Your browser doesn't support javascript.
loading
Determination of a highly selective mixed-affinity sigma receptor ligand, in rat plasma by ultra performance liquid chromatography mass spectrometry and its application to a pharmacokinetic study.
Jamalapuram, Seshulatha; Vuppala, Pradeep K; Mesangeau, Christophe; McCurdy, Christopher R; Avery, Bonnie A.
Afiliación
  • Jamalapuram S; Department of Pharmaceutics, School of Pharmacy, The University of Mississippi, University, MS 38677, USA.
Article en En | MEDLINE | ID: mdl-22406103
A selective, rapid and sensitive ultra performance liquid chromatography mass spectrometry (UPLC/MS) method was developed and validated to quantitate a highly selective mixed-affinity sigma receptor ligand, CM156 (3-(4-(4-cyclohexylpiperazin-1-yl)butyl)benzo[d] thiazole-2(3H)-thione), in rat plasma. CM156 and the internal standard (aripiprazole) were extracted from plasma samples by a single step liquid-liquid extraction using chloroform. The analysis was carried out on an ACQUITY UPLC™ BEH HILIC column (1.7 µm, 2.1 mm×50 mm) with isocratic elution at flow rate of 0.2 mL/min using 10mM ammonium formate in 0.1% formic acid and acetonitrile (10:90) as the mobile phase. The detection of the analyte was performed on a mass spectrometer operated in selected ion recording (SIR) mode with positive electrospray ionization (ESI). The validated analytical method resulted in a run time of 4 min and the retention times observed were 2.6±0.1 and 2.1±0.1 min for CM156 and the IS, respectively. The calibration curve exhibited excellent linearity over a concentration range of 5-4000 ng/mL with the lower limit of quantification of 5 ng/mL. The intra- and inter-day precision values were below 15% and accuracy ranged from -6.5% to 5.0%. The mean recovery of CM156 from plasma was 96.8%. The validated method was applied to a pilot intravenous pharmacokinetic study in rats.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Piperazinas / Compuestos de Azufre / Cromatografía Liquida / Espectrometría de Masa por Ionización de Electrospray Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2012 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Piperazinas / Compuestos de Azufre / Cromatografía Liquida / Espectrometría de Masa por Ionización de Electrospray Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2012 Tipo del documento: Article