Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.918
Filtrar
1.
Mikrochim Acta ; 191(7): 437, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951284

RESUMEN

A stable DNA signal amplification sensor was developed on account of rolling circle amplification (RCA). This sensor includes target DNA-controlled rolling circle amplification technology and locking probe DNA replacement technology, which can be used to detect DNA fragments with genetic information, thus constructing a biosensor for universal detection of DNA. This study takes the homologous DNA of human immunodeficiency virus (HIV) and let-7a as examples to describe this biosensor. The padlock probe is first cyclized by T4 DNA ligase in response to the target's reaction with it. Then, rolling cycle amplification is initiated by Phi29 DNA polymerase, resulting in the formation of a lengthy chain with several triggers. These triggers can open the locked probe LP1 with the fluorescence signal turned off, so that it can continue to react with H2 to form a stable H1-H2 double strand. This regulates the distance between B-DNA modified by the quenching group and H1 modified by fluorescent group, and the fluorescence signal is recovered.


Asunto(s)
Técnicas Biosensibles , Sondas de ADN , Técnicas de Amplificación de Ácido Nucleico , Técnicas Biosensibles/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Humanos , Sondas de ADN/química , Sondas de ADN/genética , Colorantes Fluorescentes/química , ADN Viral/análisis , ADN Viral/genética , ADN/química , ADN/genética , Espectrometría de Fluorescencia/métodos , Fluorescencia , ADN Polimerasa Dirigida por ADN/metabolismo , ADN Polimerasa Dirigida por ADN/química , Límite de Detección , VIH/genética
2.
Anal Chim Acta ; 1316: 342873, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969432

RESUMEN

BACKGROUND: DNA walker-based strategies have gained significant attention in nucleic acid analysis. However, they face challenges related to balancing design complexity, sequence dependence, and amplification efficiency. Furthermore, most existing DNA walkers rely on walking and lock probes, requiring optimization of various parameters like DNA probe sequence, walking-to-lock probe ratio, lock probe length, etc. to achieve optimal performance. This optimization process is time-consuming and adds complexity to experiments. To enhance the performance and reliability of DNA walker nanomachines, there is a need for a simpler, highly sensitive, and selective alternative strategy. RESULTS: A sensitive and rapid miRNA analysis strategy named hairpin-shaped DNA aligner and nicking endonuclease-fueled DNA walker (HDA-NE DNA walker) was developed. The HDA-NE DNA walker was constructed by modifying hairpin-shaped DNA aligner (HDA) probe and substrate report (SR) probe on the surface of AuNPs. Under normal conditions, HDA and SR remained stable. However, in the presence of miR-373, HDA underwent a conformational transition to an activated structure to continuously cleave the SR probe on the AuNPs with the assistance of Nt.AlwI nicking endonuclease, resulting in sensitive miRNA detection with a detection limit as low as 0.23 pM. Additionally, the proposed HDA-NE DNA walker exhibited high selectivity in distinguishing miRNAs with single base differences and can effectively analyze miR-373 levels in both normal and breast cancer patient serums. SIGNIFICANCE: The proposed HDA-NE DNA walker system was activated by a conformational change of HDA probe only in the presence of the target miRNA, eliminating the need for a lock probe and without sequence dependence for SR probe. This strategy demonstrated a rapid reaction rate of only 30 min, minimal background noise, and a high signal-to-noise ratio (S/B) compared to capture/lock-based DNA walker. The method is expected to become a powerful tool and play an important role in disease diagnosis and precision therapy.


