1.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38761069

RESUMEN

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Asunto(s)
Estenosis de la Válvula Aórtica , Índice de Severidad de la Enfermedad , Choque Cardiogénico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Choque Cardiogénico/terapia , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano de 80 o más Años , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Riesgo , Factores de Tiempo , Incidencia
2.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577939

RESUMEN

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Factores de Tiempo , Anciano , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Recuperación de la Función , Hemodinámica , Medición de Riesgo
3.
Circ Cardiovasc Interv ; 17(5): e013608, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38529637

RESUMEN

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Masculino , Femenino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Medición de Riesgo , Estudios Retrospectivos , Puntaje de Propensión , Recuperación de la Función , Valvuloplastia con Balón/efectos adversos , Hemodinámica
4.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38545668

RESUMEN

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Asunto(s)
Valvuloplastia con Balón , Falla de Equipo , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/instrumentación , Catéteres Cardíacos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
5.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38456883

RESUMEN

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Hemodinámica , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
6.
Am Heart J ; 270: 13-22, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38253304

RESUMEN

BACKGROUND: Safety and feasibility of transcatheter aortic valve replacement (TAVR) without balloon aortic valvuloplasty (BAV) using the SAPIEN 3 balloon-expandable device has been previously demonstrated. The impact on long-term valve hemodynamic performances and outcomes remains however unknown. We evaluate long-term clinical and hemodynamic results according to the implant strategy (direct TAVR vs BAV pre-TAVR) in patients included in the DIRECTAVI randomized trial (NCT02729519). METHODS: Clinical and echocardiographic follow-up until January 2023 was performed for all patients included in the DIRECTAVI trial since 2016 (n = 228). The primary endpoint was incidence of moderate/severe hemodynamic valve deterioration (HVD), according to the Valve Academic Research defined Consortium-3 criteria (increase in mean gradient ≥10 mmHg resulting in a final mean gradient ≥20 mmHg, or new/worsening aortic regurgitation of 1 grade resulting in ≥ moderate aortic regurgitation). RESULTS: Median follow-up was 3.8 (2.2-4.7) years. Mean age at follow-up was 87 ± 6.7 years. No difference in incidence of HVD in the direct implantation group compared to the BAV group was found (incidence of 1.97 per 100 person-years and 1.45 per 100 person-years, respectively, P = 0.6). Prevalence of predicted prothesis-patient mismatch was low (n = 13 [11.4%] in the direct TAVR group vs n = 15 [13.2%] in BAV group) and similar between both groups (P = .7). Major outcomes including death, stroke, hospitalization for heart failure and pacemaker implantation were similar between both groups, (P = .4, P = .7, P = .3, and P = .3 respectively). CONCLUSION: Direct implantation of the balloon-expandable device in TAVR was not associated with an increased risk of moderate/severe HVD or major outcomes up to 6-year follow-up. These results guarantee wide use of direct balloon-expandable valve implantation, when feasible. CLINICAL TRIALS REGISTRATION NUMBER: NCT05140317.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios de Seguimiento , Insuficiencia de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Tiempo , Diseño de Prótesis , Valvuloplastia con Balón/efectos adversos
9.
Catheter Cardiovasc Interv ; 102(6): 1101-1104, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855219

RESUMEN

Balloon aortic valvuloplasty (BAV) is preferred by most centers over surgery for the treatment of congenital valve stenosis, due to its less invasive nature and faster recovery time. A variety of techniques have been employed to induce a transient cardiac standstill and reduce longitudinal balloon displacement during valve dilatation. Rapid right ventricular (RV) pacing is an effective method to stabilize the balloon during aortic valvuloplasty and it is regularly used in older children and adults. Despite the evidence of its feasibility and efficacy, its use in neonates and infants is still not widespread globally as it is associated with certain drawbacks in this population. We report the use of a new technique to achieve balloon stabilization during BAV in neonates and infants. Four patients with severe congenital aortic valve stenosis were treated with percutaneous BAV using rapid transesophageal atrial pacing. Rapid atrial pacing was performed in asynchronous modality at a rate which resulted in a drop of the systemic arterial pressure by 50%. The balloon was inflated only after the set pacing rate was reached. The pacing was continued until the balloon was completely deflated. No ventricular arrhythmia occurred. Fluoroscopy time was not influenced by transesophageal pacing. Mild aortic regurgitation developed in only one case. Rapid transesophageal atrial pacing was safe and allowed a significant relief of left ventricular obstruction while minimizing aortic regurgitation. Compared to RV pacing, it does not require additional vascular access. Moreover, transesophageal pacing is not at risk of cardiac or vascular perforation and ventricular arrhythmias.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Fibrilación Atrial , Valvuloplastia con Balón , Niño , Recién Nacido , Humanos , Lactante , Resultado del Tratamiento , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
10.
Interv Cardiol Clin ; 12(4): 539-554, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37673498

RESUMEN

Percutaneous structural interventions have a major impact on the morbidity, mortality, and quality of life of patients by providing a lower-risk alternative to cardiac surgery. However, renal disease has a significant impact on outcomes of these interventions. This review explores the incidence, outcomes, pathophysiology, and preventative measures of acute kidney injury and chronic kidney disease on transcatheter aortic valve replacement, transcatheter mitral valve repair, and percutaneous balloon mitral valvuloplasty. Given the expanding indications for percutaneous structural interventions, further research is needed to identify ideal patients with chronic kidney disease or end-stage renal disease who would benefit from intervention.


