Prototype system for interventional dual-energy subtraction angiography.
Speidel, Michael A; Burton, Christiane S; Nikolau, Ethan P; Schafer, Sebastian; Laeseke, Paul F.
Afiliación
  • Speidel MA; Dept. of Medical Physics, Univ. of Wisconsin - Madison, Madison, WI, USA.
  • Burton CS; Dept. of Medicine, Univ. of Wisconsin - Madison, Madison, WI, USA.
  • Nikolau EP; Dept. of Radiology, Univ. of Wisconsin - Madison, Madison, WI, USA.
  • Schafer S; Dept. of Medical Physics, Univ. of Wisconsin - Madison, Madison, WI, USA.
  • Laeseke PF; Siemens Healthineers, Hoffman Estates, IL, USA.
Article en En | MEDLINE | ID: mdl-32669753
ABSTRACT
Dual-energy subtraction angiography (DESA) using fast kV switching has received attention for its potential to reduce misregistration artifacts in thoracic and abdominal imaging where patient motion is difficult to control; however, commercial interventional solutions are not currently available. The purpose of this work was to adapt an x-ray angiography system for 2D and 3D DESA. The platform for the dual-energy prototype was a commercially available x-ray angiography system with a flat panel detector and an 80 kW x-ray tube. Fast kV switching was implemented using custom x-ray tube control software that follows a user-defined switching program during a rotational acquisition. Measurements made with a high temporal resolution kV meter were used to calibrate the relationship between the requested and achieved kV and pulse width. To enable practical 2D and 3D imaging experiments, an automatic exposure control algorithm was developed to estimate patient thickness and select a dual-energy switching technique (kV and ms switching) that delivers a user-specified task CNR at the minimum air kerma to the interventional reference point. An XCAT-based simulation study conducted to evaluate low and high energy image registration for the scenario of 30-60 frame/s pulmonary angiography with respiratory motion found normalized RMSE values ranging from 0.16% to 1.06% in tissue-subtracted DESA images, depending on respiratory phase and frame rate. Initial imaging in a porcine model with a 60 kV, 10 ms, 325 mA / 120 kV, 3.2 ms, 325 mA switching technique demonstrated an ability to form tissue-subtracted images from a single contrast-enhanced acquisition.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Proc SPIE Int Soc Opt Eng Año: 2019 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Proc SPIE Int Soc Opt Eng Año: 2019 Tipo del documento: Article