Your browser doesn't support javascript.
loading
Sensitivity and specificity of single-fibre EMG in the diagnosis of ocular myasthenia varies accordingly to clinical presentation.
Giannoccaro, Maria Pia; Di Stasi, Vitantonio; Zanesini, Corrado; Donadio, Vincenzo; Avoni, Patrizia; Liguori, Rocco.
Afiliación
  • Giannoccaro MP; Dipartimento di Scienze Biomediche e Neuromotorie, Università di Bologna, Bologna, Italy. mpgiannoccaro@gmail.com.
  • Di Stasi V; IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna, Italy. mpgiannoccaro@gmail.com.
  • Zanesini C; IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna, Italy.
  • Donadio V; IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna, Italy.
  • Avoni P; IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna, Italy.
  • Liguori R; Dipartimento di Scienze Biomediche e Neuromotorie, Università di Bologna, Bologna, Italy.
J Neurol ; 267(3): 739-745, 2020 Mar.
Article en En | MEDLINE | ID: mdl-31734908
ABSTRACT
BACKGROUND AND

PURPOSE:

Single-fibre electromyography (SF-EMG) is considered as the most sensitive test for the diagnosis of MG. However, previous studies had limitations, such as a retrospective design, non-consecutive sampling, incorporation bias or were performed in small or mixed populations. Our aims were to determine the diagnostic sensitivity and specificity of SF-EMG of the orbicularis oculi in OMG and the utility of this test in relation to patients' clinical presentation. MATERIALS AND

METHODS:

We studied 232 consecutive patients referred to the SF-EMG laboratory for a suspected OMG. Stimulated SF-EMG was performed on the orbicularis oculi muscle.

RESULTS:

OMG was diagnosed in 165 cases and other disorders (OD) in 67. SF-EMG showed a sensitivity of 0.79 (95% CI 0.73-0.85) and a specificity of 0.80 (95% CI 0.71-0.90). False negative results were associated with mild symptoms and with isolated diplopia. Comparison of the diagnostic yield among patients with different clinical presentations showed a similar diagnostic accuracy of SF-EMG in patients with ptosis and in patients with ptosis and diplopia, significantly higher than in patients with isolated diplopia (P < 0.0001). Twenty-two patients with OMG presenting with isolated ptosis or diplopia, who initially tested negative, were re-tested in relation to a worsening of their symptoms showing a positivisation in 91% of cases.

CONCLUSIONS:

SF-EMG on the orbicularis oculi muscle is very sensitive in patients with ptosis. In contrast, in patients with isolated diplopia SF-EMG does not exclude OMG. Therefore, the interpretation of the results of the test should take into account the patients' clinical presentation.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Electromiografía / Miastenia Gravis Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Neurol Año: 2020 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Electromiografía / Miastenia Gravis Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Neurol Año: 2020 Tipo del documento: Article