Your browser doesn't support javascript.
loading
A strategy for the mapping of N-glycans by high-pH anion-exchange chromatography with pulsed amperometric detection.
Hermentin, P; Witzel, R; Vliegenthart, J F; Kamerling, J P; Nimtz, M; Conradt, H S.
Afiliación
  • Hermentin P; Research Laboratories of Behringwerke AG, Marburg, Germany.
Anal Biochem ; 203(2): 281-9, 1992 Jun.
Article en En | MEDLINE | ID: mdl-1416024
ABSTRACT
We have evaluated the high-pH anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) with respect to its suitability to establish a carbohydrate mapping database that would enable carbohydrate structural analysis by mere comparison of retention times. The suitability of HPAE-PAD for carbohydrate structural analysis was ascertained by validation experiments. The retention times of distinct N-glycans, prepared and measured on different days, were shown to be highly reproducible, with a coefficient of variation (CV) of less than 0.5%, requiring less than 100 pmol of N-glycan per injection for reliable measurements. Including appropriate internal chromatographic standards, such as (Neu5Ac)1, (Neu5Ac)2, (Neu5Ac)3, and Neu5Gc, the HPAE-PAD method fulfills the analytical requirements with respect to accuracy, precision, reproducibility, and sensitivity. The N-glycan mapping database was established, using two optimized linear gradients "S" and "A" for sialylated and asialo N-glycans, respectively. Approximately 100 different N-glycans of known structure, which have thus far been measured and characterized, have entered our Lotus 1-2-3 mapping database. The efficiency of the database for structural determinations was tested, using the N-linked carbohydrates isolated from rhuEPO, expressed in BHK cells. Nine different sialylated N-glycans of rhuEPO (BHK) could be assigned with a deviation of less than +/- 0.5%, using gradient S, and six of the eight asialo N-glycans of rhuEPO (BHK) detected with gradient A could be assigned with an accuracy of less than +/- 1%, three of them even with an accuracy of less than 0.1%, providing the reliability of the established HPAE-PAD mapping database.
Asunto(s)
Buscar en Google
Base de datos: MEDLINE Asunto principal: Polisacáridos Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Biochem Año: 1992 Tipo del documento: Article
Buscar en Google
Base de datos: MEDLINE Asunto principal: Polisacáridos Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Biochem Año: 1992 Tipo del documento: Article