2.
J Diabetes Sci Technol ; 18(5): 1052-1060, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39158988

RESUMEN

Nocturnal hypoglycemia is a common acute complication of people with diabetes on insulin therapy. In particular, the inability to control glucose levels during sleep, the impact of external factors such as exercise, or alcohol and the influence of hormones are the main causes. Nocturnal hypoglycemia has several negative somatic, psychological, and social effects for people with diabetes, which are summarized in this article. With the advent of continuous glucose monitoring (CGM), it has been shown that the number of nocturnal hypoglycemic events was significantly underestimated when traditional blood glucose monitoring was used. The CGM can reduce the number of nocturnal hypoglycemia episodes with the help of alarms, trend arrows, and evaluation routines. In combination with CGM with an insulin pump and an algorithm, automatic glucose adjustment (AID) systems have their particular strength in nocturnal glucose regulation and the prevention of nocturnal hypoglycemia. Nevertheless, the problem of nocturnal hypoglycemia has not yet been solved completely with the technologies currently available. The CGM systems that use predictive models to warn of hypoglycemia, improved AID systems that recognize hypoglycemia patterns even better, and the increasing integration of artificial intelligence methods are promising approaches in the future to significantly minimize the risk of a side effect of insulin therapy that is burdensome for people with diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Hipoglucemia , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/sangre , Hipoglucemia/diagnóstico , Glucemia/análisis , Glucemia/efectos de los fármacos , Sistemas de Infusión de Insulina/efectos adversos , Ritmo Circadiano/fisiología , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Algoritmos , Diabetes Mellitus/sangre , Diabetes Mellitus/tratamiento farmacológico , Monitoreo Continuo de Glucosa
4.
Diabetes Res Clin Pract ; 212: 111714, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38763169

RESUMEN

AIMS: To document the prevalence of skin problems associated with insulin pump use and identify contributing factors among children with type 1 diabetes mellitus in China. METHODS: In total, 461 children were recruited from an online community (i.e., a Wechat group) of pediatric patients with T1DM. A self-developed questionnaire was filled in by parents, collecting the information on social demographics, disease, and insulin pump therapy related characteristics and skin problems. We applied the Mann-Whitney U test, Chi square test and logistic regression analysis to identify the factors associated with skin problems. RESULTS: Of the 461 responders, 308 (66.8 %) children were reported to have skin problems. More specifically, 38.8 % had pigmentation changes, 22.3 % allergy/dermatitis, 20.2 % scaring, 11.5 % pain, 10.8 % infection, 10.6 % subcutaneous lipohypertrophy, and 6.1 % lipoatrophy. Logistic regression analysis showed that independent associated factors of skin problems were the caregiver's educational level as college or above, patient having skin allergies, and using the Brand 2 insulin pump (p values < 0.05). CONCLUSIONS: The present study documents the prevalence of skin problems and identifies associated factors, such as caregiver's education, patients skin allergies, and using a specific brand of pump. Health education should address these factors in addition to the traditionally emphasized factors.


Asunto(s)
Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Insulina , Enfermedades de la Piel , Humanos , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina/efectos adversos , Niño , Masculino , Femenino , Estudios Transversales , China/epidemiología , Prevalencia , Adolescente , Enfermedades de la Piel/epidemiología , Enfermedades de la Piel/inducido químicamente , Insulina/efectos adversos , Insulina/administración & dosificación , Insulina/uso terapéutico , Preescolar , Encuestas y Cuestionarios , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/administración & dosificación
7.
J Eur Acad Dermatol Venereol ; 38(7): 1329-1346, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38400603

