Your browser doesn't support javascript.
loading
Impact of negative inotropic drugs on accuracy of diastolic stress echocardiography for evaluation of left ventricular filling pressure.
Salem, Joe-Elie; Laveau, Florent; Ceccaldi, Alexandre; Funck-Brentano, Christian; Hulot, Jean Sebastien; Mameri, Amel; Barthelemy, Olivier; Helft, Gerard; Feuvre, Claude Le; Isnard, Richard; Hammoudi, Nadjib.
Afiliación
  • Salem JE; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France. joe-elie.salem@aphp.fr.
  • Laveau F; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Ceccaldi A; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Funck-Brentano C; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Hulot JS; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Mameri A; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Barthelemy O; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Helft G; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Feuvre CL; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Isnard R; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
  • Hammoudi N; Sorbonne Universités, UPMC Univ Paris 06, AP-HP, CIC 1421, CIC-Paris Est, Cardiology department-Echocardiography Unit, Pharmacology department, INSERM-U1166 ICAN, Pitié-Salpêtrière Hospital, F-75013, Paris, France.
Sci Rep ; 7(1): 9537, 2017 08 25.
Article en En | MEDLINE | ID: mdl-28842666
ABSTRACT
The ratio of early diastolic trans-mitral flow velocity to tissue-Doppler mitral annular early diastolic velocity (E/e'), and left ventricular end-diastolic pressure(LVEDP) have been shown to be correlated at rest, provided that patients are not on positive inotropic drugs. Data concerning the latter correlation during exercise stress are conflicting. Therefore, we investigated if use of negative inotropic drugs (NID), impacts the accuracy of E/e' as a surrogate for LVEDP during low-level exercise. An exercise(50 watts) during cardiac invasive hemodynamic monitoring and an exercise echocardiography were performed prospectively within 24 hours in 54 patients (81%male, 62 ± 9years) with preserved LV Ejection-Fraction. Before exercise, the patients had scattered LVEDP (13.8 ± 5.8 mmHg) and septal E/e' (8.7 ± 2.7). Half of them were on NID, mainly betablockers(n = 26). The correlation between septal-E/e' and LVEDP was low for examinations performed at rest (r = 0.35,p = 0.01) with no significant impact of NID. For measurements performed at 50 Watts, NID had a significant impact on the association between septal-E/e'50 watts and LVEDP50 watts (ß = -0.28,p = 0.03). Correlation between septal-E/e'50 watts and LVEDP50 watts persisted in patients on NID (r = 0.61,p = 0.001) while it disappeared in the group of patients with no NID (r = 0.15,p = 0.47). NID use is an important confounding factor to take into consideration when assessing exercise LVFP using stress E/e' in patients with preserved LVEF.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Función Ventricular Izquierda / Presión Ventricular / Ecocardiografía de Estrés / Diástole Idioma: En Revista: Sci Rep Año: 2017 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Función Ventricular Izquierda / Presión Ventricular / Ecocardiografía de Estrés / Diástole Idioma: En Revista: Sci Rep Año: 2017 Tipo del documento: Article