Your browser doesn't support javascript.
loading
Design and use of a folded four-ring double-tuned birdcage coil for rat brain sodium imaging at 9.4 T.
Ha, YongHyun; Choi, Chang-Hoon; Worthoff, Wieland A; Shymanskaya, Aliaksandra; Schöneck, Michael; Willuweit, Antje; Felder, Jörg; Shah, N Jon.
Afiliación
  • Ha Y; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
  • Choi CH; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany. Electronic address: c.choi@fz-juelich.de.
  • Worthoff WA; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
  • Shymanskaya A; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
  • Schöneck M; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
  • Willuweit A; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
  • Felder J; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
  • Shah NJ; Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany; Faculty of Medicine, Department of Neurology, RWTH Aachen University, JARA, Aachen, Germany.
J Magn Reson ; 286: 110-114, 2018 01.
Article en En | MEDLINE | ID: mdl-29227914
ABSTRACT
A folded four-ring quadrature birdcage coil was designed and constructed with a double-tune configuration of an outer high-pass coil for 1H (400 MHz) and inner low-pass coil for 23Na (105.72 MHz at 9.4 T). The coil was evaluated on the bench and in the scanner, comparing its performance with that of single-tuned coils and a large four-ring coil. All coils were tuned and matched and the isolation between two quadrature ports was found to be better than -13.7 dB for 1H and -27 dB for 23Na. Signal-to-noise ratios (SNRs) were calculated and 23Na flip angle maps were acquired. 23Na SNR of the folded four-ring reached ∼93% of that obtained with the single-tuned coil. A set of in vivo1H and 23Na axial images to cover the whole rat brain were obtained. The performance of the folded four-ring coil and its benefit for 23Na imaging experiments have been demonstrated. This proposed four-ring coil could avoid length restrictions, e.g. the shoulders, by folding the outer rings vertically. This facilitates the construction of double-tuned four-ring birdcage coils just to fit the head, leading to higher filling factors and better SNR.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Sodio / Encéfalo / Imagen por Resonancia Magnética Idioma: En Revista: J Magn Reson Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Sodio / Encéfalo / Imagen por Resonancia Magnética Idioma: En Revista: J Magn Reson Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article