1.
Phys Med Biol ; 69(18)2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39241801

RESUMEN

Objective.Newer generation linear accelerators (Linacs) allow 20 s cone-beam CT (CBCT) acquisition which reduces radiation therapy treatment time. However, the current clinical application of these rapid scans is only 3DCBCT. In this paper we propose a novel data-driven rapid 4DCBCT reconstruction method for new generation linacs.Approach.This method relies on estimating the magnitude of the diaphragm motion from an initial 3D reconstruction. This estimated motion is used to linearly approximate a deformation vector field (DVF) for each respiration phase. These DVFs are then used for motion compensated Feldkamp-Davis-Kress (MCFDK) reconstructions. This method, named MCFDK Data Driven (MCFDK-DD), was compared to a MCFDK reconstruction using a prior motion model (MCFDK-Prior), a 3D-FDK reconstruction, and a conventional acquisition (4 mins) conventional reconstruction 4DCBCT (4D-FDK). The data used in this paper were derived from 4DCT volumes from 12 patients from The Cancer Imaging Archives. Image quality was quantified using RMSE of line plots centred on the tumour, tissue interface width (TIW), the mean square error (MSE) and structural similarity index measurement (SSIM).Main Results.The tumour line plots in the Superior-Inferior direction showed reduced RMSE for the MCFDK-DD compared to the 3D-FDK method, indicating the MCFDK-DD method provided a more accurate tumour location. Similarly, the TIW values from the MCFDK-DD reconstructions (median 8.6 mm) were significantly reduced for the MCFDK-DD method compared to the 3D-FDK reconstructions (median 14.8 mm, (p< 0.001). The MCFDK-DD, MCFDK-Prior and 3D-FDK had median MSE values of1.08×10-6mm-1,1.11×10-6mm-1and1.17×10-6mm-1respectively. The corresponding median SSIM values were 0.93, 0.92 and 0.92 respectively indicating the MCFDK-DD had good agreement with the conventional 4D-FDK reconstructions.Significance.These results demonstrate the feasibility of creating accurate data-driven 4DCBCT images for rapid scans on new generation linacs. These findings could lead to increased clinical usage of 4D information on newer generation linacs.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Aceleradores de Partículas , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Factores de Tiempo , Respiración , Movimiento
2.
Radiat Oncol ; 19(1): 117, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39252032

RESUMEN

BACKGROUND: The interaction between breathing motion and scanning beams causes interplay effects in spot-scanning proton therapy for lung cancer, resulting in compromised treatment quality. This study investigated the effects and clinical robustness of two types of spot-scanning proton therapy with motion-mitigation techniques for locally advanced non-small cell lung cancer (NSCLC) using a new simulation tool (4DCT-based dose reconstruction). METHODS: Three-field single-field uniform dose (SFUD) and robustly optimized intensity-modulated proton therapy (IMPT) plans combined with gating and re-scanning techniques were created using a VQA treatment planning system for 15 patients with locally advanced NSCLC (70 GyRBE/35 fractions). In addition, gating windows of three or five phases around the end-of-expiration phase and two internal gross tumor volumes (iGTVs) were created, and a re-scanning number of four was used. First, the static dose (SD) was calculated using the end-of-expiration computed tomography (CT) images. The four-dimensional dynamic dose (4DDD) was then calculated using the SD plans, 4D-CT images, and the deformable image registration technique on end-of-expiration CT. The target coverage (V98%, V100%), homogeneity index (HI), and conformation number (CN) for the iGTVs and organ-at-risk (OAR) doses were calculated for the SD and 4DDD groups and statistically compared between the SD, 4DDD, SFUD, and IMPT treatment plans using paired t-test. RESULTS: In the 3- and 5-phase SFUD, statistically significant differences between the SD and 4DDD groups were observed for V100%, HI, and CN. In addition, statistically significant differences were observed for V98%, V100%, and HI in phases 3 and 5 of IMPT. The mean V98% and V100% in both 3-phase plans were within clinical limits (> 95%) when interplay effects were considered; however, V100% decreased to 89.3% and 94.0% for the 5-phase SFUD and IMPT, respectively. Regarding the significant differences in the deterioration rates of the dose volume histogram (DVH) indices, the 3-phase SFUD plans had lower V98% and CN values and higher V100% values than the IMPT plans. In the 5-phase plans, SFUD had higher deterioration rates for V100% and HI than IMPT. CONCLUSIONS: Interplay effects minimally impacted target coverage and OAR doses in SFUD and robustly optimized IMPT with 3-phase gating and re-scanning for locally advanced NSCLC. However, target coverage significantly declined with an increased gating window. Robustly optimized IMPT showed superior resilience to interplay effects, ensuring better target coverage, prescription dose adherence, and homogeneity than SFUD. TRIAL REGISTRATION: None.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Terapia de Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Pulmonares/radioterapia , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada Cuatridimensional/métodos , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Radioterapia de Intensidad Modulada/métodos , Masculino , Femenino , Órganos en Riesgo/efectos de la radiación , Persona de Mediana Edad , Anciano , Respiración , Movimiento (Física)
3.
J Biomech ; 174: 112269, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39128410