RESUMEN

Use of medical devices (MDs), that is, glucose sensors and insulin pumps, in patients with Type 1 diabetes mellitus (T1D) has proven an enormous advantage for disease control. Adverse skin reactions from these MDs may however hamper compliance. The objective of this study was to systematically review and analyse studies assessing the prevalence and incidence of dermatitis, including allergic contact dermatitis (ACD) related to MDs used in patients with T1D and to compare referral routes and the clinical investigation routines between clinics being part of the European Environmental and Contact Dermatitis Research Group (EECDRG). A systematic search of PubMed, EMBASE, CINAHL and Cochrane databases of full-text studies reporting incidence and prevalence of dermatitis in persons with T1D using MDs was conducted until December 2021. The Newcastle-Ottawa Scale was used to assess study quality. The inventory performed at EECRDG clinics focused on referral routes, patient numbers and the diagnostic process. Among the 3145 screened abstracts, 39 studies fulfilled the inclusion criteria. Sixteen studies included data on children only, 14 studies were on adults and nine studies reported data on both children and adults. Participants were exposed to a broad range of devices. Skin reactions were rarely specified. It was found that both the diagnostic process and referral routes differ in different centres. Further data on the prevalence of skin reactions related to MDs in individuals with T1D is needed and particularly studies where the skin reactions are correctly diagnosed. A correct diagnosis is delayed or hampered by the fact that, at present, the actual substances within the MDs are not declared, are changed without notice and the commercially available test materials are not adequately updated. Within Europe, routines for referral should be made more standardized to improve the diagnostic procedure when investigating patients with possible ACD from MDs.


Asunto(s)
Dermatitis Alérgica por Contacto , Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/epidemiología , Prevalencia , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/diagnóstico , Niño , Adulto , Automonitorización de la Glucosa Sanguínea/instrumentación , Sistemas de Infusión de Insulina/efectos adversos , Encuestas y Cuestionarios , Incidencia
8.
Arch Endocrinol Metab ; 68: e230055, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38394157

RESUMEN

Objective: To evaluate glycemic control according to the number of daily basal rates (BRs) in type 1 diabetes patients using continuous subcutaneous insulin infusion (CSII). Subjects and methods: Cross-sectional study of patients treated with an open-loop CSII for at least 6 months and using a flash glucose monitoring system. Patients were divided into 2 groups: group 1 (G1) and group 2 (G2), with ≤4 and >4 BRs/24h, respectively. The groups were compared regarding HbA1c, time in range (TIR), time above range (TAR), time below range (TBR), glucose management indicator (GMI), glucose variability and data related to hypoglycemia. Regression models were performed. Results: The study included 99 patients (n = 55 in G1; n = 44 in G2). Median (Interquartile range) overall age was 30 (17) years, with 19.5 (48) and 51 (77) months of CSII use, respectively. The median number of different BRs was 3 (2) for G1 and 6 (2) for G2. There were no differences concerning age, sex, educational stage, weight, and insulin analog used. G2 had longer disease duration, longer CSII use, and higher total basal daily dose/kg. No significant differences regarding HbA1c, median glucose, GMI, TIR, TAR, and CV were found. G2 patients had more hypoglycemia, more asymptomatic hypoglycemia, and higher TBR. After adjusting for potential confounders, G1 maintained a lower risk of asymptomatic hypoglycemia. Conclusion: Programming open-loop CSII devices with more than 4 BRs does not improve metabolic control. Additionally, it seems to be a risk factor for hypoglycemia and was an independent predictor for asymptomatic hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Adulto , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Estudios Transversales , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Sistemas de Infusión de Insulina/efectos adversos
9.
Diabetes Technol Ther ; 26(S3): 97-101, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38377320

RESUMEN

The use of automated insulin delivery (AID) has led to a decrease in the burden of diabetes, allowing for better sleep, decreased anxiety about hypoglycemia, and automatic corrections doses, and meal recognition algorithms have provided "forgiveness" for imprecise carbohydrate (CHO) entries and missed or late meal boluses. We provide a case report and review of the current literature assessing the effect of AID on the burden of meal bolus. The case also demonstrates how sensor and pump data provide insight into insulin bolus behavior, and access to integrated cloud-based data has allowed for virtual patient visits. Glucose sensor metrics provides time in range and time below range, and the sensor-derived glucose management indicator provides an assessment of the long-term risk of complications when a laboratory glycated hemoglobin is not available.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Hipoglucemia/prevención & control , Hipoglucemia/etiología , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Insulina Regular Humana/uso terapéutico
10.
Endocrine ; 84(1): 128-135, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38197988

