganglionated plexi (GP), remains a subject of ongoing study, inadvertent stimulation of such structures may occur during an otherwise conventional RF ablation procedure. Thus, asystolic pauses have been observed during RF ablation of left ventricular free-wall accessory pathways, slow AV node pathways, and the left superior pulmonary vein. In this report, sinus arrest occurred within 3.3 s of RF application (40 W at 50°C) along the coronary sinus roof for treatment of an atypical "slow-slow" atrioventricular nodal reentrant tachycardia. Energy delivery was immediately terminated, but asystole persisted for 4.7 s followed by sinus bradycardia. The procedure was temporarily halted, but later was successfully resumed. Given the latency from terminating RF to return of sinus node function, the sinus arrest was likely a centrally mediated reflex vagal response. Consequently, while parasympathetic ganglia near the CS os are believed to principally innervate the AV node, not the sinus node, our observation highlights the neural cross-communications that likely exist in this region of the heart.


Asunto(s)
Ablación por Catéter/métodos , Seno Coronario/fisiopatología , Taquicardia/cirugía , Adulto , Seno Coronario/diagnóstico por imagen , Ecocardiografía/métodos , Electrocardiografía/métodos , Femenino , Humanos
13.
J Cardiovasc Magn Reson ; 22(1): 73, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-33028350

RESUMEN

BACKGROUND: Although non-invasive assessment of coronary flow reserve (CFR) by cardiovascular magnetic resonance (CMR) provides prognostic information for patients with diabetes mellitus (DM), the incremental prognostic value of CMR-derived CFR remains unclear. PURPOSE: To evaluate the incremental prognostic value of CMR-derived CFR for patients with DM who underwent stress CMR imaging. MATERIALS AND METHODS: A total of 309 patients with type 2 DM [69 ± 9 years; 244 (78%) male] assessed between 2009 and 2019 were retrospectively reviewed. Coronary sinus blood flow (CSBF) was measured using phase contrast (PC) cine CMR. CFR was calculated as the CSBF during adenosine triphosphate infusion divided by that at rest. Major adverse cardiac events (MACE) were defined as death, acute coronary syndrome, hospitalization due to heart failure exacerbation, or sustained ventricular tachycardia. The incremental prognostic value of CFR over clinical and CMR variables was assessed by calculating the C-index and net reclassification improvement (NRI). RESULTS: During a median follow-up of 3.8 years, 42 patients (14%) experienced MACE. The annualized event rate was significantly higher among patients with CFR < 2.0, regardless of the presence of late gadolinium enhancement (LGE) (1.4% vs. 9.8%, p = 0.011 in the LGE (-) group; 1.8% vs. 16.9%, p < 0.001 in the LGE (+) group). In addition, this trend was maintained in the subgroups stratified by presence or absence of ischemia (0.3% vs. 6.7%, p = 0.007 in the ischemia (-) group; 3.9% vs. 17.1%, p = 0.001 in the ischemia (+) group). Adding CFR to the risk model (age + gender + left ventricular ejection fraction + %LGE + %ischemia) resulted in a significant increase of the C-index from 0.838 to 0.870 (p = 0.038) and an NRI of 0.201 (0.004-0.368, p = 0.012). CONCLUSION: PC cine CMR-derived CFR of the coronary sinus may be useful as a prognostic marker for DM patients, incremental to common clinical and CMR parameters. Due to the high prevalence of coronary microvascular dysfunction, the addition of CFR to conventional vasodilator stress CMR imaging may improve risk stratification for patients with DM.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Circulación Coronaria , Seno Coronario/diagnóstico por imagen , Diabetes Mellitus , Imagen por Resonancia Cinemagnética , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Enfermedades Cardiovasculares/mortalidad , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/terapia , Medios de Contraste/administración & dosificación , Seno Coronario/fisiopatología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
15.
J Postgrad Med ; 66(3): 159-161, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32567577

RESUMEN

Atrioventricular (AV)-nodal-reentrant-tachycardia is a rare association in a patient with persistent left-sided superior vena cava and dilated coronary sinus. There are a few inherent difficulties in ablation in this condition, viz., difficulty in localization of good site for ablation and difficulty in stabilization of the ablation catheter at the designated site, making it difficult to produce transmural lesions and increasing risk of producing AV block. We hereby present a case highlighting the difficulties and possible solutions for them.


