In-line multipoint near-infrared spectroscopy for moisture content quantification during freeze-drying.
Kauppinen, Ari; Toiviainen, Maunu; Korhonen, Ossi; Aaltonen, Jaakko; Järvinen, Kristiina; Paaso, Janne; Juuti, Mikko; Ketolainen, Jarkko.
Afiliación
  • Kauppinen A; School of Pharmacy, Promis Centre, Faculty of Health Sciences, University of Eastern Finland, P.O. Box 1627, FI-70211 Kuopio, Finland. ari.kauppinen@uef.fi
Anal Chem ; 85(4): 2377-84, 2013 Feb 19.
Article en En | MEDLINE | ID: mdl-23351045
ABSTRACT
During the past decade, near-infrared (NIR) spectroscopy has been applied for in-line moisture content quantification during a freeze-drying process. However, NIR has been used as a single-vial technique and thus is not representative of the entire batch. This has been considered as one of the main barriers for NIR spectroscopy becoming widely used in process analytical technology (PAT) for freeze-drying. Clearly it would be essential to monitor samples that reliably represent the whole batch. The present study evaluated multipoint NIR spectroscopy for in-line moisture content quantification during a freeze-drying process. Aqueous sucrose solutions were used as model formulations. NIR data was calibrated to predict the moisture content using partial least-squares (PLS) regression with Karl Fischer titration being used as a reference method. PLS calibrations resulted in root-mean-square error of prediction (RMSEP) values lower than 0.13%. Three noncontact, diffuse reflectance NIR probe heads were positioned on the freeze-dryer shelf to measure the moisture content in a noninvasive manner, through the side of the glass vials. The results showed that the detection of unequal sublimation rates within a freeze-dryer shelf was possible with the multipoint NIR system in use. Furthermore, in-line moisture content quantification was reliable especially toward the end of the process. These findings indicate that the use of multipoint NIR spectroscopy can achieve representative quantification of moisture content and hence a drying end point determination to a desired residual moisture level.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Agua / Espectroscopía Infrarroja Corta / Liofilización Tipo de estudio: Prognostic_studies Idioma: En Revista: Anal Chem Año: 2013 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Agua / Espectroscopía Infrarroja Corta / Liofilización Tipo de estudio: Prognostic_studies Idioma: En Revista: Anal Chem Año: 2013 Tipo del documento: Article