Asunto(s)
Lesión Renal Aguda , Valvuloplastia con Balón , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/fisiopatología , Lesión Renal Aguda/prevención & control , Lesión Renal Aguda/cirugía , Valvuloplastia con Balón/efectos adversos , Incidencia , Válvula Mitral/cirugía , Insuficiencia Renal Crónica/epidemiología , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/prevención & control , Insuficiencia Renal Crónica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Medición de Riesgo
11.
Curr Probl Cardiol ; 48(12): 102021, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37544629

RESUMEN

Echocardiography is an important diagnostic imaging modality in recognizing rheumatic heart disease, a chronic sequelae of acute rheumatic fever. Left-sided heart valves, especially the mitral valve is typically affected, with stenosis or regurgitation as a consequence. Although assessment of valve area by 2D planimetry is the reference method for mitral stenosis severity, 3D planimetry provides more accurate measurement and diagnostic value. Careful selection of patients in terms of echocardiographic criteria is essential to ensure safety and success of the intervention and better long-term outcomes. Several echocardiographic scores based upon mitral valve mobility, thickening, calcification, and subvalvular thickening are developed to assess mitral valve anatomy and the feasibility of percutaneous mitral commissurotomy. 3D transesophageal echocardiography (TEE) provides detailed information of the mitral anatomy (commissural fusions, and subvalvular apparatus) before intervention. In addition, 3D TEE planimetry provides a more accurate measurement of the valve area compared with 2D echocardiography. Generally, huge annular calcification and lack of commissural fusion are unfavorable echocardiographic markers that increase the risk of complications and preclude the feasibility of percutaneous balloon mitral valvuloplasty. More contemporary prospective echocardiography research studies on patients with RHD from low- and middle-income countries are needed.


Asunto(s)
Valvuloplastia con Balón , Calcinosis , Estenosis de la Válvula Mitral , Cardiopatía Reumática , Humanos , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/terapia , Estudios Prospectivos , Ecocardiografía/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/terapia , Calcinosis/diagnóstico por imagen , Calcinosis/terapia , Valvuloplastia con Balón/efectos adversos
12.
BMC Pediatr ; 23(1): 337, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37400786

RESUMEN

BACKGROUND: Pulmonary stenosis (PS) is a congenital heart diseases (CHDs) with a spectrum of stenosis. Monochorionic (MC) twins are at increased risk of CHDs, especially acquired CHDs in twin-twin transfusion syndrome (TTTS). PS/Pulmonary atresia (PA) is a rare coincidence with TTTS. MC twin pregnancies have increased in last decades due to increasing in maternal age and extensive use of assisted reproductive technologies. Therefore, attention to this group is important for heart abnormalities, especially in twins with TTTS. Multiple cardiac abnormalities in MC twins with TTTS are to be expected due to cardiac hemodynamic changes and may be eliminated by Fetoscopic laser photocoagulation treatment. Prenatal diagnosis of PS is necessary given the importance of treatment after birth. CASE PRESENTATION: We here present a case of coexistence of TTTS with PS in a growth restricted recipient twin who successfully treated with balloon pulmonary valvuloplasty in neonatal period. Also, we detected infundibular PS after valvuloplasty that treated with medical therapy (propranolol). CONCLUSIONS: It is important to detect acquired cardiac abnormalities in MC twins with TTTS, and follow them up after birth to determine the need of intervention in neonatal period.


