Your browser doesn't support javascript.
loading
Development of an immunochromatographic lateral flow device for rapid diagnosis of Vibrio cholerae O1 serotype Ogawa.
Chen, Weixian; Zhang, Jun; Lu, Gang; Yuan, Zuowei; Wu, Qian; Li, Jingjing; Xu, Guiping; He, An; Zheng, Jian; Zhang, Juan.
Afiliación
  • Chen W; The Clinical Laboratory Center, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Zhang J; Artron BioResearch Inc., Burnaby, British Columbia, Canada.
  • Lu G; Artron BioResearch Inc., Burnaby, British Columbia, Canada.
  • Yuan Z; The Institute for Viral Hepatitis, Key Laboratory of Molecular Biology on Infectious Diseases, Ministry of Education, Chongqing Medical University, Chongqing, China.
  • Wu Q; The Clinical Laboratory Center, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Li J; The Blood Transfusion Department, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Xu G; The Blood Transfusion Department, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • He A; The Institute for Viral Hepatitis, Key Laboratory of Molecular Biology on Infectious Diseases, Ministry of Education, Chongqing Medical University, Chongqing, China.
  • Zheng J; The Institute for Viral Hepatitis, Key Laboratory of Molecular Biology on Infectious Diseases, Ministry of Education, Chongqing Medical University, Chongqing, China.
  • Zhang J; The Blood Transfusion Department, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. Electronic address: jian0102@hotmail.com.
Clin Biochem ; 47(6): 448-54, 2014 Apr.
Article en En | MEDLINE | ID: mdl-24389075
ABSTRACT

OBJECTIVES:

Cholera is an acute malignant infectious disease caused by the bacteria Vibrio cholerae leading to severe dehydrating diarrhea and vomiting, even high rates of mortality in some cases. However, the prevention of the epidemic disease is achievable if proper sanitation practices are followed, provided the accurate and prompt diagnosis of each prevalent serotype in cholera epidemic. The current gold standard of bacterial culture is inadequate for rapid diagnosis. Our aim is to develop an immunochromatographic test format for O1 serotype Ogawa diagnosis and provide the need for better epidemic prevention and early response. DESIGN AND

METHODS:

The monoclonal antibodies were raised in conventional method and subsequently screened for a match pair. A variety of related and unrelated bacteria strains recruited were employed to test their sensitivity, specificity etc. by indirect ELISA. The human fecal samples were used to test the final lateral-flow device product to satisfy the measurement requirement.

RESULTS:

A new monoclonal antibody (McAb) pair, named IXiao3G6 and IXiao1D9, was generated, which is specifically against V. cholerae O1 serotype Ogawa. Additionally, we developed an immunochromatographic lateral flow device (LFD) using this McAb pair for the highly specific and rapid (5 min) detection of Ogawa.

CONCLUSIONS:

Our product has advantages of simplicity and precision, and can benefit the scene and elementary medical institutions.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Reología / Cólera / Cromatografía de Afinidad / Vibrio cholerae O1 Tipo de estudio: Diagnostic_studies Idioma: En Revista: Clin Biochem Año: 2014 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Reología / Cólera / Cromatografía de Afinidad / Vibrio cholerae O1 Tipo de estudio: Diagnostic_studies Idioma: En Revista: Clin Biochem Año: 2014 Tipo del documento: Article