RESUMEN

AIMS: Both hyperglycaemia and large glycaemic variability are associated with worse outcomes in patients with Type 2 diabetes mellitus (T2DM), possibly causing sympatho-vagal imbalance and endothelial dysfunction. Continuous subcutaneous insulin injection (CSII) improves glycemic control compared to multiple daily insulin injections (MDI). We aimed to assess whether CSII may improve cardiac autonomic and vascular dilation function compared to MDI. METHODS: We enrolled T2DM patients without cardiovascular disease with poor glycaemic control, despite optimized MDI therapy. Patients were randomized to continue MDI (with multiple daily peripheral glucose measurements) or CSII; insulin dose was adjusted to achieve optimal target ranges of blood glucose levels. Patients were studied at baseline and after 6 months by: 1) flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of the brachial artery; 2) heart rate variability (HRV) by 24-hour ECG Holter monitoring (HM). 7-day continuous glucose monitoring (CGM) was performed in 9 and 8 patients of Group 1 and 2, respectively. RESULTS: Overall, 21 patients were enrolled, 12 randomized to CSII (Group 1) and 9 to MDI (Group 2). The daily dose of insulin and Hb1AC did not differ significantly between the 2 groups, both at baseline and at follow-up. Glucose variability showed some significant improvement at follow-up in the whole population, but no differences were observed between the 2 groups. Both FMD and NMD, as well as HRV parameters, showed no significant differences between the 2 groups at 6-month follow-up. CONCLUSIONS: In this randomized small study we show that, in T2DM patients, CSII achieves a similar medium-term glycemic control compared to MDI, without any adverse effect on the cardiovascular system.


Asunto(s)
Enfermedades Autoinmunes , Sistema Cardiovascular , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hiperglucemia , Humanos , Insulina , Hipoglucemiantes/efectos adversos , Automonitorización de la Glucosa Sanguínea , Glucemia , Hiperglucemia/tratamiento farmacológico , Inyecciones Subcutáneas , Sistemas de Infusión de Insulina/efectos adversos
11.
J Diabetes Complications ; 38(2): 108689, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38244326

RESUMEN

AIMS: Automated insulin delivery systems improve blood glucose control in patients with type 1 diabetes (T1D). However, optimizing their performance requires patient's proper compliance to meal insulin bolus administration. We explored real-life prevalence of delayed prandial boluses (DBs) in adults with T1D on advanced technologies, and their association with glycemic control and fear of hypoglycemia (FH). METHODS: In the last two-week web-based reports of 152 adults with T1D on Hybrid Closed Loop Systems (HCLS) or Sensor Augmented Pump (SAP), DBs were identified when a steep increase in blood glucose occurred at CGM before the prandial bolus, and CGM metrics were evaluated. All participants completed an online questionnaire on FH. RESULTS: Mean DBs over two weeks were 10.2 ± 4.7 (M ± SD, range 1-23) and more frequent in women than men (11.0 ± 4.6 vs. 9.4 ± 4.7, p = 0.036). Participants with more DBs (>12) showed significantly lower Time-In-Range (62.4 ± 13.8 vs. 76.6 ± 9.0 %) than those with less DBs (<7.7), along with higher Time-Above-Range, GMI, and Coefficient-of-Variation (ANOVA, p < 0.001 for all). Participants with higher FH score showed more DBs (11.6 ± 5.0) than those in lower tertiles (9.57 ± 4.59 and 9.47 ± 4.45, ANOVA p = 0.045). CONCLUSIONS: In patients on advanced technologies, delayed boluses are extremely common, and associate with significantly worse glycemic control. Utmost attention is needed to bolus timing, mainly tackling fear of hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Masculino , Adulto , Humanos , Femenino , Insulina/efectos adversos , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/efectos adversos , Control Glucémico , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Glucemia , Insulina Regular Humana/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Miedo
12.
Diabetes Technol Ther ; 26(1): 24-32, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37782904