Asunto(s)
ADN , MicroARNs , MicroARNs/sangre , MicroARNs/análisis , Humanos , ADN/química , Límite de Detección , Técnicas Biosensibles/métodos , Oro/química , Nanopartículas del Metal/química , Sondas de ADN/química , Sondas de ADN/genética , Endonucleasas/metabolismo , Endonucleasas/química , Secuencias Invertidas Repetidas
3.
Anal Methods ; 16(29): 5032-5037, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-38980034

RESUMEN

In this work, a sensitive ratiometric electrochemical biosensor for microRNA-155 (miRNA-155) detection is reported based on a hybridization chain reaction amplifying the electrochemical signal. The biosensor was fabricated using Au NPs as a modified material to assemble capture DNA labeled with ferrocene (Fc) molecules, and a DNA probe labeled with methylene blue (MB) was employed for the signal probe. In the presence of target miRNA-155, it can be dual hybridized with capture and signal probe, especially with signal probe to continuously produce long concatemers containing lots of MB molecules. The electrochemical signal of Fc was used for the internal signal, and the signal from MB was used as an indicator signal. As the concentration of miRNA-155 was altered, the internal reference signal of Fc remained constant, and only the indicator signal changed in a sensitive way. The change in the ratio (IMB/IFc) between the indicator signal of MB and internal reference signal of Fc can be used to monitor the concentration of miRNA-155. Under optimal conditions, the prepared ratiometric biosensor could detect miRNA-155 within a wide linear range from 100 fM to 100 nM with low detection limit of 33 fM (at S/N = 3). Moreover, the biosensor was evaluated with human serum samples, and satisfactory recoveries were obtained, indicating that the ratiometric biosensor can be applied to clinical sample analysis.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Oro , Límite de Detección , MicroARNs , Hibridación de Ácido Nucleico , MicroARNs/sangre , MicroARNs/análisis , Técnicas Biosensibles/métodos , Humanos , Técnicas Electroquímicas/métodos , Oro/química , Nanopartículas del Metal/química , Compuestos Ferrosos/química , Metalocenos/química , Sondas de ADN/química , Sondas de ADN/genética , Azul de Metileno/química
4.
Anal Chim Acta ; 1317: 342872, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39030016

RESUMEN

Fluorescently labeled DNA oligonucleotides and gold nanospheres have been frequently utilized in biosensors, providing efficient nucleic acid detection. Nevertheless, the restricted loading capacity of gold nanospheres undermines overall sensitivity. In this study, we employed four-atom-thick ultrathin gold nanosheets (AuNSs), utilizing a "pre-mix model" for rapid target nucleic acid detection. In this approach, fluorescently labeled DNA probes were pre-incubated with the target nucleic acid, followed by the addition of AuNSs for probe adsorption and fluorescence quenching. With the developed method, we efficiently and rapidly detected the SARS-CoV-2 N gene sequence within 30 min, involving a brief 15-min target pre-incubation and a subsequent 15-min adsorption of free probes and fluorescence quenching by AuNSs. This method exhibited heightened sensitivity compared to gold nanospheres, boasting a limit of detection (LOD) of 0.808 nM. Furthermore, exceptional recovery was achieved in simulated biological samples. The study introduces an effective strategy for nucleic acid sensing characterized by rapidity, heightened sensitivity, ease of operation, and robustness. These findings encourage further development of rapid biomarker sensing methods employing 2D nanomaterials.


Asunto(s)
Técnicas Biosensibles , Colorantes Fluorescentes , Oro , Límite de Detección , Nanopartículas del Metal , SARS-CoV-2 , Oro/química , SARS-CoV-2/aislamiento & purificación , Colorantes Fluorescentes/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Humanos , Espectrometría de Fluorescencia , Nanoestructuras/química , Sondas de ADN/química , COVID-19/diagnóstico , COVID-19/virología
5.
Mikrochim Acta ; 191(8): 462, 2024 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-38990374

RESUMEN

A CHA-based fluorescent DNA tetrahedral probe (FDTp) has been designed to detect the microRNAs miR-21 and miR-155 sensitively and specifically in living cells. The design consisted of functional elements (H1, H2, and Protector) connected to a DNA tetrahedron modified with two pairs of fluorophores and quenching groups. In the presence of miR-21, the chain displacement effect was triggered and Cy3 fluorescence was emitted. In the presence of miR-155, the signal of the catalytic hairpin assembly (CHA) between H1 and H2 on FDTp was amplified, making the fluorescence of FAM sensitive to miR-155. Using this method, the detection limit for miR-155 was 5 pM. The FDTp successfully imaged miR-21 and miR-155 in living cells and distinguished a variety of cell lines based on their expression levels of miR-21 and miR-155. The detection and imaging of dual targets in this design ensured the accuracy of tumor diagnosis and provided a new method for early tumor diagnosis.