Asunto(s)
Valvuloplastia con Balón , Transfusión Feto-Fetal , Cardiopatías Congénitas , Estenosis de la Válvula Pulmonar , Embarazo , Recién Nacido , Femenino , Humanos , Transfusión Feto-Fetal/complicaciones , Transfusión Feto-Fetal/diagnóstico , Transfusión Feto-Fetal/terapia , Valvuloplastia con Balón/efectos adversos , Gemelos , Estenosis de la Válvula Pulmonar/etiología , Estenosis de la Válvula Pulmonar/cirugía , Parto , Cardiopatías Congénitas/complicaciones
13.
J Am Heart Assoc ; 12(12): e028837, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37301755

RESUMEN

Background The goal of this study was to evaluate long-term results of percutaneous balloon valvuloplasty (BVPL) used exclusively for initial management of congenital aortic stenosis in children. Methods and Results A total of 409 consecutive pediatric patients (134 newborns, 275 older patients) who underwent BVPL as initial treatment of aortic stenosis in a single nationwide pediatric center were subjected to a retrospective follow-up study. The resulting follow-up time reached a median of 18.5 (interquartile range, 12.2-25.1) years. Successful BVPL was defined by residual Doppler gradient <70/40 (systolic/mean) mm Hg. The primary end point was death; secondary end points included any valve reintervention, balloon revalvuloplasty, any aortic valve surgery, and aortic valve replacement, respectively. BVPL effectively reduced the peak and mean gradient both immediately and at the latest follow-up (P<0.001). There was significant procedure-related progression of aortic insufficiency (P<0.001). Higher aortic annulus z score was predictive for severe aortic regurgitation (P<0.05) and lower z score for insufficient gradient reduction (P<0.05). The actuarial probability of survival/survival free from any valve reintervention was 89.9%/59.9%, 85.9%/35.2%, and 82.0%/26.7% at 10, 20, and 30 years after first BVPL, respectively. Left ventricular dysfunction or arterial duct dependency as the indication for BVPL was predictive of both worse survival and survival free from any reintervention (P<0.001). Lower aortic annulus z score and lower balloon-to-annulus ratio were predictive of a need for revalvuloplasty (P<0.001). Conclusions Percutaneous BVPL provides good initial palliation. In patients with hypoplastic annuli and left ventricular or mitral valve comorbidity, the results are less favorable.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Cardiopatías Congénitas , Niño , Humanos , Recién Nacido , Lactante , Estudios de Seguimiento , Valvuloplastia con Balón/efectos adversos , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/congénito , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Resultado del Tratamiento
14.
Cardiovasc Revasc Med ; 55: 1-7, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37208215

RESUMEN

BACKGROUND: Severe Aortic stenosis (AS) complicated by cardiogenic shock (CS) represents a grave clinical condition with limited treatment options. Evidence from small observation studies favors that Transcatheter Aortic Valve Replacement (TAVR) might be a feasible option in these patients in contrast to emergent Balloon Aortic Valvuloplasty (BAV) which is associated with very high short and long-term mortality. METHODS: 11,405 hospitalizations with severe AS complicated by CS between 2016 and 2020 were identified using the National Inpatient Sample (NIS) Database, and patients were then stratified according to whether they received TAVR or BAV. Propensity-score matching was used to account for differences in the baseline characteristics. Primary and secondary outcomes were then compared between 3485 hospitalizations in direct TAVR group and with 3485 matched hospitalizations in the BAV group. The primary outcome was a composite of all-cause in-hospital death, acute cerebrovascular accident (CVA), and myocardial infarction (MI). Secondary outcomes and safety outcomes were also compared between the two groups. RESULTS: TAVR was associated with fewer primary outcomes events as compared to BAV {36.8 % vs 56.8 %, aOR (95%CI) = 0.38(0.30-0.47)}, due to fewer all-cause in-hospital deaths {17.8 % vs 38.9 %, aOR (95%CI) =0.34 (0.26-0.43)} and MI {12.3 % vs 32.4 %, aOR (95%CI) = 0.29 (0.22-0.39)}. TAVR was associated with higher rates of acute CVA {6.17 % vs 3.44 %, aOR (95%CI) = 1.84 (1.08-3.21)} and pacemaker implantation post procedure {11.9 % vs 6.03 %, aOR (95%CI) = 2.10 (1.41-3.18)}. CONCLUSION: Direct TAVR in shock and severe Aortic stenosis is a better strategy than rescue Balloon aortic valvotomy.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Infarto del Miocardio , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Pacientes Internos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Mortalidad Hospitalaria , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Valvuloplastia con Balón/efectos adversos , Infarto del Miocardio/cirugía
16.
Heart Vessels ; 38(7): 957-963, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36781429