RESUMEN

Recent studies have suggested that irregular pulsation of intracranial aneurysm during the cardiac cycle may be potentially associated with aneurysm rupture risk. However, there is a lack of quantification method for irregular pulsations. This study aims to quantify irregular pulsations by the displacement and strain distribution of the intracranial aneurysm surface during the cardiac cycle using four-dimensional CT angiographic image data. Four-dimensional CT angiography was performed in 8 patients. The image data of a cardiac cycle was divided into approximately 20 phases, and irregular pulsations were detected in four intracranial aneurysms by visual observation, and then the displacement and strain of the intracranial aneurysm was quantified using coherent point drift and finite element method. The displacement and strain were compared between aneurysms with irregular and normal pulsations in two different ways (total and stepwise). The stepwise first principal strain was significantly higher in aneurysms with irregular than normal pulsations (0.20±0.01 vs 0.16±0.02, p=0.033). It was found that the irregular pulsations in intracranial aneurysms usually occur during the consecutive ascending or descending phase of volume changes during the cardiac cycle. In addition, no statistically significant difference was found in the aneurysm volume changes over the cardiac cycle between the two groups. Our method can successfully quantify the displacement and strain changes in the intracranial aneurysm during the cardiac cycle, which may be proven to be a useful tool to quantify intracranial aneurysm deformability and aid in aneurysm rupture risk assessment.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/fisiopatología , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Tomografía Computarizada Cuatridimensional/métodos , Anciano , Angiografía por Tomografía Computarizada/métodos , Adulto , Flujo Pulsátil
4.
Asian Pac J Cancer Prev ; 25(8): 2861-2868, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39205584

RESUMEN

OBJECTIVE: This study addresses challenges in delivering high radiation doses and managing organ motion in Stereotactic Body Radiation Therapy (SBRT) for thoracic and abdominal cancer. It evaluates Varian's Real Time Position Management (RPM) system's infrared camera sensitivity during crucial Four-Dimensional computed tomography (4D-CT) scans for planning and treatment. The analysis includes CT simulator, LINAC (Novalis Tx and TrueBeam STx). This research enhances SBRT precision by offering insights into RPM and RGSC system performance across machines, impacting treatment planning and delivery optimization. METHODS: The QUASAR™ Respiratory Motion Assembly phantom is aligned with precision using lasers. It is configured with either six-dot reflective or four-dot lens marker blocks featuring a retroreflective marker placed on the phantom's surface. Motion is induced by adjusting the amplitude, and the camera position is finely tuned to monitor the marker's movements. This investigation entails variations in seconds per breath (SPB) within the Quasar breath platform, specifically at intervals of 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, and 5.0 seconds while maintaining a 1cm amplitude camera setting. RESULT: For TrueBeam-STx: Ensure SPB values are kept above 1.8 seconds for accurate replication. For Novalis-Tx: Stay within an SPB range of up to 2.0 seconds for reliable reproducibility. For CT Simulator: Optimal replication up to an SPB of 2.2 seconds; avoid SPB values below 1.8 seconds for reliable detection. CONCLUSION: Data for TrueBeam-STx, Novalis-Tx, and the CT simulator shows discrepancies in replicating the breathing cycle as Seconds Per Breath (SPB) decreases. Effective Infrared (IR) sensitivity is observed until SPB thresholds: 1.8s (TrueBeam-STx), 2.2s (Novalis-Tx), and 2.2s (CT simulator). We should consider values equal to or greater than the mentioned breathing periods. Variations in replicating breathing cycles signal challenges in planning and delivering treatments, especially with lower SPB values. These insights guide clinicians to adapt treatments based on machine-specific capabilities for accurate and reproducible outcomes.


Asunto(s)
Fantasmas de Imagen , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Respiración , Rayos Infrarrojos , Tomografía Computarizada Cuatridimensional/métodos
5.
BMC Musculoskelet Disord ; 25(1): 589, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060988