Asunto(s)
Colorantes Fluorescentes , MicroARNs , MicroARNs/análisis , Humanos , Colorantes Fluorescentes/química , Límite de Detección , Sondas de ADN/química , Imagen Óptica , Espectrometría de Fluorescencia , Secuencias Invertidas Repetidas , Células HeLa , Catálisis , ADN/química
6.
J Mater Chem B ; 12(30): 7311-7323, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38954469

RESUMEN

Foodborne pathogens including Salmonella typhimurium (S. typhimurium) are responsible for over 600 million global incidences of illness annually, posing a significant threat to public health. Inductively coupled plasma mass spectrometry (ICP-MS), coupled with element labeling strategies, has emerged as a promising platform for multivariate and accurate pathogen detection. However, achieving high specificity and sensitivity remains a critical challenge. Herein, we synthesize clustered magnetic nanoparticles (MNPs) and popcorn-shaped gold nanoparticles (AuNPs) to conjugate capture and report DNA probes for S. typhimurium, respectively. These engineered nanoparticles facilitate the identification of S. typhimurium DNA through a sandwich hybridization technique. ICP-MS quantification of Au within the sandwich-structure complexes allows for precise S. typhimurium detection. The unique morphology of the AuNPs and MNPs increases the available sites for probe attachment, enhancing the efficiency of S. typhimurium DNA capture, broadening the detection range to 101-1010 copies mL-1, and achieving a low detection limit of 1 copy mL-1, and the overall assay time is 70 min. The high specificity of this method is verified by anti-interference assays against ten other pathogens. The recovery was 96.8-102.8% for detecting S. typhimurium DNA in biological samples. As these specially designed nanoparticles may facilitate the attachment of various proteins and nucleic acid probes, they may become an effective platform for detecting multiple pathogens.


Asunto(s)
Oro , Nanopartículas de Magnetita , Hibridación de Ácido Nucleico , Salmonella typhimurium , Salmonella typhimurium/aislamiento & purificación , Oro/química , Nanopartículas de Magnetita/química , Espectrometría de Masas , ADN Bacteriano/análisis , Nanopartículas del Metal/química , Sondas de ADN/química , Tamaño de la Partícula
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 320: 124643, 2024 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-38901233

RESUMEN

Herein, two simple fluorescent signal-on sensing strategies for detecting lead ions (Pb2+) were established based on structure-switching aptamer probes and exonuclease-assisted signal amplification strategies. Two hairpin-structure fluorescent probes with blunt-ended stem arms were designed by extending the base sequence of Pb2+ aptamer (PS2.M) and labelling the probes with FAM (in probe 1) and 2-aminopurine (2-AP) (in probe 2), respectively. In method 1, graphene oxide (GO) was added to adsorb probe 1 and quench the fluorescence emission of FAM to achieve low fluorescent background. In method 2, fluorescent 2-AP molecule inserted into the double-stranded DNA of probe 2 was quenched as a result of base stacking interactions, leading to a simplified, quencher-free approach. The addition of Pb2+ can induce the probes to transform into G-quadruplex structures, exposing single DNA strands at the 3' end (the extended sequences). This exposure enables the activation of exonuclease I (Exo I) on the probes, leading to the cleavage effect and subsequent release of free bases and fluorophores, thereby resulting in amplified fluorescence signals. The two proposed methods exhibit good specificity and sensitivity, with detection limits of 0.327 nM and 0.049 nM Pb2+ for method 1 and method 2, respectively, and have been successfully applied to detect Pb2+ in river water and fish samples. Both detection methods employ the structure-switching aptamer probes and can be completed in two or three steps without the need for complex analytical instruments. Therefore, they have a broad prospect in the sensitive and simple detection of lead ion contamination in food and environmental samples.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Exodesoxirribonucleasas , Colorantes Fluorescentes , Plomo , Límite de Detección , Espectrometría de Fluorescencia , Plomo/análisis , Aptámeros de Nucleótidos/química , Exodesoxirribonucleasas/metabolismo , Exodesoxirribonucleasas/química , Colorantes Fluorescentes/química , Espectrometría de Fluorescencia/métodos , Técnicas Biosensibles/métodos , Sondas de ADN/química , Contaminantes Químicos del Agua/análisis , Animales , Iones/análisis , Grafito/química
8.
Talanta ; 277: 126333, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38850801

