Your browser doesn't support javascript.
loading
The influence of muzzle gas on the temporary cavity.
Schyma, C; Bauer, K; Müller, R; Brünig, J; Gotsmy, W.
Afiliación
  • Schyma C; Institute of Forensic Medicine, University of Bern, Bühlstrasse 20, CH-3012, Bern, Switzerland. christian.schyma@irm.unibe.ch.
  • Bauer K; Institute of Forensic Medicine, University of Bern, Bühlstrasse 20, CH-3012, Bern, Switzerland.
  • Müller R; Criminal Investigation Service of the Cantonal Police Department of Bern, Nordring 30, 3013, Bern, Switzerland.
  • Brünig J; Institute of Forensic Medicine, University of Bern, Bühlstrasse 20, CH-3012, Bern, Switzerland.
  • Gotsmy W; Institute of Forensic Medicine, University of Bern, Bühlstrasse 20, CH-3012, Bern, Switzerland.
Int J Legal Med ; 134(3): 1115-1122, 2020 May.
Article en En | MEDLINE | ID: mdl-32130474
ABSTRACT
Shot range, the muzzle-target distance, is a crucial parameter for forensic reconstruction of deaths by firearms. In a large number of cases, especially suicides, the forensic pathologist is confronted with contact or near-contact shots, where muzzle gases play an additional role. This study was conducted to systematically investigate the influence of muzzle gases on the temporary cavity (TC). A total of 72 shots were fired using full metal-jacketed bullets in four forensically relevant calibres from 10-, 5-, 3-, 2- and 1-cm distance and in close contact. Target model was the so-called reference cube (10% gelatine at 4 °C) with 12-cm edge length. The TC was recorded using high-speed video (HSV). Cross-sectional analysis was performed by cutting the blocks to 1-cm slices, which were evaluated by applying the polygon method. The TC of shots from 10 and 5 cm distance had a tubular form. This aspect changed depending on the cartridge with decreasing distance (≤ 3 cm) into a pear-like form, which was typical for contact shots. The cumulated heights of the TC increased with decreasing distance below 3 cm. Contact shots approximately doubled the extension of the TC compared with exclusive energy transfer. Whereas HSV documented an increasingly asymmetric profile with ballooning at the entry side, cross-sectional analysis of cracks in gelatine resulted in convex graphs with only slight asymmetry for contact shots. Additional damage in gelatine was detected for 3-cm distance or less in calibre .357 Magnum and ≤ 2 cm for .32 auto, .38 special and 9mm Luger. The increasing influence of muzzle gas pressure is detectable with decreasing shot range below 3 cm.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Presión / Heridas por Arma de Fuego / Armas de Fuego / Balística Forense / Gases Idioma: En Revista: Int J Legal Med Asunto de la revista: JURISPRUDENCIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Presión / Heridas por Arma de Fuego / Armas de Fuego / Balística Forense / Gases Idioma: En Revista: Int J Legal Med Asunto de la revista: JURISPRUDENCIA Año: 2020 Tipo del documento: Article