RESUMEN

BACKGROUND: This study validated the accuracy of the acromion marker cluster (AMC) and scapula spinal marker cluster (SSMC) methods compared with upright four-dimensional computed tomography (4DCT) analysis. METHODS: Sixteen shoulders of eight healthy males underwent AMC and SSMC assessments. Active shoulder elevation was tracked using upright 4DCT and optical motion capture system. The scapulothoracic and glenohumeral rotation angles calculated from AMC and SSMC were compared with 4DCT. Additionally, the motion of these marker clusters on the skin with shoulder elevation was evaluated. RESULTS: The average differences between AMC and 4DCT during 10°-140° of humerothoracic elevation were - 2.2° ± 7.5° in scapulothoracic upward rotation, 14.0° ± 7.4° in internal rotation, 6.5° ± 7.5° in posterior tilting, 3.7° ± 8.1° in glenohumeral elevation, - 8.3° ± 10.7° in external rotation, and - 8.6° ± 8.9° in anterior plane of elevation. The difference between AMC and 4DCT was significant at 120° of humerothoracic elevation in scapulothoracic upward rotation, 50° in internal rotation, 90° in posterior tilting, 120° in glenohumeral elevation, 100° in external rotation, and 100° in anterior plane of elevation. However, the average differences between SSMC and 4DCT were - 7.5 ± 7.7° in scapulothoracic upward rotation, 2.0° ± 7.0° in internal rotation, 2.3° ± 7.2° in posterior tilting, 8.8° ± 7.9° in glenohumeral elevation, 2.0° ± 9.1° in external rotation, and 1.9° ± 10.1° in anterior plane of elevation. The difference between SSMC and 4DCT was significant at 50° of humerothoracic elevation in scapulothoracic upward rotation and 60° in glenohumeral elevation, with no significant differences observed in other rotations. Skin motion was significantly smaller in AMC (28.7 ± 4.0 mm) than SSMC (38.6 ± 5.8 mm). Although there was smaller skin motion in AMC, SSMC exhibited smaller differences in scapulothoracic internal rotation, posterior tilting, glenohumeral external rotation, and anterior plane of elevation compared to 4DCT. CONCLUSION: This study demonstrates that AMC is more accurate for assessing scapulothoracic upward rotation and glenohumeral elevation, while SSMC is preferable for evaluating scapulothoracic internal rotation, posterior tilting, glenohumeral external rotation, and anterior plane of elevation, with smaller differences compared to 4DCT.


Asunto(s)
Acromion , Tomografía Computarizada Cuatridimensional , Rango del Movimiento Articular , Escápula , Articulación del Hombro , Humanos , Masculino , Escápula/diagnóstico por imagen , Escápula/fisiología , Tomografía Computarizada Cuatridimensional/métodos , Adulto , Fenómenos Biomecánicos/fisiología , Acromion/diagnóstico por imagen , Acromion/fisiología , Rango del Movimiento Articular/fisiología , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiología , Adulto Joven , Rotación
6.
Biomed Phys Eng Express ; 10(5)2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39053487

RESUMEN

Objective. Digital tomosynthesis (DTS) is a type of limited-angle Computed Tomography (CT) used in orthopedic and oncology care to provide a pseudo-3D reconstructed volume of a body part from multiple x-ray projections. Patient motion during acquisitions results in artifacts which affect screening and diagnostic performances. Hence, accurate reconstruction of moving body parts from a tomosynthesis projection series is addressed in this paper, with a particular focus on the breast. The aim of this paper is to assess the feasibility of a novel dynamic reconstruction technique for DTS and evaluate its accuracy compared to an available ground truth.Approach. The proposed method is a combination of a 4D dynamic tomography strategy leveraging the formalism of Projection-based Digital Volume Correlation (P-DVC) with a multiscale approach to estimate and correct patient motion. Iterations of two operations are performed: (i) a motion-corrected reconstruction based on the Simultaneous Iterative Reconstruction Technique (SIRT) algorithm and (ii) a motion estimation from projection residuals, to obtain motion-free volumes. Performance is evaluated on a synthetic Digital Breast Tomosynthesis (DBT) case. Three slabs of a CIRS breast phantom are imaged on a Senographe PristinaTM, under plate-wise rigid body motions with amplitudes ranging up to 10 mm so that an independent measurement of the motion can be accessed.Results. Results show a motion estimation average precision down to 0.183 mm (1.83 voxels), when compared to the independent measurement. Moreover, an 84.2% improvement on the mean residual error and a 59.9% improvement on the root mean square error (RMSE) with the original static reconstruction are obtained.Significance. Visual and quantitative assessments of the dynamically reconstructed volumes show that the proposed method fully restores conspicuity for important clinical features contained in the phantom.


Asunto(s)
Algoritmos , Neoplasias de la Mama , Mama , Procesamiento de Imagen Asistido por Computador , Mamografía , Fantasmas de Imagen , Humanos , Femenino , Mama/diagnóstico por imagen , Mamografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias de la Mama/diagnóstico por imagen , Artefactos , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada Cuatridimensional/métodos , Movimiento
7.
J Cancer Res Clin Oncol ; 150(7): 359, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39044013

RESUMEN

BACKGROUND: In single-isocenter multitarget stereotactic body radiotherapy (SBRT), geometric miss risks arise from uncertainties in intertarget position. However, its assessment is inadequate, and may be interfered by the reconstructed tumor position errors (RPEs) during simulated CT and cone beam CT (CBCT) acquisition. This study aimed to quantify intertarget position variations and assess factors influencing it. METHODS: We analyzed data from 14 patients with 100 tumor pairs treated with single-isocenter SBRT. Intertarget position variation was measured using 4D-CT simulation to assess the intertarget position variations (ΔD) during routine treatment process. Additionally, a homologous 4D-CBCT simulation provided RPE-free comparison to determine the impact of RPEs, and isolating purely tumor motion induced ΔD to evaluate potential contributing factors. RESULTS: The median ΔD was 4.3 mm (4D-CT) and 3.4 mm (4D-CBCT). Variations exceeding 5 mm and 10 mm were observed in 31.1% and 5.5% (4D-CT) and 20.4% and 3.4% (4D-CBCT) of fractions, respectively. RPEs necessitated an additional 1-2 mm safety margin. Intertarget distance and breathing amplitude variability showed weak correlations with variation (Rs = 0.33 and 0.31). The ΔD differed significantly by locations (upper vs. lower lobe and right vs. Left lung). Notably, left lung tumor pairs exhibited the highest risk. CONCLUSIONS: This study provide a reliable way to assess intertarget position variation by using both 4D-CT and 4D-CBCT simulation. Consequently, single-isocenter SBRT for multiple lung tumors carries high risk of geometric miss. Tumor motion and RPE constitute a substantial portion of intertarget position variation, requiring correspondent strategies to minimize the intertarget uncertainties.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiocirugia/métodos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/patología , Tomografía Computarizada de Haz Cónico/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Masculino , Femenino , Anciano , Simulación por Computador , Persona de Mediana Edad
8.
Sci Rep ; 14(1): 12589, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824238