RESUMEN

MicroRNA (miRNA) represents a class of important potential biomarkers, and their intracellular imaging is extremely useful for fundamental research and early diagnosis of human cancers. Hybridization chain reaction (HCR) has been shown to be effective in detecting miRNA in living cells. However, its practical applications are still hampered by inefficient reaction kinetics and poor biological stability under complex intracellular conditions. To address these issues, we report a palindrome-mediated multiple hybridization chain reaction (P-HCR) system to better visualize intracellular miRNAs. In the presence of the target miRNA, a layered nanosheet DNA architecture (LSDA) can be assembled in situ via the palindrome-mediated multiple HCR process. We demonstrate that the biological stability of this reaction system could be significantly improved by designing the probes to dumbbell-shaped structures and the distance of hairpins was effectively decreased due to palindrome-chained effect. Consequently, miRNA can be quantitatively identified even at extremely low concentrations of 4.7 pM. The P-HCR system can effectively differentiate the expression levels of miRNA in different tumor cells and normal cells, as demonstrated in live cell tests and the results were in agreement with the PCR, which is considered the gold standard. The new (P-HCR) system has the potential to revolutionize miRNA imaging in living cells.


Asunto(s)
ADN , MicroARNs , Nanoestructuras , Hibridación de Ácido Nucleico , MicroARNs/análisis , Humanos , Nanoestructuras/química , ADN/química , Sondas de ADN/química , Secuencias Invertidas Repetidas
9.
Talanta ; 277: 126348, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38852348

RESUMEN

Clustered regularly interspaced short palindromic repeat (CRISPR) system has been explored as an efficient tool for nucleic acid diagnostics. However, it normally needs instrumentation or produces turn-off signals. Herein, a bulged Y-shape DNA (Y-DNA) nanoassembly was designed and synthesized as a novel turn-on probe. A CRISPR/Cas12a and Y-DNA probe mediated colorimetric assay (named as CYMCOA) strategy was developed for visual detection of pathogen DNA. Upon activating Cas12a with pathogen DNA, the Y-DNA bulge is catalytically trans-cleaved, releasing the G-quadruplex sequence embedded in the Y-DNA nanoassembly as a peroxidase-like DNAzyme. Visible signals with chromogen substrates are thus produced. The CYMCOA strategy was combined with recombinase polymerase amplification (RPA), an isothermal amplification technique, in detecting Helicobacter pylori (Hp) bacteria and SARS-CoV-2 N plasmids as two model pathogens. The bioassay has very excellent detection sensitivity and specificity, owing to the triple cascade amplification reactions and the very low mismatch tolerance. The lower limit of detection values were 0.16 cfu⋅mL-1, 1.5 copies⋅µL-1, and 0.17 copies⋅µL-1 for Hp bacteria, Hp plasmids, and SARS-CoV-2 N plasmids respectively. The detection is fast and accurate. The colorimetric bioassay strategy provides to be a simple, accurate, fast and instrumentation-free platform for nucleic acids detections in various settings, including crude and emergent situations.