RESUMEN

Objective: Severe hypoglycemia (SH) and diabetic ketoacidosis (DKA) remain significant risks with intensive insulin therapy. While these adverse event (AE) rates are generally very low in advanced hybrid closed-loop (AHCL) clinical studies, prospectively collected real-world AE rates are lacking. Research Design and Methods: The Control-IQ Observational (CLIO) study was a single-arm, prospective, longitudinal, postmarket surveillance study of individuals with type 1 diabetes (T1D) age 6 years and older who began the use of t:slim X2 insulin pump with Control-IQ technology in the real-world outpatient setting. AEs were reported monthly over 12 months and were compared to historical data from the T1D Exchange. Patient-reported outcomes were assessed quarterly. All study visits were virtual. Results: Three thousand one hundred fifty-seven participants enrolled from August 2020 through March 2022. Two thousand nine hundred ninety-eight participants completed through 12 months. SH rates were significantly lower than historic rates for children (9.31 vs. 19.31 events/100 patient years, d = 0.29, P < 0.01) and adults (9.77 vs. 29.49 events/100 patient years, d = 0.53, P < 0.01). DKA rates were also significantly lower in both groups. Lower observed rates of AEs occurred independent of baseline hemoglobin A1c or prior insulin delivery method. Time in range 70-180 mg/dL was 70.1% (61.0-78.8) for adults, 61.2% (52.4-70.5) for age 6-13, 60.9% (50.1-71.8) for age 14-17, and 67.3% (57.4-76.9) overall. Reduction in diabetes burden was consistently reported. Conclusions: SH and DKA rates were lower for users of t:slim X2 with Control-IQ technology compared to historical data for both adults and children. Real-world use of this AHCL system proved safe and effective in this virtual study design. The study was registered at clinicaltrials.gov (NCT04503174).


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Niño , Adulto , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicaciones , Estudios Prospectivos , Cetoacidosis Diabética/inducido químicamente , Cetoacidosis Diabética/epidemiología , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Insulina/efectos adversos , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemiantes/efectos adversos , Glucemia
13.
J Diabetes Sci Technol ; 18(2): 318-323, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37966051

RESUMEN

BACKGROUND: With automated insulin delivery (AID) systems becoming widely adopted in the management of type 1 diabetes, we have seen an increase in occurrences of rebound hypoglycemia or generated hypoglycemia induced by the controller's response to rapid glucose rises following rescue carbohydrates. Furthermore, as AID systems aim to enable complete automation of prandial control, algorithms are designed to react even more strongly to glycemic rises. This work introduces a rebound hypoglycemia prevention layer (HypoSafe) that can be easily integrated into any AID system. METHODS: HypoSafe constrains the maximum permissible insulin delivery dose based on the minimum glucose reading from the previous hour and the current glucose level. To demonstrate its efficacy, we integrated HypoSafe into the latest University of Virginia (UVA) AID system and simulated two scenarios using the 100-adult cohort of the UVA/Padova T1D simulator: a nominal case including three unannounced meals, and another case where hypoglycemia was purposely induced by an overestimated manual bolus. RESULTS: In both simulation scenarios, rebound hypoglycemia events were reduced with HypoSafe (nominal: from 39 to 0, hypo-induced: from 55 to 7) by attenuating the commanded basal (nominal: 0.27U vs. 0.04U, hypo-induced: 0.27U vs. 0.03U) and bolus (nominal: 1.02U vs. 0.05U, hypo-induced: 0.43U vs. 0.02U) within the 30-minute interval after treating a hypoglycemia event. No clinically significant changes resulted for time in the range of 70 to 180 mg/dL or above 180 mg/dL. CONCLUSION: HypoSafe was shown to be effective in reducing rebound hypoglycemia events without affecting achieved time in range when combined with an advanced AID system.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Páncreas Artificial , Adulto , Humanos , Hipoglucemiantes/efectos adversos , Páncreas Artificial/efectos adversos , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemia/inducido químicamente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/efectos adversos , Glucosa/efectos adversos
14.
Diabetes Obes Metab ; 26(3): 937-949, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38151748