RESUMEN

In order to study how to use pulmonary functional imaging obtained through 4D-CT fusion for radiotherapy planning, and transform traditional dose volume parameters into functional dose volume parameters, a functional dose volume parameter model that may reduce level 2 and above radiation pneumonia was obtained. 41 pulmonary tumor patients who underwent 4D-CT in our department from 2020 to 2023 were included. MIM Software (MIM 7.0.7; MIM Software Inc., Cleveland, OH, USA) was used to register adjacent phase CT images in the 4D-CT series. The three-dimensional displacement vector of CT pixels was obtained when changing from one respiratory state to another respiratory state, and this three-dimensional vector was quantitatively analyzed. Thus, a color schematic diagram reflecting the degree of changes in lung CT pixels during the breathing process, namely the distribution of ventilation function strength, is obtained. Finally, this diagram is fused with the localization CT image. Select areas with Jacobi > 1.2 as high lung function areas and outline them as fLung. Import the patient's DVH image again, fuse the lung ventilation image with the localization CT image, and obtain the volume of fLung different doses (V60, V55, V50, V45, V40, V35, V30, V25, V20, V15, V10, V5). Analyze the functional dose volume parameters related to the risk of level 2 and above radiation pneumonia using R language and create a predictive model. By using stepwise regression and optimal subset method to screen for independent variables V35, V30, V25, V20, V15, and V10, the prediction formula was obtained as follows: Risk = 0.23656-0.13784 * V35 + 0.37445 * V30-0.38317 * V25 + 0.21341 * V20-0.10209 * V15 + 0.03815 * V10. These six independent variables were analyzed using a column chart, and a calibration curve was drawn using the calibrate function. It was found that the Bias corrected line and the Apparent line were very close to the Ideal line, The consistency between the predicted value and the actual value is very good. By using the ROC function to plot the ROC curve and calculating the area under the curve: 0.8475, 95% CI 0.7237-0.9713, it can also be determined that the accuracy of the model is very high. In addition, we also used Lasso method and random forest method to filter out independent variables with different results, but the calibration curve drawn by the calibration function confirmed poor prediction performance. The function dose volume parameters V35, V30, V25, V20, V15, and V10 obtained through 4D-CT are key factors affecting radiation pneumonia. Establishing a predictive model can provide more accurate lung restriction basis for clinical radiotherapy planning.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Neumonitis por Radiación , Humanos , Neumonitis por Radiación/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Femenino , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Anciano , Pulmón/diagnóstico por imagen , Pulmón/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Adulto
9.
J Nucl Med Technol ; 52(2): 86-90, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839121

RESUMEN

Our rationale was to review the imaging options for patients with primary hyperparathyroidism and to advocate for judicious use of 4-dimensional (4D) SPECT/CT to visualize diseased parathyroid glands in patients with complex medical profiles or in whom other imaging modalities fail. We review the advantages and disadvantages of traditional imaging modalities used in preoperative assessment of patients with primary hyperparathyroidism: ultrasound, SPECT, and 4D CT. We describe a scheme for optimizing and individualizing preoperative imaging of patients with hyperfunctioning parathyroid glands using traditional modalities in tandem with 4D SPECT/CT. Using the input from radiologists, endocrinologists, and surgeons, we apply patient criteria such as large body habitus, concomitant multiglandular disease, multinodular thyroid disease, confusing previous imaging, and unsuccessful previous surgery to create an imaging paradigm that uses 4D SPECT/CT yet is cost-effective, accurate, and limits extraneous radiation exposure. 4D SPECT/CT capitalizes on the strengths of SPECT and 4D CT and addresses limitations that exist when these modalities are used in isolation. In select patients with complicated clinical parameters, preoperative imaging with 4D SPECT/CT can improve accuracy yet remain cost-effective.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Hiperparatiroidismo Primario , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/cirugía , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada Cuatridimensional/métodos
10.
Biomed Phys Eng Express ; 10(4)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38861951

