Your browser doesn't support javascript.
loading
Bacteria counting method based on polyaniline/bacteria thin film.
Zhihua, Li; Xuetao, Hu; Jiyong, Shi; Xiaobo, Zou; Xiaowei, Huang; Xucheng, Zhou; Tahir, Haroon Elrasheid; Holmes, Mel; Povey, Malcolm.
Afiliación
  • Zhihua L; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Xuetao H; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Jiyong S; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Xiaobo Z; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China. Electronic address: zou_xiaobo@ujs.edu.cn.
  • Xiaowei H; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Xucheng Z; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Tahir HE; College of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Holmes M; School of Food Science and Nutrition, the University of Leeds, Leeds LS2 9JT, United Kingdom.
  • Povey M; School of Food Science and Nutrition, the University of Leeds, Leeds LS2 9JT, United Kingdom.
Biosens Bioelectron ; 81: 75-79, 2016 Jul 15.
Article en En | MEDLINE | ID: mdl-26921555
ABSTRACT
A simple and rapid bacteria counting method based on polyaniline (PANI)/bacteria thin film was proposed. Since the negative effects of immobilized bacteria on the deposition of PANI on glass carbon electrode (GCE), PANI/bacteria thin films containing decreased amount of PANI would be obtained when increasing the bacteria concentration. The prepared PANI/bacteria film was characterized with cyclic voltammetry (CV) technique to provide quantitative index for the determination of the bacteria count, and electrochemical impedance spectroscopy (EIS) was also performed to further investigate the difference in the PANI/bacteria films. Good linear relationship of the peak currents of the CVs and the log total count of bacteria (Bacillus subtilis) could be established using the equation Y=-30.413X+272.560 (R(2)=0.982) over the range of 5.3×10(4) to 5.3×10(8)CFUmL(-1), which also showed acceptable stability, reproducibility and switchable ability. The proposed method was feasible for simple and rapid counting of bacteria.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Bacterias / Técnicas Biosensibles / Carga Bacteriana / Compuestos de Anilina Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2016 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Bacterias / Técnicas Biosensibles / Carga Bacteriana / Compuestos de Anilina Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2016 Tipo del documento: Article