Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis.
Landes, Uri; Sagie, Alexander; Kornowski, Ran.
Afiliación
  • Landes U; Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel.
  • Sagie A; Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel.
  • Kornowski R; Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel.
Catheter Cardiovasc Interv ; 91(5): 1000-1004, 2018 04 01.
Article en En | MEDLINE | ID: mdl-27696650
ABSTRACT
Sutureless aortic bioprostheses (SAB) are increasingly being used to provide shorter cross-clamp time. Valve-in-valve transcatheter aortic valve replacement (VIV-A) is shown to be effective and safe in the vast majority of patients with degenerated bioprosthetics, yet its' use in SAB failure is infrequent. We present a case of balloon-expandable VIV-A in an 80-year-old woman who suffered severe symptomatic aortic regurgitation in a failed Perceval S 21-mm valve. Computed tomography scan demonstrated a deformed valve. Our heart team favored a percutaneous VIV-A over reoperation due to the patients' high surgical risk. An Edwards-Sapien XT 23 mm was successfully deployed with excellent results. The patient remained asymptomatic following 6 months. As other bioprosthesis, some sutureless valves are condemned to structural valve degeneration. Because VIV-A is being established for managing degenerative bioprosthesis in high risk patients, it is cardinal to identify its role in novel degenerative sutureless valves. SAB were introduced to the clinical market only 5-7 years ago. The absence of sutures may theoretically impose risk for valve instability when adding a transcatheter sutureless valve inside the first one. Our successful experience was very reassuring. We report its feasibility because we believe it should provide support for further investigation on VIV-A within novel SAV. © 2016 Wiley Periodicals, Inc.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Insuficiencia de la Válvula Aórtica / Bioprótesis / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Etiology_studies / Prognostic_studies Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Insuficiencia de la Válvula Aórtica / Bioprótesis / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Etiology_studies / Prognostic_studies Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article