A Silicon Photo-multiplier Signal Readout Using Strip-line and Waveform Sampling for Positron Emission Tomography.
Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Kao, C-M.
Afiliación
  • Kim H; Department of Radiology, University of Chicago, Chicago, IL 60637.
  • Chen CT; Department of Radiology, University of Chicago, Chicago, IL 60637.
  • Eclov N; Department of Radiology, University of Chicago, Chicago, IL 60637.
  • Ronzhin A; Fermi National Accelerator Laboratory, IL, US.
  • Murat P; Fermi National Accelerator Laboratory, IL, US.
  • Ramberg E; Fermi National Accelerator Laboratory, IL, US.
  • Los S; Fermi National Accelerator Laboratory, IL, US.
  • Kao CM; Department of Radiology, University of Chicago, Chicago, IL 60637.
Nucl Instrum Methods Phys Res A ; 830: 119-129, 2016 Sep 11.
Article en En | MEDLINE | ID: mdl-27746514
ABSTRACT
A strip-line and waveform sampling based readout is a signal multiplexing method that can efficiently reduce the readout channels while fully exploiting the fast time characteristics of photo-detectors such as the SiPM. We have applied this readout method for SiPM-based time-of-flight (TOF) positron emission tomography (PET) detectors. We have prototyped strip-line boards in which 8 SiPMs (pitch 5.2 mm) are connected by using a single strip-line, and the signals appearing at the ends of the strip-line are acquired by using the DRS4 waveform sampler at a nominal sampling frequency of 1-5 GS/s. Experimental tests using laser and LYSO scintillator are carried out to assess the performance of the strip-line board. Each SiPM position, which is inferred from the arrival time difference of the two signals at the ends of the strip-line, is well identified with 2.6 mm FWHM resolution when the SiPMs are coupled to LYSO crystals and irradiated by a 22Na source. The average energy and coincidence time resolution responding to 511 keV photons are measured to be ~32% and ~510 ps FWHM, respectively, at a 5.0 GS/s DRS4 sampling rate. The results show that the sampling rate can be lowered to 1.5 GS/s without performance degradation. These encouraging initial test results indicate that the strip-line and waveform sampling readout method is applicable for SiPM-based TOF PET development.