Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 62(6): 1080-1091, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38205643

RESUMEN

OBJECTIVES: Current liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications for circulating androgen measurements are technically diverse. Previously, variable results have been reported for testosterone. Data are scarce for androstenedione and absent for dehydroepiandrosterone sulfate (DHEAS). We assessed the agreement of androstenedione, DHEAS and testosterone LC-MS/MS measurements among nine European centers and explored benefits of calibration system unification. METHODS: Androgens were measured twice by laboratory-specific procedures in 78 patient samples and in EQA materials. Results were obtained by in-house and external calibration. Intra- and inter-laboratory performances were valued. RESULTS: Intra-laboratory CVs ranged between 4.2-13.2 % for androstenedione, 1.6-10.8 % for DHEAS, and 4.3-8.7 % and 2.6-7.1 % for female and male testosterone, respectively. Bias and trueness in EQA materials were within ±20 %. Median inter-laboratory CV with in-house vs. external calibration were 12.0 vs. 9.6 % for androstenedione (p<0.001), 7.2 vs. 4.9 % for DHEAS (p<0.001), 6.4 vs. 7.6 % for female testosterone (p<0.001) and 6.8 and 7.4 % for male testosterone (p=0.111). Median bias vs. all laboratory median with in-house and external calibration were -13.3 to 20.5 % and -4.9 to 18.7 % for androstenedione, -10.9 to 4.8 % and -3.4 to 3.5 % for DHEAS, -2.7 to 6.5 % and -11.3 to 6.6 % for testosterone in females, and -7.0 to 8.5 % and -7.5 to 11.8 % for testosterone in males, respectively. CONCLUSIONS: Methods showed high intra-laboratory precision but variable bias and trueness. Inter-laboratory agreement was remarkably good. Calibration system unification improved agreement in androstenedione and DHEAS, but not in testosterone measurements. Multiple components, such as commutability of calibrators and EQA materials and internal standard choices, likely contribute to inter-laboratory variability.


Asunto(s)
Androstenodiona , Sulfato de Deshidroepiandrosterona , Espectrometría de Masas en Tándem , Testosterona , Androstenodiona/sangre , Androstenodiona/análisis , Testosterona/sangre , Testosterona/análisis , Testosterona/normas , Humanos , Espectrometría de Masas en Tándem/normas , Espectrometría de Masas en Tándem/métodos , Calibración , Masculino , Femenino , Cromatografía Liquida/normas , Cromatografía Liquida/métodos , Sulfato de Deshidroepiandrosterona/sangre , Sulfato de Deshidroepiandrosterona/análisis , Sulfato de Deshidroepiandrosterona/normas , Persona de Mediana Edad , Cromatografía Líquida con Espectrometría de Masas
2.
Anal Biochem ; 610: 113984, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33039429

RESUMEN

Immunoassay overestimates progesterone in blood, but no studies have tested whether this occurs in saliva. We measured progesterone in saliva using immunoassay and mass spectrometry. We tested the immunoassay for cross reactivity with dehydroepiandrosterone sulfate (DHEA-S) and 17α-hydroxyprogesterone (17α-OHP). Progesterone was significantly higher in immunoassay compared to mass spectrometry. Immunoassay progesterone levels increased in when incremental levels of 17α-OHP standard was added. This effect was not observed with the addition of DHEA-S. Research using salivary progesterone immunoassay techniques should be wary, particularly with individuals taking steroid supplementation or with high levels of progesterone metabolites.


Asunto(s)
Inmunoensayo , Progesterona/análisis , Saliva/química , Espectrometría de Masas en Tándem , 17-alfa-Hidroxiprogesterona/análisis , 17-alfa-Hidroxiprogesterona/normas , Adulto , Cromatografía Líquida de Alta Presión , Sulfato de Deshidroepiandrosterona/análisis , Sulfato de Deshidroepiandrosterona/normas , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA