Resistência de união de primers/silanos em superfície de cêramica vítrea / Novel silane/primers bond strength in glass ceramics surface
J. Health Biol. Sci. (Online)
; 8(1): 1-7, 20200101. ilus
Article
en Pt
| LILACS
| ID: biblio-1118401
Biblioteca responsable:
BR1780.2
RESUMO
Objetivo:
investigar a resistência de união por cisalhamento de diferentes soluções contendo silano e primer na superfície de Dissilicato de Lítio (IPS e.maxCAD, Ivoclar-Vivadent).Metodologia:
78 blocos cerâmicos foram incluídos em resina acrílica, polidos e lavados em ultra-som por 10 minutos. Os espécimes foram divididos em dois grupos de acordo com tratamento de superfície Superfície Polida (PS); Ácido Hidro-Fluorídrico 9,5% - 20s (HF). Cada grupo foi dividido em três subgrupos (n = 13), de acordo com o tipo de silano silano tradicional (Porcelain Prime, Inc. Bisco); mistura de silano e resina (KerrSilane, Kerr); mistura de silano e adesivo universal (Single-bond Universal, 3M Espe). Os espécimes foram montados em um dispositivo padrão para teste de cisalhamento (UltradentBonding Assembly), cimentados com cimento resinoso dual (Duolink Universal™, Bisco Inc.) e foto-polimerizados por 20s. As amostras foram testadas após 24 horas e 90 dias de armazenamento em água destilada a 47°C. Os dados foram analisados por 2-Way Anova e Teste de Tukey (α=5%).Resultados:
em geral, os valores de resistência adesiva do silano tradicional foram, estatisticamente, mais elevados do que os outros tipos de silanos. O armazenamento afetou, significativamente, a força de adesão para a maioria dos grupos (p <0,001). O grupo PS apresentou menores valores de resistência adesiva, independentemente da variável (silano vs armazenamento).Conclusões:
adequada resistência adesiva pode ser obtida com silanos tradicionais após o pré-tratamento de superfície com ácido HFABSTRACT
Objective:
To investigate the efficacy of "new silanes / primer" in the Lithium Disilicate surface (IPS e.maxCAD, IvoclarVivadent-) by means of adhesive shear bond strength test.Methodology:
A total of 78 ceramic blocks were embedded in acrylic resin, polished and washed in ultrasound for 10 minutes. The specimens were divided into two groups according to surface treatment Polished Surface (PS); Hydrofluoric acid 9,5% - 20s (HF). Each group was divided into three sub-groups (n = 13) according to the type of silane used traditional silane (Porcelain Prime Bisco, Inc.); mixture of silane and resin (Kerr Silane, Kerr); mixture of silane and universal adhesive (Single-bond Universal, 3M Espe). The specimens were mounted on a standard device for shear test (Ultradent Bonding Assembly), cemented with dual resin cement (Duolink Universal ™, Bisco Inc.) and photo-polymerised for 20s. The samples were tested after 24 hours and 90 days of storage in distilled water at 47°C. Data were analyzed by 2-way ANOVA and Tukey Test (α = 5%).Results:
In general, the adhesive strength value of traditional silanewas significantly higher than other types of silanes. The storage significantly affects the bond strength (bond) for most groups (p <0.001). The PS group showed lower bond strength values, independent of the variable (silane vs. storage).Conclusions:
Suitable adhesive strength can be obtained with traditional silanes, combined with the pre-treatment surface with HF acid.Palabras clave
Texto completo:
1
Base de datos:
LILACS
Asunto principal:
Silanos
Idioma:
Pt
Revista:
J. Health Biol. Sci. (Online)
/
Journal of Health & Biological Sciences (Impresso)
/
Journal of Health & Biological Sciences (Online)
Asunto de la revista:
Cincias da Sa£de
/
Disciplinas das Cincias Biol¢gicas
Año:
2020
Tipo del documento:
Article