Asunto(s)
Ablación por Catéter/métodos , Seno Coronario/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia/diagnóstico por imagen , Electrocardiografía , Femenino , Humanos , Persona de Mediana Edad , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Resultado del Tratamiento , Vena Cava Superior/anomalías
16.
Card Electrophysiol Clin ; 12(2): 209-217, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32451105

RESUMEN

When patients have symptomatic recurrent atrial tachyarrhythmias after 2 months following pulmonary vein antral isolation, a repeat ablation should be considered. Patients might present with isolated pulmonary veins posterior wall. In these patients, posterior wall isolation is extended, and non-pulmonary vein triggers are actively sought and ablated. Moreover, in those with non-paroxysmal atrial fibrillation or a known higher prevalence of non-pulmonary vein triggers, empirical isolation of the superior vena cava, coronary sinus, and/or left atrial appendage might be performed. In this review, we will focus on ablation of non-pulmonary vein triggers, summarizing our current approach for their mapping and ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter/efectos adversos , Venas Pulmonares , Apéndice Atrial/fisiopatología , Apéndice Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Seno Coronario/fisiopatología , Seno Coronario/cirugía , Humanos , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Recurrencia
17.
Card Electrophysiol Clin ; 12(2): 219-231, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32451106

RESUMEN

The optimal ablation strategy for non-paroxysmal atrial fibrillation remains controversial. Non-PV triggers have been shown to have a major arrhythmogenic role in these patients. Common sources of non-PV triggers are: posterior wall, left atrial appendage, superior vena cava, coronary sinus, vein of Marshall, interatrial septum, crista terminalis/Eustachian ridge, and mitral and tricuspid valve annuli. These sites are targeted empirically in selected cases or if significant ectopy is noted (with or without a drug challenge), to improve outcomes in patients with non-paroxysmal atrial fibrillation. This article focuses on summarizing the current evidence and the approach to mapping and ablation of these frequent non-PV trigger sites.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial , Ablación por Catéter , Seno Coronario/fisiopatología , Vena Cava Superior/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Humanos , Pericardio/fisiopatología , Pericardio/cirugía , Venas Pulmonares/fisiopatología
19.
Sci Rep ; 10(1): 6822, 2020 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-32321950

RESUMEN

Equine athletes have a pattern of exercise which is analogous to human athletes and the cardiovascular risks in both species are similar. Both species have a propensity for atrial fibrillation (AF), which is challenging to detect by ECG analysis when in paroxysmal form. We hypothesised that the proarrhythmic background present between fibrillation episodes in paroxysmal AF (PAF) might be detectable by complexity analysis of apparently normal sinus-rhythm ECGs. In this retrospective study ECG recordings were obtained during routine clinical work from 82 healthy horses and from 10 horses with a diagnosis of PAF. Artefact-free 60-second strips of normal sinus-rhythm ECGs were converted to binary strings using threshold crossing, beat detection and a novel feature detection parsing algorithm. Complexity of the resulting binary strings was calculated using Lempel-Ziv ('76 & '78) and Titchener complexity estimators. Dependence of Lempel-Ziv '76 and Titchener T-complexity on the heart rate in ECG strips obtained at low heart rates (25-60 bpm) and processed by the feature detection method was found to be significantly different in control animals and those diagnosed with PAF. This allows identification of horses with PAF from sinus-rhythm ECGs with high accuracy.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/veterinaria , Seno Coronario/diagnóstico por imagen , Seno Coronario/fisiopatología , Electrocardiografía/veterinaria , Frecuencia Cardíaca/fisiología , Caballos/fisiología , Animales , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA