Your browser doesn't support javascript.
loading
Qualification of a chemotherapy-compounding robot.
Jobard, Marion; Brandely-Piat, Marie-Laure; Chast, François; Batista, Rui.
Afiliación
  • Jobard M; Service de Pharmacie clinique, Hôpitaux Universitaires Paris Centre, Assistance Publique - Hôpitaux de Paris, Paris, France.
  • Brandely-Piat ML; Service de Pharmacie clinique, Hôpitaux Universitaires Paris Centre, Assistance Publique - Hôpitaux de Paris, Paris, France.
  • Chast F; Service de Pharmacie clinique, Hôpitaux Universitaires Paris Centre, Assistance Publique - Hôpitaux de Paris, Paris, France.
  • Batista R; Service de Pharmacie clinique, Hôpitaux Universitaires Paris Centre, Assistance Publique - Hôpitaux de Paris, Paris, France.
J Oncol Pharm Pract ; 26(2): 312-324, 2020 Mar.
Article en En | MEDLINE | ID: mdl-30997871
ABSTRACT
KIRO® Oncology (Kiro Grifols, Spain) is a robotic system for automated compounding of sterile injectable drugs including intravenous cytotoxic treatments. The present article describes the qualification procedure applied prior to production phases. Peristaltic pumps which ensure the reconstitution of drugs were tested with water and NaCl 0.9%. The performance of the robot (accuracy and precision) to prepare bags, syringes and elastomeric pumps was evaluated with three placebo solutions (aqueous, foaming and viscous) using gravimetric controls. Microbiological controls were also performed. The pumps met the requirements set for volumes ranging from 5 to 100 mL. A total of 274 preparations was compounded. For the bags, the filling accuracy was within the limit of ±10% from 1 to 48 mL with aqueous solution, from 0.6 to 48 mL with foaming solution and from 5 to 48 mL with viscous solution. For all syringes and elastomeric pumps, it was within the limit of ±10%. The precision was validated for all preparations, except for bags and syringes prepared with 0.6 and 0.25 mL, respectively. The samples of surfaces and air complied with ISO 5 class environment. Among the 24 gloves tests performed, two presented microbiological growth. All Media fill tests were validated. The qualification procedure led us to exclude injections of any active principle volume strictly lower than 1 mL. The microbiological contamination of operators' gloves remains a critical point. Our operators will be made aware of the issue during the training period.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Jeringas / Robótica / Contaminación de Medicamentos / Composición de Medicamentos / Antineoplásicos Tipo de estudio: Clinical_trials País/Región como asunto: Europa Idioma: En Revista: J Oncol Pharm Pract Asunto de la revista: FARMACIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Jeringas / Robótica / Contaminación de Medicamentos / Composición de Medicamentos / Antineoplásicos Tipo de estudio: Clinical_trials País/Región como asunto: Europa Idioma: En Revista: J Oncol Pharm Pract Asunto de la revista: FARMACIA Año: 2020 Tipo del documento: Article