RESUMEN

AIM: To report on the effectiveness and safety of the MiniMed 780G automated insulin delivery system in real-world users during the month of Ramadan. MATERIALS AND METHODS: CareLink Personal data were extracted from MiniMed 780G system users from the Gulf region. Users were included if they had ≥10 days of sensor glucose data during the month of Ramadan 2022 as well as in the month before and after. For the main analysis, continuous glucose monitoring endpoints were aggregated per month and were reported by time of day (daytime: 05.31-18.00 h, and night-time). Additional analyses were performed to study the pace at which the algorithm adapts. RESULTS: Glycaemic control was well kept in the 449 included users (mean sensor glucose = 152.6 ± 18.7 mg/dl, glucose management indicator = 7.0 ± 0.4%, time in range = 70.7 ± 11.0%, time below 70 mg/dl = 2.3 ± 2.3%). Albeit some metrics differed from the month before (p < .0001 for all), absolute differences were very small and considered clinically irrelevant. During Ramadan, there was no increased risk of hypoglycaemia during daytime (time below 70 mg/dl = 2.3 ± 2.4%), time in range was highest during daytime (80.0 ± 10.7%, night: 60.4 ± 15.3%), while time above 180 mg/dl was highest during night-time (37.3 ± 16.3%, day: 17.7 ± 10.7%). The algorithm adapted immediately upon lifestyle change. CONCLUSION: The MiniMed 780G automated insulin delivery system is effective, safe and fast in adapting to the substantial changes that occur in the lifestyle of people with type 1 diabetes during Ramadan.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Insulina/efectos adversos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemiantes/efectos adversos
16.
Diabetes Care ; 47(3): 384-392, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38128075

RESUMEN

OBJECTIVE: To compare the risk of fetal overgrowth and preterm delivery in pregnant women with type 1 diabetes (T1D) treated with insulin pumps versus multiple daily injections (MDI) and examine whether possible differences were mediated through improved glycemic control or gestational weight gain during pregnancy. RESEARCH DESIGN AND METHODS: The risk of pregnancy and perinatal outcomes were evaluated in a cohort of 2,003 pregnant women with T1D enrolled from 17 countries in a real-world setting during 2013-2018. RESULTS: In total, 723 women were treated with pumps and 1,280 with MDI. At inclusion (median gestational weeks 8.6 [interquartile range 7-10]), pump users had lower mean HbA1c (mean ± SD 50.6 ± 9.8 mmol/mol [6.8 ± 0.9%] vs. 53.6 ± 13.8 mmol/mol [7.1 ± 1.3%], P < 0.001), longer diabetes duration (18.4 ± 7.8 vs. 14.4 ± 8.2 years, P < 0.001), and higher prevalence of retinopathy (35.3% vs. 24.4%, P < 0.001). Proportions of large for gestational age (LGA) offspring and preterm delivery were 59.0% vs. 52.2% (adjusted odds ratio [OR] 1.36 [95% CI 1.09; 1.70], P = 0.007) and 39.6% vs. 32.1% (adjusted OR 1.46 (95% CI 1.17; 1.82), P < 0.001), respectively. The results did not change after adjustment for HbA1c or gestational weight gain. CONCLUSIONS: Insulin pump treatment in pregnant women with T1D, prior to the widespread use of continuous glucose monitoring or automated insulin delivery, was associated with a higher risk of LGA offspring and preterm delivery compared with MDI in crude and adjusted analyses. This association did not appear to be mediated by differences in glycemic control as represented by HbA1c or by gestational weight gain.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Gestacional , Ganancia de Peso Gestacional , Nacimiento Prematuro , Recién Nacido , Femenino , Embarazo , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Macrosomía Fetal/epidemiología , Glucemia , Insulina/efectos adversos , Aumento de Peso , Inyecciones Subcutáneas , Hipoglucemiantes/efectos adversos , Sistemas de Infusión de Insulina/efectos adversos
17.
Diabetes Technol Ther ; 25(12): 893-901, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37956265

