BioGlue and Dermabond save time, leak less, and are not mechanically inferior to two-layer and modified one-layer vasovasostomy.
Saunders, Marnie M; Baxter, Z Chad; Abou-Elella, Ashraf; Kunselman, Allen R; Trussell, J C.
Afiliación
  • Saunders MM; Center for Biomedical Engineering, University of Kentucky, Wenner-Gren Research Laboratory, Lexington, Kentucky, USA.
Fertil Steril ; 91(2): 560-5, 2009 Feb.
Article en En | MEDLINE | ID: mdl-18304547
ABSTRACT

OBJECTIVE:

To compare operative time, patency, and integrity of glue-assisted versus suture-only vasovasostomies.

DESIGN:

A Medline search revealed no vasovasostomy studies testing tissue adhesives other than fibrin. We compare glue-reinforced to suture-only vasovasostomies.

SETTING:

An academic medical center. PATIENT(S) None. INTERVENTION(S) Using bull vas deferens, we performed [1] two-layer anastomoses, [2] modified one-layer anatomoses, and [3] Bioglue, Dermabond, or CoSeal-reinforced anastomoses supported by three transmural sutures. MAIN OUTCOME MEASURE(S) Operative times were recorded, patency verified, and microscopic dissection performed to rule out luminal glue intravasation. Destructive mechanical testing was then completed with statistical comparison of load to failure, displacement to failure, and linear stiffness. RESULT(S) Operative time was greatest for two-layer anastomoses and significantly reduced for all three glue-reinforced three-suture anastomoses. All techniques were patent and free of glue intravasation. BioGlue and Dermabond demonstrated greater integrity than all other techniques. Mechanically, BioGlue and Dermabond were superior to both the unreinforced three stitch and CoSeal groups and were capable of resisting higher loads before failure. CONCLUSION(S) Glue-reinforced anastomoses are significantly less time consuming than traditional techniques. BioGlue and Dermabond have greater mechanical integrity and may be superior to both CoSeal and the sutured techniques.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Adhesivos Tisulares / Conducto Deferente / Vasovasostomía / Proteínas / Técnicas de Sutura / Cianoacrilatos Idioma: En Revista: Fertil Steril Año: 2009 Tipo del documento: Article