Asunto(s)
Sistemas CRISPR-Cas , Colorimetría , Técnicas de Amplificación de Ácido Nucleico , SARS-CoV-2 , Colorimetría/métodos , Sistemas CRISPR-Cas/genética , Técnicas de Amplificación de Ácido Nucleico/métodos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Helicobacter pylori/genética , Helicobacter pylori/aislamiento & purificación , ADN Bacteriano/genética , ADN Bacteriano/análisis , ADN Viral/genética , ADN Viral/análisis , Límite de Detección , Humanos , Técnicas Biosensibles/métodos , Nanoestructuras/química , Sondas de ADN/química , Sondas de ADN/genética , Proteínas Asociadas a CRISPR/genética , Proteínas Bacterianas/genética , Endodesoxirribonucleasas
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 321: 124682, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38936209

RESUMEN

The accurate and sensitive detection of metallothionein (MT) is of great significance in the fields of biomedical, toxicological and environmental sciences. In this work, based on the high affinity interaction between MT and the heavy metal ions of Hg2+ and the significant signal amplification capability of Cas12a/crRNA enzyme as well, we report a simple and highly sensitive method for visual detection of MT, a biomarker in fish for heavy metal ion-induced water bio-pollution. The target MT molecules bind Hg2+ in the Hg2+- complexed hairpin DNA probes to unfold the hairpin structure into ssDNAs, which hybridize with the partial dsDNA duplexes via strand displacement to yield specific sequence-containing dsDNAs. Cas12a/crRNA recognizes these specific sequences to activate its enzyme activity to cyclically cleave the ssDNA linkers in the blue colored gold nanoparticle aggregates to transit their color into red to realize visual detection of MT. Owing to the signal amplification by Cas12a/crRNA, as low as 25 nM of MT can be visually detected with naked eye. In addition, our colorimetric detection method has high selectivity for MT against other interference proteins and can detect MT in the livers and kidneys of crucian carps bought from a local supermarket. Moreover, the developed assay overcomes the limitations of conventional MT detection methods in terms of complexity, high cost and low sensitivity and can therefore offer new methods for monitoring water bio-pollutions.


Asunto(s)
Colorimetría , Sondas de ADN , Peces , Oro , Nanopartículas del Metal , Metalotioneína , Colorimetría/métodos , Animales , Metalotioneína/metabolismo , Metalotioneína/genética , Oro/química , Nanopartículas del Metal/química , Sondas de ADN/química , Sondas de ADN/metabolismo , Sondas de ADN/genética , Peces/metabolismo , Mercurio/análisis , Sistemas CRISPR-Cas , Límite de Detección , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas Biosensibles/métodos
11.
Anal Chem ; 96(24): 9826-9833, 2024 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-38829542

RESUMEN

The rapid and sensitive detection of Escherichia/Shigella genera is crucial for human disease and health. This study introduces a novel series of piezoelectric quartz crystal (SPQC) sensors for detecting Escherichia/Shigella genera. In this innovative biosensor, we propose a new target and novel method for synthesizing long-range DNA. The method relies on the amplification of two DNA probes, referred to as H and P amplification (HPA), resulting in the products of long-range DNA named Sn. The new target was screened from the 16S rRNA gene and utilized as a biomarker. The SPQC sensor operates as follows: the Capture probe is modified on the electrodes. In the presence of a Displace probe and target, the Capture can form a complex with the Displace probe. The resulting complex hybridizes with Sn, bridging the gap between the electrodes. Finally, silver wires are deposited between the electrodes using Sn as a template. This process results in a sensitive response from the SPQC. The detection limit of the SPQC sensor is 1 CFU/mL, and the detection time is within 2 h. This sensor would be of great benefit for food safety monitoring and clinical diagnosis.


Asunto(s)
Técnicas Biosensibles , Escherichia , Técnicas Biosensibles/métodos , Escherichia/genética , ADN Bacteriano/análisis , ADN Bacteriano/genética , ARN Ribosómico 16S/genética , Electrodos , Cuarzo/química , Límite de Detección , Sondas de ADN/química , Humanos , Técnicas de Amplificación de Ácido Nucleico , Técnicas Electroquímicas
12.
Anal Biochem ; 693: 115594, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38897269

