Your browser doesn't support javascript.
loading
Nerve conduction block in diabetic rats using high-intensity focused ultrasound for analgesic applications.
Lee, Y-F; Lin, C-C; Cheng, J-S; Chen, G-S.
Afiliación
  • Lee YF; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan, Taiwan.
  • Lin CC; Department of Neurology, National Cheng Kung University Hospital, Tainan, Taiwan.
  • Cheng JS; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan, Taiwan.
  • Chen GS; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan, Taiwan gschen@nhri.org.tw.
Br J Anaesth ; 114(5): 840-6, 2015 May.
Article en En | MEDLINE | ID: mdl-25904608
ABSTRACT

BACKGROUND:

Nerve conduction block using high-intensity focused ultrasound (HIFU) has been conducted with nerves of mixed fibres in normal animal models. This study tested the feasibility and safety of HIFU for sensory nerve conduction block in diabetic neuropathic nerves to determine its potential for pain relief.

METHODS:

Diabetes was induced in Sprague-Dawley rats using streptozotocin, and HIFU at 2.68 MHz was used for the block. This study consisted of two sections, in vitro and in vivo. For the in vitro experiments, the entire contiguous sciatic-sural nerves were obtained. Compound action potentials and sensory action potentials were recorded in the sciatic and sural nerves, respectively. For the in vivo experiments, compound muscle action potentials (CMAPs) were recorded from the gastrocnemius muscles. All data were expressed as median (range).

RESULTS:

The in vitro results showed that HIFU temporarily inhibited sensory action potentials of the control and diabetic rat nerves to 33.9 (8.2) and 14.0 (10.7)% of the baseline values, respectively, whereas the compound action potentials were suppressed to 53.6 (8.4) and 76.2 (7.5)% of baseline, respectively. The in vivo results showed that HIFU acutely blocked CMAPs to 32.9 (12.6) and 19.9 (10.9)% of baseline in control and diabetic rat nerves, respectively. Measurements of CMAPs and histological exanmination were used for indirect assessment of the safety of the HIFU technique.

CONCLUSIONS:

High-intensity focused ultrasound safely and reversibly suppressed nerve conduction in diabetic rat nerves when the stimulation parameters were appropriate. The results suggest that HIFU may have potential to block sensory nerves reversibly and provide peripheral pain relief.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Dolor / Neuropatías Diabéticas / Ultrasonido Enfocado de Alta Intensidad de Ablación / Manejo del Dolor / Bloqueo Nervioso / Conducción Nerviosa Idioma: En Revista: Br J Anaesth Año: 2015 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Dolor / Neuropatías Diabéticas / Ultrasonido Enfocado de Alta Intensidad de Ablación / Manejo del Dolor / Bloqueo Nervioso / Conducción Nerviosa Idioma: En Revista: Br J Anaesth Año: 2015 Tipo del documento: Article