RESUMEN

Objective.We aim to: (1) quantify the benefits of lung sparing using non-adaptive magnetic resonance guided stereotactic body radiotherapy (MRgSBRT) with advanced motion management for peripheral lung cancers compared to conventional x-ray guided SBRT (ConvSBRT); (2) establish a practical decision-making guidance metric to assist a clinician in selecting the appropriate treatment modality.Approach.Eleven patients with peripheral lung cancer who underwent breath-hold, gated MRgSBRT on an MR-guided linear accelerator (MR linac) were studied. Four-dimensional computed tomography (4DCT)-based retrospective planning using an internal target volume (ITV) was performed to simulate ConvSBRT, which were evaluated against the original MRgSBRT plans. Metrics analyzed included planning target volume (PTV) coverage, various lung metrics and the generalized equivalent unform dose (gEUD). A dosimetric predictor for achievable lung metrics was derived to assist future patient triage across modalities.Main results.PTV coverage was high (median V100% > 98%) and comparable for both modalities. MRgSBRT had significantly lower lung doses as measured by V20 (median 3.2% versus 4.2%), mean lung dose (median 3.3 Gy versus 3.8 Gy) and gEUD. Breath-hold, gated MRgSBRT resulted in an average reduction of 47% in PTV volume and an average increase of 19% in lung volume. Strong correlation existed between lung metrics and the ratio of PTV to lung volumes (RPTV/Lungs) for both modalities, indicating that RPTV/Lungsmay serve as a good predictor for achievable lung metrics without the need for pre-planning. A threshold value of RPTV/Lungs< 0.035 is suggested to achieve V20 < 10% using ConvSBRT. MRgSBRT should otherwise be considered if the threshold cannot be met.Significance.The benefits of lung sparing using MRgSBRT were quantified for peripheral lung tumors; RPTV/Lungswas found to be an effective predictor for achievable lung metrics across modalities. RPTV/Lungscan assist a clinician in selecting the appropriate modality without the need for labor-intensive pre-planning, which has significant practical benefit for a busy clinic.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Pulmón , Imagen por Resonancia Magnética , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Pulmón/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada Cuatridimensional/métodos , Masculino , Femenino , Radioterapia Guiada por Imagen/métodos , Contencion de la Respiración , Anciano , Persona de Mediana Edad , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo
11.
Eur J Radiol ; 177: 111544, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38917580

RESUMEN

OBJECTIVES: To evaluate the diagnostic performance of simplified post-processing approaches for quantitative wrist 4D-CT in the assessment of scapholunate instability (SLI). METHODS: A prospective monocentric case-control study included 60 patients with suspected post-traumatic scapholunate ligament (SLL) tears and persistent pain. Of these, 40 patients exhibited SLL tears, subdivided into two groups of 20 each: one group with completely torn ligaments and the other with partially torn ligaments. The remaining 20 patients, whose SLLs were intact, served as controls. 4D-CT and CT arthrography were performed, and post-processed by two readers using three approaches: the standard method with full data assessment and dedicated software, partial data assessment with post-processing software (bone locking), and partial data assessment without post-processing software (no bone locking). The scapholunate gap (SLG) parameter was measured in millimeters to evaluate scapholunate diastasis during radioulnar deviation (RUD). The scapholunate ligament status on CT arthrography was considered the gold standard. RESULTS: The SLG-derived parameters (range, mean, and maximal values) were significantly increased in patients with both intact and torn scapholunate ligaments across all post-processing approaches (P values ranging from 0.001 to 0.004). SLG range was the best parameter for diagnosing SLL tears, with ROC AUC values ranging from 0.7 to 0.88 across the three post-processing methods. The interobserver reproducibility was better with the alternative approaches (ICC values 0.93-0.96) compared to the standard approach (ICC values 0.65-0.72). Additionally, post-processing time was shorter with the alternative approaches, especially when specific software was not used (reduced from 10 to three minutes). CONCLUSION: Simpler approaches to wrist 4D-CT data analysis yielded acceptable diagnostic performances and improved interobserver reproducibility compared to the standard approach.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Inestabilidad de la Articulación , Hueso Semilunar , Hueso Escafoides , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Femenino , Masculino , Adulto , Estudios de Casos y Controles , Estudios Prospectivos , Hueso Semilunar/diagnóstico por imagen , Hueso Escafoides/diagnóstico por imagen , Hueso Escafoides/lesiones , Tomografía Computarizada Cuatridimensional/métodos , Persona de Mediana Edad , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/lesiones , Traumatismos de la Muñeca/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Articulación de la Muñeca/diagnóstico por imagen , Adulto Joven
12.
Med Phys ; 51(8): 5164-5180, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38922912