RESUMEN

The development of a sensitive and isothermal technique with a greatly enhanced miRNA detection signal is still technically problematic due to the low abundance of miRNA and high sequence similarities with homologous miRNAs. Herein, we propose a novel fluorescence approach for sensitive and reliable miRNA detection by integrating the palindrome sequence mediated target recycling with self-priming assisted signal reaction. In this method, a dual toehold DNA nano-probe (HT) with two functional arms is designed to mediate specific target recognition and signal amplification. In the presence of target miRNA, it binds to the recognition module of HT probe, releasing the "2" sequence to initiate strand displacement amplification (SDA) and a self-priming-induced signal reaction. Based on the elegant design, the proposed method exhibits a wide linear response range exceeding five orders of magnitude and a low limit of detection of 0.96 fM according to the 3δ rule. The non-specific signal is below 5 % for non-target miRNA detection. Taking the merits of excellent sensitivity, desirable specificity, and superior anti-interference ability, the proposed approach shows a promising prospect for detecting miRNAs in complicated biological environments and early diagnosis of diseases.


Asunto(s)
Secuencias Invertidas Repetidas , MicroARNs , Técnicas de Amplificación de Ácido Nucleico , MicroARNs/análisis , MicroARNs/genética , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos , Límite de Detección , Sondas de ADN/química , Sondas de ADN/metabolismo , Espectrometría de Fluorescencia
13.
Anal Chem ; 96(26): 10577-10585, 2024 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-38887964

RESUMEN

Simultaneous detection of multiple breast cancer-associated miRNAs significantly raises the accuracy and reliability of early diagnosis. In this work, disposable carbon fiber paper serves as the biosensing interface, linking DNA probes via click chemistry to efficiently capture targets and signals efficiently. DNA probes have multiple recognition domains that trigger a cascade reaction through the helper probes and targets, resulting in two signals output. The signals are centrally encapsulated in the pore of the MIL-88(Fe)-NH2. The signal carriers are directed by signal probes to the recognition domains that correspond to the DNA probes. The biosensor is selective and stable, and it can quantify miRNA-21 and miRNA-155 simultaneously with detection limits of 0.64 and 0.54 fmol/L, respectively. Furthermore, it demonstrates satisfactory performance in tests conducted with normal human serum and cell lysate. Overall, this method makes a satisfactory exploration to realize an inexpensive and sensitive biosensor for multiple biomarkers.


Asunto(s)
Técnicas Biosensibles , Química Clic , MicroARNs , Técnicas Biosensibles/métodos , Humanos , MicroARNs/análisis , MicroARNs/sangre , Sondas de ADN/química , Neoplasias de la Mama/diagnóstico , Límite de Detección
14.
Talanta ; 276: 126218, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38759363

RESUMEN

In situ monitoring of intracellular microRNAs (miRNAs) often encounters the challenges of surrounding complexity, coexistence of precursor miRNAs (pre-miRNAs) and the degradation of biological enzyme in living cells. Here, we designed a novel probe encapsulated DNA tetrahedral molecular sieve (DTMS) to realize the size-selective detection of intracellular miRNA 21 that can avoid the interference of pre-miRNAs. In such strategy, quencher (BHQ-1) labeled probe DNA (S6-BHQ 1) was introduced into the inner cavity of fluorophore (FAM) labeled DNA tetrahedral scaffolds (DTS) to prepare DTMS, making the FAM and BHQ-1 closely proximate, and resulting the sensor in a "signal-off" state. In the presence of miRNA 21, strand displacement reaction happened to form more stable DNA double-stranded structure, accompanied by the release of S6-BHQ 1 from the inner cavity of DTMS, making the sensor in a "signal-on" state. The DTMS based sensing platform can then realized the size-selective detection of miRNA 21 with a detection limit of 3.6 pM. Relying on the mechanical rigidity of DTS and the encapsulation of DNA probe using DTMS, such proposed method achieved preferable reproducibility and storage stability. Moreover, this sensing system exhibited good performance for monitoring the change of intracellular miRNA 21 level during the treatment with miRNA-related drugs, demonstrating great potential for biological studies and accurate disease diagnosis.


