Your browser doesn't support javascript.
loading
Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging.
Zhao, Jinxin; Wang, Yuanyuan; Yu, Jinhua; Guo, Wei; Li, Tianjie; Zheng, Yong-Ping.
Afiliación
  • Zhao J; Department of Electronic Engineering, Fudan University, Shanghai 200433, China; Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region.
  • Wang Y; Department of Electronic Engineering, Fudan University, Shanghai 200433, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai 200433, China. Electronic address: yywang@fudan.edu.cn.
  • Yu J; Department of Electronic Engineering, Fudan University, Shanghai 200433, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai 200433, China.
  • Guo W; Department of Electronic Engineering, Fudan University, Shanghai 200433, China.
  • Li T; Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region.
  • Zheng YP; Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region.
Ultrasonics ; 65: 23-33, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26582600
ABSTRACT
This paper introduces a new beamformer, which combines the eigenspace based minimum variance (ESBMV) beamformer with a subarray coherence based postfilter (SCBP), for improving the quality of ultrasound plane-wave imaging. The ESBMV beamformer has been validated in improving the imaging contrast, but the difficulty in dividing the signal subspace limits the usage of it in the low signal-to-noise ratio (SNR) scenarios. Coherence factor (CF) based methods could optimize the output of a distortionless beamformer to reduce sidelobes, but the influence by the subarray decorrelation technique on the postfilter design has not attracted enough concern before. Accordingly, an ESBMV-SCBP beamformer was proposed in this paper, which used the coherence of the subarray signal to compute an SCBP to optimize the ESBMV results. Simulated and experimental data were used to evaluate the performance of the proposed method. The results showed that the ESBMV-SCBP method achieved an improved imaging quality compared with the ESBMV beamformer. In the simulation study, the contrast ratio (CR) for an anechoic cyst was improved by 9.88 dB and the contrast-to-noise ratio (CNR) was improved by 0.97 over the ESBMV. In the experimental study, the CR improvements for two anechoic cysts were 7.32 dB and 9.45 dB, while the CNRs were improved by 1.27 and 0.66, respectively. The ESBMV-SCBP also showed advantages over the ESBMV-Wiener beamformer in preserving a less grainy speckle, which is closer to that of distortionless beamformers and benefits the imaging contrast. With a relatively small extra computational load, the proposed method has potential to enhance the quality of the ultrasound plane-wave imaging.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Algoritmos / Procesamiento de Señales Asistido por Computador / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Ultrasonografía Tipo de estudio: Diagnostic_studies Idioma: En Revista: Ultrasonics Año: 2016 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Algoritmos / Procesamiento de Señales Asistido por Computador / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Ultrasonografía Tipo de estudio: Diagnostic_studies Idioma: En Revista: Ultrasonics Año: 2016 Tipo del documento: Article