Your browser doesn't support javascript.
loading
Stability of the acrysof toric intraocular lens in combined cataract surgery and transconjunctival sutureless vitrectomy.
Toussaint, Brian W; Appenzeller, Matthew F; Miller, Daniel M; Petersen, Michael R; Foster, Robert E; Osher, Robert H; Snyder, Michael E; Hunt, Christine K; Sisk, Robert A; Riemann, Christopher D.
Afiliación
  • Toussaint BW; Cincinnati Eye Institute and University of Cincinnati Department of Ophthalmology, Cincinnati, Ohio.
Retina ; 35(6): 1065-71, 2015 Jun.
Article en En | MEDLINE | ID: mdl-25763463
ABSTRACT

PURPOSE:

To report the outcomes of combined cataract surgery with toric intraocular lens (IOL) implantation when performed in conjunction with transconjunctival sutureless pars plana vitrectomy.

DESIGN:

Retrospective interventional case series.

PARTICIPANTS:

Consecutive series of 55 eyes of 51 patients from April 2007 to December of 2010.

METHODS:

All eyes underwent combined simultaneous small incision cataract surgery, toric IOL implantation, and transconjunctival sutureless vitrectomy surgery. MAIN OUTCOME

MEASURES:

Postoperative visual acuity, postoperative astigmatism, and rotational stability of the IOL.

RESULTS:

Preoperative best-corrected visual acuity was 0.32 ± 0.15 logMar (Snellen 20/43) and improved to 0.16 ± 0.10 (Snellen 20/29) postoperatively uncorrected (P < 0.01) and to 0.08 ± 0.11 best-corrected (Snellen 20/24) (P < 0.01). Preoperative astigmatism was 1.75 ± 1.0 diopters (D) (range, 0-4.75 D) and improved to 0.5 ± 0.50 D (range, 0-2.5 D) postoperatively (P < 0.01). Final measured postoperative IOL axis deviation from target axis was 4 ± 6° (range, 0-32). Final IOL axis was within 5° of target in 47 (85%) eyes, within 10 degrees of target in 51 (93%) eyes, and was within 15° of target in 52 (95%) eyes.

CONCLUSION:

Toric lens position and axis remained stable after implantation during combined cataract surgery and transconjunctival sutureless vitrectomy.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Vitrectomía / Agudeza Visual / Facoemulsificación / Seudofaquia / Implantación de Lentes Intraoculares / Lentes Intraoculares Idioma: En Revista: Retina Año: 2015 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Vitrectomía / Agudeza Visual / Facoemulsificación / Seudofaquia / Implantación de Lentes Intraoculares / Lentes Intraoculares Idioma: En Revista: Retina Año: 2015 Tipo del documento: Article