Tissue Doppler imaging and echo-Doppler findings associated with a mitral valve stenosis with an immobile posterior valve leaflet in a bull terrier.
J Vet Med A Physiol Pathol Clin Med
; 51(3): 138-42, 2004 Apr.
Article
en En
| MEDLINE
| ID: mdl-15214855
ABSTRACT
A mitral valve stenosis was diagnosed in a 2-year-old female Bull Terrier by use of two-dimensional (2-D) and M-mode echocardiography, colour-flow imaging and spectral Doppler examinations. Tissue Doppler Imaging was also performed to assess the segmental radial myocardial motion. The mitral valve stenosis was characterized by a decreased mitral orifice area/left ventricle area ratio (0.14), an increased early diastolic flow velocity (E wave = 1.9 m/s), a prolonged pressure half-time (106 ms) and a decreased E-F slope (4.5 cm/s) on pulsed-wave Doppler examination. This mitral stenosis was associated with an immobile posterior leaflet, as seen on 2-D and M-mode echocardiography. Immobility of the posterior mitral leaflet is considered to be a rare finding in humans and, to our knowledge, has not been precisely documented in dogs with mitral valve stenosis.