Asunto(s)
ADN , Colorantes Fluorescentes , MicroARNs , MicroARNs/análisis , Humanos , ADN/química , Colorantes Fluorescentes/química , Espectrometría de Fluorescencia/métodos , Límite de Detección , Sondas de ADN/química , Sondas de ADN/genética , Fluorescencia , Técnicas Biosensibles/métodos , Tamaño de la Partícula
15.
Chem Asian J ; 19(14): e202400401, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38725283

RESUMEN

The detection of specific intracellular microRNAs could be potentially helpful in understanding the underlying mechanisms of cancer metastasis and invasion. MiRNAs are usually present in lower expression levels, especially in early stage of cancer. Here, we proposed a "one-to-more" amplification strategy for miRNA imaging, by virtue of DNA strand displacements with dual-amplification. This approach involves leveraging high-abundance endogenous mRNA as fuel strand to drive cascade reactions between DNA strands for amplification, enabling the monitoring of low-abundance intracellular microRNA155. Notably, in comparison to the traditional "one-to-one" signal triggering mode, our "one-to-more" amplification strategy led to a remarkable 11.8-fold increase in fluorescence signal. Our approach not only demonstrates a high sensitivity and specificity in detecting miR155, but also allows for discrimination of miR155 expression levels in different cell lines. With the advantages of intracellular signal amplification and reduced background signal, this approach holds substantial potential in the early diagnosis of cancer.


Asunto(s)
Sondas de ADN , MicroARNs , ARN Mensajero , MicroARNs/análisis , MicroARNs/metabolismo , Humanos , ARN Mensajero/metabolismo , Sondas de ADN/química , Técnicas de Amplificación de Ácido Nucleico , Línea Celular Tumoral
16.
Chembiochem ; 25(15): e202400266, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38801028

RESUMEN

Nucleic acids exhibit exceptional functionalities for both molecular recognition and catalysis, along with the capability of predictable assembly through strand displacement reactions. The inherent programmability and addressability of DNA probes enable their precise, on-demand assembly and accurate execution of hybridization, significantly enhancing target detection capabilities. Decades of research in DNA nanotechnology have led to advances in the structural design of functional DNA probes, resulting in increasingly sensitive and robust DNA sensors. Moreover, increasing attention has been devoted to enhancing the accuracy and sensitivity of DNA-based biosensors by integrating multiple sensing procedures. In this review, we summarize various strategies aimed at enhancing the accuracy of DNA sensors. These strategies involve multiple guarantee procedures, utilizing dual signal output mechanisms, and implementing sequential regulation methods. Our goal is to provide new insights into the development of more accurate DNA sensors, ultimately facilitating their widespread application in clinical diagnostics and assessment.


Asunto(s)
Técnicas Biosensibles , ADN , Técnicas Biosensibles/métodos , ADN/química , ADN/análisis , Humanos , Sondas de ADN/química , Hibridación de Ácido Nucleico , Nanotecnología/métodos
17.
Anal Chem ; 96(23): 9453-9459, 2024 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-38818873

RESUMEN

Selective and sensitive imaging of intracellular mature microRNAs (miRNAs) is of great importance for biological process study and medical diagnostics. However, this goal remains challenging because of the interference of precursor miRNAs (pre-miRNAs) and the low abundance of mature miRNAs. Herein, we develop an endogenous enzyme-driven amplified DNA nanocage probe (Acage) for the selective and sensitive imaging of mature miRNAs in living cells. The Acage consists of a microRNA-responsive probe, an endogenous enzyme-driven fuel strand, and a DNA nanocage framework with an inner cavity. Benefiting from the size selectivity of DNA nanocage, smaller mature miRNAs rather than larger pre-miRNAs are allowed to enter the cavity of DNA nanocage for molecular recognition; thus, Acage can significantly reduce the signal interference of pre-miRNAs. Moreover, with the driving force of an endogenous enzyme apurinic/apyrimidinic endonuclease 1 (APE1) for efficient signal amplification, Acage enables sensitive intracellular miRNA imaging without an additional external intervention. With these features, Acage was successfully applied for intracellular imaging of mature miRNAs during drug treatment. We believe that this strategy provides a promising pathway for better understanding the functions of mature microRNAs in biological processes and medical diagnostics.