RESUMEN

Management of high-risk patients with severe aortic stenosis (AS) is a challenging issue. The prognosis of patients with AS presenting with therapy-refractory pulmonary edema (RPE) or cardiogenic shock (CS) remains poor. The purpose of this study was to assess the 30-day mortality of rescue percutaneous balloon aortic valvuloplasty (PBAV) in AS patients presenting with RPE or CS in a community-based hospital without on-site heart surgery. From January 2016 to February 2019, we identified consecutively admitted patients with CS or RPE related to severe AS who underwent emergent PBAV. The primary end point was 30-day mortality. Secondary end points included procedural adverse events according to the Valve Academic Research Consortium (VARC)-2 criteria and predictive factors of the primary end point. We identified 51 patients with either CS (n = 22) or RPE (n = 29). All PBAV procedures were successful with a significant reduction in peak-to-peak gradient (median, [IQR] from 40 [27] mmHg to 15 [20] mmHg, p < 0.001). No procedural deaths occurred, while adverse events included stroke (4%), minor vascular complications (6%), minor (4%) and major bleedings (4%), and no life-threatening bleeding. Overall, 15 deaths (29%) were noted at 30 days after PBAV, while 53% of the surviving patients were successfully bridged to transcatheter aortic valve implantation (TAVI). 30-day mortality was significantly higher in the CS group compared to the RPE (n = 10 (45%) vs n = 5 (7%), p = 0.029), and was significantly associated with the presence of acute kidney injury (OR 9.09, 95% CI 2.13-38.77, p = 0.003) and elevated pulmonary artery systolic pressure (OR 1.06, 95% CI 1.0-1.12, p = 0.047). Rescue PBAV in patients with severe AS presenting with RPE or CS is a feasible and effective therapeutic option, even in a community-based hospital without on-site heart surgery. Rescue PBAV resulted in 30-day survival of more than 70%, with more than half of the surviving patients having been successfully bridged to TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Pronóstico , Choque Cardiogénico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
17.
Kardiol Pol ; 81(4): 366-372, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36648223

RESUMEN

BACKGROUND: Long-term outcomes of balloon aortic valvuloplasty (BAV) in patients with severe symptomatic aortic stenosis (AS) are poor, and this procedure needs to be repeated in selected cases. AIMS: We aimed to investigate the safety and efficacy of repeated BAV (reBAV). METHODS: We included consecutive patients who underwent reBAV in three Polish centers between 2010 and 2019. Baseline clinical, echocardiographic, procedural, and outcome data were analyzed. RESULTS: Thirty-five patients (median age 81.5 years, 57.1% women) who underwent reBAV were enrolled. In 42.9% of the patients, index BAV was considered a palliative treatment, and in 54.3% a bridge to definitive treatment. Index BAV decreased peak aortic valve gradient (pAVG) from a median of 78.0 mm Hg to 46.0 mm Hg (P <0.001). After a mean of 255.8 days, reBAV was performed. In most cases (71.4%), the reason for reBAV was the worsening of heart failure symptoms and in 54.3% of patients, reBAV was still considered a palliative option. A decrease in pAVG max from a median of 73.0 mm Hg to 45.0 mm Hg (P <0.001), comparable to index BAV, was observed. The frequency of complications were numerically higher for repeated procedures. During the median (IQR) follow-up of 403.0 (152.0-787.0) days from the index procedure, 80.0% of the patients died. CONCLUSIONS: Acute hemodynamic results of reBAV are comparable to those achieved during index BAV. However, reBAV may carry an increased risk of complications. Moreover, mortality is high due to unfavorable risk profiles or delays in receiving definitive therapy.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/métodos , Valvuloplastia con Balón/estadística & datos numéricos , Insuficiencia Cardíaca , Polonia , Resultado del Tratamiento
18.
Vasc Health Risk Manag ; 19: 13-20, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36687312

RESUMEN

Background: Percutaneous balloon mitral valvuloplasty (PBMV) is considered the most suitable option for managing symptomatic severe mitral valve stenosis (MS) during pregnancy with favorable anatomy. We do not know the best time to perform PBMV during pregnancy to achieve the best maternal and fetal outcomes. Therefore, we conducted this study to clarify the best procedure timing. Methods: This prospective, observational, single-center study involved 44 pregnant patients suffering from symptomatic MS who underwent PBMV from May 2017 to May 2020. A detailed history is taken, full clinical examination, laboratory assessment, 2 D echocardiography, and follow-up during the hospital stay and monthly until labor. Results: We found that the mean mitral valve area (MVA) had significantly increased from 1.12 ± 0.24 to 2.09 ± 0.46 cm2 (P < 0.001). The mean pressure gradient across the mitral valve reduced from 17.22 ± 5.55 to 8.94 ± 3.75 mmHg (P < 0.001). The procedures were successful in 91% of the patients. Regarding obstetric outcomes, the incidence of preterm labor, fetal death, and composite adverse outcomes was significantly lower in patients who had the procedure during the second trimester than those who had the procedure during the third trimester. All preterm deliveries and intrauterine fetal deaths occurred at least 21 days after PBMV. The patients showed a statistically significant improvement in NYHA functional classification. Conclusion: We can conclude that PBMV performed in pregnant patients is an effective and safe treatment modality, and we observed better obstetric outcomes achieved with early intervention during the second trimester.


Asunto(s)
Valvuloplastia con Balón , Estenosis de la Válvula Mitral , Embarazo , Femenino , Recién Nacido , Humanos , Estudios Prospectivos , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/métodos , Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/terapia , Ecocardiografía/métodos