RESUMEN

Cone-beam CT (CBCT) is the most commonly used onboard imaging technique for target localization in radiation therapy. Conventional 3D CBCT acquires x-ray cone-beam projections at multiple angles around the patient to reconstruct 3D images of the patient in the treatment room. However, despite its wide usage, 3D CBCT is limited in imaging disease sites affected by respiratory motions or other dynamic changes within the body, as it lacks time-resolved information. To overcome this limitation, 4D-CBCT was developed to incorporate a time dimension in the imaging to account for the patient's motion during the acquisitions. For example, respiration-correlated 4D-CBCT divides the breathing cycles into different phase bins and reconstructs 3D images for each phase bin, ultimately generating a complete set of 4D images. 4D-CBCT is valuable for localizing tumors in the thoracic and abdominal regions where the localization accuracy is affected by respiratory motions. This is especially important for hypofractionated stereotactic body radiation therapy (SBRT), which delivers much higher fractional doses in fewer fractions than conventional fractionated treatments. Nonetheless, 4D-CBCT does face certain limitations, including long scanning times, high imaging doses, and compromised image quality due to the necessity of acquiring sufficient x-ray projections for each respiratory phase. In order to address these challenges, numerous methods have been developed to achieve fast, low-dose, and high-quality 4D-CBCT. This paper aims to review the technical developments surrounding 4D-CBCT comprehensively. It will explore conventional algorithms and recent deep learning-based approaches, delving into their capabilities and limitations. Additionally, the paper will discuss the potential clinical applications of 4D-CBCT and outline a future roadmap, highlighting areas for further research and development. Through this exploration, the readers will better understand 4D-CBCT's capabilities and potential to enhance radiation therapy.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Radioterapia Guiada por Imagen/métodos , Respiración
13.
Cancer Radiother ; 28(3): 229-235, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38871604

RESUMEN

PURPOSE: The main objective of this study was to assess inter- and intrafraction errors for two patient immobilisation devices in the context of lung stereotactic body radiation therapy: a vacuum cushion and a simple arm support. MATERIALS AND METHODS: Twenty patients who were treated with lung stereotactic body radiation therapy in supine position with arms above their head were included in the study. Ten patients were setup in a vacuum cushion (Bluebag™, Elekta) and ten other patients with a simple arm support (Posirest™, Civco). A pretreatment four-dimensional cone-beam computed tomography and a post-treatment three-dimensional cone-beam computed tomography were acquired to compare positioning and immobilisation accuracy. Based on a rigid registration with the planning computed tomography on the spine at the target level, translational and rotational errors were reported. RESULTS: The median number of fractions per treatment was 5 (range: 3-10). Mean interfraction errors based on 112 four-dimensional cone-beam computed tomographies were similar for both setups with deviations less than or equal to 1.3mm in lateral and vertical direction and 1.2° in roll and yaw. For longitudinal translational errors, mean interfraction errors were 0.7mm with vacuum cushion and -3.9mm with arm support. Based on 111 three-dimensional cone-beam computed tomographies, mean lateral, longitudinal and vertical intrafraction errors were -0.1mm, -0.2mm and 0.0mm respectively (SD: 1.0, 1.2 and 1.0mm respectively) for the patients setup with vacuum cushion, and mean vertical, longitudinal and lateral intrafraction errors were -0.3mm, -0.7mm and 0.1mm respectively (SD: 2.3, 1.8 and 1.4mm respectively) for the patients setup with arm support. Intrafraction errors means were not statistically different between both positions but standard deviations were statistically larger with arm support. CONCLUSION: The results of our study showed similar inter and intrafraction mean deviations between both positioning but a large variability in intrafraction observed with arm support suggested a more accurate immobilization with vacuum cushion.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Inmovilización , Neoplasias Pulmonares , Posicionamiento del Paciente , Radiocirugia , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Inmovilización/métodos , Inmovilización/instrumentación , Estudios Prospectivos , Anciano , Femenino , Masculino , Persona de Mediana Edad , Tomografía Computarizada de Haz Cónico/métodos , Anciano de 80 o más Años , Errores de Configuración en Radioterapia/prevención & control , Fraccionamiento de la Dosis de Radiación , Posición Supina , Tomografía Computarizada Cuatridimensional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Vacio
14.
Acta Oncol ; 63: 448-455, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899392

RESUMEN

BACKGROUND: Robust optimization has been suggested as an approach to reduce the irradiated volume in lung Stereotactic Body Radiation Therapy (SBRT). We performed a retrospective planning study to investigate the potential benefits over Planning Target Volume (PTV)-based planning. MATERIAL AND METHODS: Thirty-nine patients had additional plans using robust optimization with 5-mm isocenter shifts of the Gross Tumor Volume (GTV) created in addition to the PTV-based plan used for treatment. The optimization included the mid-position phase and the extreme breathing phases of the 4D-CT planning scan. The plans were compared for tumor coverage, isodose volumes, and doses to Organs At Risk (OAR). Additionally, we evaluated both plans with respect to observed tumor motion using the peak tumor motion seen on the planning scan and cone-beam CTs. RESULTS: Statistically significant reductions in irradiated isodose volumes and doses to OAR were achieved with robust optimization, while preserving tumor dose. The reductions were largest for the low-dose volumes and reductions up to 188 ccm was observed. The robust evaluation based on observed peak tumor motion showed comparable target doses between the two planning methods. Accumulated mean GTV-dose was increased by a median of 4.46 Gy and a non-significant increase of 100 Monitor Units (MU) was seen in the robust optimized plans. INTERPRETATION: The robust plans required more time to prepare, and while it might not be a feasible planning strategy for all lung SBRT patients, we suggest it might be useful for selected patients.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Órganos en Riesgo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Órganos en Riesgo/efectos de la radiación , Tomografía Computarizada Cuatridimensional/métodos , Tomografía Computarizada de Haz Cónico , Masculino , Fotones/uso terapéutico , Femenino , Anciano
15.
Asian Pac J Cancer Prev ; 25(6): 2089-2098, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38918671