Asunto(s)
Sondas de ADN , MicroARNs , MicroARNs/análisis , MicroARNs/metabolismo , Humanos , Sondas de ADN/química , Nanoestructuras/química , Imagen Óptica , Células HeLa
18.
Analyst ; 149(14): 3725-3731, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38757739

RESUMEN

Alpha-synuclein (α-syn) is closely related to the pathological process of Parkinson's disease (PD). Sensitive detection of α-syn is important for the early diagnosis and disease progression monitoring of PD. Herein, we report a binding-triggered hybridization chain reaction (HCR) cascade multi-site activated CRISPR/Cas12a signal amplification strategy for sensitive detection of α-syn. In this method, antibody-DNA capture probes recognized α-syn and bound with it to increase the local effective concentrations of two DNA strands, promoting their hybridization to form a split HCR trigger. Then the trigger initiated an HCR to generate a long double-stranded structure which contained abundant periodically repeated Cas12a/crRNA target sequences. Finally, the Cas12a/crRNA recognized the target sequence in HCR products and then the cleavage activity toward fluorescent reporters was activated, leading to the recovery of appreciable fluorescence signals. Our method provided a detection limit as low as 9.33 pM and exhibited satisfactory applicability in human serum samples. In summary, this study provides a homogeneous strategy for convenient, sensitive, and accurate detection of α-syn, showing great potential in the early diagnosis of PD.


Asunto(s)
Sistemas CRISPR-Cas , Límite de Detección , Hibridación de Ácido Nucleico , alfa-Sinucleína , Humanos , Técnicas Biosensibles/métodos , Sondas de ADN/química , Sondas de ADN/genética , Enfermedad de Parkinson/diagnóstico , Espectrometría de Fluorescencia/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Colorantes Fluorescentes/química , Proteínas Bacterianas/química , Proteínas Bacterianas/genética , Proteínas Asociadas a CRISPR/química , Endodesoxirribonucleasas/química
19.
Chem Commun (Camb) ; 60(36): 4777-4780, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38597795

RESUMEN

A cubic DNA nanocage probe is able to enter EVs derived from MDA-MB-231 cells and react with miRNA-10b. The probe-loaded EVs were employed to monitor the process of entry of miRNA-10b into MCF-10A cells, allowing visualization of EV-mediated intercellular communication of miRNA-10b between the cancer cells.


Asunto(s)
Vesículas Extracelulares , MicroARNs , Humanos , MicroARNs/análisis , MicroARNs/metabolismo , Vesículas Extracelulares/química , Vesículas Extracelulares/metabolismo , Línea Celular Tumoral , Sondas de ADN/química , Nanoestructuras/química
20.
Talanta ; 274: 125999, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38583327

RESUMEN

The construction of efficient methods for highly sensitive and rapid detection of disease markers is essential for the early diagnosis of serious diseases. In this paper, taking advantage of the UiO-66-NH2 signal molecule in combination with a waste-free entropy-driven DNA machine, a novel homogeneous electrochemical ratiometric platform is developed to detect MircoRNA (miRNA). Metal-organic framework materials (UiO-66-NH2 MOF) and ferrocene were utilized as electrochemical signal tags and reference probes, respectively. The target-initiated waste-free three-dimensional (3D) entropy-driven DNA nanomachine is activated in the presence of miRNA, resulting in DNA-labeled-UiO-66-NH2 falling off from the electrode, leading to a decrease in the signal of UiO-66-NH2 at 0.83V. Our strategy can mitigate false positive responses induced by the DNA probes immobilized on electrodes in traditional distance-dependent signal adjustment ratiometric strategies. The proposed ratiometric platform demonstrates superior sensitivity (a detection limit of 9.8 fM), simplified operation, high selectivity, and high repeatability. The ratiometric biosensor is also applied to detect miRNA content in spiked serum samples.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Entropía , Estructuras Metalorgánicas , MicroARNs , MicroARNs/sangre , MicroARNs/análisis , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Humanos , Estructuras Metalorgánicas/química , ADN/química , Límite de Detección , Electrodos , Sondas de ADN/química , Sondas de ADN/genética , Compuestos Ferrosos/química , Metalocenos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA