Your browser doesn't support javascript.
loading
In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function.
Yerly, Jérôme; Becce, Fabio; van Heeswijk, Ruud B; Verdun, Francis R; Gubian, Danilo; Meuli, Reto; Stuber, Matthias.
Afiliación
  • Yerly J; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011, VD, Switzerland. yerlyj.mri@gmail.com.
  • Becce F; Center for Biomedical Imaging (CIBM), Lausanne, Switzerland. yerlyj.mri@gmail.com.
  • van Heeswijk RB; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011, VD, Switzerland.
  • Verdun FR; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011, VD, Switzerland.
  • Gubian D; Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.
  • Meuli R; Institute of Radiation Physics, Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland.
  • Stuber M; Direction des Constructions, Ingénierie, Technique et Sécurité (CIT-S), Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland.
J Cardiovasc Magn Reson ; 21(1): 11, 2019 02 07.
Article en En | MEDLINE | ID: mdl-30728035
BACKGROUND: Our objectives were first to determine the optimal coronary computed tomography angiography (CTA) protocol for the quantification and detection of simulated coronary artery cross-sectional area (CSA) differences in vitro, and secondly to quantitatively compare the performance of the optimized CTA protocol with a previously validated radial coronary cardiovascular magnetic resonance (CMR) technique. METHODS: 256-multidetector CTA and radial coronary CMR were used to obtain images of a custom in vitro resolution phantom simulating a range of physiological responses of coronary arteries to stress. CSAs were automatically quantified and compared with known nominal values to determine the accuracy, precision, signal-to-noise ratio (SNR), and circularity of CSA measurements, as well as the limit of detection (LOD) of CSA differences. Various iodine concentrations, radiation dose levels, tube potentials, and iterative image reconstruction algorithms (ASiR-V) were investigated to determine the optimal CTA protocol. The performance of the optimized CTA protocol was then compared with a radial coronary CMR method previously developed for endothelial function assessment under both static and moving conditions. RESULTS: The iodine concentration, dose level, tube potential, and reconstruction algorithm all had significant effects (all p <  0.001) on the accuracy, precision, LOD, SNR, and circularity of CSA measurements with CTA. The best precision, LOD, SNR, and circularity with CTA were achieved with 6% iodine, 20 mGy, 100 kVp, and 90% ASiR-V. Compared with the optimized CTA protocol under static conditions, radial coronary CMR was less accurate (- 0.91 ± 0.13 mm2 vs. -0.35 ± 0.04 mm2, p <  0.001), but more precise (0.08 ± 0.02 mm2 vs. 0.21 ± 0.02 mm2, p <  0.001), and enabled the detection of significantly smaller CSA differences (0.16 ± 0.06 mm2 vs. 0.52 ± 0.04 mm2; p <  0.001; corresponding to CSA percentage differences of 2.3 ± 0.8% vs. 7.4 ± 0.6% for a 3-mm baseline diameter). The same results held true under moving conditions as CSA measurements with CMR were less affected by motion. CONCLUSIONS: Radial coronary CMR was more precise and outperformed CTA for the specific task of detecting small CSA differences in vitro, and was able to reliably identify CSA changes an order of magnitude smaller than those reported for healthy physiological vasomotor responses of proximal coronary arteries. However, CTA yielded more accurate CSA measurements, which may prove useful in other clinical scenarios, such as coronary artery stenosis assessment.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Endotelio Vascular / Imagen por Resonancia Magnética / Angiografía Coronaria / Vasos Coronarios / Tomografía Computarizada Multidetector / Angiografía por Tomografía Computarizada Tipo de estudio: Guideline / Prevalence_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Cardiovasc Magn Reson Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Endotelio Vascular / Imagen por Resonancia Magnética / Angiografía Coronaria / Vasos Coronarios / Tomografía Computarizada Multidetector / Angiografía por Tomografía Computarizada Tipo de estudio: Guideline / Prevalence_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Cardiovasc Magn Reson Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article