Your browser doesn't support javascript.
loading
3-Year Outcomes of the Edwards SAPIEN Transcatheter Heart Valve for Conduit Failure in the Pulmonary Position From the COMPASSION Multicenter Clinical Trial.
Kenny, Damien; Rhodes, John F; Fleming, Gregory A; Kar, Saibal; Zahn, Evan M; Vincent, Julie; Shirali, Girish S; Gorelick, Jeremy; Fogel, Mark A; Fahey, John T; Kim, Dennis W; Babaliaros, Vasilis C; Armstrong, Aimee K; Hijazi, Ziyad M.
Afiliación
  • Kenny D; Our Lady's Children's Hospital, Dublin, Ireland. Electronic address: damien_kenny@icloud.com.
  • Rhodes JF; Miami Children's Health System, Miami, Florida; Duke University School of Medicine, Durham, North Carolina.
  • Fleming GA; Duke University School of Medicine, Durham, North Carolina.
  • Kar S; Cedars-Sinai Medical Center, Los Angeles, California.
  • Zahn EM; Cedars-Sinai Medical Center, Los Angeles, California.
  • Vincent J; Morgan Stanley Children's Hospital, New York, New York.
  • Shirali GS; Children's Mercy, Kansas City, Missouri.
  • Gorelick J; Edwards Lifesciences, Irvine, California.
  • Fogel MA; Children's Hospital of Philadelphia, Philadelphia, Pennsylvania.
  • Fahey JT; Yale New Haven Hospital, New Haven, Connecticut.
  • Kim DW; Children's Healthcare of Atlanta, Atlanta, Georgia.
  • Babaliaros VC; Emory University School of Medicine, Atlanta, Georgia.
  • Armstrong AK; Nationwide Children's Hospital, Columbus, Ohio.
  • Hijazi ZM; Sidra Cardiovascular Center of Excellence, Weill Cornell Medical College, Doha, Qatar.
JACC Cardiovasc Interv ; 11(19): 1920-1929, 2018 10 08.
Article en En | MEDLINE | ID: mdl-30286853
ABSTRACT

OBJECTIVES:

This study provides the 3-year follow-up results of the COMPASSION (Congenital Multicenter Trial of Pulmonic Valve Regurgitation Studying the SAPIEN Transcatheter Heart Valve) trial. Patients with moderate to severe pulmonary regurgitation and/or right ventricular outflow tract conduit obstruction were implanted with the SAPIEN transcatheter heart valve (THV).

BACKGROUND:

Early safety and efficacy of the Edwards SAPIEN THV in the pulmonary position have been established through a multicenter clinical trial.

METHODS:

Eligible patients were included if body weight was >35 kg and in situ conduit diameter was ≥16 and ≤24 mm. Adverse events were adjudicated by an independent clinical events committee. Three-year clinical and echocardiographic outcomes were evaluated in these patients.

RESULTS:

Fifty-seven of the 63 eligible patients were accounted for at the 3-year follow-up visit from a total of 69 implantations in 81 enrolled patients. THV implantation was indicated for pulmonary stenosis (7.6%), regurgitation (12.7%), or both (79.7%). Twenty-two patients (27.8%) underwent implantation of 26-mm valves, and 47 patients received 23-mm valves. Functional improvement in New York Heart Association functional class was observed in 93.5% of patients. Mean peak conduit gradient decreased from 37.5 ± 25.4 to 17.8 ± 12.4 mm Hg (p < 0.001), and mean right ventricular systolic pressure decreased from 59.6 ± 17.7 to 42.9 ± 13.4 mm Hg (p < 0.001). Pulmonary regurgitation was mild or less in 91.1% of patients. Freedom from all-cause mortality at 3 years was 98.4%. Freedom from reintervention was 93.7% and from endocarditis was 97.1% at 3 years. There were no observed stent fractures.

CONCLUSIONS:

Transcatheter pulmonary valve replacement using the Edwards SAPIEN THV demonstrates excellent valve function and clinical outcomes at 3-year follow-up.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Válvula Pulmonar / Insuficiencia de la Válvula Pulmonar / Prótesis Valvulares Cardíacas / Obstrucción del Flujo Ventricular Externo / Cateterismo Cardíaco / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies País/Región como asunto: America do norte Idioma: En Revista: JACC Cardiovasc Interv Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2018 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Válvula Pulmonar / Insuficiencia de la Válvula Pulmonar / Prótesis Valvulares Cardíacas / Obstrucción del Flujo Ventricular Externo / Cateterismo Cardíaco / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies País/Región como asunto: America do norte Idioma: En Revista: JACC Cardiovasc Interv Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2018 Tipo del documento: Article