Your browser doesn't support javascript.
loading
Real-time non-contact cellular imaging and angiography of human cornea and limbus with common-path full-field/SD OCT.
Mazlin, Viacheslav; Xiao, Peng; Scholler, Jules; Irsch, Kristina; Grieve, Kate; Fink, Mathias; Boccara, A Claude.
Afiliación
  • Mazlin V; Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France. mazlin.slava@gmail.com.
  • Xiao P; Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France. xiaopengaddis@hotmail.com.
  • Scholler J; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, 510060, Guangzhou, China. xiaopengaddis@hotmail.com.
  • Irsch K; Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France.
  • Grieve K; Vision Institute/CIC 1423, Sorbonne University, UMR_S 968/INSERM, U968/CNRS, UMR_7210, 17 Rue Moreau, 75012, Paris, France.
  • Fink M; Quinze-Vingts National Eye Hospital, 28 Rue de Charenton, 75012, Paris, France.
  • Boccara AC; Vision Institute/CIC 1423, Sorbonne University, UMR_S 968/INSERM, U968/CNRS, UMR_7210, 17 Rue Moreau, 75012, Paris, France.
Nat Commun ; 11(1): 1868, 2020 04 20.
Article en En | MEDLINE | ID: mdl-32313067
ABSTRACT
In today's clinics, a cell-resolution view of the cornea can be achieved only with a confocal microscope (IVCM) in contact with the eye. Here, we present a common-path full-field/spectral-domain OCT microscope (FF/SD OCT), which enables cell-detail imaging of the entire ocular surface in humans (central and peripheral cornea, limbus, sclera, tear film) without contact and in real-time. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images contain cells and nerves, which can be quantified over a millimetric field-of-view, beyond the capability of IVCM and conventional OCT. In the limbus, palisades of Vogt, vessels, and blood flow can be resolved with high contrast without contrast agent injection. The fast imaging speed of 275 frames/s (0.6 billion pixels/s) allows direct monitoring of blood flow dynamics, enabling creation of high-resolution velocity maps. Tear flow velocity and evaporation time can be measured without fluorescein administration.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Angiografía / Córnea / Tomografía de Coherencia Óptica Idioma: En Revista: Nat Commun Asunto de la revista: BIOLOGIA / CIENCIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Angiografía / Córnea / Tomografía de Coherencia Óptica Idioma: En Revista: Nat Commun Asunto de la revista: BIOLOGIA / CIENCIA Año: 2020 Tipo del documento: Article