Development of a wireless blood pressure measuring device with smart mobile device.
Ilhan, Ilhan; Yildiz, Ibrahim; Kayrak, Mehmet.
Afiliación
  • Ilhan I; Department of Mechatronic Engineering, Fac. Eng. Arch., Necmettin Erbakan University, 42090 Konya, Turkey. Electronic address: ilhan@konya.edu.tr.
  • Yildiz I; Department of Mechatronic Engineering, Fac. Eng. Arch., Necmettin Erbakan University, 42090 Konya, Turkey. Electronic address: iyildiz@konya.edu.tr.
  • Kayrak M; Department of Cardiology, Meram Medical Faculty, Necmettin Erbakan University, 42090 Konya, Turkey. Electronic address: mehmetkayrak@yahoo.com.
Comput Methods Programs Biomed ; 125: 94-102, 2016 Mar.
Article en En | MEDLINE | ID: mdl-26626086
ABSTRACT
Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Ondas de Radio / Determinación de la Presión Sanguínea / Teléfono Inteligente Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2016 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Ondas de Radio / Determinación de la Presión Sanguínea / Teléfono Inteligente Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2016 Tipo del documento: Article