RESUMEN

PURPOSE: The study aimed to validate a method for minimizing phase errors by combining full-length lung 4DCT (f4DCT) scans with shorter tumor-restricted 4DCT (s4DCT) scans. It assessed the feasibility of integrating two scans one covering the entire phantom length and the other focused on the tumor area. The study also evaluated the impact of Maximum Intensity Projection (MIP) volume and imaging dose for different slice thicknesses (2.5mm and 1.25mm) in both full-length and short target-restricted 4DCT scans. METHODS: The study utilized the Quasar Programmable Respiratory Motion Phantom, simulating tumor motion with a variable lung insert. The setup included a tumor replica and a six-dot IR reflector marker on the breathing platform. The objective was to analyze volume differences in fMIP_2.5mm compared to sMIP_1.25mm within their respective 4D_MIP CT series. This involved varying breathing periods (2.5s, 3.0s, 4.0s, and 5.0s) and longitudinal tumor sizes (6mm, 8mm, and 10mm). The study also assessed exposure time and expected CTDIvol of s4D_2.5mm and s4D_1.25mm for different breathing periods (5.0s to 2.0s) in the sinusoidal wave motion of the six-dot marker on the breathing platform. RESULTS: Conducting two consecutive 4DCT scans is viable for patients with challenging breathing patterns or when the initial lung tumor scan is in close proximity to the tumor location, eliminating the need for an additional full-length 4DCT. The analysis involves assessing MIP volume, imaging dose (CTDIvol), and exposure time. Longitudinal tumor shifts for 6mm are [16.6-17.2] in fMIP_2.5mm and [16.8-17.5] in sMIP_1.25mm, for 8mm [17.2-18.3] in fMIP_2.5mm and [17.8-18.4] in sMIP_1.25mm, and for 10mm [19-19.9] in fMIP_2.5mm and [19.4-20] in sMIP_1.25mm (p≥ 0.005), respectively. CONCLUSION: The Quasar Programmable Respiratory Motion Phantom accurately replicated varied breathing patterns and tumor motions. Comprehensive analysis was facilitated through detailed manual segmentation of Internal Target Volumes and Internal Gross Target Volumes.


Asunto(s)
Estudios de Factibilidad , Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Fantasmas de Imagen , Respiración , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos
16.
Int J Med Robot ; 20(3): e2647, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38804195

RESUMEN

BACKGROUND: This study presents the development of a backpropagation neural network-based respiratory motion modelling method (BP-RMM) for precisely tracking arbitrary points within lung tissue throughout free respiration, encompassing deep inspiration and expiration phases. METHODS: Internal and external respiratory data from four-dimensional computed tomography (4DCT) are processed using various artificial intelligence algorithms. Data augmentation through polynomial interpolation is employed to enhance dataset robustness. A BP neural network is then constructed to comprehensively track lung tissue movement. RESULTS: The BP-RMM demonstrates promising accuracy. In cases from the public 4DCT dataset, the average target registration error (TRE) between authentic deep respiration phases and those forecasted by BP-RMM for 75 marked points is 1.819 mm. Notably, TRE for normal respiration phases is significantly lower, with a minimum error of 0.511 mm. CONCLUSIONS: The proposed method is validated for its high accuracy and robustness, establishing it as a promising tool for surgical navigation within the lung.


Asunto(s)
Algoritmos , Tomografía Computarizada Cuatridimensional , Pulmón , Redes Neurales de la Computación , Respiración , Humanos , Pulmón/diagnóstico por imagen , Pulmón/fisiología , Tomografía Computarizada Cuatridimensional/métodos , Movimiento , Reproducibilidad de los Resultados , Inteligencia Artificial , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física)
17.
Int J Cardiol ; 410: 132219, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38815674

RESUMEN

BACKGROUND: The rapid increase in the number of transcatheter aortic valve replacement (TAVR) procedures in China and worldwide has led to growing attention to hypoattenuating leaflet thickening (HALT) detected during follow-up by 4D-CT. It's reported that HALT may impact the durability of prosthetic valve. Early identification of these patients and timely deployment of anticoagulant therapy are therefore particularly important. METHODS: We retrospectively recruited 234 consecutive patients who underwent TAVR procedure in Fuwai Hospital. We collected clinical information and extracted morphological characteristics parameters of the transcatheter heart valve (THV) post TAVR procedure from 4D-CT. LASSO analysis was conducted to select important features. Three models were constructed, encapsulating clinical factors (Model 1), morphological characteristics parameters (Model 2), and all together (Model 3), to identify patients with HALT. Receiver operating characteristic (ROC) curves and decision curve analysis (DCA) were plotted to evaluate the discriminatory ability of models. A nomogram for HALT was developed and verified by bootstrap resampling. RESULTS: In our study patients, Model 3 (AUC = 0.738) showed higher recognition effectiveness compared to Model 1 (AUC = 0.674, p = 0.032) and Model 2 (AUC = 0.675, p = 0.021). Internal bootstrap validation also showed that Model 3 had a statistical power similar to that of the initial stepwise model (AUC = 0.723 95%CI: 0.661-0.786). Overall, Model 3 was rated best for the identification of HALT in TAVR patients. CONCLUSION: A comprehensive predictive model combining patient clinical factors with CT-based morphology parameters has superior efficacy in predicting the occurrence of HALT in TAVR patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Tomografía Computarizada Cuatridimensional , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios Transversales , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Tomografía Computarizada Cuatridimensional/métodos , Valor Predictivo de las Pruebas , Prótesis Valvulares Cardíacas , Estudios de Seguimiento
18.
World Neurosurg ; 187: e798-e806, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38705268