RESUMEN

Background: Evaluate the impact of the MiniMed™ 780G advanced hybrid closed-loop (AHCL) system on the glucose profile of pregnant women with type 1 diabetes (T1D) and maternal-neonatal complications. Methods: From April 2021 to September 2022, pregnant women with T1D treated with the AHCL system were included in an observational multicenter retrospective study. Continuous glucose monitoring parameters were analyzed monthly during pregnancy as well as maternal-neonatal complications. Results: Thirteen pregnant women, including a twin pregnancy (age: 33 ± 3 years, hemoglobin A1c [HbA1c]: 7.3% ± 0.7%, insulin doses: 0.72 ± 0.21 U/kg/day) were analyzed. At delivery, gestational age was 37 ± 2 weeks. During first 2 weeks of pregnancy, time in range (TIR, 63-140 mg/dL) was 46% (34-55) and increased to 54% (51-59) (P < 0.01), 64% (48-68) (P < 0.01), and 66% (60-70) (P < 0.001) during the first, second, and third trimester, respectively. During the night, TIR (63-140 mg/dL) was >70% throughout pregnancy. Time below the range <63 mg/dL increased from 0.5% (0-2) to 1.3% (0.7-2.2), 2% (1.2-3.5) (P < 0.05), and 1.3% (1.31-3) (P < 0.05) during the first, second, and third trimester, respectively. At delivery, insulin doses increased to 0.89 ± 0.35 IU/kg/day (P < 0.01), and HbA1c decreased to 6.4% ± 0.6% (P = 0.005). The reported carbohydrate amount increased from 167 ± 363 g/d during early pregnancy to 243 ± 106 g/d (P < 0.01) at delivery. The birthweight was 3134 ± 711 g, with 5/14 macrosomia and 2/14 neonatal hypoglycemia. Moreover, 5/13 patients had a preeclampsia and 9/13 a cesarean section, including three cases of scarred uterus. The Clinical Trial Registration number is: CE-2022-55. Conclusion: The AHCL system provided good glucose control during pregnancy and recommendation targets were reached during the nocturnal period only. The maternal and neonatal complications remained high.


Asunto(s)
Diabetes Mellitus Tipo 1 , Embarazo en Diabéticas , Adulto , Femenino , Humanos , Recién Nacido , Embarazo , Glucemia , Automonitorización de la Glucosa Sanguínea , Cesárea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Hemoglobina Glucada , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Embarazo en Diabéticas/tratamiento farmacológico , Mujeres Embarazadas , Estudios Retrospectivos
18.
N Engl J Med ; 389(17): 1566-1578, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37796241

RESUMEN

BACKGROUND: Hybrid closed-loop insulin therapy has shown promise for management of type 1 diabetes during pregnancy; however, its efficacy is unclear. METHODS: In this multicenter, controlled trial, we randomly assigned pregnant women with type 1 diabetes and a glycated hemoglobin level of at least 6.5% at nine sites in the United Kingdom to receive standard insulin therapy or hybrid closed-loop therapy, with both groups using continuous glucose monitoring. The primary outcome was the percentage of time in the pregnancy-specific target glucose range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]) as measured by continuous glucose monitoring from 16 weeks' gestation until delivery. Analyses were performed according to the intention-to-treat principle. Key secondary outcomes were the percentage of time spent in a hyperglycemic state (glucose level >140 mg per deciliter), overnight time in the target range, the glycated hemoglobin level, and safety events. RESULTS: A total of 124 participants with a mean (±SD) age of 31.1±5.3 years and a mean baseline glycated hemoglobin level of 7.7±1.2% underwent randomization. The mean percentage of time that the maternal glucose level was in the target range was 68.2±10.5% in the closed-loop group and 55.6±12.5% in the standard-care group (mean adjusted difference, 10.5 percentage points; 95% confidence interval [CI], 7.0 to 14.0; P<0.001). Results for the secondary outcomes were consistent with those of the primary outcome; participants in the closed-loop group spent less time in a hyperglycemic state than those in the standard-care group (difference, -10.2 percentage points; 95% CI, -13.8 to -6.6); had more overnight time in the target range (difference, 12.3 percentage points; 95% CI, 8.3 to 16.2), and had lower glycated hemoglobin levels (difference, -0.31 percentage points; 95% CI, -0.50 to -0.12). Little time was spent in a hypoglycemic state. No unanticipated safety problems associated with the use of closed-loop therapy during pregnancy occurred (6 instances of severe hypoglycemia, vs. 5 in the standard-care group; 1 instance of diabetic ketoacidosis in each group; and 12 device-related adverse events in the closed-loop group, 7 related to closed-loop therapy). CONCLUSIONS: Hybrid closed-loop therapy significantly improved maternal glycemic control during pregnancy complicated by type 1 diabetes. (Funded by the Efficacy and Mechanism Evaluation Program; AiDAPT ISRCTN Registry number, ISRCTN56898625.).


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Embarazo en Diabéticas , Adulto , Femenino , Humanos , Embarazo , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Embarazo en Diabéticas/sangre , Embarazo en Diabéticas/tratamiento farmacológico , Resultado del Tratamiento
19.
Diabetes Res Clin Pract ; 204: 110922, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37769906

RESUMEN

AIMS: To evaluate the incidence of the skin reactions secondary to continuous subcutaneous insulin infusion (CSII) or continuous glucose monitoring (CGM), sensors and the characteristics of affected children with type 1 diabetes. METHODS: An observational, retrospective, single-centre study included 198 children with type 1 diabetes, (46% girls, mean age 11.75 years). A standardised questionnaire was completed with the patient during current care to evaluate the skin reactions (mean and percentage), the type of reaction, their impact and the treatment) and the characteristics of affected children with univariate and multivariate analysis. RESULTS: Sixty-seven children (33.8%) reported active skin reactions: 45 children with CSII (30.4%) and 46 with CGM (23.5%). Children with skin reactions were younger (mean age 10.6 yo versus 12.34 yo, p < 0.05), with a younger age at the diagnosis of diabetes (5.59 yo versus 7.08 yo, p < 0.05). Atopy was more frequent in the group with skin reactions (76.1% versus 54.1% p < 0.05). On multivariate analysis, only the personal history of atopy was associated with skin reactions: OR 2.56 [1.16-5.97] (p < 0.05). CONCLUSION: This study confirms the high incidence of skin reactions to adhesive devices used in the treatment of type 1 diabetes in children.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Femenino , Humanos , Niño , Masculino , Insulina/efectos adversos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Hipoglucemiantes/efectos adversos , Automonitorización de la Glucosa Sanguínea , Incidencia , Estudios Retrospectivos , Glucemia , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos
20.
J Diabetes Sci Technol ; 17(6): 1433-1439, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37449762

RESUMEN

BACKGROUND: DBLG1 (Diabeloop Generation 1) stands as one of the five commercially available closed-loop solution worldwide for patients with type 1 diabetes as of 2023. Our aim was to provide an overview of all data obtained with this system regarding outcomes and populations, with an emphasis on interoperability. METHODS: This report includes all available sources of data (three randomized control trials and five surveys on real-life data). Collection ran from March 3, 2017 to April 30, 2022. RESULTS: We gathered data from 6859 adult patients treated with closed-loop from three to 12 months. Overall, all sources of data showed that time in range (TIR) 70 to 180 mg/dL, starting from 47.4% to 56.6%, improved from 12.2 to 17.3 percentage points. Time in hypoglycemia was reduced by 48% in average (range: 26%-70%) and reached a level of 1.3% in the largest and most recent cohort. In patients with excessive time in hypoglycemia at baseline (≥5%), closed-loop allowed a reduction in time below range (TBR) by 59%. The comparison of days with declared physical activity versus days without physical activity did not show differences in TBR. The improvement in TIR observed with three different pump systems (Vicentra Kaleido, n = 117; Sooil Dana-I, n = 84; and Roche Insight, n = 6684) ranged from 15.4 to 17.3 percentage points. DISCUSSION: These data obtained in different European countries were consistent throughout all reports, showing that this closed-loop system is efficient (high improvement in TIR), safe (remarkably low level of TBR), and interoperable (three pump settings so far).


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico , Glucemia , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemia/inducido químicamente , Insulina Regular Humana/uso terapéutico