Immediately loaded mandibular fixed implant prostheses using the all-on-four protocol: a report of 183 consecutively treated patients with 1 year of function in definitive prostheses.
Galindo, Daniel F; Butura, Caesar C.
Afiliación
  • Galindo DF; Private Practice Limited to Prosthodontics, Phoenix, AZ, USA. galindoprosthodontics@gmail.com
Int J Oral Maxillofac Implants ; 27(3): 628-33, 2012.
Article en En | MEDLINE | ID: mdl-22616057
ABSTRACT

PURPOSE:

The purpose of this study was to evaluate a specific protocol using four implants to support immediately loaded fixed prostheses to restore edentulous and partially edentulous mandibles and report on the outcome after 1 year of function with the definitive prostheses. MATERIALS AND

METHODS:

A retrospective study was conducted of all patients who were treated between June 2008 and December 2010 with fixed prostheses that were loaded immediately after placement of implants. The provisional prostheses were later replaced with computer-aided design/computer-assisted manufacture titanium frames supporting acrylic resin and denture teeth in the definitive prosthesis. All patients were followed for a minimum of 12 months and were assessed for implant survival and prosthetic performance, with descriptive statistics utilized to demonstrate results.

RESULTS:

One hundred eighty-three consecutive patients received immediately loaded axial and tilted implants according to the defined protocol. One implant failed, resulting in a 99.86% implant success rate. There were two catastrophic prosthetic failures (fracture of the titanium framework), for a 98.9% prosthetic success rate. Three patients (1.6%) presented with fracture of a prosthetic mandibular incisor tooth. No prosthetic screw loosening or fractures were seen. Radiographic evaluation revealed no major bone loss around dental implants.

CONCLUSIONS:

Based on this retrospective study, the following conclusions can be drawn (1) this technique appears to provide a highly predictable implant performance; (2) it is necessary to critically evaluate framework design, especially around the connectors for cantilever extensions around the most distal implants; and (3) minor complications related to acrylic resin tooth fracture may be anticipated during the early phases of prosthetic treatment.
Asunto(s)
Buscar en Google
Base de datos: MEDLINE Asunto principal: Diseño de Prótesis Dental / Prótesis Dental de Soporte Implantado / Implantación Dental Endoósea / Dentadura Parcial Fija / Carga Inmediata del Implante Dental / Mandíbula Tipo de estudio: Evaluation_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Int J Oral Maxillofac Implants Asunto de la revista: ODONTOLOGIA Año: 2012 Tipo del documento: Article
Buscar en Google
Base de datos: MEDLINE Asunto principal: Diseño de Prótesis Dental / Prótesis Dental de Soporte Implantado / Implantación Dental Endoósea / Dentadura Parcial Fija / Carga Inmediata del Implante Dental / Mandíbula Tipo de estudio: Evaluation_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Int J Oral Maxillofac Implants Asunto de la revista: ODONTOLOGIA Año: 2012 Tipo del documento: Article