RESUMEN

BACKGROUND: There are cases of superficial siderosis (SS) with spinal ventral fluid-filled collection in the spinal canal. In our previous study, the balanced steady-state free precession sequence magnetic resonance imaging is useful in identifying the location of dural defects. However, because of its narrow scan area and long scan time, it cannot easily detect the defect location in some patients with small dural defect. In this study, we applied 4-dimensional (4D) dynamic computed tomography (CT) imaging, including time-axis imaging, to myelography using the latest CT imaging equipment, which can perform short-time continuous imaging, to identify the dural defect site. METHODS: Twenty SS patients with ventral fluid-filled collection in the spinal canal (9 males, 11 females; mean age 61.6 years) underwent 4D dynamic CT myelography. A 192-row helical CT (SOMATOM Force, SIEMENS, Munich, Germany) with high-speed scanning capability was used to obtain 9-11 scans per minute at low dose while passing contrast medium into the subarachnoid space. Then, contrast leakage sites were identified. RESULTS: The contrast leakage sites could be identified in all 20 cases: C7/Th1, 2 cases; Th1/2, 5 cases; Th2/3, 9 cases; Th3/4, 1 case; Th5/6, 1 case; Th7/8, 1 case; and Th8/9, 1 case. Eighteen cases underwent surgical operation, and actual dural defects were confirmed at the contrast leakage sites. The mean ± standard deviation of leakage time from contrast agent injection was 19.0 ± 9.2 s. CONCLUSIONS: The 4D dynamic CT myelography can be used to reliably identify the location of spinal fluid leakage. In SS cases, dural defects could be visualized in an average of 19 seconds.


Asunto(s)
Duramadre , Mielografía , Siderosis , Humanos , Masculino , Femenino , Persona de Mediana Edad , Duramadre/diagnóstico por imagen , Mielografía/métodos , Anciano , Siderosis/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Adulto , Anciano de 80 o más Años
19.
Med Phys ; 51(7): 4622-4634, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38753583

RESUMEN

BACKGROUND: Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. PURPOSE: A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA). METHODS: Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS). RESULTS: For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. CONCLUSIONS: A detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.


Asunto(s)
Corazón , Fantasmas de Imagen , Dosis de Radiación , Relación Señal-Ruido , Humanos , Corazón/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Procesamiento de Imagen Asistido por Computador/métodos
20.
Clin Radiol ; 79(8): e1040-e1048, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38797610

RESUMEN

AIM: Early diagnosis of scapholunate ligament (SLL) injuries is crucial to prevent progression to debilitating osteoarthritis. Four-Dimensional Computed Tomography (4DCT) is a promising dynamic imaging modality for assessing such injuries. Capitalizing on the known correlation between SLL injuries and an increased scapholunate distance (SLD), this study aims to develop a fully automatic approach to evaluate the SLD continuously during wrist motion and to apply it to a dataset of healthy wrists to establish reference values. MATERIALS AND METHODS: 50 healthy wrists were analysed in this study. All subjects performed radioulnar deviation (RUD), flexion-extension (FE), and clenching fist (CF) movements during 4DCT acquisition. A novel, automatic method was developed to continuously compute the SLD at five distinct locations within the scapholunate joint, encompassing a centre, volar, dorsal, proximal, and distal measurement. RESULTS: The developed algorithm successfully processed datasets from all subjects. Our results showed that the SLD remained below 2 mm and exhibited minimal changes (median ranges between 0.3 mm and 0.65 mm) during RUD and CF at all measured locations. During FE, the volar and dorsal SLD changed significantly, with median ranges of 0.90 and 1.27 mm, respectively. CONCLUSION: This study establishes a unique database of normal SLD values in healthy wrists during wrist motion. Our results indicate that, aside from RUD and CF, FE may also be important in assessing wrist kinematics. Given the labour-intensive and time-consuming nature of manual analysis of 4DCT images, the introduction of this automated algorithm enhances the clinical utility of 4DCT in diagnosing dynamic wrist injuries.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Hueso Semilunar , Hueso Escafoides , Articulación de la Muñeca , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Masculino , Femenino , Adulto , Articulación de la Muñeca/diagnóstico por imagen , Valores de Referencia , Hueso Escafoides/diagnóstico por imagen , Hueso Semilunar/diagnóstico por imagen , Rango del Movimiento Articular/fisiología , Ligamentos Articulares/diagnóstico por imagen , Persona de Mediana Edad , Voluntarios Sanos , Algoritmos , Adulto Joven